1、 B13沭陽縣長莊小學(xué)工程監(jiān)理實(shí)施細(xì)則(土建部分 ) 內(nèi)容提要:專業(yè)工程特點(diǎn)監(jiān)理工作流程監(jiān)理工作控制目標(biāo)及控制要點(diǎn)監(jiān)理工作方法及措施 項(xiàng)目監(jiān)理機(jī)構(gòu)(章): 專業(yè)監(jiān)理工程師: 總監(jiān)理工程師: 日期: 江蘇省建設(shè)廳監(jiān)制目 錄一、編制說明······························
2、3;·················································
3、3;·········2二、工程概況·······································
4、83;·················································
5、83;3三、適用范圍 ················································&
6、#183;·······································3四、監(jiān)理工作流程········
7、3;·················································
8、3;·······················3五、基槽開挖工程監(jiān)理實(shí)施細(xì)則························&
9、#183;·································7六、土方回填壓實(shí)工程監(jiān)理實(shí)施細(xì)則·············
10、183;····································9七、砌體工程質(zhì)量監(jiān)理實(shí)施細(xì)則···········
11、;··············································11八、鋼筋工程質(zhì)量控制監(jiān)理實(shí)施細(xì)則·
12、;················································15九、砼工程質(zhì)量監(jiān)理
13、實(shí)施細(xì)則·················································
14、183;···········22十、模板工程質(zhì)量監(jiān)理實(shí)施細(xì)則···································
15、3;············· ····28十一、防水監(jiān)理細(xì)則······························
16、3;···············································30· 一、工程項(xiàng)目概
17、況1.1工程名稱: 江蘇省沭陽縣長莊小學(xué)。1.2 工程地點(diǎn):沭陽縣長莊。1.3 工程主要參建單位: 建設(shè)單位:江蘇省沭陽長莊小學(xué)。 設(shè)計(jì)單位:江蘇省教育建筑設(shè)計(jì)院。 監(jiān)理單位:江蘇鴻成工程造價(jià)咨詢有限公司。 質(zhì)量監(jiān)督單位:沭陽縣質(zhì)量監(jiān)督站1.4 工程總建筑面積約14545平方米,學(xué)校有教學(xué)區(qū)、生活區(qū)、運(yùn)動(dòng)區(qū)等功能區(qū),可滿足學(xué)生學(xué)習(xí)和生活需求。1.5建筑類型:造價(jià)人才網(wǎng)本工程建筑為三類工程,建筑耐火等級二級,抗震設(shè)防烈度7度,設(shè)計(jì)使用年限為50年。1.6 工程造價(jià):1898萬元。1.7 工程工期:250天。1.8 工程質(zhì)量要求:合格。二、本監(jiān)理實(shí)施細(xì)則的編制依據(jù):2.1 國家和有關(guān)部門制定的法律
18、、法規(guī)、標(biāo)準(zhǔn)、規(guī)范、規(guī)程、技術(shù)措施、辦法、規(guī)定等。2.2 政府主管部門批準(zhǔn)的建設(shè)計(jì)劃、規(guī)劃等。2.3 已通過有關(guān)部門審查的設(shè)計(jì)圖紙及設(shè)計(jì)變更。2.4 業(yè)主與承包單位依法訂立的工程承包合同, 監(jiān)理委托合同。2.5 已批準(zhǔn)的監(jiān)理規(guī)劃。2.6有關(guān)規(guī)范和規(guī)程 1建筑工程施工質(zhì)量驗(yàn)收統(tǒng)一標(biāo)準(zhǔn) GB50300200l 2建筑地基基礎(chǔ)工程施工質(zhì)量驗(yàn)收規(guī)范 GB502022002 3砌體工程施工質(zhì)量驗(yàn)收規(guī)范 GB502032002 4混凝土結(jié)構(gòu)工程施工質(zhì)量驗(yàn)收規(guī)范 GB502042002 5鋼結(jié)構(gòu)工程施工質(zhì)量驗(yàn)收規(guī)范 GB50205200l 6木結(jié)構(gòu)工程質(zhì)量驗(yàn)收規(guī)范 GB502062002 7屋面工程質(zhì)量驗(yàn)收
