1、空調(diào)錯誤格力:變頻柜機E1-E5E1 :壓機過流,過熱,排氣過高,模塊保護;E2:室內(nèi)防凍結(jié)保護;E3:室內(nèi)溫度感溫包開,短路;E4 :室內(nèi)管溫開,短路;E5 :室內(nèi)外通訊故障。:定頻機故障代碼:E1:壓縮機高壓保護E2:蒸發(fā)器防凍結(jié)保護 E3:壓縮機低壓保護E4:壓縮機排氣溫度過高保護 E5:過電流(低電壓保護)Gree: Freque ncy Guiji E1-E5E1: press overcurre nt, overheat ing, excessive exhaust,module protect ion;E2: in door an ti-freezeprotecti on;E3:

2、 in door temperaturethermal package ope n, short circuit;E4: in door pipe temperature ope n, short circuitE5: i ndoor and outdoor com muni cati on failure. : Fixed-freque ncymach ine fault codes:E1: Compressor high pressure protecti on E2: Evaporator an ti-freeze protect ion E3:compressor and low pr

3、essureprotect ionE4: compressor discharge temperatureprotecti on E5: over-curre nt (low voltage protecti on)E1是系統(tǒng)高壓保護。故障原理:外機銅管連接的有個高壓保護開關(guān),通過高壓開關(guān)檢測系統(tǒng)壓力,然后通過線路反饋給芯片。維修流程:1.首先排除外界因素,如蒸發(fā)器,冷凝器臟,電源缺相等。如果機器一開機就顯示E1,看壓縮機是否啟動,若沒啟動測量高壓開關(guān),若啟動測壓縮機啟動電流。2.機器開一段時間顯示E1,檢查高壓開關(guān),和線路??梢远探痈邏洪_關(guān)或OVC短接,排除某處的故障。E1:為壓縮機高壓保護

4、。1、冷凝器前有障礙物2 、室外環(huán)境溫度高于43度時開始制冷3、控制回路異常4 、高壓管壓力過大使高壓開關(guān)動作那么我們可以根據(jù)故障代碼含義來分析,一般出現(xiàn)此故障的故障部位為:室外機散熱不良、清洗即可。室外風(fēng)機不轉(zhuǎn)或轉(zhuǎn)的慢:決解方法,換風(fēng)機、風(fēng)扇電容器。高壓保護故障:解決方法,雪種過多,高壓保護器損壞、信號線斷或室內(nèi)機控制板損壞。E1 is a system-voltage protecti on. Fault Prin ciple: brass conn ecti ons outside themach ine has a high voltage protect ion switch, th

5、rough the high pressure switchdetects the system pressure, then back to the chip via lines.Maintenance procedures:1. First rule out external factors, such as evaporators, condensers dirty, lack of equal power. If the machine displays a boot on E1, to see if the compressor is started, if not start me

6、asuring high voltage switch, if the measured start the compressorstartingcurrent.2. Machine open for sometime to displayE1, check the high voltageswitch,and line.High-voltageswitchcan be shorted or OVCshorted somewhere excludefailures.E1: high-voltageprotectionfor thecompressor. 1, thereisan obstacl

7、ebefore thecondenser 2, when the outdoor temperature is higher than 43 degrees start cooling3, the control circuit anomaly 4, the high-pressure pipe pressure Ambassador high voltage switchingThen we can analyze the fault codes mean, generally faulty parts of this failureare: bad outdoor unit heat, c

8、an be cleaned. Slow outdoor fan does not turn or turn: decision solution method, for the fan, the fan capacitor. High pressure protection fault: Solution, refrigerant excessive, high-voltage protection is damaged, the signal line is broken or damaged indoor control board.E2:室內(nèi)機蒸發(fā)器防凍結(jié)保護??赡茉颍汗收洗a E2:

