![永新縣里田鎮(zhèn)湯溪村光伏發(fā)電外送110KV線路工程項目電磁環(huán)境影響專項評價報告_第1頁](http://file4.renrendoc.com/view10/M03/29/28/wKhkGWXV18WAPvS2AACEjwcjttc012.jpg)
![永新縣里田鎮(zhèn)湯溪村光伏發(fā)電外送110KV線路工程項目電磁環(huán)境影響專項評價報告_第2頁](http://file4.renrendoc.com/view10/M03/29/28/wKhkGWXV18WAPvS2AACEjwcjttc0122.jpg)
![永新縣里田鎮(zhèn)湯溪村光伏發(fā)電外送110KV線路工程項目電磁環(huán)境影響專項評價報告_第3頁](http://file4.renrendoc.com/view10/M03/29/28/wKhkGWXV18WAPvS2AACEjwcjttc0123.jpg)
![永新縣里田鎮(zhèn)湯溪村光伏發(fā)電外送110KV線路工程項目電磁環(huán)境影響專項評價報告_第4頁](http://file4.renrendoc.com/view10/M03/29/28/wKhkGWXV18WAPvS2AACEjwcjttc0124.jpg)
![永新縣里田鎮(zhèn)湯溪村光伏發(fā)電外送110KV線路工程項目電磁環(huán)境影響專項評價報告_第5頁](http://file4.renrendoc.com/view10/M03/29/28/wKhkGWXV18WAPvS2AACEjwcjttc0125.jpg)
版權說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權,請進行舉報或認領
文檔簡介
永新縣里田鎮(zhèn)湯溪村光伏發(fā)電外送110kV線路工程項目電磁環(huán)境影響專項評價目錄TOC\o"1-2"\h\z\u1 總則 3 評價依據(jù) 3 評價工作等級、范圍 3 電磁環(huán)境保護目標 4 評價標準 42 電磁環(huán)境現(xiàn)狀評價 5 監(jiān)測期間氣象條件及監(jiān)測單位 5 監(jiān)測依據(jù) 5 監(jiān)測布點 5 監(jiān)測結(jié)果 6 現(xiàn)狀評價 63 電磁環(huán)境影響評價 7 工頻電磁場境影響預測 7 對輸電線路的影響 18 變電站擴建間隔影響分析 19 電磁防護措施 19 監(jiān)測計劃 204 電磁環(huán)境影響專題評價結(jié)論 21總則評價依據(jù)1.1.1環(huán)境保護法規(guī)、條例和文件1)《中華人民共和國環(huán)境保護法》(2014年修訂2015年1月1日實施);2)《中華人民共和國環(huán)境影響評價法》(2018年12月29日起施行);3)《中華人民共和國電力法》(2018年12月29日起施行);4)《中華人民共和國環(huán)境噪聲污染防治法》(2018年12月29日修訂并施行);5)《中華人民共和國固體廢物污染環(huán)境防治法》(2020年9月1日修訂并施行);6)《建設項目環(huán)境保護管理條例》(2017年10月1日起施行);7)《電力設施保護條例》(2011年1月8日起施行);8)《建設項目環(huán)境影響評價分類管理名錄》(2021版);9)《江西省建設項目環(huán)境保護條例》(江西省人大常委會,2010年7月1日起施行);10)《環(huán)境影響評價公眾參與辦法》(生態(tài)環(huán)境部令第4號);1.1.2相關的標準和技術導則1)《電磁環(huán)境控制限值》(GB8702-2014);2)《環(huán)境影響評價技術導則輸變電工程》(HJ24-2020);3)《交流輸變電工程電磁環(huán)境監(jiān)測方法(試行)》(HJ681-2013);4)《輸變電建設項目環(huán)境保護技術要求》(HJ1113-2020);1.1.3其他1)環(huán)境影響評價委托書;2)《永新縣里田鎮(zhèn)湯溪村光伏發(fā)電外送110kV線路工程可行性研究報告》(吉安電力勘察設計所有限公司);3)建設單位提供的項目相關資料。評價工作等級、范圍依據(jù)《建設項目環(huán)境影響評價分類管理目錄》,本項目應該編制環(huán)境影響評價報告表。同時,根據(jù)《環(huán)境影響評價技術規(guī)范輸變電工程》(HJ24-2020),確定本項目的環(huán)境影響評價等級及范圍如下表。