電力專業(yè)英語4-繼電保護(hù)2_第1頁
電力專業(yè)英語4-繼電保護(hù)2_第2頁
電力專業(yè)英語4-繼電保護(hù)2_第3頁
電力專業(yè)英語4-繼電保護(hù)2_第4頁
電力專業(yè)英語4-繼電保護(hù)2_第5頁
已閱讀5頁,還剩10頁未讀, 繼續(xù)免費(fèi)閱讀

下載本文檔

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)

文檔簡介

電力專業(yè)英語4

--繼電保護(hù)2電氣工程學(xué)院12/27/20231繼電保護(hù)2DistanceRelay距離保護(hù)UndervoltageRelay低電壓保護(hù)OvervoltageRelay過電壓保護(hù)BlockingRelay閉鎖繼電器PhaseAngleorOutofStepRelay失步保護(hù)FrequencyRelay頻率繼電器DirectionalPowerRelay方向功率繼電器InstantaneousOvercurrentRelay瞬時(shí)過流保護(hù)DifferentialRelay差動(dòng)保護(hù)12/27/20232GroundingSystemFormerly,manypowersystemswereungroundedsystemsusingdelta-deltatransformers.Ungroundedsystemssufferformseveralproblems,includingtransientovervoltagesthatnecessitatetheuseoftwosurgearrestersforasingle-phasetransformer(oneoneachsideofthewinding),andtroublewithrapid,automaticclearingoftheverycommonphasetogroundshortcircuit.以前,許多電力系統(tǒng)采用角型接線變壓器,為不接地系統(tǒng)。不接地系統(tǒng)會(huì)帶來很多嚴(yán)重的問題,包括暫態(tài)過電壓,因此,即使是單相變壓器,也需要分別在原邊和副邊繞組各安裝一個(gè)避雷器。而且對(duì)于非常常見的相接地故障的快速自動(dòng)切除非常困難。12/27/20233Anungroundedsystemisconnectedtogroundonlybystraycapacitances,soasinglephasetogroundshortcircuitdrawsverylittlefaultcurrent.不接地系統(tǒng)通過隔離電容接地,因此單相接地故障會(huì)產(chǎn)生非常小的故障電流Toallowrapiddetectionandautomaticclearingofgroundfaults,andtoreduceinsulationandarrestercosts,groundedsystemshavebecomemorecommonthanungroundedones.為了快速檢測(cè)和去除接地故障,并且降低投資在隔離設(shè)備和避雷器上的費(fèi)用,接地系統(tǒng)的應(yīng)用越來越廣泛。12/27/20234Inmanycases,thepowertransformersinagroundedsystemareconnecteddeltawye,withthewyeneutralgroundedtothesubstationgroundmat.很多情況下,接地系統(tǒng)中的電力變壓器的連接方式為三角星型接線,星型接線的中性點(diǎn)和變電站的接地網(wǎng)相連。Generatorsandstep-downtransformersservingonlythree-phaseloadsareoftengroundedthrougharesistancetolimitthegroundfaultcurrenttolowvalues.發(fā)電機(jī)和只帶三相負(fù)荷的降壓變壓器一般通過電阻接地,以降低接地故障電流的大小。12/27/20235Generatorstep-uptransformersandstep-downtransformersservingfour-wiredistributionsystemareusuallyconnecteddeltaontheprimaryandwyeonthesecondary.Rememberprimarymeansinputandsecondmeansoutput,soastep-uptransformerprimaryisthelow-voltagesidebutastep-downtransformerprimaryisthehigh-voltageside.發(fā)電機(jī)升壓變壓器和向四線配電系統(tǒng)供電的降壓變壓器通常在原邊側(cè)為三角型連接,在副邊側(cè)位星型鏈接。需要注意的是原邊指輸入,副邊指輸出,因此升壓變壓器的原邊為低壓側(cè),但降壓變壓器的原邊為高壓側(cè)。12/27/20236Distributiontransformersonfour-wiresystemsareconnectedphasetoneutral(singlephase)orwye(threephase)ontheprimaryside.Thesecondarysideofthree-phasedistributiontransformersmaybeconnectedineitherwyeordelta.四線系統(tǒng)的配電變壓器的原邊連接在相和中線上〔單相變壓器〕或連接成星型〔三相變壓器〕。三相配電變壓器的副邊可以星型或三角型連接。