19、規(guī)范 GB502072002 8地下防水工程質(zhì)量驗(yàn)收規(guī)范 GB502082002 9建筑地面工程施工質(zhì)量驗(yàn)收規(guī)范 GB502092002 10建筑裝飾裝修工程質(zhì)量驗(yàn)收規(guī)范 GB502lO200l 11建筑給水排水及采暖工程施工質(zhì)量驗(yàn)收規(guī)范 GB502422002 12通風(fēng)與空調(diào)工程施工質(zhì)量驗(yàn)收規(guī)范 GB502432002 13建筑電氣安裝工程施工質(zhì)量驗(yàn)收規(guī)范 GB50303200214建筑電梯工程施工質(zhì)量驗(yàn)收規(guī)范 GB503lO20 15.建設(shè)工程監(jiān)理規(guī)范 GB503192000 16. 混凝土結(jié)構(gòu)施工圖平面整體表示方法制圖規(guī)則和構(gòu)造詳圖03G101 適用本工程的其他國家標(biāo)準(zhǔn)三、監(jiān)理工作的控制
20、要點(diǎn)及目標(biāo)一、質(zhì)量控制(一)、質(zhì)量的事前控制1、 熟悉圖紙和有關(guān)設(shè)計(jì)文件,規(guī)范、規(guī)程、標(biāo)準(zhǔn)。2、 參加圖紙會(huì)審,掌握設(shè)計(jì)意圖。3、 審查施工單位的資質(zhì),有關(guān)人員及特殊工種上崗證書。4、 審查施工單位提交的施工組織設(shè)計(jì)、工程監(jiān)理施工方案。5、 工程涉及的材料,構(gòu)配件和設(shè)備質(zhì)量,必須符合設(shè)計(jì)及施工驗(yàn)收規(guī)范,其質(zhì)量控制基本程序如下:承包單位填寫工程/材料/設(shè)備報(bào)驗(yàn)單承包單位另選監(jiān)理工程師審核方法:1、 審核質(zhì)量保證資料2、 到廠家考察3、 進(jìn)行材料試驗(yàn)4、 進(jìn)行驗(yàn)定復(fù)試6、7、 根據(jù)建設(shè)部文件規(guī)定實(shí)行見證取樣及選樣制度。8、 檢查施工單位進(jìn)場機(jī)械設(shè)備是否符合生產(chǎn)要求。(二)、質(zhì)量的事中控制嚴(yán)格進(jìn)行工
21、序間交接檢查。(1) 加強(qiáng)隱檢工程質(zhì)量的復(fù)核。(2) 審核施工單位提出質(zhì)量技術(shù)資料。(3) 發(fā)生質(zhì)量缺陷時(shí),及時(shí)作出處理決定及實(shí)施。(4) 實(shí)施旁站監(jiān)督。(6)對完成的分項(xiàng)、分部工程,按質(zhì)量評定標(biāo)準(zhǔn)和方法進(jìn)行檢查驗(yàn)收。2、隱蔽工程驗(yàn)收所有隱蔽工程驗(yàn)收均應(yīng)在承包單位自行驗(yàn)收確認(rèn)后,提前24小時(shí)交于監(jiān)理人員各專業(yè)復(fù)驗(yàn)簽證,未經(jīng)復(fù)驗(yàn)簽證一律不得進(jìn)行隱蔽。各項(xiàng)工程質(zhì)量保證資金齊全分部分項(xiàng)工程自檢合格,隱評工作完成隱、預(yù)檢工程分部分項(xiàng)工程分別驗(yàn)收簽認(rèn)完成施工單位施工單位施工單位填報(bào)表項(xiàng)目監(jiān)理部施工單位1、 審核各項(xiàng)質(zhì)量保證資料是否齊全合格;2、 檢查隱、預(yù)檢及分部分項(xiàng)工程是否完成;3、 檢查分部分項(xiàng)工程
22、質(zhì)量是否合格。項(xiàng)目監(jiān)理部各有關(guān)專業(yè)監(jiān)理工程師驗(yàn)收不合格監(jiān)理工程師驗(yàn)收合格可進(jìn)行下一道工序施工單位監(jiān)理工程師四、主要分部分項(xiàng)工程質(zhì)量控制要點(diǎn):(一)、基槽開挖工程監(jiān)理實(shí)施細(xì)則1、監(jiān)理目標(biāo):按圖施工,符合驗(yàn)評規(guī)范檢查標(biāo)準(zhǔn)要求。2、監(jiān)理工作流程:熟悉圖紙,審核施工單位報(bào)驗(yàn)的土方開挖方案,按要求施工單位報(bào)驗(yàn)地質(zhì)勘探現(xiàn)場土質(zhì)情況以及水準(zhǔn)點(diǎn)復(fù)核情況,施工單位報(bào)驗(yàn)基槽放線報(bào)驗(yàn)單,監(jiān)理人員跟蹤檢查基槽開挖質(zhì)量,施工單位自檢合格,填報(bào)工序質(zhì)量報(bào)驗(yàn)單監(jiān)理人員組織有關(guān)人員現(xiàn)場檢查驗(yàn)收,簽署驗(yàn)收意見,是否同意下道工序施工。3、關(guān)鍵質(zhì)量控制點(diǎn)3.1、 基槽開挖前必須具備完整的地質(zhì)勘察資料。3.2、施工前必須查明影響范圍
23、內(nèi)已有建筑物,地下管道設(shè)施等的位置,并提出預(yù)防監(jiān)測有效措施。3.3、 土方工程施工,應(yīng)經(jīng)常測量和校核其平面位置,水平標(biāo)高和邊坡坡度。龍門樁和水準(zhǔn)控制點(diǎn)應(yīng)采取可靠的保護(hù)措施,定期復(fù)測和檢查,土方不應(yīng)堆在基坑邊緣。3.4、 基槽開挖中要檢查開挖尺寸范圍,基底標(biāo)高基底土質(zhì)等情況。3.5、 基槽開挖完成后,應(yīng)邀請勘察設(shè)計(jì)單位到場驗(yàn)收,合格后方可進(jìn)行下一道工序施工。4、常見質(zhì)量問題4.1、 基底土質(zhì)不符合設(shè)計(jì)要求。4.2、基底標(biāo)高誤差太大。4.3、基坑(槽)軸線偏位或長、寬尺寸不足。4.4、邊坡放坡系數(shù)不足導(dǎo)致邊坡塌方。4.5、基底被擾動(dòng)或基坑(槽)浸水。5、控制措施5.1、請勘察、設(shè)計(jì)單位共同鑒定驗(yàn)收
