




已閱讀5頁,還剩52頁未讀, 繼續(xù)免費(fèi)閱讀
版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡介
XH9005-B型COD在線監(jiān)測(cè)儀XH9005-B型COD在線自動(dòng)監(jiān)測(cè)儀培訓(xùn)教材河北先河科技發(fā)展有限公司目 錄1.概述42.功能與特點(diǎn)43主要技術(shù)指標(biāo)53.1 COD技術(shù)指標(biāo)53.2流量技術(shù)指標(biāo)64儀器的測(cè)試原理65儀器的結(jié)構(gòu)及工作過程65.1結(jié)構(gòu)組成65.2工作流程:76操作說明96.1 單擊測(cè)試畫面鍵進(jìn)入“測(cè)試畫面”106.3 單擊閥體監(jiān)視鍵進(jìn)入“閥體監(jiān)視”畫面。116.5 單擊報(bào)警查詢鍵進(jìn)入“報(bào)警查詢”畫面。136.6 單擊調(diào)試鍵系統(tǒng)進(jìn)入“調(diào)試”畫面。156.6.1點(diǎn)擊時(shí)間參數(shù)調(diào)試進(jìn)入時(shí)間參數(shù)設(shè)置狀態(tài)156.7.1 單擊時(shí)鐘鍵進(jìn)入“設(shè)置時(shí)鐘”畫面167.1儀器運(yùn)行基本條件207.2站房要求207.3配電要求217.4管路準(zhǔn)備217.5巴歇爾流量槽概要237.7需用戶提前準(zhǔn)備的物品298.現(xiàn)場(chǎng)操作298.1準(zhǔn)備工作298.2配制試劑298.3將液體試劑和蒸餾水分別注入試劑瓶和蒸餾水箱,注完后請(qǐng)及時(shí)將瓶塞和箱蓋蓋好,液位不低于2/3箱高。328.4往冷卻箱中注入蒸餾水或自來水(自來水不影響冷卻效果,但會(huì)在管壁結(jié)水垢),液位不低于1/3箱高。328.5連接采樣管路。328.6連接主機(jī)污水排放管路,將其出口置于下水道。注意:排放口應(yīng)低于主機(jī)底板且廢液排放管不要超過2米。328.7連接廢液箱及主機(jī)進(jìn)水管路。328.8連接信號(hào)線(適配器用)及電話線。328.9連接好主機(jī)電源。329系統(tǒng)調(diào)試329.1閥體的調(diào)試329.2 冷卻泵的調(diào)試33.3 其它部件調(diào)試339.4試劑計(jì)量管的調(diào)節(jié)339.5倒進(jìn)樣計(jì)量杯調(diào)試349.6發(fā)射、接收光路調(diào)試349.7溫控儀的調(diào)試359.8氣泵調(diào)試3899 2AD模塊的調(diào)試389.10 2DA模塊的調(diào)試399.11 高級(jí)調(diào)試4010運(yùn)行4610.1 儀器運(yùn)行條件4611.怎樣保證驗(yàn)收通過4711.1保證儀器的高度穩(wěn)定4711.2 加強(qiáng)質(zhì)控手段4711.3 實(shí)際水樣的測(cè)定4812. 日常維護(hù)4813故障報(bào)警及分析49131. 如何判斷電磁閥的好壞?50132“AD值=0”:51133 哪些原因會(huì)導(dǎo)致COD值異常偏高?5113.4 消解器溫度超高:5113.5儀器報(bào)警后怎樣處理?5213.6 光控計(jì)量失控如何處理?5213.7 何時(shí)檢查保險(xiǎn)管?53附錄1 儀器示意圖54附錄2 主控電路板原理圖55附錄3561.概述COD即化學(xué)需氧量(Chemical Oxygen Demand),是指在一定條件下,水體中易被強(qiáng)氧化劑重鉻酸鉀(K2Cr2O7)氧化的溶解態(tài)或懸浮態(tài)還原性物質(zhì)所消耗重鉻酸鉀相對(duì)應(yīng)的氧的質(zhì)量濃度,以氧的毫克/升來表示。化學(xué)需氧量被廣泛地應(yīng)用于污水中有機(jī)物含量的測(cè)定,是評(píng)價(jià)水體污染程度的重要參數(shù)。2.功能與特點(diǎn)2.1 采用可編程控制器做控制核心,抗干擾能力強(qiáng),運(yùn)行可靠,自動(dòng)控制系統(tǒng)平均無故障運(yùn)行時(shí)間15萬小時(shí),保障了長期在線監(jiān)測(cè)。2.2 采用光控計(jì)量結(jié)構(gòu),計(jì)量精度高,重復(fù)性好。2.3 采用大通徑防腐電磁閥,抗堵能力強(qiáng),耐腐蝕,壽命長,可靠性高。2.4 采用特殊合成試劑,能有效地縮短消解時(shí)間,抑制氯離子干擾。該合成試劑為固體瓶裝,便于攜帶,易于運(yùn)輸,并且配制簡單,價(jià)格低廉。測(cè)試周期短,僅為18分鐘,從而保證了環(huán)境監(jiān)測(cè)現(xiàn)場(chǎng)應(yīng)急測(cè)試的需要。2.5 采用全循環(huán)采樣方式,使采集的樣品具有實(shí)時(shí)代表性。2.6 采用彩色液晶觸摸屏,實(shí)現(xiàn)了監(jiān)視、控制一體化,儀器工作狀態(tài)一目了然,且減少了機(jī)械故障點(diǎn)。2.7 具有流量測(cè)定功能,能夠顯示瞬時(shí)流量、COD濃度、COD排放總量(需安裝超聲波傳感器)。2.8 能進(jìn)行標(biāo)樣和零點(diǎn)校正,具有自動(dòng)清洗功能。2.9 通過網(wǎng)絡(luò)實(shí)時(shí)的或成批的傳送測(cè)試數(shù)據(jù),可與“國家環(huán)境監(jiān)理系統(tǒng)”相連。2.10具有斷電保護(hù)與數(shù)據(jù)查詢、數(shù)據(jù)打印功能(需安裝打印機(jī))。2.11 具有故障報(bào)警與故障保護(hù)功能。