文檔簡介
第六章燃?xì)夤芫W(wǎng)水力計(jì)算第一節(jié)燃?xì)夤芫W(wǎng)設(shè)計(jì)計(jì)算第二節(jié)室內(nèi)燃?xì)夤艿涝O(shè)計(jì)計(jì)算燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第1頁第一節(jié)燃?xì)夤芫W(wǎng)設(shè)計(jì)計(jì)算燃?xì)夤艿浪τ?jì)算任務(wù):一是依據(jù)計(jì)算流量和要求壓力損失來計(jì)算管徑,進(jìn)而決定管道投資與金屬消耗;二是對已經(jīng)有管道進(jìn)行流量和壓力損失驗(yàn)算,以充分發(fā)揮管道輸氣能力,或決定是否需要對原有管道進(jìn)行改造。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第2頁第一節(jié)燃?xì)夤芫W(wǎng)設(shè)計(jì)計(jì)算一、燃?xì)馑τ?jì)算公式二、燃?xì)夥峙涔芏斡?jì)算流量確實(shí)定三、管網(wǎng)計(jì)算燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第3頁一、燃?xì)馑τ?jì)算公式(一)燃?xì)庠趫A管中穩(wěn)定流動方程式(二)附加壓頭與局部阻力損失燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第4頁(一)燃?xì)庠趫A管中穩(wěn)定流動方程式?jīng)Q定燃?xì)饬鲃忧闆r參數(shù)為:壓力P、密度ρ和流速ω。為了求得P、ρ和ω必須有三個獨(dú)立方程,對于穩(wěn)定流動燃?xì)夤艿溃衫貌环€(wěn)定流動方程、連續(xù)性方程及氣體狀態(tài)方程組成以下方程組:燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第5頁由此為基準(zhǔn)可推導(dǎo)出高壓、次高壓和中壓燃?xì)夤艿绬挝婚L度摩擦阻力損失表示式:(一)燃?xì)庠趫A管中穩(wěn)定流動方程式燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第6頁(一)燃?xì)庠趫A管中穩(wěn)定流動方程式考慮到實(shí)際情況,我國當(dāng)前工程上普通采取由上述公式制成水力計(jì)算表,見附錄2。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第7頁(二)附加壓頭與局部阻力損失(1)附加壓頭:因?yàn)槿細(xì)饷芏扰c空氣密度不一樣,當(dāng)燃?xì)夤艿朗寄┒舜嬖诟叱滩顣r,管道中特產(chǎn)生附加壓頭(或附加阻力)、附加壓頭值由下式確定:燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第8頁(二)附加壓頭與局部阻力損失(2)局部阻力:可用下式求得:燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第9頁(二)附加壓頭與局部阻力損失在進(jìn)行燃?xì)夥峙涔芫W(wǎng)水力計(jì)算時,普通不詳細(xì)計(jì)算局部阻力,而按增加燃?xì)夤芏伍L度5%-10%作為計(jì)算長度進(jìn)行計(jì)算。對于街坊內(nèi)庭院管道和室內(nèi)管道局部阻力應(yīng)逐一進(jìn)行計(jì)算,廠區(qū)內(nèi)燃?xì)夤艿涝谒τ?jì)算時也要計(jì)算局部阻力。也能夠?qū)⒕植孔枇φ鬯愠上嗤軓焦芏萎?dāng)量長度L2計(jì)算。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第10頁(二)附加壓頭與局部阻力損失燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第11頁(二)附加壓頭與局部阻力損失燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第12頁二、燃?xì)夥峙涔芏斡?jì)算流量確實(shí)定(一)燃?xì)夥峙涔芫W(wǎng)供氣方式(二)燃?xì)夥峙涔芏瓮拘沽髁看_實(shí)定(三)燃?xì)夥峙涔芏斡?jì)算流量確定(四)節(jié)點(diǎn)流量燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第13頁(一)燃?xì)夥峙涔芫W(wǎng)供氣方式燃?xì)夥峙涔芫W(wǎng)各管段依據(jù)連接用戶情況,可分為三種:(1)管段沿途不輸出燃?xì)?,這種管段燃?xì)饬髁渴遣蛔?。Q2稱為轉(zhuǎn)輸流量。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第14頁(一)燃?xì)夥峙涔芫W(wǎng)供氣方式(2)分配管網(wǎng)管段與大量居民用戶、小型商業(yè)用戶相連。由管段始端進(jìn)入燃?xì)庠谕局腥抗┙o各個用戶。Q1稱為途泄流量。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第15頁(一)燃?xì)夥峙涔芫W(wǎng)供氣方式(3)最常見分配管段供氣情況。