




版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
GOVERNMENTOFTHEPEOPLE’SREPUBLICOFBANGLADESH
MINISTRYOFCOMMUNICATIONS
ROADSANDHIGHWAYSDEPARTMENT
CONSTRUCTIONOFTHIRDKARNAPHULIBRIDGE
ONTHENATIONALHIGHWAY-N1
CHITTAGONG-COX’SBAZARROADINCHITTAGONG
UNDERKFAEDASSISTANCE
TENDERDOCUMENT
VOLUME–2OF5
VOLUME-2: SECTION-V : TECHNICALSPECIFICATIONS
NOVEMBER2005
BCL-TAEP-STUPJV
BANGLADESHCONSULTANTSLTD
THEASSOCIATEDENGINEERINGPARTNERSHIP
STUPCONSULTANTSLTD
CONSTRUCTIONOFTHIRDKARNAPHULIBRIDGE
ONTHENATIONALHIGHWAY-N1
CHITTAGONG-COX’SBAZARROADINCHITTAGONG
UNDERKFAEDASSISTANCE
TENDERDOCUMENT
VOLUME–2
VOLUME-1: SECTION-1 : NOTICEINVITINGTENDER
SECTION-II : INSTRUCTIONSTOTENDERERS
SECTION-III : GENERALCONDITIONSOFCONTRACT
(PART-1:GENERALCONDITIONS)
SECTION-IV : SPECIALCONDITIONSOFCONTRACT
(PART-II:CONDITIONSOFPARTICULARAPPLICATION)
VOLUME-2: SECTION-V : TECHNICALSPECIFICATIONS
VOLUME-3: SECTION-VI : FORMSOFTENDERANDTENDERSECURITY
SECTION-VII : BILLOFQUANTITIES(BOQ)
SECTION-VIII : SCHEDULESOFFINANCIALINFORMATION
SECTION-IX : FORMOFCONTRACTAGREEMENT
SECTION-X : FORMSOFSECURITY
VOLUME-4: SECTION-XI : DRAWINGS(CONCEPTUALDESIGNOUTLINE)
VOLUME-5: SECTION-XII : SCHEDULESOFTECHNICALINFORMATION
NOVEMBER2005
BCL-TAEP-STUPJV
BANGLADESHCONSULTANTSLTD
THEASSOCIATEDENGINEERINGPARTNERSHIP
STUPCONSULTANTSLTD
SECTION-V:
TECHNICALSPECIFICATION
PART-I : DESIGNSTANDARD
PART-II : SPECIFICATIONFORCONSTRUCTION
PART-II:
SPECIFICATIONFORCONSTRUCTION
TECHNICALSPECIFICATIONS
PART-II:SPECIFICATIONFORCONSTRUCTION
DIVISION-1 : GENERALANDSITEFACILITIES
DIVISION-2 : SPECIFICATIONFORSTRUCTURES
DIVISION-3 : SPECIFICATIONFOREMBANKMENT
DIVISION-4 : SPECIFICATIONFORPAVEMENT
DIVISION-5 : SPECIFICATIONFORRIVERBANKPROTECTIONWORK
DIVISION-6 : SPECIFICATIONFORANCILLARYWORKS
DIVISION-1:GENERALANDSITEFACILITIES
TABLEOFCONTENTS
TOC\o"1-1"
1.1 PROJECTINFORMATION
1
1.2 FiElDOFFICEANDFACILITIESFORTHEENGINEER5
andTHECONSULTANTS
1.3 TRANSPORTFORTHEENGINEERANDTHECONSULTANTS 14
1.4 SITELABORATORY 16
1.5 MAINTENANCEOFTRAFFICANDDIVERSIONS 18
1.6 contractor’sGENERALobligations 20
1.0 GENERALANDSITEFACILITIES
1.1 PROJECTINFORMATION
1.1.1 ProjectLocation
ProjectCountry
Bangladeshhasatotalareaof147,570sq.kmandissurroundedtothewest,northandeastbyIndia,andsharesasouth-easternborderwithMyanmarfor283km.TothesouthistheBayofBengal.