3主要技術(shù)指標(biāo)3.1 COD技術(shù)指標(biāo)1)測(cè)量范圍:量程可變10-150mg/L 和100-1500mg/L2)重現(xiàn)性:10%3)量程漂移:8%4)零點(diǎn)漂移:5mg/L5)測(cè)量誤差:5%(鄰苯二甲酸氫鉀試驗(yàn))6)實(shí)際廢水樣品比對(duì)實(shí)驗(yàn):15%(相對(duì)誤差絕對(duì)值的平均值)7)平均無故障時(shí)間:360h/次8)電壓穩(wěn)定性:109)絕緣阻抗:20M以上10)消解器控溫范圍:(1652)11)測(cè)量周期:18分鐘24小時(shí)可調(diào)12)信號(hào)輸出:模擬 0-10VDC或0-5VDC,0-20mA或4-20mA;數(shù)字 RS232或RS48513)采樣泵:吸程5米,揚(yáng)程30米14)電源:220V AC 50Hz15)外型尺寸:6604001330(mm)16)重量:90kg17)整機(jī)平均功率:22OW3.2流量技術(shù)指標(biāo)1)符合明渠污水流量計(jì)、液位計(jì)暫行技術(shù)要求規(guī)定2)流量范圍:10-4103米/秒(流量量程與配用堰槽有關(guān))3)流量誤差:與配用量水堰槽有關(guān) 與三角堰配用:1%3% 與矩形堰配用:1%5% 與巴歇爾槽配用:3%4% 與無喉道槽配用:4%5%4)超聲測(cè)距范圍:0.4(盲區(qū))2米5)測(cè)距精度:0.4%6)水位分辨力:1毫米4儀器的測(cè)試原理本儀器采用國標(biāo)重鉻酸鉀法,通過恒溫器消解進(jìn)行快速催化氧化還原反應(yīng)。水體中的污染物被氧化,同時(shí)鉻離子由六價(jià)被還原為三價(jià)。自動(dòng)檢測(cè)系統(tǒng)通過分光比色測(cè)定鉻離子的濃度,計(jì)算出COD值,在顯示屏上顯示出來。5儀器的結(jié)構(gòu)及工作過程5.1結(jié)構(gòu)組成COD在線監(jiān)測(cè)儀由采樣系統(tǒng)(采樣泵、過濾器)、加液計(jì)量系統(tǒng)(計(jì)量管、計(jì)量池)、控制系統(tǒng)(PLC、溫控儀、閥體)、測(cè)試系統(tǒng)(分光、模數(shù)轉(zhuǎn)換)、數(shù)據(jù)存儲(chǔ)和顯示系統(tǒng)(觸摸屏)等部分組成。5.2工作流程:1)采樣泵根據(jù)預(yù)定的采樣模式,將水樣采入主機(jī),輸送給進(jìn)樣閥;進(jìn)樣閥、加液計(jì)量系統(tǒng)在控制系統(tǒng)的控制下按比例加入水樣和試劑,并完成混勻、恒溫消解、冷卻等操作;測(cè)試系統(tǒng)通過對(duì)已消解、冷卻后的混合液進(jìn)行測(cè)量、數(shù)據(jù)格式轉(zhuǎn)換,最終計(jì)算出COD值,送給數(shù)據(jù)存儲(chǔ)及顯示系統(tǒng)。2)儀器自動(dòng)運(yùn)行流程圖雙擊自動(dòng)鍵,儀器進(jìn)入自動(dòng)運(yùn)行狀態(tài)。為了對(duì)儀器進(jìn)行保護(hù),按自動(dòng)鍵20秒后儀器才開始自動(dòng)運(yùn)行。初始化工作雙擊自動(dòng)鍵進(jìn)入“預(yù)備自動(dòng)”狀態(tài)保護(hù)性延時(shí)20秒沖洗各閥,打開溫控儀延時(shí)22分鐘,等待溫度升至165進(jìn)水樣、加試劑混勻消解10分鐘冷卻5分鐘比色、顯示結(jié)果測(cè)試周期是否到 N Y 注:COD的采水流程如下:6操作說明打開電源開關(guān),觸摸屏首先顯示標(biāo)題畫面,5秒后進(jìn)入主菜單:“功能菜單”。在功能菜單中,可切換到任意一畫面,各藍(lán)底黑字鍵均為觸摸鍵,輕輕一按便可進(jìn)入相應(yīng)畫面。6.1 單擊測(cè)試畫面鍵進(jìn)入“測(cè)試畫面”在測(cè)試畫面中,可觀察到系統(tǒng)時(shí)間、系統(tǒng)運(yùn)行狀態(tài)、COD值的模擬顯示與數(shù)字顯示,上小時(shí)累計(jì)流量、本周期累計(jì)流量、總累計(jì)流量、總累計(jì)排放量。手動(dòng)/自動(dòng)鍵設(shè)為雙擊鍵,即在設(shè)定時(shí)間內(nèi)連續(xù)點(diǎn)擊兩次方可有效。其中手動(dòng)轉(zhuǎn)換到自動(dòng)狀態(tài)有20秒的延時(shí),在20秒內(nèi),再雙擊手動(dòng)鍵可返回手動(dòng)狀態(tài),否則20秒后進(jìn)入自動(dòng)運(yùn)行狀態(tài)。此延時(shí)用于開機(jī)保護(hù)、上電保護(hù)。上小時(shí)流量指上小時(shí)0分0秒到上小時(shí)59分59秒的流量累積值,用于表征小時(shí)流量,周期累計(jì)流量為本測(cè)試周期內(nèi)的流量累積值,在下一周期開始時(shí)自動(dòng)復(fù)零。6.2 單擊按鍵監(jiān)控鍵進(jìn)入“按鍵監(jiān)控”畫面此畫面主要用于手動(dòng)調(diào)試。每個(gè)黃底黑字鍵都對(duì)應(yīng)著儀器的一個(gè)部件,在手動(dòng)狀態(tài)下,按動(dòng)哪個(gè)鍵,對(duì)應(yīng)的閥體或部件動(dòng)作,同時(shí)此鍵背景由黃變紅。在自動(dòng)運(yùn)行狀態(tài),此畫面只能觀察到哪個(gè)部件在動(dòng)作,不能對(duì)其進(jìn)行控制。其中溫度到163度鍵用于在自動(dòng)運(yùn)行時(shí),消解器溫度已達(dá)到163,而延遲等待時(shí)間還未到22分鐘的情況下加快測(cè)試流程。1ml試劑指有顏色的氧化劑。6.3 單擊閥體監(jiān)視鍵進(jìn)入“閥體監(jiān)視”畫面。在閥體監(jiān)視畫面中,可觀察到整個(gè)流程,各個(gè)閥體及部件運(yùn)行狀態(tài)、液面動(dòng)向、流程位置、流程時(shí)間等。例如消解閥,當(dāng)水樣與試劑混勻后進(jìn)入消解閥,右側(cè)“消解”鍵由藍(lán)變紅,同時(shí),時(shí)間從0秒開始計(jì)時(shí);左側(cè)的時(shí)間圓盤紅色逐漸增多。到10分鐘后,“消解”鍵變藍(lán),時(shí)間增到600.0秒,時(shí)間圓盤全部變紅,消解結(jié)束。6.4 單擊測(cè)試查詢鍵進(jìn)入“測(cè)試查詢”畫面。單擊返回,畫面回到功能主菜單。6.4.1單擊顯示結(jié)果(清單)可查閱測(cè)試數(shù)據(jù)及相應(yīng)時(shí)間。最新數(shù)據(jù)顯示在最前排,可保存1000個(gè)數(shù)據(jù),超過1000組最舊數(shù)據(jù)將被會(huì)覆蓋,請(qǐng)及時(shí)記錄所需數(shù)據(jù)。在“結(jié)果清單”畫面中,單擊次數(shù)鍵,可快速修改查詢次數(shù)。