24、。5.22、 對不符合要求的區(qū)域,及時(shí)進(jìn)行地基處理。5.3、 控制邊坡不小于施工規(guī)范規(guī)定。5.4、 控制坡頂堆載。5.5、 開挖后立即組織驗(yàn)收,合格后應(yīng)立即進(jìn)行下道工序施工。5.6、 做好場地排水工作。6、檢驗(yàn)標(biāo)準(zhǔn):現(xiàn)行施工規(guī)范、檢查標(biāo)準(zhǔn)及設(shè)計(jì)文件。(二)、土方回填壓實(shí)工程監(jiān)理實(shí)施細(xì)則1、監(jiān)理目標(biāo):回填土密實(shí)應(yīng)符合規(guī)范要求2、監(jiān)理工作流程:熟悉圖紙,審核施工單位報(bào)驗(yàn)的土方回填方案,要求施工單位報(bào)驗(yàn)填方土質(zhì)情況,施工單位報(bào)驗(yàn)基底標(biāo)高、壓實(shí)情況,監(jiān)理人員跟蹤檢查填方過程中的排水措施、土層填實(shí)厚度、含水量、壓實(shí)程度、施工單位自檢合格,填報(bào)工序質(zhì)量報(bào)驗(yàn)單監(jiān)理組織有關(guān)人員現(xiàn)場檢查驗(yàn)收,簽署驗(yàn)收意見,是否
25、同意下道工序施工。3、控制要點(diǎn)及強(qiáng)制控制條文3.1、土方回填前應(yīng)清除基底的垃圾、樹根等雜物,抽除坑穴積水、淤泥,驗(yàn)收基底標(biāo)高。如在耕植土或松土上填方,應(yīng)在基底壓實(shí)后再進(jìn)行。3.2、填方施工過程中應(yīng)檢查排水措施、每層填筑厚度、含水率控制、壓實(shí)程度等。3.3、對填方土料應(yīng)按設(shè)計(jì)要求驗(yàn)收后方可填入。4、常見質(zhì)量問題4.1、回填土料不符合設(shè)計(jì)要求和施工規(guī)范規(guī)定。4.2、基礎(chǔ)被回填土擠動(dòng)或裂縫。4.3、填方干土質(zhì)量、密度達(dá)不到設(shè)計(jì)要求。4.4、回填土沉陷。5、控制措施5.1、及時(shí)控制、按圖施工。5.2、 認(rèn)真執(zhí)行規(guī)范中關(guān)于填方土料的規(guī)定。5.3、回填時(shí)基礎(chǔ)工程應(yīng)達(dá)到規(guī)定強(qiáng)度。5.4、 回填土應(yīng)分層進(jìn)行,
26、每層厚度不超過施工規(guī)范的規(guī)定。5.5、 夯實(shí)機(jī)具和工藝符合施工組織設(shè)計(jì)的規(guī)定,必要時(shí)由試驗(yàn)確定。5.6、 填土前清除坑(槽)內(nèi)的雜物和松土。5.7、 選用合適的填方土料。5.8、 做好排水設(shè)施。6、檢驗(yàn)標(biāo)準(zhǔn):現(xiàn)行施工規(guī)范、驗(yàn)收標(biāo)準(zhǔn)及設(shè)計(jì)文件。(三)、鋼筋工程質(zhì)量控制監(jiān)理實(shí)施細(xì)則一、監(jiān)理目標(biāo):原材料質(zhì)量必須符合設(shè)計(jì)及有關(guān)標(biāo)準(zhǔn)規(guī)定,制作安裝質(zhì)量符合驗(yàn)評標(biāo)準(zhǔn)規(guī)定。二、監(jiān)理工作流程:熟悉圖紙,審核施工單位報(bào)驗(yàn)的鋼筋制作安裝方案,要求施工單位報(bào)驗(yàn)鋼筋合格證出廠檢驗(yàn)、復(fù)驗(yàn)報(bào)告、有焊接的還要報(bào)驗(yàn)焊接試驗(yàn)報(bào)告 ,施工單位報(bào)驗(yàn)鋼筋放樣報(bào)驗(yàn)單,監(jiān)理人員跟蹤檢查鋼筋安裝質(zhì)量,施工單位自檢合格,填報(bào)工序質(zhì)量報(bào)驗(yàn)單監(jiān)理
27、組織有關(guān)人員現(xiàn)場檢查驗(yàn)收,簽署驗(yàn)收意見,是否同意下道工序施工。三、控制要點(diǎn)及強(qiáng)制控制條文1、鋼筋進(jìn)場時(shí)應(yīng)檢查出廠質(zhì)量證明書,或試驗(yàn)報(bào)告單,鋼筋表面或每捆(盤)鋼筋均應(yīng)有標(biāo)志,進(jìn)場時(shí)應(yīng)按批號及直徑分批檢驗(yàn)。檢驗(yàn)內(nèi)容包括查對標(biāo)志、外觀檢查、并抽取試樣作力學(xué)性能試驗(yàn),合格后方可使用。2、當(dāng)發(fā)現(xiàn)鋼盤脆斷,焊接性能不良或力學(xué)性能顯著不正常等現(xiàn)象時(shí),應(yīng)對該批鋼筋進(jìn)行化學(xué)成分檢驗(yàn)或其他專項(xiàng)檢驗(yàn)。3、鋼筋焊接前必須檢查焊工是否有上崗證,并根據(jù)施工條件進(jìn)行試焊,合格后方可施焊,并在現(xiàn)場隨機(jī)抽樣進(jìn)行力學(xué)性能試驗(yàn),合格后方可下道工序施工。4、受力鋼筋采用焊接接頭時(shí),同一構(gòu)件內(nèi)的焊接接頭應(yīng)相互錯(cuò)開,在任一焊接接頭中心
28、至長度為鋼筋直徑的35 倍且不小于500mm 的區(qū)段內(nèi),同一根鋼筋不得有兩個(gè)接頭,在該區(qū)段內(nèi)有接頭的受力鋼筋截面面積占受力鋼筋總截面面積的百分率應(yīng)符合下列規(guī)定:5、在受拉區(qū)不宜大于50% 6、接頭不宜設(shè)置在有抗震設(shè)防要求的框架梁端,柱端的箍筋加密區(qū)。7、直接承受動(dòng)力荷載的結(jié)構(gòu)構(gòu)件中,不宜采用焊接接頭。8、同一構(gòu)件中相鄰縱向受力鋼筋的綁扎搭接接頭宜相互錯(cuò)開,綁扎搭接接頭的橫向凈距不應(yīng)小于鋼筋的直徑,且不應(yīng)小于25mm ,鋼筋綁扎搭接接頭連接區(qū)段的長度為1.3L1, 同一連接區(qū)段內(nèi)縱向受拉鋼筋接頭面積百分率應(yīng)符合下列規(guī)定:9、對梁類、板類及墻類構(gòu)件,不宜大于25% 10、對柱類構(gòu)件,不宜大于50%