表1-1評價等級及評價范圍環(huán)境要素判定依據(jù)評價等級評價范圍電磁環(huán)境1.地下電纜2、110kV輸電線路邊導線地面投影外兩側(cè)各10m范圍內(nèi)無電磁環(huán)境敏感目標的架空線三級架空線路:邊導線投影外兩側(cè)各30m;里田變電站:擴建間隔側(cè)圍墻外30m范圍;地下電纜:管廊兩側(cè)邊緣各外延5m(水平距離)。電磁環(huán)境保護目標工程特點及工程區(qū)域環(huán)境狀況,確定本工程評價范圍內(nèi)無電磁環(huán)境保護目標。評價標準根據(jù)《電磁環(huán)境控制限值》(GB8702-2014),50Hz頻率下,環(huán)境中工頻電場強度的公眾曝露控制限值為4000V/m,工頻磁感應強度的公眾曝露控制限值為100μT。表1-2 公眾曝露控制限值頻率范圍電場強度E(V/m)磁場強度H(A/m)磁感應強度B(μT)等效平面波動率密度Seq(W/m2)1Hz~8Hz800032000/f240000/f2-8Hz~25Hz80004000/f5000/f-0.025kHz~1.2kHz200/f4/f5/f-1.2kHz~2.9kHz200/f3.34.1-2.9kHz~57kHz7010/f12/f-57kHz~100kHz4000/f10/f12/f-0.1MHz~3MHz400.10.1243MHz~30MHz67/f1/20.17f1/20.21f1/212/f30MHz~3000MHz120.0320.040.43000MHz~15000MHz0.22f1/20.00059f1/20.00074f1/2f/750015GHz~GHz270.0730.0922電磁環(huán)境現(xiàn)狀評價里田變電站站界的電磁環(huán)境現(xiàn)狀引用核工業(yè)二七O研究所出具的《吉安永新里田-高坪110kV線路工程》監(jiān)測報告(所環(huán)監(jiān)字(2018)第234號,見附件6),引用監(jiān)測點位為東北側(cè)擴建間隔處,與本項目擴建間隔相鄰,監(jiān)測日期2018年7月6日,符合《環(huán)境影響評價技術導則輸變電工程》(HJ24-2020)中,三級評價典型線位的電磁環(huán)境現(xiàn)狀可利用評價范圍內(nèi)已有的最近3年內(nèi)的電磁環(huán)境現(xiàn)狀監(jiān)測資料。沿線代表性點位電磁環(huán)境現(xiàn)狀委托江西中軒檢測科技有限公司進行監(jiān)測,報告編號為:〔中軒〕檢測字〔2021〕JX210430A(監(jiān)測報告見附件5),監(jiān)測時間為2021年5月4日。監(jiān)測期間氣象條件及監(jiān)測單位監(jiān)測期間氣象情況:2021-05-04氣象條件:無雨雪、無雷電;風向:西南風;風速:1.4m/s。監(jiān)測期間,里田鎮(zhèn)湯溪村光伏電站110Kv升壓站已經(jīng)開始運行,沿線架空線路已通電。監(jiān)測依據(jù)表2-1監(jiān)測依據(jù)及方法檢測類型檢測項目檢測方法/依據(jù)儀器名稱/型號檢出限電磁場工頻電場《交流輸變電工程電磁環(huán)境監(jiān)測方法(試行)》(HJ681-2013)工頻電場場強儀RJ-51V/m工頻磁場《交流輸變電工程電磁環(huán)境監(jiān)測方法(試行)》(HJ681-2013)工頻磁場場強儀RJ-5H0.1μT監(jiān)測布點根據(jù)《環(huán)境影響評價技術導則輸變電工程》(HJ24-2020)的要求并結(jié)合本項目實際,本項目線路周邊30m內(nèi)無電磁環(huán)境敏感點,總輸電線路小于100km,輸電線路代表性監(jiān)測點位按照均勻布點原則,在沿線評價范圍內(nèi)布設2個代表性監(jiān)測點位,同時在里田鎮(zhèn)湯溪村光伏電站110kV升壓站出線間隔西北圍墻外5m補充1個監(jiān)測點位(見附件監(jiān)測報告布點圖)。表2-2電磁環(huán)境現(xiàn)狀監(jiān)測布點情況編號監(jiān)測點地名經(jīng)緯度D1沿線代表性點位=1\*GB3①114°7′44.96400″,27°1′43.18200″D2沿線代表性點位=2\*GB3②114°7′15.22800″,27°1′46.43400″D3里田鎮(zhèn)湯溪村光伏電站110kV升壓站出線間隔西北圍墻外5m114°7′4.15200″,27°1′35.42400″D2(引用)里田變電站站界東北側(cè)圍墻外5m114°8′1.99255″,27°1′42.07862″監(jiān)測結(jié)果具體監(jiān)測結(jié)果見下表。