建筑環(huán)境與能源應用工程專業(yè)英語14.ppt_第1頁
建筑環(huán)境與能源應用工程專業(yè)英語14.ppt_第2頁
建筑環(huán)境與能源應用工程專業(yè)英語14.ppt_第3頁
建筑環(huán)境與能源應用工程專業(yè)英語14.ppt_第4頁
建筑環(huán)境與能源應用工程專業(yè)英語14.ppt_第5頁
已閱讀5頁,還剩24頁未讀 繼續(xù)免費閱讀

VIP免費下載

版權說明:本文檔由用戶提供并上傳,收益歸屬內容提供方,若內容存在侵權,請進行舉報或認領

文檔簡介

,Unit Fourteen Control and Building Automation System,What is an intelligent building?,Schematic Diagram of an Intelligent Building System,Up to now, there has not been a universally accepted definition for an Intelligent Building. Most existing definitions of IB around the world centre on the need for a building to be suitable for the occupants to work and live in safely, comfortably, effectively and efficiently. “Intelligent building is something that make stupid people feel not as stupid as they are”.,Intelligent Building can bring us Reduced Resource Consumption Both home and building technology offer tremendous potential savings through intelligent controls. Optimized Convenience and More Comfort Apart from minimizing consumption costs, private home owners will be interested in higher levels of convenience, safety and security.,Smart Home is an integration of various systems at home such as security, home automation, lighting control, CCTV and entertainment system which is coordinated by a smart home controller and controlled by users using various centralized command interfaces such as a touch screens, keypads, universal remote controllers, internet browser, telephone, and even your LCD TV screen.,Smart Home Systems,CCTV: Closed Circuit Television CCTV: China Central Television,On/off Control,The control device can be positioned only to a maximum or minimum state (e.g., on or off). Because On/off control is simple and inexpensive, it is used extensively for both industrial and commercial control. A typical home thermostat that starts and stops a furnace is an example of On/off action.,Floating Control,Dead (neutral) zone,盲區(qū) 停滯區(qū),In floating control, the controller can perform only two operations moving the controlled device toward either its open or closed position, usually at a constant rate. Generally, a neutral zone between the two positions allows the controlled device to stop at any position when the controlled variable is within the differential of the controller. When the controlled variable falls outside the differential of the controller, the controller moves the controlled device in the proper direction.,open,shut,Time,Upper limit,Lower limit,neutral zone,Temperature,Valve,set point,controlled variable,proportional band,output,offset,Proportional control requires a continuously variable output of the controlled device. The control system produces an output which is proportional to the error signal, i.e. the difference between the value of the controlled variable and the set point.,Proportional control,signal,response,Integral control,Derivative control,signal,response,Proportional plus Integral (PI) Control,Proportional-Integral-Derivative (PID) Control,Proportional Action.,Closed loop control,Feedback,A closed loop or feedback control measures actual changes in the controlled variable and actuates the controlled device to bring about a change. The corrective action continues until the variable is brought to a desired value within the design limitations of the controller. This arrangement of having the controller sense the value of the controlled variable is known as feedback.,Example of Feedback Control Room Air Temperature Control,Open loop control,An open loop control does not have a direct link between the value of the controlled variable and the controller. An open loop control anticipates the effect of an external variable on the system and adjusts the set point to avoid excessive offset. An example is an outdoor thermostat arranged to control heat to a building in proportion to the calculated load caused by changes in outdoor temperature. In essence, the designer presumes a fixed relationship between outside air temperature and the heat requirement of the building and specifies control action based on the outdoor air temperature. The actual space temperature has no effect on this controller. Because there is no feedback on the controlled variable (space temperature), the control is an open loop.,Single-Seated Valves Double-Seated Valves 單座閥 雙座閥,Three-Way Mixing Valves Three-Way Diverting Valves 三路混合閥 三路換向閥,Sensors Temperature Sensors Humidity Sensors Pressure Transmitters and Transducers Flow Rate Sensors Indoor Air Quality Sensors Lighting Level Sensors Controllers Pneumatic Receiver-Controllers Electric/Electronic Controllers Digital Controllers Thermostats,1. Control Modes On/Off control Proportional control Floating control Integral control Derivative control Variation and Combination of basic modes 2. Open and closed loop control open loop control closed loop control 3. Building Automation Systems 3.1 General 3.2 Basic Considerations 3.3 Computer Based Systems,Frequently used words and