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第16頁(二)燃?xì)夥峙涔芏瓮拘沽髁看_實(shí)定在城鎮(zhèn)燃?xì)夤芫W(wǎng)計(jì)算中能夠認(rèn)為,途泄流量是沿管段均勻輸出。管段單位長度途泄流量為:燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第17頁管段途泄流量計(jì)算燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第18頁計(jì)算管段途泄流量1-2管段1-6管段燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第19頁(三)燃?xì)夥峙涔芏斡?jì)算流量確定管段上現(xiàn)有途泄流量又有轉(zhuǎn)輸流量變負(fù)荷管段,其計(jì)算流量可按下式求得:燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第20頁(四)節(jié)點(diǎn)流量
在燃?xì)夤芫W(wǎng)計(jì)算時,尤其是在用計(jì)算機(jī)進(jìn)行燃?xì)猸h(huán)網(wǎng)水力計(jì)算時,常把途泄流量改用節(jié)點(diǎn)流量來表示。從式6-13可知,途泄流量Q1可分為兩個部分:一部分0.55Q1是從管段終端流出,另一部分0.45Q1是在始端流出。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第21頁
因?yàn)榄h(huán)狀管網(wǎng)各管段相互連接,故各節(jié)點(diǎn)流量等于流入節(jié)點(diǎn)全部管段途泄流量0.55Q1、流出節(jié)點(diǎn)全部管段途泄流量0.45Q1,以及與該節(jié)點(diǎn)集中流量三者之和。(四)節(jié)點(diǎn)流量燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第22頁(四)節(jié)點(diǎn)流量燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第23頁三、管網(wǎng)計(jì)算(一)枝狀管網(wǎng)水力計(jì)算(二)環(huán)狀管網(wǎng)水力計(jì)算(1)環(huán)狀管網(wǎng)計(jì)算特點(diǎn)(2)環(huán)狀管網(wǎng)計(jì)算步驟燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第24頁(一)枝狀管網(wǎng)水力計(jì)算(1)對管網(wǎng)節(jié)點(diǎn)和管段編號。(2)依據(jù)管線圖和用氣情況,確定管網(wǎng)各管段計(jì)算流量。(3)依據(jù)給定允許壓力降及因?yàn)楦叱滩疃斐筛郊訅侯^,確定管線單位長度允許壓力降。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第25頁(一)枝狀管網(wǎng)水力計(jì)算(4)依據(jù)管段計(jì)算流量及單位長度允許壓力降選擇管徑。(5)依據(jù)所選定標(biāo)準(zhǔn)管徑,求沿程壓力降和局部壓力降,計(jì)算總壓力降。(6)檢驗(yàn)計(jì)算結(jié)果。若總壓力降未超出允許值,并趨近允許值,則認(rèn)為計(jì)算合格不然應(yīng)適當(dāng)變動管徑,直到總壓力降小于并盡可能趨近允許值為止。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第26頁(1)環(huán)狀管網(wǎng)計(jì)算特點(diǎn)(2)環(huán)狀管網(wǎng)計(jì)算步驟(二)環(huán)狀管網(wǎng)水力計(jì)算燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第27頁(1)環(huán)狀管網(wǎng)計(jì)算特點(diǎn)燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第28頁(2)環(huán)狀管網(wǎng)計(jì)算步驟1)繪制管網(wǎng)平面示意圖,管網(wǎng)布置應(yīng)使管道負(fù)荷較為均勻。然后對節(jié)點(diǎn)、環(huán)網(wǎng)、管段進(jìn)行編號,標(biāo)明管道長度、燃?xì)庳?fù)荷、氣源或調(diào)用站位置等。2)計(jì)算各管段途泄流量。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第29頁環(huán)狀管網(wǎng)計(jì)算步驟3)按氣流沿著最短路徑從供氣點(diǎn)流向零點(diǎn)(零點(diǎn)是指各環(huán)中燃?xì)庋仨槙r針流動與逆時針流動交匯點(diǎn),此點(diǎn)為各環(huán)壓力最低點(diǎn))標(biāo)準(zhǔn),確定環(huán)狀管網(wǎng)燃?xì)饬鲃臃较?。但在同一環(huán)內(nèi),必須有兩個相反流向。4)依據(jù)確定氣流方向,以∑Qi=0為條件,從零點(diǎn)開始,設(shè)定流量分配,逐一推算每一根管道初步計(jì)算流量。