四川大學(xué)華西醫(yī)院醫(yī)技樓工程監(jiān)理細(xì)則xx工程監(jiān)理細(xì)則PAGE72PAGE74xx工程監(jiān)理細(xì)則PAGE1目錄第一章工程概況··············································································02第二章監(jiān)理控制的依據(jù)···································································05第三章監(jiān)理工作目標(biāo)值···································································07第四章監(jiān)理工作流程·······································································08第五章深基坑施工監(jiān)理工作要點····················································24第一節(jié)深基坑降水工程·····································································24第二節(jié)深基坑支護工程·····································································35第三節(jié)深基坑開挖工程·····································································48第四節(jié)深基坑監(jiān)測控制要點·····························································65第六章深基坑施工的監(jiān)理工作方法和措施·····································69第一章工程概況一、工程設(shè)計單位基坑支護工程設(shè)計單位:xx勘測工程公司工程設(shè)計單位:中國建筑xx有限公司二、工程勘察單位四川xx工程有限責(zé)任公司三、設(shè)計技術(shù)要求根據(jù)業(yè)主提供的四川大學(xué)華西醫(yī)院醫(yī)技樓總平面布置圖可知,本工程為單棟5層建筑,設(shè)2層地下室。擬采用全現(xiàn)澆砼框架結(jié)構(gòu),工程總建筑面積9653.22平方米,其中地上建筑面積6170.45平方米,地下建筑面積3482.77平方米。該工程設(shè)計標(biāo)高±0.000相當(dāng)于絕對高程500.05米,自然地坪標(biāo)高為500.75,室內(nèi)外地坪高差最小為0.25米。擬開挖基坑在平面上為一不規(guī)則梯形,基底面積1329.17平方米,分為AB、BC、CD、DA四段(詳見施工方案附圖),其中CD、DA段接一期已建成地下室,AB段開挖深度約本工程基坑降水深度最深處為-13m,共設(shè)降水井10口,間距約18m井深為22.5m?;禹敿t線以內(nèi)或開挖邊線外開挖深度1倍范圍(本工程為11—12m)地面應(yīng)采用厚度為20cm的C20砼硬化,并沿周邊設(shè)置截水溝(由總包單位完成)。根據(jù)設(shè)計成果,本工程采用錨拉樁+網(wǎng)噴支護,樁徑1.2m,樁長AB段19.8m,BC段樁長21.6m,共設(shè)錨拉樁52根,樁采用旋挖成孔工藝。本工程共設(shè)錨索52根,錨索設(shè)在樁上,長18m,設(shè)在基坑頂部以下-5.0m處。錨索預(yù)應(yīng)力值為300KN,AB段自由段長度為6.5m,錨固段為11.5m,下錨角度為15°;BC段自由段長度為7m,錨固段為11.0m,下錨角度為20°。