1、下面是查看HP小型機(jī)的信息的命令集:1、機(jī)型#model9000/800/L2000-44注意:其中44是指每個cpu有440MHZ。2、cpu個數(shù)#topCPU LOAD USER NICE SYS IDLE BLOCK SWAIT INTR SSYS0 0.02 0.0% 0.0%
2、0.% 0.0% 0.0% 0.0% 0.0%1 0.00 0.6% 0.0% 0.% 0.0% 0.0% 0.0% 0.0%2 0.00 2.% 97.0% 0.0% 0.0%
3、 0.0% 0.0%3 0.00 0.4% 0.0% 0.0% 99.6% 0.0% 0.0% 0.0% 0.0%3、硬盤的大小信息#diskinfo /dev/rdsk/c1t0d0SCSI describe of c1t0d0: vendo
4、r: SEAGATE product id: ST39204LC type: direct access size: 8891556 Kbytes bytes per sector: 5124、硬盤的個數(shù)#ioscan -funC diskdi
5、sk 0 0/0/1/1 sdisk CLAIMED DEVICE SEAGATE ST39204LC /dev/dsk/c1t0d0 /dev/rdsk/c1t0d0dis
6、k 1 0/0/1/1.2.0 sdisk CLAIMED DEVICE SEAGATE ST39204LC /dev/dsk/c1t2d0 /dev/rdsk/c1t2d0
7、disk 2 0/0/2/0.0.0 sdisk CLAIMED DEVICE SEAGATE ST39204LC /dev/dsk/c2t0d0 /dev/rdsk/c2t
8、0d0disk 3 0/0/2/0.2.0 sdisk CLAIMED DEVICE SEAGATE ST39204LC /dev/dsk/c2t2d0 /dev/rdsk/
9、c2t2d0disk 4 0/0/2/1.2.0 sdisk CLAIMED DEVICE HP DVD-ROM 305 /dev/dsk/c3t2
10、d0 /dev/rdsk/c3t2d0disk 5 0/4/0/0.8.0 sdisk CLAIMED DEVICE SEAGATE ST39236LC /dev/dsk/c
11、4t8d0 /dev/rdsk/c4t8d05、查看操作系統(tǒng)版本和license#uname -aHP-UX scp1 B.11.00 U 9000/800 1124961527 unlimited-user license6、如何查看內(nèi)存#dmesg Memory Information: physical page size = 4096 bytes, logical page size = 4096 bytes Physical: 2097152 Kbytes, lockable: 1866308 Kbytes,
12、 available: 1902728 Kbyts7、如何查看文件系統(tǒng)#bdfFilesystem kbytes used avail %used Mounted on/dev/vg00/lvol3 1025617 24790 898265 3% /dev/vg00/lvol1 700691 3548
13、2 595139 6% /stand/dev/vg00/lvol8 2097152 436927 1557195 22% /var/dev/vg00/lvol7 1048576 481524 531631 48% /usr/dev/vg00/lvol6 255253 148
14、160;229579 0% /tmp/dev/vg01/lv_tellin 2051553 127152 1719245 7% /tellin/dev/vg00/lvol5 2097152 81783 1889462 4% /opt/dev/vg01/lv_informix
15、60; 2051553 413823 1432574 22% /opt/informix/dev/vg00/lvol4 524288 1229 490375 0% /home存在兩個文件中:/etc/fstab /etc/mnttab8、查看卷組、卷組所包括的邏輯卷、以及該卷組