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第30頁環(huán)狀管網(wǎng)計(jì)算步驟5)依據(jù)管網(wǎng)允許壓力降和供氣點(diǎn)至零點(diǎn)管道計(jì)算長度(局部阻力通常取沿程損失5%-10%),求得單位長度允許壓力降,依據(jù)流量和單位長度允許壓力降查附圖即可選擇管徑。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第31頁環(huán)狀管網(wǎng)計(jì)算步驟6)由選定管徑,計(jì)算各管道實(shí)際壓力降以及每環(huán)閉合差,通常初步計(jì)算結(jié)果管網(wǎng)各環(huán)壓力降是不閉合(手工計(jì)算閉合差超出10%,電算閉合差超出5%),這就必須進(jìn)行環(huán)網(wǎng)水力平差計(jì)算。7)在人工計(jì)算中,平差計(jì)算是逐次進(jìn)行流量校正,使環(huán)網(wǎng)閉合差漸趨工程允許誤差范圍過程。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第32頁環(huán)狀管網(wǎng)計(jì)算步驟8)由管段壓力降推算管網(wǎng)各節(jié)點(diǎn)壓力。一旦節(jié)點(diǎn)壓力未滿足要求,或者管道壓降過小而不夠經(jīng)濟(jì)時,還需調(diào)整管徑,重新進(jìn)行前述6)、7)兩步計(jì)算。9)繪制水力計(jì)算簡圖,圖中標(biāo)明管段長度、管徑、計(jì)算流量、壓力降和節(jié)點(diǎn)流量、壓力等。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第33頁水力平差計(jì)算低壓管網(wǎng)燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第34頁高、次高、中壓管網(wǎng)水力平差計(jì)算燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第35頁水力平差計(jì)算首先計(jì)算各環(huán),進(jìn)而才能求出考慮鄰環(huán)影響,令,以此校正每環(huán)各根管段計(jì)算流量。若校正后閉合差仍未到達(dá)精度要求,則需再一次計(jì)算校正流量,及,再作流量校正、使之逐次迫近并到達(dá)允許精度要求為止。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第36頁水力平差計(jì)算壓力閉合差精度要求高、次高、中壓管網(wǎng)低壓管網(wǎng)燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第37頁例題[6-1]燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第38頁例題解析1、計(jì)算各環(huán)單位長度途泄流量,為此(1)按管網(wǎng)布置將供氣區(qū)域分為三個小區(qū);(2)求出各環(huán)內(nèi)最大小時用氣量∴燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第39頁(3)計(jì)算供氣環(huán)周圍總長燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第40頁(4)求單位長度途泄流量∴燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第41頁2、依據(jù)計(jì)算簡圖,求出管網(wǎng)中每一管段計(jì)算流量,列表于6-3。(1)將管網(wǎng)各管段依次編號,在距供氣點(diǎn)(調(diào)壓站)最遠(yuǎn)處,假定零點(diǎn)位置(3,5,8),同時決定氣流方向。(2)計(jì)算各管段途泄流量:對于Ⅰ環(huán):1-22-31-44-3燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第42頁同理,對于Ⅱ環(huán):對于Ⅲ環(huán):燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第43頁(3)計(jì)算轉(zhuǎn)輸流量燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第44頁(3)計(jì)算轉(zhuǎn)輸流量燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第45頁(3)計(jì)算轉(zhuǎn)輸流量燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第46頁(4)求計(jì)算流量對于Ⅰ環(huán):燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第47頁(4)求計(jì)算流量對于Ⅱ環(huán):燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第48頁(4)求計(jì)算流量對于Ⅲ環(huán):燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第49頁校驗(yàn)轉(zhuǎn)輸流量總值調(diào)壓站由1-2,1-4,1-6管段輸出燃?xì)饬繛椋簝芍迪喾8鳝h(huán)供氣量及集中負(fù)荷為:燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第50頁3、依據(jù)初步流量分配及單位長度平均壓力降選擇各管段管徑。局部阻力選沿程阻力10%。先預(yù)定單位長度計(jì)算壓降,由供氣點(diǎn)到零點(diǎn)平均距離為:單位長度計(jì)算壓降為,
燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第51頁∵本題中而在查附圖時
則需要修正
由Q,查附錄2附圖1,可選定管徑,依據(jù)所選定管徑再查值,再依據(jù)求燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第52頁順時針方向:249+120=369逆時針方向:306+30=336則閉合差值為369-336=33(33/369+33/336)/2=9.3%燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第53頁4、校核計(jì)算從表初步計(jì)算可見,兩個環(huán)閉合差均大于10%,一個環(huán)閉合差小于10%,應(yīng)該對全部環(huán)網(wǎng)進(jìn)行校核計(jì)算,不然因?yàn)猷彮h(huán)校正流量值影響,反而會使該環(huán)閉合差增大,有超出10%可能。所以,先求各環(huán),再求各環(huán)燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第54頁燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第55頁各環(huán)校正流量為共用管段校正流量=本環(huán)校正流量-鄰環(huán)校正流量如1-2,為Ⅰ與Ⅲ共用管段,對于Ⅰ環(huán):1-2,其校正流量為-5.5-(-11.0)=+5.5。對于Ⅲ環(huán):1-2,其校正流量為-11.0-(-5.5)=-5.5燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第56頁經(jīng)過計(jì)算,各環(huán)誤差值均在10%以內(nèi),所以計(jì)算合格。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第57頁5、經(jīng)過校正流量計(jì)算,使管網(wǎng)中燃?xì)饬髁窟M(jìn)行重新分配因而集中負(fù)荷預(yù)分配量有所調(diào)整,并使零點(diǎn)位置有了移動。點(diǎn)3工廠集中負(fù)荷由4-3管段供氣50+5.5=55.5m3/h,由2-3管段供氣50-5.5=45.5m3/h。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第58頁管段6-5計(jì)算流量由119m3/h減至103.9m3/h,因而零點(diǎn)向6方向移動了△L6。管段7-8計(jì)算流量由62m3/h減至51m3/h,因而零點(diǎn)向點(diǎn)7方向移動了新零點(diǎn)位置用記號“x”表示在圖6-6上,這些點(diǎn)是環(huán)網(wǎng)在計(jì)算工況下壓力最低。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第59頁6、校核從供氣點(diǎn)至零點(diǎn)壓力降此壓力降充分利用了計(jì)算壓力降數(shù)值,說明了計(jì)算到達(dá)了經(jīng)濟(jì)合理效果。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第60頁第二節(jié)室內(nèi)燃?xì)夤艿涝O(shè)計(jì)計(jì)算一、室內(nèi)燃?xì)夤艿兰叭季卟贾枚?、室?nèi)燃?xì)夤艿涝O(shè)計(jì)計(jì)算燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第61頁一、室內(nèi)燃?xì)夤艿兰叭季卟贾?一)燃?xì)庥脩粢牍?二)室內(nèi)燃?xì)夤艿?三)燃?xì)庥?jì)量表布置(四)家庭炊事燃具布置(五)家用熱水器布置燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第62頁(一)燃?xì)庥脩粢牍?/p>
