1、ACC20主機控制系統(tǒng)一、系統(tǒng)簡介青島QBC8.2系列船主機為5RT-FLEX 58T-D,主機遙控為KONGSBERGACC-20,下圖是集控式主機操作面板,左邊是遙控系統(tǒng)操作窗口,右邊是車鐘。顯示器下面的6個功能按鈕,從左到右分別為:1. Cancel SHD,2. Cancel SLD,3. Cancel Limits,4. In command,集控式控制時此燈點亮,駕控和機旁控制時滅。5. Sound off,6. Alarm ack車鐘下面有7個功能指示按鈕+1個車鐘錯向報警左邊從上到下分別為1. Bridge2. ECR3. Local用于控制位置轉(zhuǎn)換中間位置1. Wrong W
2、ay 2. Emer. Stop右邊從上到下分別為1. At sea2. Stand By3. FWE用于指示主機狀態(tài)下圖為主機在額定轉(zhuǎn)速93RPM時Home頁(主頁)圖片下圖是對顯示器各部分畫面顯示功能的展開,主機在不同的狀態(tài),顯示的內(nèi)容給出實時狀態(tài)指示。二、主要菜單構(gòu)建首要說明:1 在Home頁,通過旋轉(zhuǎn)和按壓鼠標手輪可以選擇進入各下一級菜單,如下樹形圖; 2 如有警報發(fā)生,菜單前面的指示燈會由正常的灰色變?yōu)榱良t色,以示提醒。第4層,警報查看AlarmsSys. Critical Sys. Non-Crit. ComErr Crit ComErr Non-Crit I/O Fail Ala
3、rm History旋轉(zhuǎn)首輪直到菜單頂部顯示PUSH WHEEL TO ENTER LIST進入;退出是方向旋轉(zhuǎn)手輪,直到菜單頂部顯示PUSH WHEEL TO LEAVE LIST退出。第2層,限制查看LimitersSet LimitersChief RPM Limiter 輪機長轉(zhuǎn)速限制 Manual Fuel Limiter 手動油量限制 Lim Curves查看兩個限制曲線Fuel Limit/Charge Air和Fuel Limit/Rpm,“X”顯示當前運行狀態(tài) Show LimitersRPM LIMITER FUEL LIMITERS Show Slowdown Torqu
4、e Limiter Start Setpoint Limit Charge Air Limiter Acceleration Limit Manual Fuel Limiter Speed Program Up Speed Program Down Critical RPM Setpoint Chief LimiterMinimum Run 前部指示燈如果點亮,說明哪個限制在起作用,正常為灰色。 Speed ProgramSpeed Up Program Active Speed Down Program Active Cancel Speed Program 如果指示燈變綠,程序負荷取消 R
5、emaining Time(僅顯示程序負荷剩余時間,不可修改)本輪程序負荷從50RPM開始,結(jié)束于93RPM;程序加速總時間為60分鐘,程序降速時間為加速時間減半。程序加速時間具體分布如下:50-65RPM-0.1M65-70RPM-0.5M70-85RPM-19,4M85-93RPM-40M降速時如果車鐘手柄拉到63RPM時,系統(tǒng)自認為是緊急情況,轉(zhuǎn)速直接下降,負荷程序取消。第1層,柴油機狀態(tài)查看Engine StateEngine stateSTATE START FAIL/BLOCK ENGINE NOT READY Start Interlock 3 Start Failure Tur
6、ning Gear Engaged Ready For Start Brake Time Limit Starting Air Valve Man. Closed Slow Turning Start Time Limit Comm. Error DGU-WECS Starting Engine Tripped Safety System Off Repeated Start Rpm Detector Fail Running Engine Not Ready Stopping All Aux Blower Failure Engine Tripped Start Air Pressure L
7、ow前部指示燈指示當前主機狀態(tài) User ProgramChief Rpm Limiter Manual Fuel Limiter 上述限制和Limiters中的SetLimiters限制一樣,兩處都可修改。 WECS Comm查看狀態(tài) DGUWECS SSUWECS RCSWECS WECSDGU第5層,雜項查看Misc MenuEngine Data(顯示主機銘牌參數(shù)) Dimming (調(diào)整背景光,可選擇手動或自動) Date&Time (設(shè)置時間,但目前系統(tǒng)與子母鐘相連,自動跟隨駕駛臺時間設(shè)置) User Access (進入后可更改相應(yīng)級別密碼) (第5.1層) WECS 9520進
8、入WARTSILA flexView系統(tǒng),功能和裝在Kyma電腦中的flexView相同 WECS INDIC WECS USER (可進行單缸停油、油頭驅(qū)氣、排氣閥開關(guān)試驗、主啟動電磁閥試驗等操作) WECS ADJUST (可進行相關(guān)參數(shù)調(diào)整) WECS INJ-QTY WECS INJ-TIME WECS EXHV-P WECS EXHV-T WECS CYL. LUBR(可進行注油率調(diào)整和啟動前的預(yù)潤滑) Param. ChangeSTART STOP REVESINGSLOW TURNING Delay of slow turn request (30M) Make slow tur
9、n time (30S) Slowturn overspeed Threshold low (5rpm) Slowturn overspeed Threshold high (40rpm) NORMAL START Page 1 of 2 Tag: RPMStart Threshold Low (8.0rpm) Start Threshold Normal (11.0rpm) Start time limit (8s) Start time limit CAS (0s) Engine running delay (5s) Restart inhibit delay (10s) Limit no