16、所包括的物理磁盤#vgdisplay -v vg00則結(jié)果都是按照邏輯卷組、邏輯卷、物理磁盤的順序全部顯示。9、查看卷組、邏輯卷的位置#cd /dev/在該目錄下面有所有的邏輯卷組,再進(jìn)入某個邏輯卷組,則看到它所有的所有邏輯卷了。10、激活/去激活卷組#vgchange -a y 卷組名 (激活)#vgchange -a n 卷組名 (去激活)11、創(chuàng)建卷組、邏輯卷、文件系統(tǒng)的一系列命令格式化#pvcreate /dev/rdsk/c0t1d0 (這里假設(shè)有塊盤的設(shè)備文件名是c0t1d0) 創(chuàng)建卷組名#mkdir /dev/v
17、glock創(chuàng)建卷組的設(shè)備文件名字#mknod /dev/vglock/group c 64 0x010000 (這里注意group不能重復(fù))創(chuàng)建卷組#vgcreate /dev/vglock /dev/dsk/c0t1d0 (將物理磁盤c0t1d0加給該卷組)激活卷組#vgchange -a y /dev/vglock創(chuàng)建邏輯卷lv_informix#lvcreate -n lv_informix /dev/vglock 給邏輯卷增加大小#lvextend -l 50 /dev/vglock/lv_info
18、rmix (單位是頁,頁的大小再創(chuàng)建卷組時已經(jīng)確定,不可以再更改,一般缺省為4M,所以是200M)或者#lvextend -L 200 /dev/vglock/lv_informix (這是帶大寫的L參數(shù),表示是以M為單位來分配的大小的。)如果還要將該卷組變?yōu)槲募到y(tǒng)的話,那么如下創(chuàng)建文件系統(tǒng)#newfs -F hfs /dev/vglock/rlv_informix創(chuàng)建文件系統(tǒng)掛接的目錄#mkdir /informix將文件系統(tǒng)掛接上去#mount /dev/vglock/lv_informix /informix12、刪除卷組、邏輯卷刪除邏輯卷
19、#lvremove /dev/vglock/lv_informix去激活卷組#vgchange -a /dev/vglock (如果不能夠去激活,則可以用如下命令強(qiáng)行去激活,vgchange -c n /dev/vglock)預(yù)刪除卷組#vgexport -p -s -m /tmp/vglock.map /dev/vglock刪除卷組#vgexport -s -m /tmp/vglock.map /dev/vglock13、創(chuàng)建共享卷組在的一臺已經(jīng)創(chuàng)建卷組的機(jī)器上先去激活#vgchange -a n /dev/vglock預(yù)刪除卷組#vgexport
20、 -p -s -m /tmp/vglock.map /dev/vglock將map文件傳送到另外一臺機(jī)器#rcp scp1:/tmp/vglock.map scp2:/tmp/vglock.map在另外一臺機(jī)器上導(dǎo)入卷組之前要先創(chuàng)建卷組名#mkdir /dev/vglock創(chuàng)建group節(jié)點(diǎn)文件#mkno /dev/vglock/group c 64 0x010000 (該節(jié)點(diǎn)一定要和第一臺機(jī)器一致)導(dǎo)入卷組#vgimport -s -m /tmp/vglock.map /dev/vglock14、informix的版本的收集#su - informixinformix&
21、gt;onstat -這樣可以看到informix的版本。15、雙機(jī)維護(hù)命令在一臺運(yùn)行以下命令先將兩個節(jié)點(diǎn)的cluster守護(hù)進(jìn)程都拉起來,然后還會自動的將應(yīng)用也拉起來。cmruncl;或者先在主機(jī)上運(yùn)行雙機(jī)的守護(hù)進(jìn)程,再將備機(jī)節(jié)點(diǎn)加入,然后再來將應(yīng)用制定在某個節(jié)點(diǎn)上運(yùn)行,那么指定的節(jié)點(diǎn)就應(yīng)該是主機(jī)。cmruncl -n scp1;cmrunnode scp2;cmrunpkg -n scp1 -v scp_service;查看雙機(jī)的狀態(tài)cmviewcl -v;cmviewcl ;cmquerycl;cmviewconf;雙機(jī)切換方法一:可以停止主機(jī)cmhaltnode