Thetopographyischaracterizedbyalluvialplains,boundbyarangeofsub-mountainregionsandforestedhills.Thegreatrivers,theGanges(orPadma)andBrahmaputra(orJamuna)dividethecountryintosix(6)majorregionswhichalsocorrespondtothemajorgovernmentdivisions.Thealluvialplainsthatmakeup90%ofthecountryareveryflatandneverrisemorethan10mabovesealevel.Thecountryliesonamajorgeographicalfault,althoughmajorseismiceventsarerare.
Theclimateissubtropicalandtropicalandtemperaturesrangefromanaveragedaytimelowof21Cinthecoolermonthsoftheyearto35Cinthehottestmonths.Annualrainfallvariesfrom1000mmupto5000mm,withthree-quartersoftheannualrainfalloccurringbetweenJuneandSeptember.Asubstantialareaofthecountryisunderfloodduringanormalmonsoonseason.
Thepopulationiscloseto130million,makingitoneofthemostdenselypopulatedcountriesintheworld.BanglaisthenationallanguageofBangladesh.Beingpredominatelyagricultural,theaveragepercapitaincomeisUS$440perannum.ThepopulationispredominatelyMuslimwithsome10%HindualongwithminoritiesofBuddhismandChristianity.
Majorports:ChittagongisthemainbusyseaportofBangladesh.Mongla(nearKhulna)istheotherseaportwhichisbeingupgradedbyGoB.
Airports:Dhakaisthestandardinternationalairport,whereasChittagongandSylhetaretwosmallerinternationalairportswithlimitedfacilities.
ProjectSite
TheProjectsiteissituatedinthesoutheasternpartofBangladeshatChittagongandwithintheadministrativedivisionofChittagong.Itisproposedtoconstructa4-laneroadbridgewithAsianHighwayStandardabout50mupstreamofShahAmanatBridgeontheChittagong-Cox’sBazarHighwayN-1.Itisexpectedthattheconstructionofthebridgewillbecommencedinthe1stquarterof2006andwillbecompletedovera33monthsperiod.
Theprojectiscomposedofasinglecontractpackage.Theworksincludedesignandconstructionofapproximately950mlongbridge,approachroad,riverbankprotectionwork,tollplazawithcomputerizedtollingboothsutilities,rightofwayfencing,bridgerelatedancillaryworks,etc.includingdismantlingandremovaloftheexistingShahAmanatBridge.
Relevantinformationinrespectofthesitearegivenbelow:
ApproximateLongitude : 91o50′to91o55′andLatitude(22o20′to22o25′)
Terraintype:Alluvial-cumPiedmontPlain
Hottestmonth:April-May
ColdestMonth:December-January
AnnualAverageTemperature : 13.5oC(inwinter)and32.5oC(insummer)
RainfallSeason(monsoon):JunetoSeptember
Annualaveragerainfall:2,687mm
Visibility:Generallyclear.
1.1.2 GeneralInformation
Labour
Alargepoolofunskilledlabourisavailablealthoughitshrinksattimesofcropharvesting.Thereisashortageofskilledlabour.
ConstructionMaterial
Allconstructionmaterialswillrequiretransportationtotheprojectarea.Soilfortheembankmentconstructionwillbesuppliedbythecontractorasindicatedinthespecification.Noborrowpitwillbeallowedbythesideoftheroad.
Singlegradefinesandisavailablefromrivers/streamsnearbytheprojectarea.Well-gradedcoarsesandisavailablefromthehugefandepositsinthenorthernpartofSylhetandalsoinlimitedareasofnortherndistrictsPanchagharandLalmonirhat.
GoodqualitystonesasboulderandgravelareavailableinnorthernpartofSylhetandalsoinlimitedareasofnortherndistrictsPanchagharandLalmonirhat.RockmaterialsarealsoavailablefromMadhayparahardrockminingproject,whichareencouragedtouseinallconcreteandrivertrainingworkssofarastheysatisfythespecificationrequirement.Thereisascarcityofgoodqualitystoneinthecountry.Stonesarealsoimportedfromacrossthenationalboundary.
Well-burntbrickaggregatesareusedinthesub-baseandlowerpartofthebase.Brickfieldsexistwithinreasonabledistancesfromtheprojectsites.Goodqualitywell-burntbrickscanbeavailableifcoalburningisensured.Coalmayrequireimportation.