10、. of start (3) Start setpoint (stabilizing) level (40rpm) Page 2 of 2 Tag: RPM Ramp down rate (10.0 rpm) Stabilizing time (10s) Engine Standstill Threshold (5.0 rpm) Disable Preload (Yes) HEAVY STARTStart Threshold heavy start (13.0rpm) Heavy start after brake (5s) Heavy start reset time (60s) Heavy
11、 start on cancel limiters (0) Heavy start on crash astern (1) REVESINGBrake Threshold low (20rpm) Brake Threshold high (38rpm) Brake time limit (8s) CRASH ASTERNEnable Crash Astern above this limit (90.0) Active Crash Astern below this limit (-85.0) Reset Crash Astern above this limit (-60.0) Lever
12、move time (2s) START AIR PRESSUREStart air pressure threshold low (7bar) Start air pressure threshold high (8bar) FUEL START SETPNormal Start Fuel setp. (20.0) Heavy Start Fuel setp. (25.0) Start Fuel set point timeout (10.0s) SAFETYSHUT DOWN Page 1 of 9 Tag: Engine Tripped Fuel shut down valve open
13、 time (60s) Input tag ref #1 OVERSPEED FROM RPM UNIT Over speed level (101.0rpm) Alarm on delay (0s) Input tag ref #2 Main bearing oil press low low Channel No.2 cancellable (0) Channel No.2 pre-warning time (0s) Alarm on delay (2s) Page 2 of 9 Tag: Engine Tripped Input tag ref #3 Air Spring Press L
14、ow Channel No.3 cancellable (1) Channel No.3 pre-warning time (10s) Alarm on delay (2s) Input tag ref #4 Cylinder Cooling Water Press Low Channel No.4 cancellable (1) Channel No.4 pre-warning time (60s) Alarm on delay (2s)Page 3 of 9 Tag: Engine Tripped Input tag ref #5 Thrust Bearing LO Out. Temp.
15、hi Channel No.5 cancellable (1) Channel No.5 pre-warning time (60s) Alarm on delay (1s) Input tag ref #6 Turbocharger #1 Oil press low Channel No.6 cancellable (1) Channel No.6 pre-warning time (5s) Alarm on delay (2s)Page 4 of 9 Tag: Engine Tripped Input tag ref #7 PCO NO FLOW CYL.1 Channel No.7 ca
16、ncellable (1) Channel No.7 pre-warning time (15s) Alarm on delay (2s) Input tag ref #8 PCO NO FLOW CYL.2 Channel No.8 cancellable (1) Channel No.8 pre-warning time (15s) Alarm on delay (2s) Page 5 of 9 Tag: Engine Tripped Input tag ref #9 PCO NO FLOW CYL.3 Channel No.9 cancellable (1) Channel No.9 p
17、re-warning time (15s) Alarm on delay (2s) Input tag ref #10 PCO NO FLOW CYL.4 Channel No.10 cancellable (1) Channel No.10 pre-warning time (15s) Alarm on delay (2s)Page 6 of 9 Tag: Engine Tripped Input tag ref #11 PCO NO FLOW CYL.5 Channel No.11 cancellable (1) Channel No.11 pre-warning time (15s) A
18、larm on delay (2s)Page 7 of 9 Tag: Engine Tripped Input tag ref #10 EMERGENCY STOP LOCAL Channel No.10 cancellable (0) Channel No.10 pre-warning time (0s) Alarm on delay (0s) Page 8 of 9 Tag: Engine Tripped Input tag ref #11 EMERGENCY STOP ENGINE CTRL ROOM Channel No.11 cancellable (0) Channel No.11