燃?xì)庥脩粢牍芤喾Q進(jìn)戶管,普通從家庭廚房、樓梯間或走廊等便于修理非居住房間處引入,不應(yīng)從臥室、浴室,易燃或易爆品倉庫、有腐蝕介質(zhì)房間、配電間、變電室、電纜溝、煙道和進(jìn)風(fēng)道等處引入。進(jìn)戶方式有地下引入和地上引入兩種。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第63頁(二)室內(nèi)燃?xì)夤艿朗覂?nèi)燃?xì)夤艿啦粦?yīng)敷設(shè)在易燃易爆場所或倉庫、配電間、變電室、電線溝、煙道和進(jìn)風(fēng)道等處。當(dāng)必須敷設(shè)在潮濕或有腐蝕介質(zhì)場所時,必須采取尤其防腐辦法。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第64頁(二)室內(nèi)燃?xì)夤艿栏邔咏ㄖ?nèi)燃?xì)夤艿缿?yīng)設(shè)置自動切斷閥門、泄漏警報(bào)器和送排風(fēng)系統(tǒng)等自動切斷連鎖裝置。25層以上建筑宜設(shè)燃?xì)庑孤┘斜O(jiān)視裝置和壓力控制裝置等用氣安全設(shè)施。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第65頁(二)室內(nèi)燃?xì)夤艿缹τ诟邔咏ㄖ覂?nèi)燃?xì)夤艿老到y(tǒng)還應(yīng)考慮三個特殊問題。(1)賠償高層建筑沉降。(2)克服高程差引發(fā)附加壓頭影響。(3)賠償溫差產(chǎn)生變形。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第66頁(三)燃?xì)庥?jì)量表布置(1)燃?xì)獗硪嗽O(shè)置在通風(fēng)良好非燃結(jié)構(gòu)上,并滿足便于施工、維修、調(diào)試和安全使用要求。(2)居民住宅內(nèi)燃?xì)獗硪嗣髟O(shè),高鎖表時,表底距地面大于1.4m,表側(cè)面與燃?xì)庠顑艟啻笥?0cm,表后面距墻面大于1cm;采取低鎖表時,表底距地面大于5cm。(3)工業(yè)和商業(yè)用戶用氣計(jì)量裝置宜集中布置在單獨(dú)房間內(nèi),當(dāng)設(shè)有調(diào)壓站時可與調(diào)壓器同室布置。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第67頁(四)家庭炊事燃具布置(1)燃?xì)庠顟?yīng)安裝在通風(fēng)良好廚房內(nèi),禁止設(shè)置在臥室內(nèi),利用套間或走廊作廚房時應(yīng)設(shè)門與臥室隔開。(2)燃?xì)庠羁繅υO(shè)置,與墻凈距不宜小于1cm,與對面墻之間應(yīng)有大于1m通道,灶邊與側(cè)墻凈距大于15cm。(3)燃?xì)鉄崴魃戏讲粦?yīng)有明裝電線或電器設(shè)備。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第68頁(五)家用熱水器布置(1)燃?xì)鉄崴鲬?yīng)含有強(qiáng)制排風(fēng),自動熄火保護(hù)及防倒風(fēng)裝置。(2)熱水器應(yīng)安裝在通風(fēng)良好房間或過道內(nèi),不得安裝在臥室、浴室、廁所和室外。(3)熱水器與對面墻壁之間應(yīng)有大于1m通道,側(cè)面離墻距離應(yīng)大干10cm。(4)設(shè)置熱水器房間凈高度應(yīng)大于2.4m。(5)熱水器與燃?xì)獗?、灶及電器設(shè)備水平凈距不應(yīng)小于30cm,其上部不應(yīng)有電力明線、電器設(shè)備和易燃物。燃?xì)夤こ倘細(xì)夤芫W(wǎng)水力計(jì)算專家講座第69頁二、室內(nèi)燃?xì)夤艿涝O(shè)計(jì)計(jì)算在室內(nèi)燃?xì)夤艿烙?jì)算之前,必須選定和布置用戶燃?xì)庥镁撸嫵龉艿老到y(tǒng)圖。居民用戶室內(nèi)燃?xì)夤艿烙?jì)算流量,應(yīng)按同時工作系數(shù)
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025-2030年中國隔振器市場供需現(xiàn)狀規(guī)劃分析報(bào)告
- 2025-2030年中國防脫發(fā)市場運(yùn)行狀況及前景趨勢分析報(bào)告
- 2025-2030年中國鎳鋅電池市場競爭格局及發(fā)展趨勢分析報(bào)告
- 2025-2030年中國車庫門市場運(yùn)營狀況及發(fā)展趨勢分析報(bào)告
- 2025-2030年中國貴金屬冶煉市場運(yùn)營狀況規(guī)劃分析報(bào)告
- 2025-2030年中國蜂膠市場運(yùn)行現(xiàn)狀及投資戰(zhàn)略研究報(bào)告
- 2025-2030年中國藥酒市場發(fā)展現(xiàn)狀與投資規(guī)劃研究報(bào)告
- 2025-2030年中國胡蘿卜素行業(yè)運(yùn)營狀況及投資前景預(yù)測報(bào)告
- 2025-2030年中國耐火型電纜產(chǎn)業(yè)十三五規(guī)劃及發(fā)展趨勢預(yù)測報(bào)告
- 2025-2030年中國緩降器產(chǎn)業(yè)前景預(yù)測及投資戰(zhàn)略研究報(bào)告
- 小學(xué)科學(xué)新課標(biāo)科學(xué)課程標(biāo)準(zhǔn)解讀
- 2024廣西公務(wù)員考試及答案(筆試、申論A、B類、行測)4套 真題
- 2024年山東省濟(jì)南市中考英語試題卷(含答案解析)
- 2022年版初中物理課程標(biāo)準(zhǔn)解讀-課件
- 語文七年級下字帖打印版
- 自然辯證法概論(新)
- 安全評價(jià)理論與方法第五章-事故樹分析評價(jià)法
- 幼兒園一日活動流程表
- 最后一分鐘安全檢查
- 散裝水泥罐體標(biāo)準(zhǔn)資料
- 原發(fā)性肝癌臨床路徑最新版
評論
0/150
提交評論