樁頂設(shè)800*1200/1500冠梁,冠梁上預(yù)埋80PVC管用于臨邊圍護立管搭設(shè),間距1000*1000。四、巖土工程地質(zhì)及水文條件勘探深度內(nèi),場地地層從上至下依次為:第四系全新統(tǒng)人工填土層(Q4ml)和第四系全新統(tǒng)沖洪積層(Q4al+pl)。地勘試驗得知:1、場地內(nèi)人工填土分布連續(xù)、結(jié)構(gòu)紊亂、均勻性差、承載力低,粉質(zhì)粘土、細(xì)砂具有一定承載力,在建筑場地范圍內(nèi)均屬被挖之列;2、場地卵石土分布連續(xù),厚度較大,卵石土層主要為松散卵石、稍密卵石、中密卵石和密實卵石層,局部地段卵石層中分布有呈透鏡體狀的細(xì)砂,稍密及其以上密實度卵石土層均具較高承載力,為場地良好的天然地基土。本建筑采用鋼筋混凝土柱下獨立基礎(chǔ)及筏板基礎(chǔ),以中密卵石層作基礎(chǔ)持力層,承載力特征值fak=600KPa,持力層埋深-4.0m~-8.5m?;A(chǔ)開挖至設(shè)計標(biāo)高后,若為密實卵石層則以密石卵石層為基礎(chǔ)持力層;若未到持力層:當(dāng)超挖深度不大于0.50米時,應(yīng)繼續(xù)下挖至持力層,并以C15素混凝土回填至基底標(biāo)高;當(dāng)超挖深度大于0.50該建筑場地地貌單一,場地內(nèi)及其附近無影響工程穩(wěn)定性的不良地質(zhì)作用,屬穩(wěn)定場地,適宜建筑。場地地基土對混凝土結(jié)構(gòu)具微腐蝕性,地下水對鋼筋混凝土結(jié)構(gòu)中鋼筋具微腐蝕性。該場地處于非地質(zhì)構(gòu)造斷裂帶,可不采用防氡工程措施。地下水埋深約4.3m。場地內(nèi)地下水主要存于砂卵石中的孔隙潛水,受大氣降水、地下水徑流補給,水位隨季節(jié)改變而變化。地下水位年變幅約1—2m左右,場地地下水歷史最高水位為497.50m。砂卵石滲透性較強,富水性較好,滲透系數(shù)K約25m/天。本場地回填土層局部較厚,抗剪強度低;場地內(nèi)局部地段分布有粉土及軟弱中細(xì)砂層,自然狀態(tài)下處于不穩(wěn)定狀態(tài),基坑邊坡自身穩(wěn)定性差。由于本場地地下水位較高,基坑開挖降水時涌水量較大,本工程基坑開挖成敗的一個關(guān)鍵在于降水施工。五、專業(yè)工程特點(一)基坑周邊環(huán)境狀況該基坑場地西側(cè)為桓侯巷,為城市次要道路,路寬約9m,道路邊緣距離基坑開挖線最近距離為6m,該道路為四川大學(xué)華西醫(yī)院地下停車場主要出口,白天車流量較大,晚上車流量非常小。該道路為本基坑工程的一般危險源。道路西北側(cè)為6F磚混住宅樓,基礎(chǔ)埋深約2m,條形基礎(chǔ),距離基坑最近距離為20m。道路兩側(cè)分布有高壓電線及通訊線路(電樁)等,線路離地高度為5—7m不等,電樁地下埋置深度為1m,基坑外側(cè)道路分布有城市排污管道,距離基坑最近距離約2m。該建筑及管道為本基坑工程的次要危險源。場地北側(cè)為高度為80m的高層建筑,基坑埋置深度為12m,與本工程基底高度基本一致,本基坑工程施工對該建筑不會造成影響。場地北側(cè)有一棟4F磚混結(jié)構(gòu)建筑,基礎(chǔ)埋深約2m,條形基礎(chǔ),該建筑為60年代老建筑,建筑結(jié)構(gòu)極差,建筑物經(jīng)2008年汶川大地震后,墻體裂縫較多,多處構(gòu)造柱斷裂并有后期結(jié)構(gòu)補強的痕跡。原有墻體裂縫大部分已被抹灰隱蔽。該建筑距離基坑最近距離為6m。該建筑為本基坑工程的重大危險源,施工時應(yīng)加強對該建筑物的監(jiān)測,同時每天派專人對該建筑物進行巡視,每天巡視不少于3次。場地東側(cè)和南側(cè)為華西醫(yī)院一期地下室,地下室2層,埋深12m,本工程地下室擬與該地下室相連,該地段不需進行基坑支護,其對本基坑工程施工不會造成影響。(二)基坑工程安全等級該基坑工程周邊環(huán)境條件較復(fù)雜,基坑破壞后果嚴(yán)重,基坑一般開挖深度10.80m;場地工程地質(zhì)條件較復(fù)雜,地下水位高,對施工影響較嚴(yán)重。