表2-3電磁環(huán)境質(zhì)量現(xiàn)狀監(jiān)測統(tǒng)計結(jié)果單位:dB(A)檢測編號檢測點位置檢測項目檢測結(jié)果2021年05月04日D1沿線代表性點位①工頻電場(V/m)50工頻磁場(μT)0.4D2沿線代表性點位②工頻電場(V/m)105工頻磁場(μT)1.0D3里田鎮(zhèn)湯溪村光伏電站110kV升壓站出線間隔西北圍墻外5m工頻電場(V/m)227工頻磁場(μT)3.8D2(引用)里田變電站站界東北側(cè)圍墻外5m工頻電場(V/m)12.94工頻磁場(μT)0.2614注:標準限值依據(jù)《電磁環(huán)境控制限值》(GB8702-2014)中相應頻率范圍的限值要求(頻率50Hz,工頻電場4000V/m,工頻磁場100μT)?,F(xiàn)狀評價根據(jù)監(jiān)測結(jié)果,變電站出現(xiàn)間隔圍墻外及沿線代表性點位的工頻電場強度均滿足《電磁環(huán)境控制限值》(GB8702-2014)中相應頻率范圍的限值要求(頻率50Hz,工頻電場4000V/m,工頻磁場100μT)。綜上,評價區(qū)域內(nèi)電磁環(huán)境均能滿足《電磁環(huán)境控制限值》(GB8702-2014)中相應頻率范圍的限值要求。電磁環(huán)境影響評價工頻電磁場境影響預測3.1.1電纜線路電磁環(huán)境影響分析1)高壓交流架空輸電線路下空間工頻電場強度的計算方法=1\*GB3①單位長度導線下等效電荷的計算:高壓送電線上的等效電荷是線電荷,由于高壓送電線半徑r遠小于架設高度h,因此等效電荷的位置可以認為是在送電導線的幾何中心。假設送電線路為無限長并且平行于地面,地面可視為良導體,利用鏡像法計算送電線上的等效電荷。多導線線路中導線上的等效電荷由下列矩陣方程計算:式中:[Ui]——各導線對地電壓的單列矩陣;[Qi]——各導線上等效電荷的單列矩陣;[λij]——各導線的電位系數(shù)組成的n階方陣(n為導線數(shù)目)。[U]矩陣可由送電線的電壓和相位確定,從環(huán)境保護考慮以額定電壓的1.05倍(115.5kV)作為計算電壓;[λ]矩陣由鏡像原理求得。=2\*GB3②計算由等效電荷產(chǎn)生的電場:為計算地面電場強度的最大值,通常取夏天滿負荷有最大弧垂時導線的最小對地高度。因此,所計算的地面場強僅對檔距中央一段(該處場強最大)是符合的。當各導線單位長度的等效電荷量求出后,空間任意一點的電場強度可根據(jù)疊加原理計算得出,在(x,y)點的電場強度分量Ex和Ey可表示為:式中:xi、yi——導線i的坐標(i=1、2、…m);m——導線數(shù)目;Li、Li?——分別為導線i及鏡像至計算點的距離。則P點的總電場為:2)高壓交流架空輸電線路下空間工頻磁場強度的計算(附錄D)不考慮導線i的鏡像時,單相導線產(chǎn)生的磁感應強度按下式進行計算:QUOTE式中:I——導線I中的電流值;h——計算點距導線的垂直高度,m;L——計算點距導線的水平距離,m。本工程為三相輸電,考慮到空間某點的磁場是由三相電流分別產(chǎn)生,所產(chǎn)生的三個矢量除大小和方向不同外,三個矢量間相角還相差120?,合成后是一旋轉(zhuǎn)矢量。旋轉(zhuǎn)矢量的軌跡為一橢圓,一般可用橢圓的長軸來表示綜合磁感應強度的最大值。3)計算參數(shù)的選取本工程送電線路為單塔單回架設,按單回路進行預測,本次評價選擇典型塔型(1A3-ZM2),根據(jù)設計規(guī)范經(jīng)過居民區(qū)和非居民區(qū)時導線對地最低高度為7m和6m。預測電壓為標稱電壓110kV的1.05倍,即115.5kV。單回輸電線路電磁理論預測計算參數(shù)見下表,預測選取的典型塔型如下。