29、 11、當(dāng)工程中確有必要增大接頭面積百分率時(shí),對梁類構(gòu)件不應(yīng)大于50%,對其他構(gòu)件可根據(jù)實(shí)際情況放寬。12、在梁、柱類構(gòu)件的縱向受力鋼筋搭接長度范圍應(yīng)按設(shè)計(jì)要求配置箍筋,當(dāng)設(shè)計(jì)無具體要求時(shí),應(yīng)符合下列規(guī)定:13、 箍筋直徑不應(yīng)小于搭接較大直徑的0.25 倍。14、 受力搭接區(qū)段的箍筋間距不應(yīng)大于搭接鋼筋較小直徑的5 倍,且不應(yīng)小于100mm 。15、受壓搭接區(qū)段的箍筋間距不應(yīng)大于搭接鋼筋較小直徑的10 倍,且不應(yīng)大于200mm 。16、當(dāng)柱中縱向受力鋼筋直徑大于25mm 時(shí),應(yīng)在搭接接頭兩個(gè)端面外100mm 范圍內(nèi)各設(shè)置兩個(gè)箍筋,其間距為50mm 。17、鋼筋安裝時(shí),受力鋼筋的品種、級別、規(guī)格
30、和數(shù)量必須符合設(shè)計(jì)要求。四、常見質(zhì)量問題1、鋼筋使用前,不按規(guī)范規(guī)定抽取試樣作機(jī)械性能試驗(yàn)。2、鋼筋銹蝕嚴(yán)重。3、鋼筋彎曲不直。4、鋼筋裂紋:一類是變形鋼筋“縱脅”的縱向裂紋,二是鋼筋冷加工時(shí)產(chǎn)生的裂紋。5、鋼筋脆斷,包括鋼筋冷加工中或運(yùn)輸裝卸中脆斷,以及電弧點(diǎn)焊后脆斷。6、冷拉鋼筋或冷拔鋼絲的機(jī)械性能達(dá)不到設(shè)計(jì)要求和施工規(guī)范的規(guī)定。7、鋼筋品種、規(guī)格、尺寸、形狀、數(shù)量、間距不符合設(shè)計(jì)要求和施工規(guī)范的規(guī)定。8、鋼筋接頭連接方法和接頭數(shù)量及布置不符合設(shè)計(jì)要求和施工規(guī)范的規(guī)定。9、鋼筋綁扎的缺扣、松扣多,導(dǎo)致鋼筋網(wǎng)或鋼筋骨架變形。鋼筋綁扎接頭的做法與布置不符合施工規(guī)范的規(guī)定。10、彎鉤朝向不正確,
31、彎鉤在小構(gòu)件中外露。11、箍盤端頭彎鉤形式不符合設(shè)計(jì)要求和施工規(guī)范的規(guī)定。12、鋼筋網(wǎng)中主副鋼筋倒置,在板類構(gòu)件往往造成計(jì)算市度明顯減小,從而引起承載能力不足。13、鋼筋安裝位置偏差過大,或墊塊設(shè)置等固定方法不當(dāng),造成鋼筋嚴(yán)重錯(cuò)位。14、鋼筋少放或漏放。15、鋼筋代換不當(dāng),又未征得設(shè)計(jì)單位同意,造成結(jié)構(gòu)構(gòu)件的性能下降。五、控制措施監(jiān)理工程師應(yīng)嚴(yán)格審查鋼筋工程專項(xiàng)施工方案審查后督促施工單位按批準(zhǔn)的施工方案施工。1、對現(xiàn)場用鋼筋,監(jiān)理工程師必須嚴(yán)格審查其出廠質(zhì)量證明書、檢測報(bào)告。注意:如為復(fù)印件,應(yīng)注明原件存放外,并有經(jīng)辦人簽字和時(shí)間,要求加蓋原件存放單位的公章。2、鋼筋進(jìn)場后,監(jiān)理工程師應(yīng)埋外觀
32、合格鋼筋要求立即清退出場。3、嚴(yán)格鋼筋的采購與驗(yàn)收工作,防止不合格產(chǎn)品流入施工現(xiàn)場。4、應(yīng)按爐罐(批)號及直徑分批檢查鋼筋標(biāo)志和外觀質(zhì)量。5、按現(xiàn)行國家有關(guān)標(biāo)準(zhǔn)的規(guī)定現(xiàn)場抽取試樣作力學(xué)性能試驗(yàn),合格后方可使用。6、鋼筋除銹。7、對顆粒狀或片狀老銹必須清除。8、鋼筋除銹后仍留有麻點(diǎn)者,嚴(yán)禁按原規(guī)格使用。9、鋼筋冷加工。10、采用調(diào)直機(jī)冷拉,或人工等方法調(diào)直。11、對嚴(yán)重曲折的鋼筋,尤其是曲折自圓弧半徑小的“硬彎”,調(diào)直后應(yīng)檢查有無裂紋。12、對矯正后仍不直或有裂紋的鋼筋,不準(zhǔn)用作受力鋼筋。13、鋼筋冷加工的工藝參數(shù)(如彎曲時(shí)的彎心直徑等)應(yīng)符合施工規(guī)范的規(guī)定。14、鋼筋出現(xiàn)裂紋后,均應(yīng)認(rèn)真分析,
33、無充分根據(jù)時(shí),不準(zhǔn)使用到工程中去。15、 一、二級和進(jìn)口鋼筋用電弧點(diǎn)焊固定鋼筋必須經(jīng)過試驗(yàn)鑒定后方可使用。17、預(yù)檢鋼筋母材的質(zhì)量,以確定其是否適合于冷拉或冷拔,根據(jù)檢驗(yàn)結(jié)果,確定工藝參數(shù),如冷拉率、冷拔的總壓縮率等。18、嚴(yán)格控制冷加工工藝。19、冷拉和冷拔鋼筋的檢查驗(yàn)收應(yīng)符合施工規(guī)范的地規(guī)定。20、加強(qiáng)質(zhì)量檢驗(yàn)工作,控制允許偏差項(xiàng)目不超過建筑工程質(zhì)量檢驗(yàn)評定標(biāo)準(zhǔn)中的有關(guān)規(guī)定。21、鋼筋綁扎22、應(yīng)嚴(yán)格遵守下述規(guī)定,軸心受拉和小偏心受拉桿件中的鋼筋接關(guān),軸心受壓和偏心受壓桿件鋼筋直徑大于25mm 時(shí)的接頭均應(yīng)采用焊接。23、合理配料,防止接頭集中。24、正確理解規(guī)范中規(guī)定的同一截面的含義。2
34、5、分不清鋼筋是受拉還是受壓時(shí),均就按受拉要求施工。26、控制缺扣、松扣的數(shù)量不超過應(yīng)綁扣數(shù)的10%20%,且不應(yīng)集中。27、鋼筋網(wǎng)或骨架的堆放場地平整,運(yùn)輸安裝方法正確。28、彎鉤朝向應(yīng)按照施工規(guī)范有關(guān)規(guī)定執(zhí)行。29、對薄板等構(gòu)件彎鉤安裝后,如超過板厚,應(yīng)將彎鉤放斜,以保證有足夠的保護(hù)層。30、箍筋的彎鉤角度和平直段長度嚴(yán)格執(zhí)行施工規(guī)范的規(guī)定。31、綁扎鋼筋骨架時(shí),防止將箍筋接頭重復(fù)交搭于一根或兩根縱筋上。32、綁扎接頭的搭接長度應(yīng)符合施工規(guī)范的規(guī)定,其最低要求為搭接長度不小于規(guī)定值95%。33、接頭的中心和兩端均用鐵絲扎牢。34、受拉區(qū)內(nèi)1 組鋼筋綁扎接頭末端應(yīng)做彎鉤。35、認(rèn)真學(xué)習(xí)圖紙,