Bitumen(80/100grade)isproducedonlybyonerefineryinthecountry.Therefinerymayalsosupplybitumenofgrade60/70iftheorderisplacedforsufficientquantityandadequatelyinadvanceoftherequirement.Theproductionoftherefineryisnotadequatetomeetthedemandofthecountry.Itmayrequireimportation.
Cementisproducedinthecountry.Butindigenouscementsatisfiesabout50%oftotalneedofthecountry;theshortfallisbeingmetbyimportation.
Reinforcingsteel(bothmildandhighgrade)areproducedinthecountry.However,aguaranteeofquality,quantityanddeliveryscheduleisimportant.Partofthesematerialsmayneedimportation.NeopreneandotherBearings,STUs,prestressingsteelwithfixingdevicesandstressingequipment,willallrequireimportation.
1.1.3 DescriptionofWorks
ThecontractinvolvesthefollowingMajorworkitems
A. GeneralandSiteFacilities
OfficeAccommodationfor :400m2(approx.)
theEngineerandtheConsultant
SiteResidentialAccommodationfor:(Asdetailedhereafter)
theEngineerandtheConsultant
TransportfortheEngineerandtheConsultant:(Asdetailedhereafter)
B. ConstructionofBridge
i) LengthoftheBridge : 950m(approx.)long
ii) TypeofFoundation:Cast-in-SituRCCpile/RCCCaissons/SteelPile/CompositePile,etc.
iii) PierandAbutment :RCCtwincolumnwithPiercap/Bentcap/Walls/Shafts/Pylon
iv) SuperStructure :Pre-stressedConcreteExtradosed
v) FootpathwithRailing:TrafficRailing
vi) Bridgedeckdrainage : Directtoriver
C. ApproachRoadwithstructures
i) BridgeApproach : 1500m(approximately)
ii) ServiceRoads : 2600m(approximately)
iii) DrainageStructure : 1no
iv) DrainageCulverts : 100m(approximately)
D. RiverBankProtectionWork
i) GuideBundatRiverBank :350m(approximately)
ii) AbutmentSlopeProtectionwithCCblock : Bothsides
E. TollPlazaandTollCollectionSystem
i) TollBooths : Threeboothsineachdirection
ii) TollCanopy : Coveringallsixbooths
iii) AssociatedSignage : Showingtollrates,laneno,warningandotherinformation
iv) Control-cum-MaintenanceBuildings : Twostoriedbuildingof300m2perfloor
v) ComputerizedTollCollectionSystem : Hardwareandsoftwareforsixlaneprocessor,twoplazaandcentralcontrolsystem
F. AssociatedWorks
i) GeneralFillingofSiteArea : AboveHFL
ii) LandScapingincludingPlantation : 25Hectors(approximately)
andTurfing
iii) EnvironmentalMitigationMeasures : Asrequiredandspecified
iv) TrafficDiversionandTraffic : Asrequired
ManagementduringConstruction
v) ProvisionforTrainingofEmployees : O&M
G. MechanicalandElectricalWorks
i) PowerSupplySystem : ProjectSub-stationConnectiontoPDB/REBline
ii) StandbyGenerator : Asbackupsourceofpower
iii) NormalPowerSupply : Asrequiredwithmeter
iv) UPStoTollCollectionSystem : Asrequired
v) ElectricalSub-StationwithSwitchGear : BothHTandLT
vi) Bridgelightingbothinsideandoutside : Asrequired
BoxGirder
vii) NavigationAids : Ateachbridgepier
viii) Lighting&SmallPowerInstallation : Bridge&approachroad
ix) Earthing&LightningProtectionSystem : Bridgeandtollplaza
x) IntruderAlarm&EntranceControl : Tollplazaandcontrolbuilding
H. AncillaryWorks
i) RoadsideSurface&ToeSideDrain : Asrequired
ii) Guard&KilometerPost : Asrequired
iii) GuardRail/SafetyFench : Asrequired
iv) RoadSigns&Markings : Asrequired
v) RoWFenchingandMarketPost : Asrequired
vi) KerbsandDrainageOutlet : Asrequired
vii) Bus-Bay : Asrequired
viii) Barrier/LaneDivider : Asrequired
ix) Footpaths : Asrequired
x) ServiceDucts : Asrequired
xi) RelocationofUtilities : Asrequired
xii) Connectionwithexistingroadsystem : Asrequired
inChittagongandCox’sBazarend
I. Dismantling,removalofexisting : Asrequired
ShahAmanatBridge
J. Maintenance(Duringdefectsliabilityperiod):Aspercontract
1.1.4 Standards
WhenmaterialsorworkmanshiparerequiredbytheseSpecificationstomeetorexceedspecificallynamedcodesorstandards,itistheContractor'sresponsibilitytoprovidesuchspecificallynamedcodesorstandards.Thespecifiedcodesandstandardsestablishthequalityrequirementsforthevarioustypesofworktobeperformedandthemethodsfortestingfordeterminationthattherequiredqualityisachieved.