22、scp1方法二:可以手工切換應(yīng)用cmhaltpkg -n scp1 -v scp_service(將應(yīng)用scp_service從scp1機(jī)器上停止運(yùn)行)或者su - tellinstellin>kill_scp.sh或者su - informixinformix>onmode -kuy主機(jī)切換后的節(jié)點(diǎn)要重新變?yōu)榭梢郧袚Q的節(jié)點(diǎn),必需要運(yùn)行如下命令cmmodepkg e -n scp1 -v scp_service (應(yīng)用scp_service可以下次再切回scp1節(jié)點(diǎn))有時候為了診斷備機(jī),特將備機(jī)設(shè)置為不可以運(yùn)行應(yīng)用的節(jié)點(diǎn),如cmmod
23、epkg d -n scp1 -v scp_service (節(jié)點(diǎn)scp1上是不可以運(yùn)行應(yīng)用scp_service)16、雙機(jī)的配置文件的位置#cd /etc/cmcluster/ (雙機(jī)守護(hù)進(jìn)程的配置文件cmcluster.asc)#cd /etc/cmcluster/scppkg/ (雙機(jī)的應(yīng)用配置文件scppkg.asc,control.sh,scppkg.sh,這三個文件中有一個文件是用來制定雙機(jī)的浮動IP的)17、雙機(jī)維護(hù)命令的位置#cd /usr/sbin/ (用ls cm*可以看到所有關(guān)于
24、雙機(jī)的執(zhí)行命令)18、雙機(jī)的配置配置cmcluster.asc;檢查cmcluster.asc配置文件的有效性#cmcheckconf -v -C cmcluster.asc如果配置不對,則會有錯誤提示,根據(jù)錯誤提示再來更正,直到正確后才來應(yīng)用該配置文件#cmapplyconf -f -v -C cmcluster.asc如果覺得應(yīng)用后配置要重新更改,可以將配置文件刪除#cmdeleteconf -v -c scp1#cmdeleteconf -v -c scp2配置應(yīng)用文件scppkg.asc,control.sh,scppkg.sh檢查三個文件的有效性#cmcheck
25、conf -v -P scppkg.asc如果配置不對,則會有錯誤提示,根據(jù)錯誤提示再來更正,直到正確后才來應(yīng)用該配置文件#cmapplyconf -f -v -C scppkg.asc如果覺得應(yīng)用后配置要重新更改,可以將配置文件刪除#cmdeleteconf -v -c scp1#cmdeleteconf -v -c scp2 備注:這里所指的刪除是在需要單機(jī)診斷雙機(jī)的時候才會用到,否則不需要這么負(fù)責(zé),只需要重新應(yīng)用一下就可以了,原來的刪不刪除無所謂。18、網(wǎng)絡(luò)的配置首先網(wǎng)線一定要連接正確在給小型機(jī)配置網(wǎng)卡的時候一定要先確保網(wǎng)卡的驅(qū)動程序已經(jīng)安裝了,用以下的命令查看.
26、#lanscan 如果看到的主用網(wǎng)卡和附加的網(wǎng)卡的狀態(tài)都是up狀態(tài),則表示網(wǎng)卡都可用了。而且此時一定要知道那塊卡用來做數(shù)據(jù)網(wǎng)卡,這塊網(wǎng)卡應(yīng)該是在安裝HP-UX操作系統(tǒng)的時候就已經(jīng)確定了,比如選擇lan0來做主用數(shù)據(jù)網(wǎng)卡,并且該塊網(wǎng)卡的地址一般在安裝HP-UX的時候也已經(jīng)顯示了它的設(shè)備路徑如:0/1/10/0 等,或者用lanscan命令也可以看到它的路徑,指導(dǎo)后就應(yīng)該將直連網(wǎng)線從該網(wǎng)扣連接到主用HUB上去。然后另外兩塊是備用網(wǎng)卡,也可以根據(jù)設(shè)備的路徑來確定他們兩個的位置,確定以后就可以將其中一塊卡用交叉網(wǎng)線與另外一臺機(jī)器的同樣的網(wǎng)口相連,用來做心跳線。那么另外的一個附加網(wǎng)卡就不要配置地址了,我
27、們是用它來作為備用網(wǎng)卡使用的,要用直連網(wǎng)線從該口連接到備用HUB上,它既可以作為心跳網(wǎng)卡的備用網(wǎng)卡,也可以作為數(shù)據(jù)網(wǎng)卡的備用網(wǎng)卡。在HPL2000系列的機(jī)器上我們還可以看到在數(shù)據(jù)網(wǎng)卡的上面有一個網(wǎng)扣,該口是作為console口使用的,用一根console線可以與它相連接進(jìn)行配置機(jī)器。再來配置IP地址#vi /etc/rc.config.d/netconf該文件下面有所有的網(wǎng)卡的名字、網(wǎng)卡的iP地址、網(wǎng)關(guān)、子網(wǎng)掩碼的配置這樣配置以后可以長期生效,下次機(jī)器重新啟動的時候就會根據(jù)該配置文件來自動配置網(wǎng)絡(luò)了?;蛘?ifconfig lan0 133.64.4