表3-1本工程輸電線路電磁理論計算基礎參數(shù)項目單回路塔型1A3-ZM2導線型式JL/G1A-300/40分裂數(shù)1根導線直徑23.9mm地線型式采用OPGW復合光纜(Φ=13.2mm)計算輸送功率(MW)單回輸送功率120MW(按環(huán)保最不利原則,采用可研提供的最大輸送功率,即線路長期允許輸送容量)預測電壓(kV)115.5長期運行載流量656A底導線對地距離6m(最大弧垂經(jīng)過非居民區(qū)的最低設計高度)7m(最大弧垂經(jīng)過居民區(qū)的最低設計高度)計算原點O(0,0)桿塔中心計算距離0~50m掛線方式和相序線高7m6m坐標x1(m)y1(m)x2(m)y2(m)地線1-2.512.95-2.511.95地線22.512.952.511.95第1號導線(A相)011.05010.05第2號導線(B相)-3.157-3.156第3號導線(C相)3.1573.156工頻電場強度要計算的區(qū)域參數(shù)要測試離地面分別是:1.5米、4.5米、7.5米、10.5米高處的電場強度;水平坐標范圍為從-50米到50米要測試離地面分別是:1.5米高處的電場強度;水平坐標范圍為從-50米到50米工頻磁感應強度要計算的區(qū)域參數(shù)要測試離地面分別是:1.5米、4.5米、7.5米、10.5米高處的磁場強度;水平坐標范圍為從-50米到50米;要測試離地面分別是:1.5米高處的電場強度;水平坐標范圍為從-50米到50米注:7m和6m分別為設計規(guī)程要求的線路經(jīng)過居民區(qū)和非居民區(qū)時導線對地的最小距離,導線對地距離均應大于上述值,環(huán)評以最不利條件計算線路工頻電磁場對環(huán)境的影響。計算塔型選型原則:本理論計算塔型選擇以單回直線塔型出現(xiàn)頻率較大且對環(huán)境影響最大的塔型來作為理論計算塔型。4)計算結(jié)果=1\*GB3①本工程輸電線路工頻電場強度貢獻值預測結(jié)果如下表3-2及圖3-1、3-2所示。表3-2本工程輸電線路工頻電場強度貢獻值預測結(jié)果距離地面的垂直高度(m)距原點水平投影間距(m)對地線高7m對地線高6m1.5米高處電場的綜合量(kV/m)4.5米高處電場的綜合量(kV/m)7.5米高處電場的綜合量(kV/m)10.5米高處電場的綜合量(kV/m)1.5米高處電場的綜合量(kV/m)距原點-50米0.0160.0160.0160.0160.016距原點-49米0.0170.0170.0170.0160.017距原點-48米0.0180.0180.0170.0170.017距原點-47米0.0190.0190.0180.0180.018距原點-46米0.0200.0200.0190.0190.019距原點-45米0.0210.0210.0200.0200.020距原點-44米0.0220.0220.0210.0210.021距原點-43米0.0230.0230.0230.0220.022距原點-42米0.0250.0240.0240.0230.024距原點-41米0.0260.0260.0250.0250.025距原點-40米0.0280.0280.0270.0260.026距原點-39米0.0300.0290.0290.0280.028距原點-38米0.0320.0310.0310.0300.030距原點-37米0.0340.0330.0330.0320.032距原點-36米0.0360.0360.0350.0340.034距原點-35米0.0390.0380.0370.0360.037距原點-34米0.0420.0410.0400.0390.039距原點-33米0.0450.0450.0430.0420.042距原點-32米0.0490.0480.0470.0450.046距原點-31米0.0530.0520.0510.0480.049距原點-30米0.0580.0570.0550.0520.054距原點-29米0.0630.0620.0600.0570.058距原點-28米0.0690.0680.0650.0620.064距原點-27米0.0770.0750.0720.0680.070距原點-26米0.0850.0830.0790.0740.077距原點-25米0.0940.0920.0870.0810.086距原點-24米0.1050.1020.0970.0900.096距原點-23米0.1170.1140.1080.1000.107距原點-22米0.1320.1280.1210.1110.121距原點-21米0.1500.1450.1360.1240.137距原點-20米0.1700.1650.1540.1390.156距原點-19米0.1950.1880.1750.1570.179距原點-18米0.2250.2170.2010.1780.207距原點-17米0.2600.2510.2320.2040.241距原點-16米0.3040.2930.2690.2340.284距原點-15米0.3570.3440.3150.2720.337距原點-14米0.4220.4080.3730.3170.402距原