6.4.2單擊清除數(shù)據(jù)按照下一級(jí)提示可清除歷史數(shù)據(jù)。數(shù)據(jù)清除不能單獨(dú)清除某一組數(shù)據(jù)。6.5 單擊報(bào)警查詢鍵進(jìn)入“報(bào)警查詢”畫面。6.5.1按報(bào)警狀態(tài)鍵,可查閱當(dāng)前報(bào)警的狀態(tài)與詳細(xì)說明。當(dāng)出現(xiàn)警報(bào)時(shí),儀器自動(dòng)保護(hù),蜂鳴器鳴叫?!皥?bào)警狀態(tài)”畫面相應(yīng)代碼條與詳細(xì)鍵變?yōu)榧t色。工作人員須排除相應(yīng)故障后,按報(bào)警復(fù)位鍵,儀器才能轉(zhuǎn)入正常工作。6.5.2按報(bào)警記錄顯示報(bào)警的時(shí)間與代碼。儀器總共能保存30次報(bào)警記錄。6.5.3“報(bào)警總計(jì)”顯示各類報(bào)警總共出現(xiàn)的次數(shù)。6.5.4“清除記錄”可清除儲(chǔ)存的報(bào)警記錄與報(bào)警總計(jì)。6.6 單擊調(diào)試鍵系統(tǒng)進(jìn)入“調(diào)試”畫面。6.6.1點(diǎn)擊時(shí)間參數(shù)調(diào)試進(jìn)入時(shí)間參數(shù)設(shè)置狀態(tài)在此畫面中,可對(duì)進(jìn)樣時(shí)間、蒸餾水時(shí)間、吹氣時(shí)長等時(shí)間參數(shù)進(jìn)行設(shè)定。出廠前已調(diào)試設(shè)置好參數(shù),只有當(dāng)進(jìn)行重新調(diào)試或測(cè)試結(jié)果誤差較大、進(jìn)樣異常等情況下,才能修改這些參數(shù)。它們的修改,將影響測(cè)量結(jié)果、應(yīng)非常慎重。修改某參數(shù)時(shí),按動(dòng)該鍵,光標(biāo)停于該項(xiàng)后的數(shù)值上,再利用屏幕下方數(shù)字鍵鍵入修改值,按ENT鍵確認(rèn)修改或CLR鍵取消修改。注:1、“消解時(shí)間”、“冷卻時(shí)間“均可根據(jù)需要修改;2、“比色開始”是指從“冷卻閥”第一次排空開始計(jì)時(shí),所設(shè)置的時(shí)間到后開始采集數(shù)據(jù);3、“比色結(jié)束”也是從“冷卻閥”第一次排空后開始計(jì)時(shí),所設(shè)置的時(shí)間到后開啟“比色閥”,比色結(jié)束;4、“鼓泡時(shí)長”是指總共的鼓泡時(shí)間;5、“鼓泡間隔”指兩次鼓泡動(dòng)作的時(shí)間間隔(最多可以連續(xù)鼓泡6次);6、“AD偏差”指以上次的比色電壓值為基準(zhǔn)值(第一次比較時(shí)以0為基準(zhǔn)值),用這個(gè)基準(zhǔn)值結(jié)合設(shè)定的“AD偏差”值得到所需的出值區(qū)間,如果當(dāng)前的AD值在所得的區(qū)間內(nèi),按正常的流程運(yùn)行;否則,延長一定時(shí)間(可設(shè))后,再次采集比色AD值,進(jìn)行比較,直至當(dāng)前的AD值在上次得到的區(qū)間內(nèi)為止。6.6.2點(diǎn)擊流量計(jì)調(diào)試進(jìn)入時(shí)間流量計(jì)調(diào)試畫面?!叭斯y(cè)量液位”用于液位校準(zhǔn),將實(shí)測(cè)液位輸入后按“確認(rèn)”鍵,10秒后“儀器測(cè)量液位”將做相應(yīng)變化。6.7按參數(shù)設(shè)定鍵進(jìn)入“參數(shù)設(shè)定”畫面。6.7.1 單擊時(shí)鐘鍵進(jìn)入“設(shè)置時(shí)鐘”畫面修改方法為:先按設(shè)置鍵,背景色由藍(lán)變紅,系統(tǒng)時(shí)鐘中止運(yùn)行,需修改哪一數(shù)值,請(qǐng)按該數(shù),光標(biāo)停于該數(shù)值上,利用屏幕下方數(shù)字鍵鍵入所需修改值,再按ENT鍵確認(rèn)修改或按CLR鍵取消修改,最后按設(shè)置鍵恢復(fù)時(shí)鐘運(yùn)行。6.7.2按背光設(shè)置設(shè)置背光燈狀態(tài)點(diǎn)擊所要選擇項(xiàng),菜單鍵由藍(lán)變紅,點(diǎn)擊返回鍵,返回上一級(jí)菜單。選擇“背光燈10分鐘后關(guān)閉”,觸摸屏靜置10分鐘后背光燈將自動(dòng)關(guān)閉,以此來延長背光燈的使用壽命(建議使用此方式);輕觸觸摸屏任一位置都可自動(dòng)點(diǎn)亮背光燈。6.7.3按采樣周期設(shè)置采樣的周期 采樣周期是指本次進(jìn)樣距下次進(jìn)樣的時(shí)間間隔。按“測(cè)試周期”藍(lán)色觸摸鍵,光標(biāo)停于周期數(shù)值上,利用屏幕左方數(shù)字鍵鍵入所需修改數(shù)值,按ENT鍵確認(rèn)修改或CLR鍵取消修改。周期最低設(shè)定值為18分鐘,最大為1440分鐘. 特別注意:在自動(dòng)運(yùn)行過程中修改“測(cè)試周期”,如果由長周期改為短周期,請(qǐng)?jiān)谥芷谥甘拘∮凇?”時(shí)修改,或轉(zhuǎn)換到手動(dòng)狀態(tài)再進(jìn)入自動(dòng)運(yùn)行,或關(guān)機(jī)再重新開機(jī)。否則儀器不能正常工作。 測(cè)試前采樣 指在下一個(gè)周期開始前幾分鐘開啟采樣泵,使管路中的水提前循環(huán)起來,以保證所采集的瞬時(shí)樣具有實(shí)時(shí)代表性。此值不應(yīng)小于3分鐘。6.7.4按雙擊時(shí)間設(shè)定雙擊時(shí)間按“雙擊時(shí)間:”右面藍(lán)色觸摸鍵,光標(biāo)停于該項(xiàng)后的數(shù)值上,利用屏幕下方數(shù)字鍵鍵入所需修改數(shù)值,按ENT鍵確認(rèn)修改或CLR鍵取消修改。如:雙擊時(shí)間設(shè)為1秒,表示在1秒內(nèi)連續(xù)點(diǎn)擊兩次手動(dòng)或自動(dòng)鍵,點(diǎn)擊方可生效。設(shè)定時(shí)間長短根據(jù)個(gè)人愛好而定。6.7.5 按打印方式鍵可設(shè)定自動(dòng)/手動(dòng)打印方式。不安裝打印機(jī)時(shí)將給出提示信息。6.8 按幫助查看幫助內(nèi)容其中,操作說明介紹了儀器的操作過程及各個(gè)界面的使用方法,公司簡介中介紹了本公司的發(fā)展歷史及開發(fā)的系列產(chǎn)品,報(bào)警說明中給出了報(bào)警狀態(tài)代碼含義和引起報(bào)警的故障原因。