Allthecodesofpractice,standardsandspecificationsapplicableshallbethelatesteditionwithallcorrectionsandincorporationsason28(twentyeight)daysbeforethefinaldateforsubmissionofthebid.
IntheabsenceofanydefiniteprovisionsinthespecificationsonanyparticularissuereferencemaybemadetothelatestcodesofAASHTO,ASTMandBSstandardswhichensureanequalorhigherqualitythanthestandardsmentioned.Whereeventhesearesilent,theconstructionandcompletionoftheWorksandrelevanttestsshallconformtosoundengineeringpracticeand,incaseofanydisputearisingoutoftheinterpretationoftheabove,thedecisionoftheEngineershallbefinalandbindingontheContractor.
1.2 FIELDOFFICEANDFACILITIESFORTHEENGINEERANDTHECONSULTANTS
1.2.1 BuildingsfortheEngineerandtheConsultants
Inadditiontotheofficespaceandotherbuildingsrequiredforhisownuse,theContractorshallprovideandmaintainanumberoffurnishedbuildingsfortheuseoftheEngineerandtheConsultants.Requirementsforthebuildings,includingoverallsize,numberandsizeofindividualrooms,constructionandfurniturearetobeasdetailedinspecificationorBillofQuantitiesorasinstructedbytheEngineer.
ThebuildingsshallbemaintainedinasecureandwatertightconditionbytheContractoruntilcompletionoftheWorksorasotherwiseinstructedbytheEngineerandshall,atalltimes,beprovidedwithcommunicationsnetwork,electricity,potablewaterandsewerage.
TheContractorshallsubmitfortheapprovaloftheEngineerbeforeconstruction,plansanddrawingsshowingproposeddetailsandlocationforthebuildings,includingfoundations,accessroads,landscaping,carparkingfacilities,layoutofelectricalandwatersuppliesandhardstandingsthereto.TheEngineermayrequirerevisionoftheplanspriortogivingapprovalforconstruction.TheContractorshallalsosubmitdetailsofproposedfurnitureandfittingstotheEngineerforapproval.Theseitemsshallgenerallybeofthebestqualityobtainablelocally.
TheContractorshallprovide,andmaintain(alltotheapprovaloftheEngineer)adequateareaofprojectsiteofficefacilitiesfortheEngineerandtheConsultantsincludingfurnishings,security,utilities(sewerage,power,water,telephoneetc)&services.Thetotalofficespacerequiredwillbenominally400sq.m.Sinceitisverylikelytheofficewillnotbeprovidedimmediatelyasthecontractcommences,theConsultantswillrequiretemporaryofficespaceuntilsuchtimeasthepermanentbuildingsarecompleted.Thisdelayisassumedtobethree(3)months.FromthetimeofNoticetoproceeduntiltheproperFieldOfficefacilitiesarecompletedandkeyshandedoverbytheContractor,theContractorshallprovideinalocationtobeagreedwiththeEngineer,temporaryofficeaccommodationfortheEngineerandtheConsultantswithinone(1)monthsfromthedateonwhichhecommencestheworkonsiteuntilsuchtimeasallpermanentofficefacilitieshavebeenprovidedbytheContractorandaccepted.ThetemporaryofficeaccommodationshallbeofasizeandstandardandapprovedbytheEngineerandtheConsultants.TheContractorshallnotbepaidseparatelyfortheprovisionoftemporaryfacilities,andthecostshallbedeemedtohavebeenincludedintheratesofsuchfacilitiesinBoQitems.
Thefieldoffices,completewithfurnishings,fittings,accessroadsandhardstandingsshallbereadyforoccupationbytheEngineerwithinfour(4)monthsfromthedateoftheLetterofacceptance.