點-13米0.5010.4880.4460.3760.485距原點-12米0.5980.5890.5400.4460.590距原點-11米0.7170.7180.6640.5370.724距原點-10米0.8600.8850.8320.6570.892距原點-9米1.0291.1051.0670.8161.103距原點-8米1.2221.3981.4151.0321.360距原點-7米1.4281.7941.9631.3311.660距原點-6米1.6252.3302.9251.7501.979距原點-5米1.7763.0214.9342.3392.261距原點-4米1.8353.75110.7873.1632.419距原點-3米1.7714.14423.1204.3722.366距原點-2米1.5963.97111.0706.4362.103距原點-1米1.3953.5997.47511.3601.766距原點0米1.3023.4336.64923.1471.603距原點1米1.3953.5997.47511.3601.766距原點2米1.5963.97111.0706.4362103距原點3米1.7714.14423.1204.3722.366距原點4米1.8353.75110.7873.1632.419距原點5米1.7763.0214.9342.3392.261距原點6米1.6252.3302.9251.7501.979距原點7米1.4281.7941.9631.3311.660距原點8米1.2221.3981.4151.0321.360距原點9米1.0291.1051.0670.8161.103距原點10米0.8600.8850.8320.6570.892距原點11米0.7170.7180.6640.5370.724距原點12米0.5980.5890.5400.4460.590距原點13米0.5010.4880.4460.3740.485距原點14米0.4220.4080.3730.3170.402距原點15米0.3570.3440.3150.2720.337距原點16米0.3040.2930.2690.2340.284距原點17米0.2600.2510.2320.2040.241距原點18米0.2250.2170.2010.1780.207距原點19米0.1950.1880.1750.1570.179距原點20米0.1700.1650.1540.1390.156距原點21米0.1500.1450.1360.1240.137距原點22米0.1320.1280.1210.1110.121距原點23米0.1170.1140.1080.1000.107距原點24米0.1050.1020.0970.0900.096距原點25米0.0940.0920.0870.0810.086距原點26米0.0850.0830.0790.0740.077距原點27米0.0770.0750.0720.0680.070距原點28米0.0690.0680.0650.0620.064距原點29米0.0630.0620.0600.0570.058距原點30米0.0580.0570.0550.0520.054距原點31米0.0530.0520.0510.0480.049距原點32米0.0490.0480.0470.0450.046距原點33米0.0450.0450.0430.0420.042距原點34米0.0420.0410.0400.0390.039距原點35米0.0390.0380.0370.0360.035距原點36米0.0360.0360.0350.0340.034距原點37米0.0340.0330.0330.0320.032距原點38米0.0320.0310.0310.0300.030距原點39米0.0300.0290.0290.0280.028距原點40米0.0280.0280.0270.0260.026距原點41米0.0260.0260.0250.0250.025距原點42米0.0250.0240.0240.0230.024距原點43米0.0230.0230.0230.0220.022距原點44米0.0220.0220.0210.0210.021距原點45米0.0210.0210.0200.0200.020距原點46米0.0200.0200.0190.0190.019距原點47米0.0190.0190.0180.0180.018距原點48米0.0180.0180.0170.0170.017距原點49米0.0170.0170.0170.0160.017距原點50米0.0160.0160.0160.0160.016圖3-1本工程輸電線路對地線高7m工頻電場強度總體分布情況圖3-2本工程輸電線路對地線高6m工頻電場強度1.5米高處的電場分布情況=2\*GB3②本工程輸電線路工頻磁感應強度貢獻值預測結(jié)果如下表3-3及圖3-3、3-4所示。