9、第一步先判斷是控制故障還是系統(tǒng)故障,可先把室內(nèi)管溫包從蒸 發(fā)器中取出,如果不出現(xiàn),則說明是系統(tǒng)問題;第二步檢查室內(nèi)環(huán)境溫度是否太低,室內(nèi)風(fēng) 機轉(zhuǎn)速是否太低,室內(nèi)蒸發(fā)器是否太臟,系統(tǒng)是否堵塞。5.開機顯示故障代碼 E2:室內(nèi)管溫器斷路,造成誤保護。 6. 運行一段時間壓縮機、室外風(fēng)機停止,室內(nèi)風(fēng)機仍運轉(zhuǎn),顯示 故障代碼E2(燈箱型無顯示):(1)檢查蒸發(fā)器是否結(jié)霜,若結(jié)霜,則顯示故障代碼E2。其結(jié)霜原因可能是:1) 系統(tǒng)缺氟, 可用壓力表測系統(tǒng)壓力、 用鉗表測運行電流, 低壓偏低或電流偏小,則需加氟。2)氣溫偏低(25C以下)時,制冷運行蒸發(fā)器可能會結(jié)霜。3)蒸發(fā)器表面臟,風(fēng)量小。(2 )如蒸發(fā)

10、器未結(jié)霜,則可能是室內(nèi)管溫頭位置不對,造成局部溫度過低,可將管溫頭移出再試。(3)室內(nèi)管溫感溫包壞或折斷。(4)也可能是顯示器本身故障或控制板問題。(5)過濾網(wǎng)太臟。(6)系統(tǒng)臟堵。(7 )室內(nèi)電動機轉(zhuǎn)速太低。E2: in door evaporator an ti-freeze protecti on.Possible causes: Error code E2: the first step is to determine fault or controlsystemfailure, the in door pipe temperature can first be removed fro

11、m the evaporator package, if you do not appear, the problem is the system; the second step is to check the ambie nt room temperature too low, the in door fan speed is too low, the in door evaporator is dirty, the system is blocked. 5. Power error code E2: in door pipe temperature control circuit,cau

12、sing malfunctionprotection.6. Run a period of timeof the compressor, outdoor fan stops, in door fan is still running, error code E2 (light boxes without display) :( 1) Check whether the evaporator frost, if frost, the error code E2. Its frost reason may be: 1) lack of fluoride system, availablegauge

13、 pressuremeasurement system, measured with a clamp operatingcurrent,low-voltage low or current is too small, you need fluoride.2) low temperature (25 Cor less), the cooling operation may evaporator frost. 3) evaporator surface is dirty, the small amount of wind. (2) If the evaporator is not frost in

14、g, it may be the in door pipe temperature head positionis wrong, resulting in local temperature is too low,you can head out of the tube temperature and try aga in. (3) In door pipe temperature, temperature of bad or broke n. (4) may also be a display fault or the board itself issues. (5) The filter

15、is dirty. (6) The system fouli ng. (7) In door motor speed is too low.制冷過負(fù)荷保護,即內(nèi)機蒸發(fā)器結(jié)冰了, 原因:1老鼠把傳感器線咬斷可能性在百分之六十 以上,特別是飯店等公共場所。2內(nèi)機濾網(wǎng)臟堵,可能性一半以上。 3 內(nèi)風(fēng)機電容量減小導(dǎo)致內(nèi)風(fēng)機轉(zhuǎn)速低。4內(nèi)機蒸發(fā)器后背太臟,導(dǎo)致蒸發(fā)器不通風(fēng)。5傳感器阻值漂移Cooli ng overload protect ion, n amely the mach ine evaporator freeze up because: 1mouse sensor wires snapped

16、the possibility of more than sixty percent,particularlyin restaura nts and other public places. 2 mach ine filter fouli ng, more tha n half of the possibility. 3 in the electrical and mechanical wind capacity is reduced result ing in lower internal fan speed. 4 mach ine evaporator back dirty, result

17、 ing in non-ven tilated evaporator. 5 sen sor resista nee driftE3為壓縮機吸氣壓力過低保護,建議檢查:1.室內(nèi)機循環(huán)風(fēng)量過小清潔室內(nèi)機濾網(wǎng)。2.系統(tǒng)制冷劑不足添加制冷劑。E3 for the compressor suct ion pressure is too low, we recomme nd that exam in ati on:1. in door circulati ng air volume is too small Clea n in doorunit filters. 2.In sufficie nt refr