7.安裝7.1儀器運(yùn)行基本條件1) 環(huán)境溫度:535。2) 相對(duì)濕度:85%。3) 電源電壓:AC220V(10%)4) 電源頻率:(501)Hz。7.2站房要求1) 站房整體結(jié)構(gòu)可分為:磚體結(jié)構(gòu)和彩鋼板兩種結(jié)構(gòu),可由客戶自行選擇。2) 據(jù)站房屋頂?shù)男螤顑x器站房可分為:尖頂房和平頂房兩種。在冬季多積雪、夏季雨量大的地區(qū)推薦采用尖頂房;其他地區(qū)可選擇平頂房。3) 站房內(nèi)部使用面積不少于12平方米,室內(nèi)屋頂高度不低于2.3米。4) 應(yīng)有水泥地基,地基高度尺寸(一般在300mm以上)必須保證在雨季不能有雨水灌入室內(nèi)。5) 室內(nèi)地面建議用全瓷地板磚鋪設(shè)。6) 站房窗戶外側(cè)必須安裝防盜網(wǎng),窗戶內(nèi)側(cè)安裝窗紗扇。7) 房頂及墻體接逢處不得有漏雨、滲水等缺陷。8) 當(dāng)儀器站房建在空曠地帶時(shí),儀器站房必須安裝避雷設(shè)施。9) 站房應(yīng)設(shè)有排風(fēng)扇等通風(fēng)設(shè)施,以防止腐蝕性氣體對(duì)儀器及操作人員造成危害。10) 站房內(nèi)最好設(shè)有實(shí)驗(yàn)臺(tái)、洗手池、地漏等設(shè)施。11) 應(yīng)在建設(shè)初在指定位置將所需的采樣管、排水管、穿線管提前預(yù)埋好,并在管內(nèi)預(yù)穿鋼絲,以便穿引管線。應(yīng)保證排水通暢。12) 站房距采水點(diǎn)距離應(yīng)盡量的近,直線距離應(yīng)不大于15米,垂直落差不大于5米。13) 嚴(yán)禁在有易燃性物質(zhì)、易燃、易爆性氣體周圍建站房。儀器站房要遠(yuǎn)離腐蝕性氣體,以確保安全。14) 室內(nèi)應(yīng)備有自啟動(dòng)冷暖空調(diào),以保證儀器正常運(yùn)行的環(huán)境。15) 室內(nèi)應(yīng)按“配電要求”提前做好供電系統(tǒng)。16) 如需使用電話線聯(lián)網(wǎng),應(yīng)提前將電話線引入室內(nèi),關(guān)做好信號(hào)防雷。17) 室內(nèi)應(yīng)備要必要的照明設(shè)備及開關(guān)。18) 選擇采樣點(diǎn)應(yīng)滿足以下條件:水樣具有代表性,對(duì)水質(zhì)變化反應(yīng)靈敏,距水源較近。7.3配電要求1) 站房內(nèi)最好采用三相五線供電,入室處裝有配電箱,配電箱內(nèi)連接入室引線應(yīng)分別裝有三個(gè)單相15A空氣開關(guān)作為三相電源的總開關(guān),并安裝電源過壓、過載和漏電自動(dòng)保護(hù)裝置。A相配接3KW穩(wěn)壓電源,穩(wěn)壓電源輸出接兩個(gè)5孔220V/10A電源插座;B相用于空調(diào)、照明、排風(fēng)扇等??照{(diào)應(yīng)采用空調(diào)專用電源插座,并單獨(dú)從配電箱引線。C相接兩個(gè)5孔插座用于安裝施工、回流實(shí)驗(yàn)設(shè)備供電。2) 供電系統(tǒng)不能與電機(jī)等大功率設(shè)備共用。3) 站房內(nèi)供儀器及空調(diào)使用的線路單股橫截面積不得小于4mm2。4) 所提供的電源應(yīng)有良好的接地,接地電阻小于4。5) 所有室內(nèi)線路走線采用PVC材料護(hù)線槽或護(hù)線管保護(hù)。7.4管路準(zhǔn)備管路要求1) 管材應(yīng)選用優(yōu)質(zhì)PVC材料或聚氯乙烯材料,管路連接不應(yīng)有死角,應(yīng)用直通或45度彎頭,以便于穿引鋁塑復(fù)合管。2) 排水管應(yīng)有自然傾角,以便于廢水排出。3) 根據(jù)地區(qū)差別,預(yù)防管路在冬季凍結(jié),預(yù)埋管深度H要根據(jù)冬季地區(qū)冰凍厚度確定。如:石家莊H=0.7米,沈陽H=1.2米,哈爾濱H=1.5米。4) 對(duì)于裸露的管路,應(yīng)采用保溫棉、伴熱帶等保溫防凍措施。5) 進(jìn)水管1通徑為50mm。管內(nèi)穿牽引鋼絲。掩埋部分加保溫棉。6) 排水管2通徑為75mm。掩埋時(shí)應(yīng)有自然傾角,以便于廢水排出。7) 進(jìn)線管3、4、5,管內(nèi)穿牽引鋼絲。8) 6為自來水上水管。9) 預(yù)埋管的另一端應(yīng)留在流量槽后端附近7.5巴歇爾流量槽概要7.51流量測(cè)量原理1)測(cè)量原理:用明渠測(cè)流量時(shí),在明渠上安裝量水堰槽。量水堰槽把明渠內(nèi)流量的大小轉(zhuǎn)成液位的高低。利用超聲波傳感器測(cè)量量水堰槽內(nèi)的水位,再按相應(yīng)量水堰槽的水位-流量關(guān)系反算出流量。7.5.2巴歇爾槽現(xiàn)場(chǎng)安裝平面示意圖(圖1)7.5.3 巴歇爾槽構(gòu)造(圖2)7.5.4巴歇爾槽構(gòu)造尺寸(表一)單位:米類別序號(hào)喉道段收縮段擴(kuò)散段墻高bNB1L1LaB2L2KD 小 型10.0250.0760.0290.1670.3560.2370.0930.2030.0190.2320.0510.1140.0430.2140.4060.2710.1350.2540.0220.263 