28、8.91 92#ifconfig lan1 20 92查看網(wǎng)卡的地址#lanscan lan0#lanscan lan1lan2不配置地址。網(wǎng)卡的常用診斷工具ping;lanscan;看看網(wǎng)卡地狀態(tài)是否為“up”linkloop;(用此命令的時候,一定要先用lanscan來查處網(wǎng)卡的物理地址,因為該命令的后面接的參數(shù)是網(wǎng)卡物理地址,這可以簡單地斷定網(wǎng)線、集線器是否有問題)在同一網(wǎng)中, subnetmask 應(yīng)一致。19、在配置雙機(jī)的cmcluster.asc的時候要制定該網(wǎng)卡的
29、IP地址所在的子網(wǎng),則可以通過以下來查看#netstat -in (可以看到網(wǎng)卡的地址、IP地址對應(yīng)的子網(wǎng)、網(wǎng)關(guān)、缺省路由、是否有浮動網(wǎng)卡、是否主機(jī))20、配置路由信息方法一:可以通過修改/etc/rc.confg.d/netconf文件來增加,下次啟動的時候就會生效。方法二:可以用命令行來設(shè)置:/usr/sbin/route add default 20.08.28.98 121、查看路由信息#netstat -an22、配置遠(yuǎn)程維護(hù)如何確定是否已經(jīng)配置了遠(yuǎn)程維護(hù),遠(yuǎn)程維護(hù)是通
30、過硬件來配置的,只要遠(yuǎn)程維護(hù)的串口沒有損壞,哪怕你是重新安裝,在小型機(jī)前面板上的remote燈會亮為黃色,黃色的燈一直都是兩著的表示可以遠(yuǎn)程維護(hù)串口正常。但是我們還是需要通過GSP來配置遠(yuǎn)程維護(hù)。小型機(jī)的remote口的配置ctrl + benterenterGSP> ca這樣就出現(xiàn)了對話框,如果你要修改某個參數(shù)的話,可以通過該對話框來修改。通常的值是:bitrate :9600flow control :softwareterminal type:vt100modem protocol:CCITTmodem bit rate:9600flow control :hardwaremode
31、 transmit configuration:disablemode presence:always connectedmodem上的配置AT&FATS0=1AT&WO&Y0保存退出。備注:HP公司一般提供了專門的全向modem,名字叫“天幕馳舟”,modem一定要接在line口上。23.一個超級命令#set_parms它后面帶的參數(shù)可以是如下date_time:設(shè)者時間;ip_address:設(shè)置網(wǎng)卡地址;hostname:設(shè)置主機(jī)名;addl_netwrk:設(shè)置主機(jī)的網(wǎng)關(guān)。24、用戶和用戶組的添加方法一:用useradd和groupadd命令來添加;方法二:修改文
32、件/etc/passwd 和 /etc/group 文件來實現(xiàn)。25、一個有用的工具是sam通過sam可以進(jìn)行各種操作,比如:用戶、用戶組的管理;邏輯卷組、邏輯卷的管理;內(nèi)核參數(shù)的管理;26、一個有用的診斷工具mstm用它可以收集到所有的硬件信息,比如一共有哪些內(nèi)存插口,每塊現(xiàn)有的內(nèi)存條有多大,還可以查幾個內(nèi)存條等等信息。使用舉例:#mstm選擇system(),并且在菜單上選中Tools/information/information log便可以看到很多關(guān)于硬件的消息,如:System Information for (scp1) HPUX Model Number
33、.: L2000 /機(jī)器型號是HP L2000 HPUX Model String.: 9000/800/L2000-44 Original Product Number: A5191A Current Product Number.: System Serial Number.: (Unknown)