18、igera nt system Add refrigera nt.E4保護:為排氣管高溫保護。 壓縮機起動后,連續(xù)30s檢測到排氣溫度高于120 C或排氣感 溫頭短路(或開路)時,指示燈閃爍并顯示故障代碼E4。E4 protectio n:an exhaust pipe temperature protect ion.After the compressor starts,con ti nu ous30s detectsa temperature highertha n120C exhaust or exhausttemperaturesensor shortcircuit (or open)

19、, thelightbli nksand the fault code E4.格力空調(diào)故障代碼 E5:低電壓過流保護可能出現(xiàn)的原因有以下:1 、電源電壓低于187V,現(xiàn)在的空調(diào)都是寬電源設(shè)計,但是如果低于這個數(shù)字,空調(diào)也是不能啟動的!2、內(nèi)機過濾網(wǎng)和外機的 冷凝器太臟引起的保護,建議先清洗一下。3、控制板故障,更換控制板先檢查一下電壓是否正常,如果不穩(wěn)定的話,建議安裝穩(wěn)壓器,如果電壓沒有問題的話,就聯(lián)系廠家的專業(yè)人員上門檢修吧!Gree air-conditioningfault code E5: Lowvoltage over-current protectionThe followi ng

20、 are possible reas ons:1, the supply voltage drops below 187V, the air conditioningis now wide powersupply design, but if less than this figure, air conditioning is not activated!2, the machine filters and outside the machine dirty condenser protection cause, it is recommended to wash.3, the control

21、 board failure, replace the control boardFirst check the voltage is normal, if unstable, it is recommended toinstall regulator, if the voltage is not a problem, just contact the manufacturers of professional home repair it!一、格力空調(diào)三種機型顯示 E5 的含意1、格力定頻空調(diào)顯示 E5 代表低電壓保護(過電流保護)!2、格力變頻空調(diào)顯示e5代碼為室內(nèi)外通訊故障3、格力分體立

22、柜式空調(diào)顯示e5為一一低電壓保護,堵轉(zhuǎn)過流保護 二、格力定頻空調(diào)顯示E5的維修方法1、查看電壓是否過低,可建議用戶安裝穩(wěn)壓器2、外機電容是否損壞3、外機散熱是否良好,內(nèi)機過濾網(wǎng)和外機的冷凝器是否太臟4、控制板故障,更換控制板 三、E5故障的系統(tǒng)診斷1、壓縮機運轉(zhuǎn)后,連續(xù) 3 秒鐘檢測到 電流超過 6A2、指示燈閃爍并顯示 E5。First, Gree air-conditioning three models show the meaning E51, Gree fixed-frequency air show E5 Representative - Low-voltage protectio

23、n (overcurrent protection)!2, Gree inverter air conditioner displays e5 code - as indoor and outdoor communication failure3, Gree air-conditioning closet split display e5 is - low voltage protection,overcurrent stallSecond, Gree air-conditioning fixed-frequency display of maintenance methods E51. Ch

24、eck the voltage is too low, can recommend that users install the regulator2, outside MOTORS damage3, outside the machine cooling is good, the machine filters and the outdoor unitcondenser is dirty.4, control board failure, replace the control boardThird, the system fault diagnosis E51, the operation

25、 of the compressor for 3 seconds detected current exceeds 6A2, the light blinks and E5.2. 顯示H6,是電機堵轉(zhuǎn)或電機不轉(zhuǎn)動故障。3. 代表你的內(nèi)機太臟了。 關(guān)掉主電源, 打開下蓋, 抽出過濾網(wǎng)清洗; 用毛刷清潔那個靜電除塵器。4.4. 格力空調(diào)故障代碼E6的解決辦法:5. 1. 接線圖外機電源蓋上應(yīng)該有的, 如果按照圖上所示接還是有問 題的話你你注意觀察一下接線座上面的線, 我遇到過別的品牌空調(diào)出廠 時座上面的線接錯的,就是說假如2上面按圖所示是N線但它接錯了結(jié) 果上面連接到了信號線上, 你按圖接后就會出