0.0760.1520.0570.2590.4570.3050.1780.3050.0250.4640.1520.3050.1140.4000.6100.4070.3940.6100.0760.6150.2280.3050.1140.5750.8640.5760.3810.4570.0760.77標(biāo)準(zhǔn)型60.250.600.230.781.3250.8830.550.920.080.8070.300.600.230.841.3500.9020.600.920.080.9580.450.600.231.021.4250.9480.750.920.080.9590.600.600.231.201.5001.00.900.920.080.95100.750.600.231.381.5751.0531.050.920.080.95110.900.600.231.561.6501.0991.200.920.080.95121.000.600.231.681.7051.1391.300.920.081.0131.200.600.231.921.8001.2031.500.920.081.0141.500.600.232.281.951.3031.800.920.081.0151.800.600.232.642.101.3992.100.920.081.0162.100.600.233.002.251.5042.400.920.081.0172.400.600.233.362.401.6042.700.920.081.0大型183.050.910.3434.764.271.7943.681.830.1521.22193.660.910.3435.614.881.9914.472.440.1521.52204.571.220.4577.627.622.2955.593.050.2291.83216.101.830.6869.147.622.7857.323.660.3052.13227.621.830.68610.677.623.3838.943.960.3052.13239.141.830.68612.317.933.78510.574.270.3052.132412.191.830.68615.488.234.78513.824.880.3052.132515.241.830.68618.538.235.77617.276.100.3052.135)巴歇爾槽水位-流量公式(表2)類別序號(hào)喉道寬度b(m)流量公式Q=Chan(L/S)水位范圍h(m)流量范圍Q(L/S)臨界淹沒度%最小最大最小最大小型10.02560.4ha1.550.0150.210.095.40.520.051120.7ha1.550.0150.240.1813.20.530.076177.1ha1.550.030.330.7732.10.540.152381.2ha1.540.030.451.50111.00.650.228535.4ha1.530.030.602.52510.6標(biāo)準(zhǔn)型60.25561ha1.5130.030.603.02500.670.30679ha1.5210.030.753.54000.680.451038ha1.5370.030.754.56300.690.601403ha1.5480.050.7512.58500.6100.751772ha1.5570.060.7525.011000.6110.902147ha1.5650.060.7530.012500.6121.002397ha1.5690.060.8030.015000.7131.202904ha1.5770.060.8035.020000.7141.503668ha1.5860.060.8045.025000.7151.804440ha1.5930.080.8080.030000.7162.105222ha1.5990.080.8095.036000.7172.406004ha1.6050.080.80100.040000.7大型183.057463ha1.60.091.07160.082800.8193.668859ha1.60.091.37190.0146800.8204.5710960ha1.60.091.67230.0250400.8216.1014450ha1.60.091.83310.0379700.8227.6217940ha1.60.091.83380.0471600.8239.1421440ha1.60.091.83460.0563300.82412.1928430ha1.60.091.83600.0747000.82515.2435410ha1.60.091.83750.0930400.87.6流量槽的選擇與安裝1) 根據(jù)本企業(yè)最大瞬時(shí)排水量查“表2”,確定需要選擇的流量槽“序號(hào)”。2) 根據(jù)所查到的槽號(hào),按槽的最大寬度-“表1”中的“B1”規(guī)范排放的渠寬,既排水渠的寬度不能小于“B1”。3) 量水堰槽的中心線要與渠道的中心線重合,使水流進(jìn)入量水堰槽不出現(xiàn)偏流。4) 量水堰槽通水后,水的流態(tài)要自由流。臨界淹沒度可在表2查得。既要求流量槽后的排水要通暢。5) 量水堰槽的上游應(yīng)有大于5倍渠道寬的平直段,使水流能平穩(wěn)進(jìn)入量水堰槽。即沒有左右偏流,也沒有渠道坡降形成的沖力。6) 量水堰槽安裝在渠道上要牢固。與渠道側(cè)壁、渠底連結(jié)要緊密,不能漏水。使水流全部流經(jīng)量水堰槽的計(jì)量部位,量水槽的計(jì)量部位是槽內(nèi)喉道段。7) 巴歇爾槽水位觀測(cè)點(diǎn)在距喉道2/3收縮段長位置(圖2的La)。8) 巴歇爾槽安裝時(shí)應(yīng)保證圖2中水位零點(diǎn)處于水平狀態(tài)。9) 浮子采樣器可根據(jù)現(xiàn)場(chǎng)情況安裝的流量槽的上游或下游。7.7需用戶提前準(zhǔn)備的物品1)必備:蒸餾水50L,分析純硫酸3000ml,5000ml大燒杯,玻璃棒500mm。2)應(yīng)備:刻度吸管10ml、5ml各一只,吸耳球一只,1000ml、250ml量筒各一只,、洗瓶各一個(gè),容量瓶100ml需4個(gè),防酸手套一付。8.現(xiàn)場(chǎng)操作8.1準(zhǔn)備工作1) 整機(jī)檢查開機(jī)前對(duì)照產(chǎn)品裝箱單檢查各部件及配件是否完好、齊全。如損壞或短缺,應(yīng)及時(shí)修復(fù)或更換。注:不允許帶電拆裝設(shè)備。2)檢查各管路連接是否正確,連接是否可靠,管材是否與要求相符(注意區(qū)分氟膠管和硅膠管兩種材質(zhì))。3)檢查電源插座,應(yīng)符合左零右火的規(guī)范,并且地線接觸良好。8.2配制試劑試劑配制與分裝:(1) 為便于運(yùn)輸和攜帶,所供試劑為固體試劑。(2) 配制操作請(qǐng)?jiān)谕L(fēng)條件下進(jìn)行,配制人員必須穿戴防酸服、防酸手套。配制前先請(qǐng)用蒸餾水將試劑瓶、計(jì)量器清洗干凈。注意:試劑配制好后,必須放置48小時(shí),且在放置的過程中要搖動(dòng)35次,以便試劑充分溶解混合。(3) 試劑分低濃度試劑和高濃度試劑兩種,每種試劑都分為A、B兩部分(詳見實(shí)際瓶包裝),包裝均為500個(gè)樣,配制方法如下:a) 低濃度試劑的配制方法:配制比例如下:固體試劑蒸餾水(ml)硫酸(分析純ml)A(純白色)02500B(棕白色)45050將固體試劑A(催化劑)全部放入5000ml試劑瓶中,加入2500ml 98%分析純濃硫酸,用玻璃棒攪拌均勻。