34、 Hversion.: 0x5c40 Sversion.: 0x491 Software Capabilities.: 0x100000f0PD CPU Information: Number of CPUs in the current Protection Domain = 2 /兩個cpuCabinet 0; Cell 0; CPU Mapcpu -slot |00|01|02|03|04|05|06|07|08|09|10
35、|11|12|13|14|15| -state| a| | | | | | | | | | | | | | | | - c -
36、 Configured (CPU powered on) d - De-configured (CPU powered off) a - Active
37、60; (configured and processes running)選擇memory,并且在菜單上選中Tools/information/information log便可以看到關(guān)于內(nèi)存的信息,如:- Information Tool Log for MEMORY on path 8 -Log creation time: Wed Jul 3 17:05:47 2002Hardware path: 8Basic Memory Description
38、 Module Type: MEMORY Total Configured Memory : 1024 MB /可以看到總的內(nèi)存有多少,是1G Page Size: 4096 Bytes Memory interleaving is supported on this machine and is ON.Memory Board Inventory DIMM Slot Size (MB
39、) - - 0a 256 /可以看到每個內(nèi)存槽里面是不是已經(jīng)插了內(nèi)存條,還有 &
40、#160; 該內(nèi)存條是多少的內(nèi)存,比如這里0a槽上插的是256M 1a 256 0b 256
41、160; 1b 256 - - /可以看出該臺小型機(jī)的4個內(nèi)存槽都已經(jīng)插滿了 System Total (MB): 1024
42、0; Memory Error Log Summary The memory error log is empty.Page Deallocation Table (PDT) PDT Entries Used: 0 PDT Entries Free: 50 PDT Total Size: 50在使用mstm的時候可以打開另外一個終端窗口,執(zhí)行命令#/usr/sbin/ioscan -fn ,這樣可以知道每個設(shè)備的硬件地址信息。這樣可以得到如下結(jié)果:lan&
43、#160; 2 0/7/0/0 btlan6 CLAIMED INTERFACE HP A3738A PCI 10/100Base-TX Ultimate Combo /dev/diag/lan
44、2 /dev/ether2 /dev/lan2memory 0 8 memory CLAIMED MEMORY Memoryprocessor 0 160
45、160; processor CLAIMED PROCESSOR Processorprocessor 1 166 processor CLAIMED PROCESSOR Processor這樣可以知道0/7/0/0地址對應(yīng)的是一個100M的網(wǎng)卡,然后再到mstm窗口中去查看它的info
46、rmation log信息,這樣可以很清楚硬件信息了。該收集結(jié)果文件中還可以找到磁盤的使用信息,如: I H/W Path Driver S/W State Description = 0 0/0/1/1.2.0 sdisk CLAIMED
47、; SEAGATE ST39204LC 1 0/0/2/1.2.0 sdisk CLAIMED HP DVD-ROM 304 2 0/3/0/0.0.0 sdisk CLAIMED HP C54
48、47A 4 0/3/0/0.0.1 sdisk CLAIMED HP C5447A 6 0/3/0/0.0.2 sdisk CLAIMED HP C5447A 8
49、60; 0/3/0/0.0.3 sdisk CLAIMED HP C5447A 10 0/3/0/0.0.4 sdisk CLAIMED HP C5447A 12 0/3/0/0.0.5 sdisk