TheContractorshallprovideallnecessarysecuritysafeguardsincluding;perimeterfencing,externallightingwatchmenforthefacilitiesatalltimesandsuchsecurityshallbesubjecttotheapprovaloftheEngineer.ThefollowingsupportstaffshallbeprovidedbytheContractortoworkforthesupervisionteamonsiteduringthewholeperiodoftheconstructionandmaintenancestageofthecontract.
PositionNo.ofPersons
OfficeAssistant/WordProcessor : 2nos.
SecurityGuard : 8nos.
SkilledLabourers/SurveyAssistant : 8nos.
TeaBoy : 2nos.
Cleaner : 3nos.
Messenger/Peon : 4nos.
ThecontractorwillsupplyskilledandunskilledlabourstoassisttheEngineer’ssurveyteamasrequired.StaffconsideredunsuitablebytheEngineershallbereplaced.Allthestaffmayberequiredtoworkuptoto10(ten)hoursaday.
TheContractorshallallowforroutinemaintenanceandservicingoffieldofficefacilitieswhichshallinclude,butnotbelimitedtodailydusting,cleaningandjanitorialwork;windowwashingandwetfloormoppingnecessarymaintenanceandrepairtomechanical,air-conditioning,heating,electricalandplumbingsystems;providingpotabledrinkingwaterandalltoiletsupplies;disposalofallwaste;maintenanceofinteriorandexteriorofbuildings,groundsandpavedareasincludingandrepairsthereto.Maintenanceshallalsoincludeprovidingwater,gas,electricityandlocaltelephoneservicesandanyothermaintenanceorserviceasspecifiedhereinorasfurtherdirectedbytheEngineer.MaintenanceworkbythecontractorshallbegenerallyscheduledoutsidethenormalworkinghoursoftheEngineerandasdirectedbytheEngineer.
Thegroundlevelsofallthesitefacilitiesaswellasthoseoftheaccessroadstheretoshallbe1000mmabovethe25-yearhighfloodlevel.Thefinishedfloorlevelsofallthebuildingsprovidedunderthesitefacilitiesshallbe500mmabovetheadjoiningdevelopedground.ThegeneralsitefacilitiesshallbedevelopedandconstructedonGovernmentlandsallocatedbytheEmployer.ThesefacilitieswillremainthepropertyoftheEmployer.
Anyconstructionaldetails,specificationortypeofmaterialorworkmanship,whichwerenotclearlyspecifiedherein,shallrequirepriorapprovaloftheEngineer.
1.2.2 Sanitation
TheContractorshallprovideadequatewater-bornesanitationandrefusecollectionanddisposal,complyingwiththeLawsofBangladeshandalllocalBy-Laws,andtothesatisfactionoftheEngineer,foralloffices,laboratories,workshops,houses,huts,camps,etcerectedbythecontractorandmaintainedinhiscareshouldastandbygeneratorbeconsiderednecessarythecontractormustprovidesame.
1.2.3 WaterSupply
TheContractorshallprovidepotablewater,complyingwiththeLawsofBangladeshandalllocalBy-Laws,andtothesatisfactionoftheEngineer,foralloffices,laboratories,workshops,houses,huts,camps,etcerectedbythecontractorandmaintainedinhiscare.
1.2.4 PowerSupply
TheContractorshallprovideareliableuninterruptedpowersupply,withbackupprovisionsifrequiredbytheEngineer,complyingwiththeLawsofBangladeshandalllocalBy-Laws,andtothesatisfactionoftheEngineer,foralloffices,laboratories,workshops,houses,huts,camps,erectedbythecontractorandmaintainedinhiscare.Standbygeneratorsofadequatecapacitiesshallbeprovidedforuninterruptedpowersupplyatsiteofficeandcamps.