35、并作技術(shù)交底,以書面交底為宜。36、加強(qiáng)質(zhì)量檢查,認(rèn)真做好隱蔽工程驗(yàn)收記錄。37、認(rèn)真按照施工操作規(guī)程及圖紙要求施工,并加強(qiáng)自檢、互檢、交接檢。38、控制砼的澆灌、振搗成型的方法,防止鋼筋產(chǎn)生變形和錯(cuò)位。39、認(rèn)真做好配料工作,按圖紙核對配料單和料牌。40、鋼筋綁扎和安裝前認(rèn)真熟悉圖紙和配料單,確定合理的綁扎順序。41、如砼澆筑后發(fā)現(xiàn)露筋,應(yīng)及時(shí)提請有關(guān)人員進(jìn)行處理。42、鋼筋代換除了滿足強(qiáng)度要求外,還應(yīng)滿足設(shè)計(jì)規(guī)定的抗裂、剛度、抗震以及構(gòu)造規(guī)定等要求,鋼筋代換必須征得設(shè)計(jì)單位的同意。43、鋼筋焊接44、焊接材料,焊接方法與工藝參數(shù),必須符合設(shè)計(jì)要求及施工組織設(shè)計(jì)的規(guī)定。45、焊工必須有考試合
36、格證,并只準(zhǔn)在規(guī)定范圍內(nèi)進(jìn)行焊接操作。46、焊接前必須根據(jù)施工條件試焊,合格后方可在工程中施焊。47、按照與鋼筋母材等強(qiáng)度原則選用焊條,但對幫條焊或搭接焊可以采用比母材強(qiáng)度低一級的焊條。48、 焊件剛性大,鋼筋母材中碳、硫、磷含量偏高或施焊環(huán)境溫度較低時(shí),宜用堿性焊條,防止焊件裂紋。49、在滿足設(shè)計(jì)要求和操作性能的前提下,應(yīng)選用酸性焊條,以改善焊工勞動(dòng)條件,提高效率和降低成本。50、幫條長度應(yīng)符合施工規(guī)范的規(guī)定,幫條沿接頭中心線位移不大于05,接頭處彎折不大于4D,鋼筋軸線位移不大于0.1D ,且不大于3mm ,為此要求鋼筋下料和組對由專人進(jìn)行,合格后方可焊接。51、焊縫長度應(yīng)沿幫條或搭接長度
37、滿焊,最大誤差允許少0.5D。52、檢查焊件尺寸,焊縫寬度不得小于0.7D,允許誤差0.1D,焊縫厚度不得小于0.3D,允許誤差0.05D。發(fā)現(xiàn)尺寸不足,應(yīng)清除焊渣后及時(shí)補(bǔ)焊。53、選用合適的電流,防止電流過大,焊弧不可拉得過長,并控制焊條角度和運(yùn)弧方法,焊條在收弧處應(yīng)多停留一些時(shí)間。采用幾次斷續(xù)滅弧補(bǔ)焊,填凹坑(堿性直流焊條不可用此法,以防產(chǎn)生氣孔),防止帶電金屬與鋼筋接觸產(chǎn)生電弧。合理選用焊條直徑,采用性能良好的焊條,正確選用焊接工藝參數(shù)。54、鋼筋接頭的加工尺寸準(zhǔn)確,組對時(shí)嚴(yán)格控制其誤差不超過規(guī)定。55、焊接區(qū)鋼筋表面應(yīng)潔凈,清除氧化鐵皮和氣割熔渣。56、鋼筋焊接部分應(yīng)整潔并除銹,多層施
38、焊時(shí),應(yīng)將每層焊渣及時(shí)清除。57、焊接中控制熔渣流動(dòng)方向,將熔渣吹到旁邊或后邊。58、焊條受潮、藥皮開裂、剝落以及沓芯銹蝕的沓條均不準(zhǔn)使用。59、適當(dāng)加大焊接電流,降低焊接速度,使焊縫金屬中氣體完全外逸。六、檢驗(yàn)標(biāo)準(zhǔn):現(xiàn)行施工規(guī)范、驗(yàn)收標(biāo)準(zhǔn)及設(shè)計(jì)文件。(四)、模板工程質(zhì)量監(jiān)理實(shí)施細(xì)則1、監(jiān)理目標(biāo):按圖施工,符合驗(yàn)收規(guī)范檢查標(biāo)準(zhǔn)要求。2、監(jiān)理工作流程:熟悉圖紙,審核施工單位報(bào)驗(yàn)的模板施工方案,按要求施工單位報(bào)驗(yàn)?zāi)0逶牧系臋z查情況,施工單位報(bào)驗(yàn)?zāi)0骞ば蚍艠淤|(zhì)量報(bào)驗(yàn)單,監(jiān)理人員跟蹤檢查施工質(zhì)量,施工單位自檢合格填報(bào)工序質(zhì)量報(bào)驗(yàn)單監(jiān)理組織有關(guān)人員現(xiàn)場檢查驗(yàn)收,簽署驗(yàn)收意見。3、控制要點(diǎn)及強(qiáng)制性條文3
39、.1、安裝現(xiàn)澆結(jié)構(gòu)的上層模板及其支架時(shí),下層樓板應(yīng)具有承受上層荷載能力,或加設(shè)支架,上、下層支架的立柱應(yīng)對準(zhǔn),并鋪設(shè)墊板。3.2、模板及其支架拆除順序及安全措施應(yīng)按經(jīng)審查的施工技術(shù)方案執(zhí)行。3.3、在澆筑砼之前,應(yīng)對模板工程進(jìn)行驗(yàn)收。3.4、在涂刷模板隔離劑時(shí),不得沾污鋼筋和砼接槎處。3.5、模板的接縫不應(yīng)漏漿,在澆筑砼之前,木模板應(yīng)澆水濕潤,但模板內(nèi)不應(yīng)有積水。3.6、模板與砼的接觸面應(yīng)清理干凈并涂刷隔離劑,但不得使用影響結(jié)構(gòu)性能或防礙裝飾工程施工的隔離劑。3.7、澆筑砼之前模板內(nèi)的雜物應(yīng)清理干凈。3.8、對清水砼工程及裝飾工程,應(yīng)使用能達(dá)到設(shè)計(jì)效果的模板。3.9、用作模板的地坪、胎模等應(yīng)平