表3-3本工程輸電線路工頻磁感應強度貢獻值預測結(jié)果對地線高度(m)與計算原點的距離(m)對地線高7m對地線高6m1.5米高處磁場綜合量(微特)4.5米高處磁場綜合量(微特)7.5米高處磁場綜合量(微特)10.5米高處磁場綜合量(微特)1.5米高處磁場綜合量(微特)距原點-50米4.6284.6664.6894.6874.643距原點-49米4.7234.7644.7874.7864.739距原點-48米4.8234.8664.8904.8884.839距原點-47米4.9264.9724.9984.9964.943距原點-46米5.0345.0825.1105.1085.052距原點-45米5.1475.1985.2275.2255.166距原點-44米5.2645.3195.3505.3485.285距原點-43米5.3885.4465.4795.4765.410距原點-42米5.5175.5795.6145.6115.541距原點-41米5.6525.7195.7575.7535.678距原點-40米5.7945.8665.9065.9025.822距原點-39米5.9436.0206.0646.0595.973距原點-38米6.1006.1836.2306.2256.132距原點-37米6.2666.3556.4056.4006.300距原點-36米6.4406.5376.5916.5856.477距原點-35米6.6256.7296.7886.7816.665距原點-34米6.8196.9336.9966.9896.863距原點-33米7.0267.1507.2197.2107.073距原點-32米7.2457.3807.4557.4467.297距原點-31米7.4787.6267.7087.6977.535距原點-30米7.7267.8897.9797.9667.788距原點-29米7.9908.1708.2698.2548.059距原點-28米8.2738.4728.5818.5648.349距原點-27米8.5768.7968.9178.8988.660距原點-26米8.9019.1479.2819.2598.995距原點-25米9.2509.5269.6779.6509.356距原點-24米9.6289.93810.10710.0759.746距原點-23米10.03610.38610.57710.53910.170距原點-22米10.47810.87711.09411.04710.631距原點-21米10.96011.41611.66311.60611.134距原點-20米11.48612.01012.29512.22511.685距原點-19米12.06112.66912.99912.91112.292距原點-18米12.69313.40413.78813.67812.962距原點-17米13.39014.22814.68114.53913.706距原點-16米14.16215.15915.69715.51314.537距原點-15米15.01916.21916.86716.62315.468距原點-14米15.97417.43718.22617.89616.517距原點-13米17.04318.85219.82819.37017.708距原點-12米18.24020.51421.74521.09219.066距原點-11米19.58222.49624.08223.12320.623距原點-10米21.08324.89927.00425.53722.412距原點-9米22.74627.86830.77428.42824.468距原點-8米24.55531.61435.85731.89026.808距原點-7米26.45636.43443.16635.98429.408距原點-6米28.32742.65654.79940.62432.137距原點-5米29.96450.26076.91645.35834.680距原點-4米31.10457.496136.08549.31536.519距原點-3米31.52359.672231.84252.60637.125距原點-2米31.16354.72891.97361.47636.358距原點-1米30.16947.37458.