1.2.5 GeneralRequirements
a) Projectsiteofficeandresidenceshallbeofoneortwo-storiedpermanentconstruction,withdesignandconstructionbeingsuchthattwofurtherfloorscanbeaddedinfuture.FormorespecificdetailsseeClause-1.2.7.
b) MinimumfloorareaasdetailedinBillofQuantitiesshallconsistofinadditiontoOfficeSpaces,aconferenceroom(capableofsitting12persons)lockableofficesforseniorstaff,generalopenplanofficearea,kitchen,storageroom,toiletsandshowerfacilities,completewithshowersandwashbasinsandshallincludecupboards,fans,shelving,kitchensinkandbench.Acoveredparkingcapableofhousingsix(6)vehiclesshallbeerectedadjacenttothefieldoffice.
c) Officesandfacilitiesshallbelocatedinaccordancewiththegenerallocationandsiteplansasapproved.
d) Thefacilitymustbesitedsoastobefreeofpollutionfromanyconstructionoperations.
e) Buildingsmustbepermanentconstructionandbestructurallysound,weatherproofwithfloorsraisedabovegroundandshallbeprovidedwiththeminimumregulationceilingheight.Eachfacilityshallbeentirelyairconditioned,withtheexceptionofkitchens,corridors,toiletrooms,pantriesandstores/storagesheds.
f) Thefacilityshallbeprovidedwithelectriclighting,powerandwithtelephoneserviceforsoleusebytheEngineerandtheConsultants.Alllightingshallberecessedorsurfacemountedfluorescentlightswithdetachablediffusers.Eachofficeorareashallbeequippedwithelectricaloutletssetinthewallsat600mmabovethefloorandspacedatapproximately2metrescentres.TheContractorshouldprovideandmaintainalandlinetelecommunicationslinkwhichwillallowtelephonecallstobemadebetweentheDhakabaseofficeandprojectsiteofficeatalltimes.InadditiontheContractorshouldalsoprovideandmaintain12(twelve)setsofmobiletelephonefacilitiesfortheEngineerandtheConsultant.
g) TheContractorshallberesponsibleforandpaypromptlyallcharges,feesorotherexpensesforprovidingandmaintainingtheEngineer’ssitesofficefacilities,allelectric,gas,water,telephoneservicesandotherutilitiesduringtheperiodofconstructionoftheworksandbeyonduntiltheprojectCompletionDate.
h) Flooring:Forinternalfloorthesurfaceofthefoundationshallbepreparedperfectlylevelandfinishedwithprecastmosaictiles.ForverandahandbathroomthesurfaceshallbepreparedwithappropriateslopetodrainoutwaterandfinishedwithceramictilesandforotherroomsthesurfacemaybekeptlevelorwithgentleslopeasdirectedbytheEngineer.
i) DoorandWindows:Doorsshallbemadefromwood,asdirectedbytheEngineer.Alldoorsshallbelockablefrombothsides.Windowsshallbehorizontalslidingwithanodizedaluminiumframes,glazedwithtintedglassorwithplainglassandrollerblindsandshallbelockablefromtheinsideonly.Allwindowopeningsshallbeburglarproofandprovidedwithinsectscreens.
j) Thesanitary,watersupply,plumbinganddrainageworkshallconformtoNationalPlumbingCode(ASA-A40.8-1955)asamendedfromtimetotimebytheAmericanSocietyofMechanicalEngineersorasdirectedbytheEngineer.
AllwastewatershallbedisposedundergroundandasapprovedbytheEngineer.TheContractorshallperformpercolationtestsatthelocationoftheleachfieldorpit,andthesizeoftheleachfieldorpitwillbesubjecttotheresultsofthesetestsandtheapprovaloftheEngineer.
Theseptictanks,whosesizeapprovedbytheengineer,shallbeofreinforcedconcreteandequippedwithproperinletandoutletbafflesandsealedaccesshatch.Thesizeshallbesufficienttooperateforatleastoneyearwithoutthesolidsoverflowingintotheleachfields.
k) TheelectricalinstallationshallingeneralbecarriedoutinconformitywiththeElectricityRulesoftheGovt.ofthePeople'sRepublicofBangladesh.AnyspecialrequirementofElectricalInspector,Govt.ofthePeople'sRepublicofBangladeshorthePowerDevelopmentBoardorTelegraphandTelephoneBoardoranyotherLegalAuthorityshallalsobecompliedwithbytheContractorincarryingouttheseworks.
l) FurnitureandFixturesofapprovedqualityfortheofficeandlivingaccommodationshallbeprovidedasdescribedhereafterwiththelisttobeapprovedbytheEngineer.
m) EquipmentandAppliancesforEngineerandConsultantsoffices.