40、整光潔,不得產(chǎn)生影響構(gòu)件質(zhì)量的下沉、裂縫、起砂、起鼓。3.10、對跨度大于4m 的現(xiàn)澆鋼筋砼梁、板,其模板應(yīng)按設(shè)計(jì)要求起拱。3.11、固定在模板上的預(yù)埋件、預(yù)留孔和預(yù)留洞均不得遺漏,且應(yīng)安裝牢固,其偏差應(yīng)符合規(guī)定。4、常見質(zhì)量問題4.1、帶形基礎(chǔ)的模板4.2、尺寸偏差過大,沿長度方向模板上口不直。3、模板構(gòu)造及方法不正確,導(dǎo)致上臺階模板的下口陷入砼內(nèi),或下口固定不牢固。4、梁模板5、梁標(biāo)高誤差大,梁底不平,撓曲變形過大。6、梁外形不平直。7、梁側(cè)脹模。8、圈梁模板:模板固定不牢,變形過大,導(dǎo)致圈梁側(cè)面與墻表面的平整度誤差太大,或澆筑砼時(shí)漏漿嚴(yán)重。9、柱模板10、柱軸線偏移過大。11、脹模、漏漿
41、。12、柱身扭曲。13、板模板:板底與砼的接觸面粘結(jié),導(dǎo)致表面清理困難。14、其他各類構(gòu)件:模板與砼的接觸面粘結(jié),導(dǎo)致表面清理困難。5、控制措施1、模板工程專項(xiàng)施工方案必須經(jīng)監(jiān)理工程師審查同意。2、模板與支撐材料3、模板及支撐構(gòu)件應(yīng)有足夠的強(qiáng)度、剛度、構(gòu)造合理、連接牢固可靠,并具有一定的穩(wěn)定性。4、落地支撐的地基應(yīng)夯實(shí)。5、按設(shè)計(jì)或施工規(guī)范的規(guī)定將梁底模起拱。6、梁側(cè)模上、下口的固定方法可靠牢固。模板上口應(yīng)釘木帶,或設(shè)置定長卡具,以保證上口寬度正確。采用正確的支模起拱。圈梁模板上口應(yīng)設(shè)臨時(shí)撐關(guān),保證梁上口尺寸正確。7、成排柱子先支兩端兩根柱模板,支模前,均和彈出通線后,再畫出每個(gè)柱子的位置,柱
42、底處做小方盤模板,保證位置正確,兩端柱模支完并校核無誤后,在柱頂拉設(shè)通線,并以此為依據(jù),支設(shè)中間各柱模板。8、柱模四面應(yīng)設(shè)斜撐,或各柱間用水平桿與剪刀撐固定。9、控制板擱柵截面尺寸與間距,擱柵上表面應(yīng)平整,模板厚度應(yīng)一致。10、模板應(yīng)按規(guī)定起拱。11、模板與砼的接觸面應(yīng)滿涂刷隔離劑,或采用其它防粘結(jié)措施。6、檢驗(yàn)標(biāo)準(zhǔn):現(xiàn)行施工規(guī)范、驗(yàn)收標(biāo)準(zhǔn)及設(shè)計(jì)文件。(五)、砼工程質(zhì)量監(jiān)理實(shí)施細(xì)則一、監(jiān)理目標(biāo):砼工程符合設(shè)計(jì)及驗(yàn)評規(guī)范要求。二、監(jiān)理工作流程:熟悉圖紙、審核施工單位報(bào)驗(yàn)的砼施工方案,要求施工單位報(bào)驗(yàn)水泥、黃砂、碎石等厚材料檢驗(yàn)報(bào)告證明,施工單位報(bào)驗(yàn)砼澆灌申請書,監(jiān)理人員跟蹤監(jiān)理砼澆筑質(zhì)量,施工單
43、位自檢合格,填報(bào)砼質(zhì)量報(bào)驗(yàn)單,監(jiān)理人員組織有關(guān)人員到現(xiàn)場檢查驗(yàn)收,監(jiān)理簽署驗(yàn)收意見,是否同意下道工序施工。三、控制要點(diǎn)及強(qiáng)制性條文1、砼澆筑必須在鋼筋工程及模板工程驗(yàn)收合格后方可進(jìn)行。2、水泥進(jìn)場時(shí)應(yīng)對其品種、級別、包裝或散裝倉號、出廠日期等進(jìn)行檢查,并對其強(qiáng)度、安定性及其他必要的性能指標(biāo)進(jìn)行復(fù)驗(yàn),合格后方可使用。檢查數(shù)量:袋裝不超過200 噸為一批;散裝不超過500 噸為一批,每批抽樣不少天一次。3、砼選用的粗、細(xì)骨料的質(zhì)量應(yīng)進(jìn)行復(fù)驗(yàn),合格后方可使用,現(xiàn)場上要嚴(yán)格控制砂石含泥量和貝殼含量,并且碎石最大粒徑不得超過構(gòu)件截面最小尺寸的1/4,且不得超過鋼筋最小凈間距的3/4。4、拌制砼宜采用飲用
44、水,當(dāng)采用在下水時(shí),應(yīng)檢查水質(zhì)情況。5、砼必須按配合比嚴(yán)格計(jì)量舊料,每個(gè)工作班復(fù)稱、抽查不應(yīng)少于二次。6、砼試塊的留置:砼試塊應(yīng)在澆筑地點(diǎn)隨機(jī)抽取,取樣與試塊留置應(yīng)符合下列規(guī)定:7、每拌制100 盤,且不超過100M3 同配合比的砼,取樣不得少于一次;8、每工作班拌制的同一配合比的砼不足100 盤時(shí),取樣不得少于一次;9、當(dāng)一次連續(xù)澆筑超過100M3 時(shí),同一配合比的砼每200M3 取樣不得少于一次;10、每樓層、同一配合比的砼,取樣不得少于一次;11、每次取樣應(yīng)至少留置一組標(biāo)準(zhǔn)養(yǎng)護(hù)試件,同條件養(yǎng)護(hù)試件的留置組數(shù)應(yīng)根據(jù)實(shí)際需要確定。12、砼運(yùn)輸、澆筑及間歇的全部時(shí)間不應(yīng)超過砼的初凝時(shí)間,同一施
45、工段的砼應(yīng)連續(xù)澆筑,并應(yīng)在底層初凝之前將上層砼澆筑完畢。13、砼的養(yǎng)護(hù):砼澆筑完畢,應(yīng)加以覆蓋和澆水,并就符合下列規(guī)定:14、應(yīng)在澆筑完畢后的12h 以內(nèi)對砼加以覆蓋和澆水。15、 砼澆水養(yǎng)護(hù)的時(shí)間,正常不得少于7d,對有抗?jié)B要求的砼不得少于14d。16、澆水次數(shù)應(yīng)能保持砼表面處于潤濕狀態(tài),養(yǎng)護(hù)用水應(yīng)和拌制用水相同。17、在已澆筑的砼強(qiáng)度未達(dá)到1.2N/mm2 以前,不得在其上踩踏或安裝模板及支架。18、砼強(qiáng)度應(yīng)分批進(jìn)行驗(yàn)收。19、現(xiàn)澆結(jié)構(gòu)的質(zhì)量不應(yīng)有嚴(yán)重缺陷,對已出現(xiàn)的嚴(yán)重缺陷,應(yīng)由施工單位提出技術(shù)處理方案,并經(jīng)監(jiān)理單位認(rèn)可后進(jìn)行處理,對經(jīng)處理的部位應(yīng)重新檢查驗(yàn)收。20、現(xiàn)澆砼結(jié)構(gòu)不應(yīng)有結(jié)構(gòu)