705101.98834.597距原點0米28.79041.27051.432225.02532.407距原點1米27.24836.79548.235120.11030.182距原點2米25.68533.36944.24072.26328.090距原點3米24.16830.52239.60552.65826.166距原點4米22.72628.02035.13041.91624.400距原點5米21.36925.77631.19635.02522.775距原點6米20.09823.75827.86730.17321.282距原點7米18.91621.94925.08126.54619.912距原點8米17.82020.33622.74823.72018.659距原點9米16.80818.89920.78021.45017.516距原點10米15.87617.62119.10719.58316.474距原點11米15.01916.48217.67218.01915.527距原點12米14.23215.46516.43016.68914.665距原點13米13.50914.55515.34615.54313.879距原點14米12.84513.73714.39214.54613.163距原點15米12.23412.99913.54813.66912.509距原點16米11.67212.33212.79612.89311.911距原點17米11.15411.72612.12112.20011.362距原點18米10.67511.17411.51411.57810.857距原點19米10.23210.67010.96311.01610.393距原點20米9.82110.20710.46310.5079.963距原點21米9.4409.78110.00510.0429.566距原點22米9.0859.3899.5869.6179.198距原點23米8.7549.0259.2009.2278.855距原點24米8.4458.6888.8448.8678.536距原點25米8.1568.3758.5148.5348.238距原點26米7.8868.0838.2088.2257.959距原點27米7.6317.8107.9237.9387.698距原點28米7.3937.5557.6577.6707.453距原點29米7.1677.3167.4087.4207.223距原點30米6.9557.0917.1757.1857.006距原點31米6.7556.8796.9566.9656.801距原點32米6.5656.6796.7506.7586.608距原點33米6.3866.4916.5566.5636.425距原點34米6.2156.3126.3726.3796.252距原點35米6.0546.1446.1996.2056.088距原點36米5.9005.9836.0356.0405.932距原點37米5.7545.8315.8795.8845.783距原點38米5.6155.6875.7315.7355.642距原點39米5.4825.5495.5905.5945.507距原點40米5.3555.4185.4565.4605.379距原點41米5.2345.2925.3285.3325.256距原點42米5.1185.1735.2075.2105.139距原點43米5.0075.0585.0905.0935.026距原點44米4.9004.9494.9794.9814.919距原點45米4.7984.8444.8724.8754.816距原點46米4.7004.7444.7704.7724.717距原點47米4.6064.6474.6724.6744.622距原點48米4.5164.5554.5784.5804.531距原點49米4.4294.4664.4884.4904.443距原點50米4.3454.3804.4014.4034.358圖3-3本工程輸電線路對地線高7m工頻磁感應強度綜合量的分布情況圖3-4本工程輸電線路對地線高6m工頻磁感應強度1.5米高處的綜合量的分布情況5)計算分析由上表可知,110KV單回路工程在1A3-ZM2塔型掛線時,導線對地線高7m時,離地面1.5m高處工頻電場強度為0.016~1.835kV/m,工頻磁場強度為4.628~31.523μT;導線對地線高6m時,離地面1.5m高處工頻電場強度為0.016~2.419kV/m,工頻磁場強度為4.643~37.125μT;根據(jù)理論計算數(shù)據(jù)可知,經(jīng)過居民區(qū)和非居民區(qū)時,工頻電場強度和工頻磁場強度能夠滿足《電磁環(huán)境控制限值》(GB8702-2014)中標準限值。