50、160; CLAIMED HP C5447A 3 0/6/0/0.1.0 sdisk CLAIMED HP C5447A 5 0/6/0/0.1.1 sdisk CLAIMED
51、 HP C5447A 7 0/6/0/0.1.2 sdisk CLAIMED HP C5447A 9 0/6/0/0.1.3 sdisk CLAIMED HP C5447A
52、0; 11 0/6/0/0.1.4 sdisk CLAIMED HP C5447A 13 0/6/0/0.1.5 sdisk CLAIMED HP C5447A Device H/W Path
53、0;Product id Size Physical Alternate (Mbytes) Volume
54、; Link = c1t2d0 0/0/1/1.2.0 ST39204LC 8683 yes bootable no c3t2d0 0/0/2/1.2.0 DVD-ROM
55、60; 0 no n/a c4t0d0 0/3/0/0.0.0 C5447A 1024 yes no
56、 c4t0d1 0/3/0/0.0.1 C5447A 2052 yes no c4t0d2 0/3/0/0.0.2 C5447A 10252
57、160; yes no c4t0d3 0/3/0/0.0.3 C5447A 1024 no n/a c4t0d4 0
58、/3/0/0.0.4 C5447A 2052 no n/a c4t0d5 0/3/0/0.0.5 C5447A 10252 no
59、 n/a c5t1d0 0/6/0/0.1.0 C5447A 1024 yes yes c5t1d1 0/6/0/0.1.1 C5447A
60、0; 2052 yes yes c5t1d2 0/6/0/0.1.2 C5447A 10252 yes yes
61、60; c5t1d3 0/6/0/0.1.3 C5447A 1024 no n/a c5t1d4 0/6/0/0.1.4 C5447A 2052
62、 no n/a c5t1d5 0/6/0/0.1.5 C5447A 10252 no n/a Note: All disk devices ar
63、e listed here, not only hard disks.LVM mirroring software* LVM mirroring software MirrorDisk/UX (B2491A) is NOT installed.*Part 2: VOLUME GROUPS*Volume Group: /dev/vg00* Physical Volumes: /dev/dsk/c1t2d0 Volume group disk space usage:
64、 Total : 8676 Mbytes 2169 PE Allocated: 8404 Mbytes 2101 PE Free : 272 Mbytes 68 PE PE size : 4 MbytesVol
65、ume Group: /dev/vg10* Physical Volumes: /dev/dsk/c4t0d0 /dev/dsk/c5t1d0 Alternate Link Volume group disk space usage: Total : 1020 Mbytes 255 PE Allocated:
66、160; 0 Mbytes 0 PE Free : 1020 Mbytes 255 PE PE size : 4 MbytesVolume Group: /dev/vg12* Physical Volumes: /dev/dsk/c4t0d2
67、;/dev/dsk/c5t1d2 Alternate Link Volume group disk space usage: Total : 10248 Mbytes 2562 PE Allocated: 10076 Mbytes 2519 PE Free : 172 Mbytes
68、0; 43 PE PE size : 4 Mbytes備注:其實用該收集工具就是在shell中執(zhí)行不通的程序得到,如執(zhí)行:ioscan -fn;mstm;cstm;sam;等等。27、重新啟動機(jī)器#reboot #shutdown 28、關(guān)閉機(jī)器#shutdown -hy 0#init 028、unix的集中運(yùn)行的模式多用戶模式,但用戶模式等等6種。用如下命令可以看看它的運(yùn)行模式:#who -r29、普通的對話#wall "hello!"