A. EquipmentandappliancesforprojectsiteofficeshallconsistoftheitemsasspecifiedunderClause-1.2.8.
B. OfficeComputers,EquipmentandAppliancesofprojectsiteofficemachines
i) DeskTopPC:4nosandLaptopPC:3noswiththefollowingminimumstandardsincludingnecessarysoftwareforofficework,CADetc.
DesktopPC:4nos(BrandMachine)withthefollowingminimumHardwareRequirements:
Processor
IntelPentium4processor670SupportingHyper-ThreadingTechnology
(Cache-2MBL2,ClockSpeed-3.80GHz,FrontSideBus-800MHz)
Motherboard
IntelDesktopBoardD955XCS
HDD
Maxtor160GBHardDrive(7200RPM)
Memory
1GB(1024MB)DualChannelDDR2SDRAMat533MHz-2DIMMs
GraphicsCard
256MBNvidiaGeForce7Series
Monitor
17inchUltrasharpDigitalFlatPanel(widescreen)
CD-RW
52XWrite/32XRe-Write/52XCD-ROM
DVDRom
16xDVDROM
SoundCard
CreativeSoundBlasterAudigy2
Speaker
CreativeInspire4.1
Modem
56KPCIDataFaxModem
FDD
3.5inFloppyDrive(1.44MB)
NetworkCard
IntelPRO/1000PTDesktopAdapter
Keyboard&Mouse
PS/2Keyboard+OpticalPS/2Mouse
Casing
ATXP-4Thermal
UPS
600VA
Table
ComputerTable
LapTopPC:3nos(BrandMachine)withthefollowingminimumHardwareRequirements:
Processor
IntelPentiumM780Processor(2.26GHz,2ML2cache,533MHzFSB)w/Intel915GMChipset(IntelCentrinomobiletechnology)
Memory
1GB(1024MB)DualChannelDDR2SDRAMat533MHz2Dimm
HardDiskDrive
80GB7200rpmHardDrive
Display
17inchUltraSharp?WideScreenUXGADisplaywithTrueLife?
GraphicsCard
512MBNVIDIAGeForceCard
OpticalDrive
Double-layerDVD+CD-RW
OpticalDriveSpeed
24xCD-Write/24xCD-ReWrite/24xCD-ROM/8xDVD-ROM
NetworkCard
Integrated1GigabitNetworkCard
Modem
V.92data/faxhigh-speedmodem(56k)
WirelessNetworking
IntegratedIntelPRO/Wireless2915ABG(802.11a/b/g);
Bluetooth;FastInfrared
Battery
12-cellLithiumIonPrimaryBattery
FDD
ExternalUSBFloppyDrive
Keyboard
Keyboardwithdualpointingdevices
Mouse
BluetoothWirelessMouse
Carryingcases
ExecutiveLeatherCarryingcase
HeadPhones
Creative'sBluetoothHeadphone
AdditionalStorageDevice
512MBUSBPenDrive
AdditionalBattery
Additional12-cellLithiumIonBattery(01set)
AdditionalPowerCable
AdditionalPowerCable(01set)
SoftwarerequirementsforbothDesktopandLaptop
Operatingsystems
MicrosoftWindowsXPProfessional
Officeproductivitysoftware
MicrosoftOffice2003withMicrosoftProject2003
Securitysoftware
NortonAntiVirus/McAfeeAntiVirus
ii)Printer:2nosHPLaserJet5100seriesorotherequivalentwiththefollowingminimumrequirements
PrintSpeed
21ppm
Processorspeed
300MHz
Resolution
1200x1200dpi
Papertrays
3
Inputcapacity
850Sheet
PaperHandling
100-sheetmulti-purposetray,250-sheetfeedertray,500-sheetfeedertray,autoduplexprintingaccessory
Mediasizes