將固體試劑B(氧化劑)全部放入1000ml燒杯中,加入450ml蒸餾水,然后緩慢加入50ml 98%分析純濃硫酸,用玻璃棒攪拌均勻。b) 高濃度試劑的配制方法:配制比例如下:固體試劑蒸餾水(ml)硫酸(分析純ml)A(純白色)02500B(棕白色)47030將固體試劑A(催化劑)全部放入5000ml試劑瓶中,加入2500ml 98%分析純濃硫酸,用玻璃棒攪拌均勻。將固體試劑B(氧化劑)全部放入1000ml燒杯中,加入470ml蒸餾水,然后緩慢加入30ml 98%分析純濃硫酸,用玻璃棒攪拌均勻。注意事項(xiàng):(1)、本儀器使用的試劑具有強(qiáng)酸性、強(qiáng)氧化性,在操作本儀器時(shí)請(qǐng)配戴必要的防酸用具,謹(jǐn)防意外燒傷。(2)、嚴(yán)格按說明書所要求的比例配置。(3)、所用蒸餾水最低為二級(jí)蒸餾水,最好為重蒸餾水。因?yàn)檎麴s水對(duì)低濃度COD的準(zhǔn)確性測(cè)量影響尤其明顯。(4)、添加蒸餾水與硫酸的次序不能顛倒,一定要先加蒸餾水再加硫酸。附:GB6682-1992分析實(shí)驗(yàn)室用水規(guī)格8.3將液體試劑和蒸餾水分別注入試劑瓶和蒸餾水箱,注完后請(qǐng)及時(shí)將瓶塞和箱蓋蓋好,液位不低于2/3箱高。8.4往冷卻箱中注入蒸餾水或自來水(自來水不影響冷卻效果,但會(huì)在管壁結(jié)水垢),液位不低于1/3箱高。8.5連接采樣管路。8.6連接主機(jī)污水排放管路,將其出口置于下水道。注意:排放口應(yīng)低于主機(jī)底板且廢液排放管不要超過2米。8.7連接廢液箱及主機(jī)進(jìn)水管路。8.8連接信號(hào)線(適配器用)及電話線。8.9連接好主機(jī)電源。9系統(tǒng)調(diào)試9.1閥體的調(diào)試1)將空氣開關(guān)、電源開關(guān)置于ON的狀態(tài),測(cè)量電源插頭L、N之間的電阻,應(yīng)在105歐左右。2)分別按進(jìn)樣閥、蒸餾水、消解閥、冷卻閥、比色閥鍵,觀察相應(yīng)閥是否動(dòng)作,閥芯應(yīng)活動(dòng)自如,液體流動(dòng)順暢,閥體密封可靠。注:當(dāng)冷卻閥中有液體下排時(shí),應(yīng)先將比色閥排空,以免比色閥溢出。9.2 冷卻泵的調(diào)試1)確認(rèn)冷卻水箱內(nèi)已注入蒸餾水。按冷卻泵鍵,冷卻水應(yīng)從冷卻閥水套下端進(jìn)入,上端排出。水流快速通暢,泵電機(jī)運(yùn)轉(zhuǎn)平穩(wěn)無雜音。2)再按冷卻泵鍵,冷卻泵關(guān)閉。.3 其它部件調(diào)試)按溫控儀鍵,溫控儀打開,溫度顯示正常,并能將溫度控制在(1652)范圍內(nèi)。再按此鍵,溫控儀關(guān)閉。)按光度計(jì)鍵,光度計(jì)打開,光度計(jì)發(fā)光管亮。再按此鍵,光度計(jì)關(guān)閉。)按自吸泵鍵,自吸泵啟動(dòng),有水循環(huán)流經(jīng)管路,查看管路是否漏水,按進(jìn)樣閥查看進(jìn)樣是否順暢。再按此鍵,泵停止。9.4試劑計(jì)量管的調(diào)節(jié)1)雙擊手動(dòng)按鍵,使儀器處于手動(dòng)工作狀態(tài)。在“按鍵監(jiān)控”畫面中按1ml試劑鍵,1ml試劑閥(二位三通閥)動(dòng)作,棕色氧化劑由試劑瓶緩緩注入計(jì)量管,當(dāng)液面到達(dá)光電檢測(cè)位置后,試劑閥自動(dòng)復(fù)位,1ml試劑由排液口排到消解閥中。2)調(diào)節(jié)計(jì)量板上控制1ml試劑 電位器W1,在無試劑的情況下,使發(fā)光二極管由滅到亮,由亮到滅,反復(fù)多次,滅與亮旋轉(zhuǎn)幅度最小,使精度最高,3)計(jì)量1ml試劑,按1ml試劑鍵,液體進(jìn)入計(jì)量杯,調(diào)節(jié)槽型光藕位置,同時(shí)調(diào)節(jié)W1,使二極管亮,同時(shí)閥斷電,液體從排液口排出,這時(shí)計(jì)量板二極管燈滅,取樣匙接取從排液口排出的試劑,用移液管計(jì)量排出的量,一次排出液體的量應(yīng)為1.00.2ml。連續(xù)計(jì)量6次,最大變化輻度在0.05 ml。4)5ml計(jì)量杯調(diào)試 方法同3.3.1,計(jì)量范圍:50.5ml,最大輻度:0.1ml。9.5倒進(jìn)樣計(jì)量杯調(diào)試在“按鍵監(jiān)控”畫面按進(jìn)樣鍵,電磁閥打開,水樣從左邊進(jìn)入計(jì)量杯,用量桶從左邊嘴子出口接取,計(jì)量范圍:2.30.3ml;計(jì)量六次,最大輻度:0.1ml。9.6發(fā)射、接收光路調(diào)試觀察發(fā)射二極管610nm、430nm發(fā)光顏色。用白色紙條置于比色池中部,應(yīng)能觀察到橙色光斑或藍(lán)色光斑,仔細(xì)觀察發(fā)射光是否直接對(duì)準(zhǔn)接收光源,并且發(fā)射、接收管在同一水平位置。9.7溫控儀的調(diào)試9.7.1按溫控儀鍵,溫控儀打開;再次按鍵,溫控儀關(guān)閉(如下圖)。1)視窗、燈號(hào)說明PV-目前溫度及參數(shù)代號(hào)視窗SV-設(shè)定值及參數(shù)值顯示窗AT自動(dòng)演算指示燈MA手動(dòng)輸出指示燈A1第一組警報(bào)輸出指示燈A2第二組警報(bào)輸出指示燈C1第一組控制輸出指示燈C2第二組控制輸出指示燈2)按鍵說明 -切換下一組參數(shù)功能或按住五秒持溫計(jì)時(shí)timer reset -累加參數(shù)設(shè)定值 -遞減參數(shù)設(shè)定值 -移位鍵:按住5秒鐘可執(zhí)行自動(dòng)演算YES.1模式,執(zhí)行中如需停止演算,按住5秒鐘即可停止 +-鍵一次,即可立刻回到主界面 +-鍵五秒,即可進(jìn)入階層參數(shù),此時(shí)按或鍵可以選擇階層,再按鍵即可進(jìn)入該階層9.7.1操作步驟: 1)按住+鍵5秒后進(jìn)入SOFT LEVEL,或鍵選擇SOFT(斜率/緩啟動(dòng))階層,再按鍵即可進(jìn)入該階層第一階段(LEVL)參數(shù)設(shè)置:(按使PV中的參數(shù)進(jìn)行切換,按鍵進(jìn)行移位,按或鍵進(jìn)行設(shè)置,最后再按進(jìn)行確認(rèn)修改)- 第一組報(bào)警值: 設(shè)置為 160- 第二組報(bào)警值: 設(shè)置為1852) 通過連續(xù)按鍵,或鍵選擇PID(比例/積微分)階層,進(jìn)入第二階段(PID)參數(shù)設(shè)置:(按使PV中的參數(shù)進(jìn)行切換,按鍵進(jìn)行移位,按或鍵進(jìn)行設(shè)置,最后再按進(jìn)行確認(rèn)修改) - 第一組比例輸出: -積分時(shí)間:-微分時(shí)間: -第一組輸出周期: 15s (表示繼電器輸出類型)-第二組比例輸出:-加熱冷卻不感帶:此階段的參數(shù)設(shè)置需要輸入一組PID控溫較好的參數(shù),如果控溫性能不好,按步驟4)得到一組性能較好的參數(shù). 