69、;(廣播hello這個消息)#banner "hello!"(放大hello這個消息)#banner "hello!"|more (放大hello消息后再來廣播它)30、看當(dāng)前的登錄名#logname31、看所有登錄用戶#whoiam32、看登錄用戶在干什么#whodo33、看看進(jìn)程ps -ef|grep root (看root用戶的進(jìn)程,有時候console上執(zhí)行的進(jìn)程不能夠停止的話,那么就將console進(jìn)程進(jìn)程殺死,因為該進(jìn)程是其它進(jìn)程的父進(jìn)程。)34、webconsole的設(shè)置HP Secure Web Console 的配
70、置與維護(hù) HP 的Secure Web Console 為系統(tǒng)管理員提供了一個基于Web的、更為 方便的接入Console的手段。系統(tǒng)管理員只需在任意一臺能夠ping通Web Console的PC上,啟動網(wǎng)絡(luò)瀏覽器,輸入Web Console的IP,即可得到服務(wù)器Console的界面。配置Web Console,應(yīng)按以下步驟:1)初始化Web Console:1/將Web Console接入局網(wǎng)。其預(yù)設(shè)置的IP地址為92。2/在您的PC上,運(yùn)行以下命令: route add 92
71、Local_IP_address3/確保能夠ping 92。4/在PC上運(yùn)行網(wǎng)絡(luò)瀏覽器,輸入URL:92,得到Web Console配置菜單。按菜單提示輸入Admin Account 用戶名和密碼,將其IP改為本局網(wǎng)IP地址(確保IP不要重復(fù))和子網(wǎng)掩碼。2)使用 Web Console1/用普通Console的串口線,一端接服務(wù)器Local Console口,另一端接 Web Console 的串行口。2/在PC的瀏覽器上,輸入 Web Console當(dāng)前的IP地址。即進(jìn)入其LOGIN窗口,按要 求輸入在配置時創(chuàng)立的Admin Account用
72、戶名和密碼;則進(jìn)入服務(wù)器Console界面, 用鼠標(biāo)點(diǎn)擊Access Console,黑色的Console窗口出現(xiàn)在屏幕右方;點(diǎn)擊In/Out可放 大Console窗口。35、demo進(jìn)程的位置/etc/rc3.d/中的文件在系統(tǒng)啟動的時候便可以將進(jìn)程拉起來。36、磁帶的使用寫:tar cvf /dev/rmt/0m0m中;讀:tar tvf /dev/rmt/0m /讀出磁帶0m中的內(nèi)容;從磁帶上解開tar文件:tar xvf /dev/rmt/0m/aa.tar ./ /將磁帶上的aa.tar文件解開到當(dāng)前目錄下;當(dāng)用
73、磁帶來啟動機(jī)器的時候,我們在啟動的時候敲擊任意鍵,就可以進(jìn)入啟動的路徑,再輸入SEA(search)來搜尋啟動的路徑,然后就可以找到磁帶的路徑,如磁帶路徑為5號路徑,則輸入po 5,便可以從磁帶啟動了。37、HP-UX的安裝=HPUX雙機(jī)系統(tǒng)的安裝1)在兩臺主機(jī)上分別安裝好HP-UX操作系統(tǒng),注意:在兩臺上的關(guān)于/,/stand,/var,/home,/usr,/opt,/swap,/dev等等文件系統(tǒng)的大小必須保持一致;2)安裝patch(以下的操作在兩臺主機(jī)上是一樣的操作)#mkdir cdrom
74、60; /創(chuàng)建一個DVD要掛接的目錄#ioscan -kfnCdisk /查看DVD的硬件描述文件,以便下面安裝前的掛接_使用標(biāo)識為support plus的光盤_a)選擇軟件包中的標(biāo)識為support plus的光盤插入DVD光驅(qū)中#mount /dev/dsk/
75、c3t2d0 /cdrom /將DVD文件系統(tǒng)掛接到/cdrom目錄下#cd /cdrom#ls /瀏覽光盤,發(fā)現(xiàn)有XSWHWCR1100和
76、0; XSWGR1100兩個patch目錄#swinstall -s /cdrom/XSWHWCR1100 /這樣就進(jìn)入了sam中進(jìn)行安裝
77、,選擇光盤 上的XSWHWCR1100,并且用sam中的菜 &