Letter,A3,A4,A5,Executive,Legal,B4,B5,Tabloid,no.10envelopes,
Tray1:3x5into12.28x18.5in;Tray2:5.8x8.3into11x17in
Duplexprinting(printingonbothsidesofpaper)
Automatic(standard)
Memory
32MB
Connectivity
Paralleland10/100Base-TXEthernet
Environments
PCandMacCompatible
Warranty
1YearOnSitecoveringpartsandlabor
iii) Scanner,HPScanjet7650seriesorequivalentwiththefollowingminimumrequirements
ScannerType
Flatbed
Scanresolution,enhanced
Upto999999dpi
Scanresolution,hardware
2400x2400dpi
Bitdepth
48-bit
Levelsofgrayscale
256
Automaticdocumentfeeder
Standard,50sheets
Maximumscansize
8.5x14in
Connectivity
Hi-speedUSB(compatiblewithUSB2.0specifications)
Warranty
One-yearlimitedhardwarewarranty
iv) DigitalCamera:2noswiththefollowingspecification
ImagingDevice
21.5x14.4mm10.3Megapixel
RecordingMedia
MemoryStick?Media,MemoryStickPRO?Media,MicrodriveandCompactFlash?TypeI/IIMedia
Zoom
5XOptical,2XDigital,0-15XSmartZoom
FocalLength
14.3-71.5mm
35mmEquivalent
24-120mm
FilterDiameter
67mm
Aperture
f2.4-4.8(minimumf16)
Focus
5AreaMulti-PointAFwithManualSelect
MinimumFocusDistance
19.7"(50cm)(Wide/Tele)
MacroFocusDistance
13.7"(35cm)
ApertureRange
16Step,f2.8-16.0
ShutterSpeed
1/2000-30seconds;Bulbupto3minutes
ManualExposure
±2.0EV,1/3EVStep
ColorLCD
2.0"134KPixelsLCDwithF
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025-2030年鋼琴行業(yè)市場(chǎng)現(xiàn)狀供需分析及投資評(píng)估規(guī)劃分析研究報(bào)告
- 2025-2030年車載機(jī)芯行業(yè)市場(chǎng)發(fā)展分析與發(fā)展趨勢(shì)及投資前景預(yù)測(cè)報(bào)告
- 2025-2030年視頻會(huì)議行業(yè)市場(chǎng)發(fā)展分析及前景趨勢(shì)與投資戰(zhàn)略研究報(bào)告
- 2025-2030年船體清潔機(jī)器人市場(chǎng)市場(chǎng)現(xiàn)狀供需分析及投資評(píng)估規(guī)劃分析研究報(bào)告
- 2025-2030年膠質(zhì)細(xì)胞源性神經(jīng)營(yíng)養(yǎng)因子行業(yè)市場(chǎng)現(xiàn)狀供需分析及投資評(píng)估規(guī)劃分析研究報(bào)告
- 2025-2030年石油鉆采用設(shè)備行業(yè)市場(chǎng)發(fā)展分析及發(fā)展趨勢(shì)與投資研究報(bào)告
- 2025-2030年電腦鼠標(biāo)產(chǎn)業(yè)行業(yè)市場(chǎng)現(xiàn)狀供需分析及投資評(píng)估規(guī)劃分析研究報(bào)告
- 2025-2030年電熱水龍頭產(chǎn)業(yè)行業(yè)市場(chǎng)現(xiàn)狀供需分析及投資評(píng)估規(guī)劃分析研究報(bào)告
- 2025-2030年汽車減震器行業(yè)市場(chǎng)深度調(diào)研及競(jìng)爭(zhēng)格局與投資研究報(bào)告
- 2025-2030年橡皮筋行業(yè)風(fēng)險(xiǎn)投資發(fā)展分析及投資融資策略研究報(bào)告
- 工學(xué)一體化教學(xué)參考工具體例格式9:學(xué)習(xí)任務(wù)工作頁(yè)
- 初中《道德與法治》課堂有效教學(xué)的建構(gòu)、實(shí)施與創(chuàng)新
- 供應(yīng)鏈公司成立方案
- 質(zhì)量風(fēng)險(xiǎn)與機(jī)遇分析評(píng)價(jià)表完整
- 寵物美容與護(hù)理PPT全套完整教學(xué)課件
- 北京市行政處罰案卷標(biāo)準(zhǔn)和評(píng)查評(píng)分細(xì)則
- 現(xiàn)澆混凝土箱梁專項(xiàng)施工方案
- 美容師初級(jí)操作技能考核評(píng)分記錄表
- 國(guó)產(chǎn)數(shù)據(jù)庫(kù)發(fā)展研究報(bào)告
- 教師專業(yè)發(fā)展第9章-教師個(gè)人自傳課件
- 企業(yè)主要負(fù)責(zé)人履行安全生產(chǎn)職責(zé)專項(xiàng)檢查表
評(píng)論
0/150
提交評(píng)論