phrases: control mode 控制模式 On/Off Control 開/關控制 Proportional control 比例控制 Floating control 浮動控制 Integral control 積分控制 Derivative control 微分控制 Proportional plus Integral (P+I) Control 比例加積分控制 Proportional plus Derivative (PD) Control 比例加微分控制 Proportional plus Integral plus Derivative (P+I+D) Control 比例加積分加微分控制 final control element (FCE) 終端控制元件 Open loop control 開環(huán)控制 Closed loop control 閉環(huán)控制 signal 信號 heater battery 加熱器組 air curtain 空氣幕 sensor 傳感器 electro-mechanical system 電動機械系統(tǒng) pneumatic system 氣動系統(tǒng) pressure switch 壓力開關 humidistat 濕度控制器 time switch 定時開關 building automation system (BAS) 建筑自動化系統(tǒng) energy management system (EMS) 能源管理系統(tǒng) direct digital control (DDC) 直接數(shù)字控制,1. A controller can be made to operate a final control element (FCE), e.g. a valve, damper, or luminaire in a number of different ways in response to a signal. 2. The control mode does not define the means by which control is effected, which may be through mechanical, electro-mechanical, electronic or pneumatic systems. 3. The control sensor usually takes the form of an on/off thermostat, pressure switch, humidistat, time switch, etc. and operates such that below the set point the contacts open.,controller: 控制器 final control element (FCE): 終端控制元件 damper: 閘板 luminaire: 照明 signal: 信號,control mode: 控制模式 electro-mechanical: 機電的 pneumatic: 氣動的,on/off: 開或關 pressure switch: 壓力開關 humidistat: 濕度調節(jié)器 恒濕器,4. Proportional control action refers to a control element having an output signal proportional to its input signal. 5. If the scale range of a temperature controller is from 0oC to 100oC and the proportional band setting is such that the controlled variable must change from through 40oC to 80oC to make the valve move from full open to shut, then the proportional band is (80-40)/100=40%. 6. This mode of operation depends on the use of a dead (neutral) zone in the controlled variable. In this zone the correcting element is not power controlled and remains in its last pulsed position until the controlled variable moves outside the dead zone.,proportional control: 比例控制,dead (neutral) zone: 停滯區(qū) 中性區(qū) correcting element: 修正元件 pulsed: 搏動的 跳動的,proportional band: 比例帶 full open: 完全打開,8. This action is used to eliminate overshoot during a fast load change. Derivative control is mainly applied in special process systems. 9. While floating and proportional control actions may be used on their own, derivative control must always be used in combination with proportional or floating action.,overshoot: 超出 超過 過分 load change: 負荷變化 derivative control: 微分控制,How to translate?,10. Control systems are applied to control loops, each loop normally comprising one section of an overall plant, e.g. reheater, smoke alarm. 11. When the condition of the controlled variable changes in closed loop control the sensor detects the change and initiates correcting action to final control element. 12. The effect of this is reflected in the controlled variable and reassessed by sensor which continuously provides feedback to the controller.,control loops: 控制環(huán)路 comprising: 構成 reheater: 再熱器 smoke alarm: 煙霧報警器,closed loop control: 閉環(huán)控制 detect: 探測 initiate: 觸發(fā) 開始,reassess: 再評估 feedback: 反饋,13. The simplest form of such a loop would be the detection of smoke where a local/or remote alarm is initiated by a smoke detector without any feedback to the smoke sensor. 15. Most thermostatic control manufacturers now market buildings automation systems to monitor and control other building services such as energy, security and fire protection systems.,alarm: 報警器 smoke sensor: 煙霧傳感器,thermostatic: 溫度調節(jié)裝置的 market: 使進入市場 security: 安全 fire protection systems: 防火系統(tǒng),16. It is always advisable to question the level and validity of the software offered to perform the tasks required in the context of building services automation. 18. One other area which requires emphasis is the possible susceptibility of all processor based systems to electrical interference, however caused.,advisable: 可取的 明智的 question: 提出問題 質詢 validity: 有效性 context: 上下文 領域,emphasis: 強調 susceptibility: 易感性 interference: 干擾 干涉,19. The principles apply whether the system has one unit with 10-20 points or multiple processors and outstations serving 10,000 points. 20. It is essential that the specification for any BAS is precisely detailed in terms of all performance, requirements, functional sequences and clearly defined interface conditions for every facility required.,point: 控制點 outstation:設在邊遠地區(qū)的分站 邊遠哨所 遠程控制中心,BAS: building automation systems 建筑自動化系統(tǒng) detail: 詳述 細說 in terms of: 按照 根據(jù) functional sequence: 功能順序 interface condition: 界面條件 facility: 設施,22. The centralization of the logic equipment allows greater flexibility of

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
  • 4. 未經(jīng)權益所有人同意不得將文件中的內容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
  • 6. 下載文件中如有侵權或不適當內容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論