19、 pre-warning time (0s) Alarm on delay (0s) Input tag ref #12 EMERGENCY STOP SWITCH BRIDGE Channel No.12 cancellable (0) Channel No.12 pre-warning time (0s) Alarm on delay (0s)Page 9 of 9 Tag: Engine Tripped Input tag ref #15 OVERSPEED SYS.1-SW BACKUP Channel No.15 cancellable (0) Channel No.15 pre-w
20、arning time (0s) Alarm on delay (0s) Input tag ref #16 OVERSPEED SYS.2-SW BACKUP Channel No.16 cancellable (0) Channel No.16 pre-warning time (0s) Alarm on delay (0s) SLOW DOWN Page 1 of 9 Tag: Slow Down Active Input tag ref #1 C F W INLET PRESS Channel No.1 cancellable (1) Channel No.1 pre-warning
21、time (60s) Alarm on delay (2s) Input tag ref #2 NO.1-5 CYL. COOLING W. OUTLET TEMP Channel no.2 cancellable (1) Channel no.2 Pre-warning time (60s) Alarm on delay (2s) Page 2 of 9 Tag: Slow Down Active Input tag ref #3 WECS PRESSURE FAILURE Channel No.3 cancellable (1) Channel No.3 pre-warning time
22、(60s) Alarm on delay (0s) Input tag ref #4 WECS CYLINDER FAILURE Channel No.4 cancellable (1) Channel No.4 pre-warning time (60s) Alarm on delay (0s) Page 3 of 9 Tag: Slow Down Active Input tag ref #5 MAIN LO SUPPLY PRESS Channel No.5 cancellable (1) Channel No.5 pre-warning time (60s) Alarm on dela
23、y (2s) Input tag ref #6 MAIN LO SUPPLY TEMP Channel No.6 cancellable (1) Channel No.6 pre-warning time (60s) Alarm on delay (2s) Page 4 of 9 Tag: Slow Down Active Input tag ref #7 THRUST BEARING LO OUT TEMP Channel No.7 cancellable (1) Channel No.7 pre-warning time (60s) Alarm on delay (2s) Input ta
24、g ref #8 NO.1-5 CYL PCO OUT TEMP Channel No.8 cancellable (1) Channel No.8 pre-warning time (60s) Alarm on delay (2s) Page 5 of 9 Tag: Slow Down Active Input tag ref #9 T/C LUB OIL IN PRESS Channel No.9 cancellable (1) Channel No.9 pre-warning time (60s) Alarm on delay (2s) Input tag ref #10 T/C LUB
25、 OIL OUT TEMP Channel No.10 cancellable (1) Channel No.10 pre-warning time (60s) Alarm on delay (2s) Page 6 of 9 Tag: Slow Down Active Input tag ref #11 Oil mist detector Conc. high Channel No.11 cancellable (1) Channel No.11 pre-warning time (60s) Alarm on delay (2s) Input tag ref #12 EXH. GAS AFTER
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
- 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025年個人房屋裝修合同樣本
- 2025合同模板會員入會合同細則范本
- 教育機構(gòu)中如何通過巖棉防火系統(tǒng)提升安全性
- 機械采購類供貨方案、售后方案(技術(shù)方案)
- 二零二四年圖書館圖書采購合同:高校圖書館外借服務(wù)協(xié)議3篇
- 合同授權(quán)委托管理制度
- 2025年湘教版選擇性必修1物理下冊月考試卷含答案
- 二零二五年度生態(tài)農(nóng)業(yè)綜合開發(fā)項目合同范本3篇
- 2025年人教新課標高一地理上冊月考試卷
- 2025年冀教新版九年級語文下冊月考試卷
- 五年級上冊寒假作業(yè)答案(人教版)
- 2025年山東浪潮集團限公司招聘25人高頻重點提升(共500題)附帶答案詳解
- 2024年財政部會計法律法規(guī)答題活動題目及答案一
- 2025年江西省港口集團招聘筆試參考題庫含答案解析
- (2024年)中國傳統(tǒng)文化介紹課件
- 液化氣安全檢查及整改方案
- 《冠心病》課件(完整版)
- 2024年云網(wǎng)安全應(yīng)知應(yīng)會考試題庫
- 公園保潔服務(wù)投標方案
- 光伏電站項目合作開發(fā)合同協(xié)議書三方版
- 2024年秋季新滬教版九年級上冊化學(xué)課件 第2章 空氣與水資源第1節(jié) 空氣的組成
評論
0/150
提交評論