46、性能和使用功能的尺寸偏差,對超過尺寸允許偏差且影響結(jié)構(gòu)性能和安裝,使用功能的部位,應(yīng)由施工單位提出技術(shù)處理方案,并經(jīng)監(jiān)理單位認(rèn)可后進(jìn)行處理,對經(jīng)處理的部位,應(yīng)重新檢查驗(yàn)收。21、結(jié)構(gòu)實(shí)體檢驗(yàn)、條件養(yǎng)護(hù)試件強(qiáng)度檢驗(yàn),其留置的數(shù)量應(yīng)根據(jù)砼工程量和重要性確定,不宜少于10 組,且不應(yīng)少于3 組,等效養(yǎng)護(hù)齡期應(yīng)按日平均溫度逐日累計(jì)達(dá)到600 .d 時(shí),所對應(yīng)的齡期0及以下的齡期不計(jì)入,等效養(yǎng)護(hù)齡期不應(yīng)小于14 天,不宜大于60 天。22、鋼筋保護(hù)層厚度有檢驗(yàn)縱向受力鋼筋允許偏差梁為10mm 、7mm ,板為8mm 、5mm ,并且抽查合格點(diǎn)率為90%以上,方判為合格。四、常見質(zhì)量問題1、砼原材料不符合
47、要求。2、砼和易性不良,主要表現(xiàn)為拌合物松散,粘結(jié)性差,坍落度或工作度不符合要求,砼離析等。3、外加劑的品種和數(shù)量用錯(cuò),導(dǎo)致砼長時(shí)間不硬化,或強(qiáng)度低。4、施工縫位置留置、施工縫處理不當(dāng),出現(xiàn)縫中夾有雜物。5、砼強(qiáng)度達(dá)不到設(shè)計(jì)要求,表現(xiàn)為強(qiáng)度離散和勻質(zhì)性差。6、砼表面蜂窩(指表面無水泥漿,露出石子深度大于5mm ,但小于保護(hù)層厚度的缺陷)。7、砼出現(xiàn)孔洞(指缺陷深度超過保護(hù)層厚度,但小于截面尺寸的1/3)。8、鋼筋外露。9、結(jié)構(gòu)或構(gòu)件變形,超過施工規(guī)范規(guī)定,包括柱與墻垂直度,梁板類構(gòu)件撓度,各類構(gòu)件歪斜凹凸等。10、表面平整度 不符合要求。11、 缺棱掉角。五、控制措施1、砼的原材料2、檢查水泥
48、的出廠合格證,并隨機(jī)抽樣復(fù)試,合格后方可進(jìn)行使用。3、對現(xiàn)場的粗、細(xì)骨料進(jìn)行檢查、復(fù)試,合格后方可使用。4、應(yīng)采用飲用水,如采用地下水及其他水源,應(yīng)進(jìn)行水質(zhì)情況檢查。5、砼粗、細(xì)骨料直徑不應(yīng)超過鋼筋最小凈距的3/4。6、砼的外加劑7、嚴(yán)格按配合比配料。8、防止不同品種外加劑混雜堆放。9、粉狀外加劑受潮結(jié)塊后,應(yīng)烘干、碾碎、過篩后再使用。10、施工縫的留置11、按圖施工,對不準(zhǔn)留置施工縫者,應(yīng)采取相應(yīng)的技術(shù)組織措施。12、 執(zhí)行施工規(guī)范關(guān)于施工縫留置的規(guī)定,繼續(xù)澆筑砼的規(guī)定,以及施工縫處理的要求。13、砼的攪拌14、嚴(yán)格按試驗(yàn)確定的配合比施工,配合比設(shè)計(jì)應(yīng)遵守國家現(xiàn)行標(biāo)準(zhǔn)的規(guī)定,配料誤差不超過施
49、工規(guī)范規(guī)定。配料準(zhǔn)確,并有足夠的攪拌時(shí)間,選用正確運(yùn)輸方法,控制運(yùn)輸時(shí)間不宜過長。15、砼的攪拌時(shí)間應(yīng)控制在23min. 之間。16、所用原材料必須準(zhǔn)確計(jì)量17、砼的運(yùn)輸18、嚴(yán)格控制砼的運(yùn)輸距離和運(yùn)輸間歇時(shí)間,防止產(chǎn)生砼離析現(xiàn)象。19、采用較好的運(yùn)輸工具,防止運(yùn)輸中漏漿。20、砼的澆筑21、砼應(yīng)保持一定的坍落度,坍落度可在拌制地點(diǎn)和澆筑處測量。22、 采用合適的澆筑順序和方法,控制自由下落高度不超過2m??刂茲仓?biāo)高的準(zhǔn)確,如在模板四周彈線,中間用鋼筋等做成的簡易工具測量澆筑高度。23、采用正確的振搗方法,必要時(shí)輔以外部振動(dòng)和人工振搗,防止漏振和過度振搗。按照合理的施工順序,分層、分段澆筑。
50、24、根據(jù)施工組織設(shè)計(jì)及工程實(shí)際情況需要分層澆筑時(shí),分層厚度根據(jù)搗實(shí)方法按照施工規(guī)范要求確定。25、澆筑粗連續(xù)進(jìn)行,停置時(shí)間不宜過長,以防止砼產(chǎn)生離析現(xiàn)象。26、砼試塊留置應(yīng)符合規(guī)范的規(guī)定,宜采用同條件養(yǎng)護(hù)。27、砼的養(yǎng)護(hù)28、在砼澆筑完畢12 小時(shí)內(nèi)應(yīng)進(jìn)行澆水養(yǎng)護(hù)。29、澆水養(yǎng)護(hù)時(shí)間一般不得小于7d,對有抗?jié)B要求的砼不得少于14d。30、砼澆筑方法應(yīng)對稱均勻地進(jìn)行,自由下落高度符合施工規(guī)范的規(guī)定。31、宜安排專人澆水。32、模板、支撐33、模板、支架應(yīng)有足夠的強(qiáng)度、剛度和穩(wěn)定性。34、模板固定要牢固,穩(wěn)定,澆筑過程中設(shè)專人看管模板,及時(shí)修整。35、澆筑時(shí)認(rèn)真檢查模板尺寸、形狀、垂直度、連接構(gòu)