26、現(xiàn)不工作或工作不正常的 現(xiàn)象,好好看看想想。6. 2. 死機: 把電打下來幾秒再打回去,開機試一下。7. 3. 內(nèi)外機信號線斷或漏電,更換室內(nèi)外連接信號電線再試機。8. 4. 電路板壞,更換室內(nèi)機電路主板。10.9. 格力空調(diào)顯示E6的檢修流程:10. 開關(guān)電源正常 5V 電壓正常嗎正常查通信光耦外機 接線端檢修室內(nèi)外信號線 N 以通信線有跳變電壓嗎沒有查 內(nèi)機有查外機晶振也查一下更換電路主板。13.2. Display H6, a motor stall fault or motor does not rotate.14. represent your machine dirty. Turn

27、 off the main power supply, open under cover, out of the filter cleaning; use a brush to clean the electrostatic precipitator.15.16.Gree air-conditioning fault code E6 solution:17.1. The wiring diagram should cover some of the power out of the machine, if connected as shown in the figure is still a

28、problem, then you look at your attention to terminal blocks above the line, I met other brands of air conditioning factory seat upper line access wrong, that if shown in Figure 2 above, but it is wrong N line connecting the above results to the signal line, and you will appear in Figure phenomenon i

29、s not working or not working properly followed, think a good look .18.2. crashes: the power play call back down for a few seconds, turn try.19.3. inside and outside the signal line is broken or leakage, replace the indoor and outdoor connecting signal wires try machine.20. The circuit board is broke

30、 n, replace the in terior mecha ni caland electrical circuit board.21.22.Gree air-c on diti oning maintenance display E6 process:23.Switching power supply voltage normal -5V normally do - Normal check com muni cati on optocouplers - term inal outside the machi ne-in door and outdoor sig nal line -N

31、overhaul to the com muni cati on line to the jump voltage do - did not check in side the machi ne-there are check outside the machi ne - Crystal also check -replace the circuit board.24. E7模式?jīng)_突 在多聯(lián)機上 常見 可能不同的內(nèi)機開的模式不一樣有的是制冷 有的是制熱建議看下說明書25. E7 commormodeof conflict on several different online mayopen

32、the machine model is not the sameas some heating and cooling some recomme ndati ons facie manual26. E8控制面板和主控板之間通訊故障查查是不是線被老鼠咬了!或者插線排接觸不良!E8 betwee n the control panel and the controlboard com muni cati on line failure look is not bitte n by rats! OrPlug row is bad!27. 格力空調(diào)故障代碼e8的有效解決方法:28. 故障機型:KFR

33、-71LW29. 故障現(xiàn)象:開機能制冷,10分鐘左右室內(nèi)外機均停止工作,室內(nèi)機面板顯示E8的錯誤代碼。30. 故障分析:經(jīng)珠海格力空調(diào)維修師傅上門對機器進行檢修,格力空調(diào)維修師傅根據(jù)格力空調(diào)故障代碼表得知e8代碼的含義是:壓縮機排氣溫度傳感器1故障。順著這個方向查下去很快便查到了故障所在位置。首先檢查壓縮機排氣溫度傳感器阻值是否正常,經(jīng)檢查沒問題。再檢查雪種壓力是否過高,經(jīng)證明雪種也 正常。開機觀察室外岀風(fēng)量也夠大,開機數(shù)分鐘后發(fā)現(xiàn)室外機散岀來的風(fēng)越來越熱,此時看到冷凝器翅片 上布滿了灰塵,說明此機沒有清洗保養(yǎng)過,故障原因就在這里。31. 解決方法:用專用的空調(diào)翅片清洗劑加入水于3比1比率對翅片進行清洗后開機試機運行正常,不再出現(xiàn)e8代碼,故障排除了。32. Gree air-c on diti oning fault code e8 effective soluti on:33. Fault models: KFR-71LW34.Symptom: boot can Refrigerati on, about 10 minu tes of in

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論