3)通過連續(xù)按鍵,或鍵選擇OPTI(操作)階層,進(jìn)入第二階段(OPTI)參數(shù)設(shè)置:(按使PV中的參數(shù)進(jìn)行切換,按鍵進(jìn)行移位,按或鍵進(jìn)行設(shè)置,最后再按進(jìn)行確認(rèn)修改) -選擇傳感器類型:D-PT (表示PT100)-單位選擇: -小數(shù)位數(shù):000.0 (表示1位小數(shù))-加熱或冷卻控制: rEv ( rEv表加熱,dir表示冷卻)-使用范圍下限: 0-使用范圍上限: 200 -第一組報(bào)警方式: 設(shè)置為 Hi (上限報(bào)警) -第二組報(bào)警方式:設(shè)置為 Hi (上限報(bào)警)-第一組警報(bào)不感帶: 0.1-第二組警報(bào)不感帶: 0.1-ON/OFF控制不感帶: 0.1-測(cè)定值偏差修正: 0 3) 連續(xù)按住鍵,5S后自動(dòng)演算控制燈AT閃爍,使儀器開始自動(dòng)演算得到一組較好PID參數(shù)。注意:儀器自動(dòng)演算時(shí)間比較長,如果再連續(xù)按住鍵,5S后將結(jié)束自動(dòng)演算功能。5)+鍵將返回到設(shè)定點(diǎn)。按或鍵將SV的值設(shè)置為165.0表示控制目標(biāo)溫度為165。(4) 觀察溫控儀溫升,升溫應(yīng)平穩(wěn),控溫范圍在1652之間。(5) 關(guān)閉溫控儀,在流程電路板上改變鉑電阻跳線,重新開啟溫控儀,溫度顯示應(yīng)無明顯差別,控溫依然正常。9.8氣泵調(diào)試一、 在“按鍵監(jiān)控”畫面按氣泵鍵,用手感覺氣泵兩個(gè)出口有氣流。99 2AD模塊的調(diào)試 在“高級(jí)設(shè)定”畫面中選擇“使用流量計(jì)” 將直流穩(wěn)壓電源與主控板“25、26”端子相連,穩(wěn)壓電源的正極與端子“25”相連,穩(wěn)壓電源的負(fù)極與端子“26”相連。 調(diào)節(jié)直流穩(wěn)壓電源輸出,使輸出電壓為5.000V,在“數(shù)據(jù)記錄”畫面中觀察“AD1”,調(diào)節(jié)2AD模塊的“GAIN”電位器,使AD1的示值為4000。 調(diào)節(jié)穩(wěn)壓電源輸出,使輸出電壓為0.2500V,調(diào)節(jié)2AD模塊的“OFFSET”電位器,使AD1為200。 重復(fù)上述兩個(gè)步驟兩到三次。 調(diào)節(jié)使穩(wěn)壓電源輸出為2.500V,觀察AD1,應(yīng)在20005范圍內(nèi)。否則重復(fù)2、3步。9.10 2DA模塊的調(diào)試 在DA類型中選擇“2DA”。 將萬用表旋至電流檔(表筆插孔也做相應(yīng)變動(dòng)),串聯(lián)一只250歐接于電路板的2DA-1兩接線端。 將“COD量程系數(shù)”設(shè)為4,將“當(dāng)前值”設(shè)為1000,按啟動(dòng)轉(zhuǎn)換,調(diào)節(jié)“CH1 GAIN”,使萬用表示值為20.00mA。 將“當(dāng)前值”設(shè)為0,按啟動(dòng)轉(zhuǎn)換鍵,調(diào)節(jié)“CH1 OFFSET”,使萬用表示值為4.000mA。 重復(fù)上述兩個(gè)步驟2至3次。 將當(dāng)前值設(shè)為500,按啟動(dòng)轉(zhuǎn)換,萬用表示值應(yīng)在12.0000.005mA。否則重新調(diào)節(jié)。.1.1.1 流量值的2DA調(diào)試 在DA類型中選擇“2DA”。 將萬用表旋至電流檔(表筆插孔也做相應(yīng)變動(dòng)),串聯(lián)一只250歐接于電路板的2DA-2兩接線端。 啟動(dòng)“人工轉(zhuǎn)換”鍵使流量DA輸出處于人工轉(zhuǎn)換狀態(tài)。 將“20mA流量值”暫設(shè)為1.0000000m3/s。(到現(xiàn)場(chǎng)與適配器相連時(shí)需根據(jù)流量槽的最大流量值進(jìn)行修改,)。 將“當(dāng)前流量”設(shè)為1.000000m3/s,按啟動(dòng)轉(zhuǎn)換,調(diào)節(jié)“CH2 GAIN”,使萬用表示值為20.00mA。 將“當(dāng)前流量”設(shè)為0.000000m3/s,按啟動(dòng)轉(zhuǎn)換鍵,調(diào)節(jié)“CH2 OFFSET”,使萬用表示值為4.000mA。 重復(fù)上述兩個(gè)步驟2至3次。 將當(dāng)前值設(shè)為0.5000000m3/s,按啟動(dòng)轉(zhuǎn)換,萬用表示值應(yīng)在12.0000.005mA。否則重新調(diào)節(jié)。 按“人工轉(zhuǎn)換”鍵取消人工轉(zhuǎn)換,恢復(fù)正常輸出。 調(diào)試完畢。其它說明:1)、與適配器相連時(shí),2DA-1、2DA-2接線端子左為“+”是420mA的正極輸出,接適配器的“+”端。另一端為“-”,接適配器的“-”。2)、在現(xiàn)場(chǎng)與適配器相連時(shí),如果萬用表的電流檔損壞,可先用萬用表測(cè)量適配器420mA輸入端電阻,用測(cè)量電壓的方式計(jì)算電流輸出。3)輸出電流值=(當(dāng)前值/滿量程值)16+4mA9.11 高級(jí)調(diào)試9.11.1數(shù)據(jù)記錄 AD1第一路AD的實(shí)時(shí)值,每0.1秒轉(zhuǎn)換一次,代表液位的高低。