78、#160; 單項Action下的子菜單Install來進(jìn)行安裝備注:安裝完XSWHWCR1100這個patch之后,機(jī)器會自動reboot來重新創(chuàng)建新的內(nèi)核b)待機(jī)器再次啟動之后,我們就可以安裝同樣的support plus這張光盤中的另外一個名叫XSWGR1100的patch了。#mount /dev/dsk/c3t2d0 /cdrom#swinstall -s /cdrom/XSWGR1100
79、0; 備注:安裝完該patch之后同樣系統(tǒng)自動重新啟動_使用標(biāo)識為3 of 4 Application Software光盤_c)選擇軟件包中的標(biāo)識為3 of 4 Application Software的光盤插入DVD光驅(qū)中#mount /dev/dsk/c3t2d0 /cdrom#swinstall -s /cdrom
80、0; /進(jìn)入sam后選擇“Ignite -UX-11-00 B.2.5.136 HP-UX Installation Utilities
81、 for Installing 11.00 System
82、0; 97186 HP-UX-B.11.00-32/4”這個patch來安裝備注:安裝完該patch之后同樣系統(tǒng)自動重新啟動_使用標(biāo)識為4 of 4 Application Software光盤_d) 選擇軟件包中的標(biāo)識為4 of 4 Application Software的光盤插入DVD光驅(qū)中#mount /dev/dsk/c3t2d0 /cdrom#swinstall -s&
83、#160; /cdrom /進(jìn)入sam后選擇 揂.11.09 MC/ServiceGuard斦飧鰌atch來 安裝MC/ServiceGuard備注:安裝完該patch之后同
84、樣系統(tǒng)也會自動重新啟動_使用標(biāo)識為1 of 4 Application Software光盤_e)選擇軟件包中的標(biāo)識為1 of 4 Application Software的光盤插入DVD光驅(qū)中#mount /dev/dsk/c3t2d0 /cdrom#swinstall -s /cdrom /進(jìn)入sam后選擇 ?3230A B.11.00
85、;100Base-T PCI? 和 揃.11.00 HP-UX Unlimited-User License斄礁鰌atch來安裝。
86、; /其中前一個patch用于安裝附加網(wǎng)卡的驅(qū)動程序,只有安裝 &
87、#160; 了它,備用網(wǎng)卡和心跳網(wǎng)卡才在系統(tǒng)中可用,因為這兩塊 網(wǎng)卡是系統(tǒng)附加的,必須要安裝配套的驅(qū)動程序,其中
88、0; 53230A表示的是附加網(wǎng)卡的型號,這個可以從紙箱中的配 件單上獲取,系統(tǒng)本身自帶的那塊主用網(wǎng)卡是在安裝操作 系統(tǒng)的時候就已經(jīng)自動被配置了,不用我們手工再配置了。 &
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 采購合同評審表的制作步驟3篇
- 采購合同的續(xù)簽與終止條件3篇
- 采購合同框架協(xié)議的簽訂背景3篇
- 采購合同分類的詳細(xì)解讀3篇
- 2024年02月江蘇2024屆南京銀行南通分行春季校園招考筆試歷年參考題庫附帶答案詳解
- 采購合同的電子支付系統(tǒng)3篇
- 采購合同格式示例詳解3篇
- 水質(zhì)凈化微生物篩選-洞察分析
- 采購合同的供應(yīng)鏈節(jié)能減排3篇
- 采購合同補(bǔ)充協(xié)議書范例3篇
- 售后工程師述職報告
- 2023年北京大學(xué)圖書資料崗位招聘筆試真題
- 2025九年級道德與法治備考復(fù)習(xí)計劃
- 廣東能源集團(tuán)校園招聘筆試真題
- 【MOOC】高級語言程序設(shè)計-南京郵電大學(xué) 中國大學(xué)慕課MOOC答案
- 2024年企業(yè)核心管理人員勞動協(xié)議樣本版B版
- 微信公眾號信息發(fā)布流程
- 單位和個人簽的銷售合同范本(2篇)
- 商務(wù)報價技巧培訓(xùn)
- 政治學(xué)概論歷年試題(參考答案)
- 商場防恐應(yīng)急管理制度
評論
0/150
提交評論