根據(jù)以上理論計算數(shù)據(jù)類推可知:本工程110kV單回線路經(jīng)過居民區(qū)時,1.5m高度處的工頻電場強度和工頻磁場強度數(shù)據(jù)均能滿足《電磁環(huán)境控制限值》(GB8072-2014)中公眾曝露控制限值即工頻電場強度控制限值4000V/m,磁感應強度控制限值0.1mT的要求;工程110kV單回線路經(jīng)過非居民區(qū)時,1.5m高度處的工頻電場強度和工頻磁場強度數(shù)據(jù)均能滿足《電磁環(huán)境控制限值》(GB8072-2014)中輸電線路線下的耕地、園地、牧草地、畜禽飼養(yǎng)地、養(yǎng)殖水面、道路等場所,其頻率50Hz的電場強度控制限值為10kV/m,磁感應強度控制限值0.1mT的要求。3.1.2電纜線路電磁環(huán)境影響分析本工程新建單回電纜線路長度約0.15km,本電纜線路工程以高家墩-石嶺110kV電纜線路作類比對象進行電纜敷設線路電磁場環(huán)境影響預測與評價。類比對象選擇輸電線路類比可比性見表3-4。表3-4電纜線路類比可比性名稱本工程電纜110kV高家墩-石嶺線電壓等級110kV110kV導線型號ZC-YJLW03-Z-110kV-1×630ZC-YJLW02-Z-64/110-1×630鋪設方式電纜溝電纜溝電纜距地面高度1m1m回數(shù)單回單回類比測量時間為2017年12月26日,天氣晴,溫度4-15℃,相對濕度53%,氣壓100.8kPa,監(jiān)測單位江西省核工業(yè)地質(zhì)局測試研究中心。類比監(jiān)測見附件7。類比監(jiān)測結(jié)果如下。表3-5110kV高家墩-石嶺線工頻電場、磁感應強度監(jiān)測結(jié)果序號測點位置工頻電場強度(V/m)工頻磁感應強度(μT)1管廊上方0m3.540.0282管廊西側(cè)1m2.910.0273管廊西側(cè)2m1.850.0254管廊西側(cè)3m2.140.0315管廊西側(cè)4m1.420.0356管廊西側(cè)5m1.140.028依據(jù)上表的監(jiān)測數(shù)據(jù),高家墩-石嶺110kV電纜線路電纜溝外(0~5m)工頻電場為1.14~3.54V/m,工頻磁場為0.025~0.035μT,該類比數(shù)據(jù)均遠低于《電磁環(huán)境控制限值》(GB8702-2014)中工頻電場強度控制限值4000V/m,工頻磁感應強度控制限值100μT的要求。所以本電纜線路工程鋪設
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經(jīng)權益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
- 6. 下載文件中如有侵權或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025年度可再生能源發(fā)電項目承包合同范本
- 2025年度樣板房裝修施工及售后服務合同
- 給開發(fā)商的申請書
- 2025年度攪拌機租賃與智能化生產(chǎn)線合同
- 2025年度借款合同撤銷與廢止中的稅務處理及風險防控
- 2025年度醫(yī)療健康數(shù)據(jù)實習生保密及患者隱私保護合同
- 關于車位合同范本
- 宿管部入部申請書
- 2025年度企業(yè)信息保密與員工保密責任合同范本
- 2025年度國際貿(mào)易風險管理咨詢服務合同范本
- 商業(yè)銀行的風險審計與內(nèi)部控制
- 2024項目管理人員安全培訓考試題及參考答案AB卷
- 2025年與商場合作協(xié)議樣本(5篇)
- 2024年12月青少年機器人技術等級考試理論綜合試卷(真題及答案)
- 網(wǎng)絡與社交媒體管理制度
- 2025年春新外研版(三起)英語三年級下冊課件 Unit1第1課時Startup
- 2025年安徽碳鑫科技有限公司招聘筆試參考題庫含答案解析
- 數(shù)學-福建省泉州市2024-2025學年高三上學期質(zhì)量監(jiān)測(二)試卷和答案(泉州二模)
- 2025年寒假實踐特色作業(yè)設計模板
- 2024年福建漳州人才發(fā)展集團有限公司招聘筆試參考題庫附帶答案詳解
- JTGT F20-2015 公路路面基層施工技術細則
評論
0/150
提交評論