如果安好超聲波液位計(jì),則AD=(h測(cè)+0.2)4000h測(cè)=(AD/40000.2)m AV代表100個(gè)AD1的平均值。注:必須在高級(jí)設(shè)定中啟動(dòng)“使用流量計(jì)”AD1才有效。 系統(tǒng)時(shí)間當(dāng)前時(shí)刻。 修正前值與真實(shí)COD值有著線性關(guān)系的中間變量,從一定意義上代表吸光度。 修正后值指修正前值按照設(shè)定的線性公式計(jì)算后得到的值,代表COD值,與測(cè)試畫面中顯示的當(dāng)前COD值相同。當(dāng)啟用平滑時(shí),因經(jīng)過線性計(jì)算后的COD值又經(jīng)過了平滑計(jì)算,可能會(huì)出現(xiàn)修正后值不按線性走的現(xiàn)象。 測(cè)試AD1上次的“測(cè)試AD”記錄值; 測(cè)試AD2指當(dāng)比色閥中有測(cè)試液體時(shí)的AD值,代表比色閥中有測(cè)試液時(shí)的透光強(qiáng)度,此值越大,說明透光強(qiáng)度越大,COD值越小。 校百AD當(dāng)比色閥中為蒸餾水(COD值為0,光100%通過)時(shí)的AD值,此值應(yīng)該是一個(gè)比較大且穩(wěn)定的值,當(dāng)此值出現(xiàn)較大波動(dòng)時(shí),說明比色閥需要清洗,或者發(fā)射、接收孔的相對(duì)位置不在同一水平面。 實(shí)時(shí)AD啟動(dòng)AD轉(zhuǎn)換時(shí)(主機(jī)自動(dòng)啟動(dòng)或人為強(qiáng)制啟動(dòng))第二路AD的實(shí)時(shí)值(代表光度計(jì)透光強(qiáng)度)。AV代表100個(gè)實(shí)時(shí)AD的平均值。在測(cè)試狀態(tài),此平均值賦給“測(cè)試AD”,在校百狀態(tài),此平均值賦給“校百AD”。 啟動(dòng)AD轉(zhuǎn)換人為強(qiáng)制進(jìn)行AD轉(zhuǎn)換,在進(jìn)行轉(zhuǎn)換前,在比色池放入蒸餾水,啟動(dòng)AD轉(zhuǎn)換,調(diào)節(jié)光度計(jì)板的電位器W1,使數(shù)據(jù)記錄界面上實(shí)時(shí)AD顯示3300。 中止記錄用于在現(xiàn)場(chǎng)給用戶做線性標(biāo)定時(shí),為防止用高濃度標(biāo)液標(biāo)定時(shí),數(shù)據(jù)記錄中記錄下高濃度COD值,給用戶帶來不必要的麻煩而設(shè)計(jì)。啟用此鍵后,數(shù)據(jù)將不再記入數(shù)據(jù)記錄。9.11.2線性校正9.11.2.1畫面介紹由于儀器特點(diǎn)、測(cè)量方法及水樣多樣性等問題,造成標(biāo)液線性與實(shí)際水樣線性不一致。由此產(chǎn)生了標(biāo)液線性與水樣線性兩種線性。在圖中的三條線性中,每條線性都可獨(dú)立使用,第一、二線性還可同時(shí)使用(后面有詳細(xì)介紹)。一般將第一、二線性作為水樣線性,將第三線性作為標(biāo)樣線性。儀器按哪條線性計(jì)算,由哪條線性底色為紅色決定。下面以第三線性為例介紹區(qū)間、線性、上下限的確定。9.11.2.2 a3、b3的確定在“數(shù)據(jù)記錄”畫面中啟用“人工測(cè)試”,測(cè)試周期設(shè)為20分鐘,采樣方式設(shè)為“測(cè)試前采樣”,在“按鍵監(jiān)控”畫面中雙擊“自動(dòng)”鍵進(jìn)入自動(dòng)運(yùn)行狀態(tài)。第一次加入標(biāo)液是在溫控儀溫度到165后,空白樣進(jìn)入冷卻閥前添加,加液方法為:用移液管將34ml標(biāo)樣加入到水樣計(jì)量池中。此后的加液在整個(gè)測(cè)試過程完成(比色閥排空)后,下一個(gè)周期啟動(dòng)前添加。添加后注意觀察水樣計(jì)量池是否能將多余的水樣溢流出去。在每次測(cè)量完畢,請(qǐng)將修正前值、測(cè)試AD、校百AD如實(shí)記錄,并記錄加入的標(biāo)樣值,填入“調(diào)試記錄”中。要求每種標(biāo)樣至少測(cè)量三次。數(shù)據(jù)處理如下:(在數(shù)據(jù)處理前應(yīng)將明顯的粗大誤差值去除)修正前值149168211344560152169214341558147166213
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- ××超市照明設(shè)備細(xì)則
- 2025年烘焙師職業(yè)資格考試烘焙師職業(yè)發(fā)展規(guī)劃與案例分析試題卷
- 春天你終于來了抒情散文12篇
- 小朋友們一起植樹寫事作文14篇范文
- 鋼鐵行業(yè)綠色轉(zhuǎn)型與2025年產(chǎn)能布局優(yōu)化產(chǎn)業(yè)轉(zhuǎn)型升級(jí)路徑研究報(bào)告
- 工業(yè)搬遷項(xiàng)目2025年對(duì)區(qū)域社會(huì)安全穩(wěn)定影響風(fēng)險(xiǎn)評(píng)估報(bào)告
- 學(xué)校運(yùn)動(dòng)會(huì)事件對(duì)我的啟發(fā)議論文12篇
- 人力資源管理效能證明書(5篇)
- 最難忘的一句話話題作文7篇
- 網(wǎng)絡(luò)維護(hù)技術(shù)服務(wù)合同協(xié)議
- 骨科手術(shù)后的康復(fù)輔助器具和輔助裝置
- 新員工企業(yè)文化培訓(xùn)
- 學(xué)校課程體系建設(shè)與調(diào)整情況匯報(bào)
- 2024年江西吉安市城投公司招聘筆試參考題庫含答案解析
- 鐵路路基施工與維護(hù)習(xí)題集
- 農(nóng)產(chǎn)品安全生產(chǎn)技術(shù)
- 電器整機(jī)新產(chǎn)品設(shè)計(jì)DFM檢查表范例
- 《公路路基路面現(xiàn)場(chǎng)測(cè)試規(guī)程》(3450-2019)
- 2021年機(jī)電一體化專業(yè)技能考試(山東省春季高考)試題
- 商業(yè)保理業(yè)務(wù)法律風(fēng)險(xiǎn)與規(guī)避
- 國家開放大學(xué)《中國現(xiàn)代文學(xué)專題》形考任務(wù)1-4參考答案
評(píng)論
0/150
提交評(píng)論