51、造等,發(fā)現(xiàn)問題及時(shí)處理。36、拆模不宜過早,非承重模板宜在1.2Mpa 后拆除,應(yīng)征得監(jiān)理工程師同意后進(jìn)行拆除。37、控制施工荷載。38、模板的架設(shè)及拆除方案應(yīng)報(bào)監(jiān)理工程師審查。39、砼的成品保護(hù)。40、新澆砼面不宜過早上人工堆重物。41、不準(zhǔn)踩踏鋼筋特別是負(fù)彎矩鋼筋,最大限度保持原樣。42、充分認(rèn)識成品保護(hù)的重要性,防止成型后的砼構(gòu)件缺棱掉角。43、砼質(zhì)量事故處理44、發(fā)現(xiàn)砼出現(xiàn)質(zhì)量問題時(shí),應(yīng)首先進(jìn)行分析原因,并及時(shí)報(bào)告。45、對表面出現(xiàn)蜂窩、麻面等問題應(yīng)按規(guī)定及時(shí)進(jìn)行表面處理。六、檢查標(biāo)準(zhǔn):現(xiàn)行施工規(guī)范、驗(yàn)收標(biāo)準(zhǔn)及設(shè)計(jì)文件。(六)、砌體工程質(zhì)量監(jiān)理實(shí)施細(xì)則一、監(jiān)理目標(biāo):砌體質(zhì)量符合驗(yàn)評標(biāo)準(zhǔn)
52、規(guī)定。二、監(jiān)理工作流程:熟悉圖紙,審核施工單位報(bào)驗(yàn)的砌體施工方案要求施工單位報(bào)驗(yàn)水泥、紅磚、砂等原材料檢驗(yàn)報(bào)告證明,施工單位報(bào)驗(yàn)砌體放線報(bào)驗(yàn)單,監(jiān)理人員跟蹤檢查砌體質(zhì)量,施工單位自檢合格,填報(bào)工序質(zhì)量報(bào)驗(yàn)單監(jiān)理組織有關(guān)人員現(xiàn)場檢查驗(yàn)收,簽署驗(yàn)收意見,是否同意下道工序施工。三、控制要點(diǎn)及強(qiáng)制控制條文1、 砌體應(yīng)在地基或基礎(chǔ)工程驗(yàn)評合格后,方可施工。2、 砌筑磚砌體時(shí),磚應(yīng)提前12 天澆水濕潤。3、 砌體工程所用的材料應(yīng)具有質(zhì)量證明書,并應(yīng)符合設(shè)計(jì)要求,水泥應(yīng)按品種、標(biāo)識、出廠日期分別堆放,不得混合使用。砌筑砂漿必須按設(shè)計(jì)配合比下料,砂漿應(yīng)隨拌隨用,最好在3 小時(shí)內(nèi)使用完畢,鋪漿長不得超過750m
53、m 。4、 磚砌體的尺寸和位置、軸線、標(biāo)高、平整度、垂直度、門窗洞口寬度等控制必須在允許偏差范圍內(nèi)。5、磚砌體的轉(zhuǎn)角處及交接處應(yīng)同時(shí)砌筑,嚴(yán)禁無可靠措施的內(nèi)外墻分砌施工,馬牙槎、拉結(jié)筋留置必須按規(guī)范操作。6、磚砌體水平灰縫砂漿飽滿度不得小于80% ,不得出現(xiàn)透明縫,嚴(yán)禁用水沖漿灌縫。7、 磚砌體水平灰縫厚度和豎向灰縫寬度應(yīng)在812mm 。8、 磚砌體應(yīng)上下錯(cuò)縫、內(nèi)外搭砌。磚柱不得采用包心砌法。9、 在墻上留置臨時(shí)施工洞口,其側(cè)邊離交接的墻面不應(yīng)小于500mm 。10、 砂漿試樣應(yīng)在攪拌機(jī)出料口隨機(jī)取樣、制作,應(yīng)在同一盤砂漿中取樣制作,同盤砂漿只應(yīng)制作一組試樣。取樣頻率為每一樓層或250 立方米砌體中的各種強(qiáng)度等級的砂漿、每臺攪拌應(yīng)至少檢查一次,每次至少應(yīng)一組試塊,砂漿強(qiáng)度應(yīng)以標(biāo)準(zhǔn)養(yǎng)護(hù)、齡期28 天的試塊抗壓試驗(yàn)結(jié)果為準(zhǔn)。四、常見質(zhì)量問題1、磚強(qiáng)度等級僅檢查抗壓強(qiáng)度,導(dǎo)致砌體承載力降低。2、任意修改設(shè)計(jì)規(guī)定的砂漿品種,導(dǎo)致砌體強(qiáng)度或耐久性降低。3、砌筑砂漿強(qiáng)度達(dá)不到國家標(biāo)準(zhǔn)的規(guī)定。4、水平灰縫不平直、不飽滿。砂漿飽滿度小于80%。5、磚墻臨時(shí)間斷處留槎做法不符合要求,應(yīng)留設(shè)的拉結(jié)筋漏放。6、砌體組砌方法
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 中級社會(huì)工作者社保政策試題及答案
- 深刻理解2025年系統(tǒng)分析師考試難點(diǎn)試題及答案
- 系統(tǒng)集成項(xiàng)目管理最常用方法試題及答案
- 創(chuàng)新型系統(tǒng)集成試題及答案
- 黑龍江書法藝考試題及答案
- 中級社會(huì)工作者職場心理調(diào)適試題及答案
- 系統(tǒng)分析師考試專題試題及答案
- 軟件評測師對于項(xiàng)目管理的影響力試題及答案
- 備考2025年多媒體應(yīng)用設(shè)計(jì)師的題型及答案
- 軟件測試過程中的數(shù)據(jù)保護(hù)與隱私策略試題及答案
- T/CATCM 032-2024中藥配方顆粒臨床使用指南
- 摩根斯丹利-2025中國汽車綜述 China Autos Overview -2025-05
- 兒童健康管理中心運(yùn)營方案
- 2025年壓縮機(jī)用平衡塊項(xiàng)目市場調(diào)查研究報(bào)告
- 渣漿泵市場現(xiàn)狀分析及前景預(yù)測報(bào)告
- 2025年健康監(jiān)測考試試題及答案詳解
- 2025年(第一季度)電網(wǎng)工程設(shè)備材料信息參考價(jià)(加密)
- 門窗安裝勞動(dòng)合同協(xié)議
- 項(xiàng)目上市居間合同協(xié)議
- GA/T 751-2024公安視頻圖像屏幕顯示信息疊加規(guī)范
- 課題申報(bào)書:公費(fèi)師范生本研銜接培養(yǎng)研究
評論
0/150
提交評論