12/27/20237Thewye-wyedistributiontransformerisusedforfour-wire(threephaseconductorsandaneutralconductor)systems,andthewye-deltadistributiontransformerisusuallyconnectedwiththebankneutralnotconnectedtoground.星星連接配電變壓器用于四線系統(tǒng)〔三相導(dǎo)線和中線〕,星角接線配電變壓器的中性點(diǎn)通常不接地。12/27/20238Iftheneutralisgrounded,thebanktriestogroundthefeeder,andwhengroundfaultsoccurontheprimaryside,thedistributionbankswillsupplygroundcurrent.Thisusuallycausesalargenumberofblownfusesonwye-deltadistributiontransformerswithgroundedneutrals.如果中性點(diǎn)接地,….,當(dāng)在原邊側(cè)發(fā)生接地故障時(shí),配電變壓器組中有接地電流流過。這會(huì)導(dǎo)致星型中性點(diǎn)接地接線的配電變壓器的保險(xiǎn)熔斷。12/27/20239Floatingthebankneutralalleviatestheproblem,butmaycauseovervoltageproblemssuchasferroresonance.Wye-wyebanksavoidtheferroresonanceproblemsincetheyinvariablyhavegroundedneutralsonbothsides.變壓器中性點(diǎn)浮地能減輕這一問題,但可能造成過電壓問題,例如鐵磁共振。星星連接變壓器組不會(huì)產(chǎn)生鐵磁共振問題,因?yàn)樵谠吅透边呏行渣c(diǎn)均接地。12/27/202310Instrumenttransformers儀用〔或測(cè)量用〕互感器Instrumenttransformersaretheinputtransducerforprotectiverelays,butalsometering(bothfrorevenuemeteringandfordataacquisition).Thetwomaintypesofinstrumenttransformersarecurrenttransformers(CTs)andpotentialtransformers(PT’s).Thelatterarealsocalledvoltagetransformers(VT’s),withnodifferenceintended.測(cè)量用互感器指的是保護(hù)繼電器的輸入傳感器,也指計(jì)量儀表〔例如電費(fèi)計(jì)量和數(shù)據(jù)采集〕的輸入傳感器。兩種主要的測(cè)量用互感器為電流互感器〔CT〕和電壓互感器〔PT〕,后者也簡稱VT。12/27/202311TheCTactstostepthecurrentdown,sayfrom1000Aontheprimaryto5Aonthesecondary.ThiswouldgiveaCTratioof1000:5Aor200:1A,andwouldrequire200turnsonthesecondary(assumingoneprimary“turn〞).CT的作用是降低電流,例如將原邊1000A的電流降至副邊的5A。那么CT的變比為1000:5A或200:1A,副邊繞組的匝數(shù)為200〔假設(shè)原邊繞組匝數(shù)為1〕12/27/202312Currenttransformersecondariesaretypicallyratedat5A,althoughsomeareratedat1A.Thisisthecontinuousrating,anditmaybeexceededbyafactorof10or20forashorttime,especiallyduringashortcircuitinsupplyingrelaysthatprovideovercurrentprotection.電流互感器二次側(cè)典型額定電流為5A,有時(shí)為1A.這只是額定標(biāo)稱值,其二次側(cè)允許短時(shí)過電流10-20倍,尤其是作為過流保護(hù)的輸入傳感器,有短路電流流過時(shí)。12/27/202313Currenttransformersforrelayingpurposesaregivenaccuracyclassratings,suchasC400orT400(sometimeswrittenas10C400or10T400).TheletterCindicatesthatitsperformancemaybecalculatedfromitsmagnetizationcurve.TheletterTindicatesthatitsperformancemustbedeterminedbytest.保護(hù)用電流互感器均給出其〔測(cè)量〕精度等級(jí),例如C400或T400〔有些標(biāo)為10C400或10T400〕。字母C表示其特性通過其磁化曲線計(jì)算出來。字母T表示其特性由實(shí)驗(yàn)決定。12/27/202314ThenumberfollowingtheletterCorTisthevoltagerating:thesecondaryvoltageproducedby20timesratedsecondarycurrent

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論