根據(jù)《成都地區(qū)建筑地基基礎(chǔ)設(shè)計規(guī)范》(DB51/T5026—2001)第11.5條和表11.5.3、表11.5.4,綜合確定本工程基坑安全等級為一級,基坑側(cè)壁重要性系數(shù)為1.1。第二章監(jiān)理控制的依據(jù)一、工程合同文件:承包合同文件和委托監(jiān)理合同文件。二、設(shè)計文件:“按圖施工”是施工階段質(zhì)量控制的一項重要原則,基抗支護、降水設(shè)計圖紙及巖土工程勘察報告必須經(jīng)過審查,并且有準(zhǔn)用證。三、國家及政府有關(guān)部門頒布的有關(guān)質(zhì)量管理方面的法律法規(guī)性文件(一)《中華人民共和國建筑法》(1997年(二)《建設(shè)工程質(zhì)量管理條例》(2000年(三)《建筑業(yè)企業(yè)資質(zhì)管理規(guī)定》(2001年4月頒布);四、有關(guān)質(zhì)量檢驗與控制的專門技術(shù)法規(guī)性文件(一)《建筑工程施工質(zhì)量驗收統(tǒng)一標(biāo)準(zhǔn)》GB50300-2001;(二)《建筑地基基礎(chǔ)工程施工質(zhì)量驗收規(guī)范》GB50202-2002;(三)《建筑樁基技術(shù)規(guī)范》JGJ94-2008;(四)《建筑基樁檢測技術(shù)規(guī)范》JGJ106-2003;(五)《混凝土結(jié)構(gòu)工程施工質(zhì)量驗收規(guī)范(2011版)》GB50204-2002;(六)《建筑地基基礎(chǔ)設(shè)計規(guī)范》GB50007-2011;(七)《建筑基坑支護技術(shù)規(guī)程》JGJ120-2012;(八)《建筑變形測量規(guī)程》(JGJ8-2007)(九)《工程測量規(guī)范》GB50026-2007;(十)《建筑工程地質(zhì)勘探與取樣技術(shù)規(guī)程》JGJ/T8-2012;(十一)《基坑土釘支護技術(shù)規(guī)范》CECS96:97;(十二)《錨桿噴射混凝土支護技術(shù)規(guī)范》GB50086-2001;(十三)《混凝土泵送施工技術(shù)規(guī)程》JGJ/T10-2011;(十四)《建筑地基處理技術(shù)規(guī)范》JGJ79-2012;(十五)《土方與爆破工程施工及驗收規(guī)范》(GB50201-2012);(十六)《建筑與市政降水工程技術(shù)規(guī)范》(JGJ/T111-98);(十七)控制施工作業(yè)活動質(zhì)量的技術(shù)規(guī)程、電焊操作規(guī)程、混凝土施工操作規(guī)程。(十八)已批準(zhǔn)的本工程《監(jiān)理規(guī)劃》。第三章監(jiān)理工作目標(biāo)值一、工程項目監(jiān)理工作目標(biāo)監(jiān)理工作目標(biāo)主要是加強工程質(zhì)量、安全和進度的控制管理,同時達(dá)到合同約定的其它工作目標(biāo)。二、工期控制目標(biāo)嚴(yán)格控制在經(jīng)審批的該基坑工程的施工進度計劃工期內(nèi)。三、投資控制目標(biāo)以該深基坑工程土方施工承包合同價作為控制目標(biāo),不突破此投資。四、安全文明控制目標(biāo)按施工承包合同的約定,嚴(yán)格執(zhí)行國家建設(shè)工程施工有關(guān)現(xiàn)行安全法律法規(guī)制度及安全操作規(guī)程,積極消除施工安全隱患,杜絕重傷和死亡安全事故。按省市有關(guān)文明施工現(xiàn)場標(biāo)準(zhǔn)進行檢查和控制。五、質(zhì)量控制目標(biāo)嚴(yán)格貫徹執(zhí)行國家有關(guān)工程質(zhì)量的法律法規(guī)以及設(shè)計文件,按國家建筑工程施工質(zhì)量驗收統(tǒng)一標(biāo)準(zhǔn)進行檢查和驗收,加強工程施工過程質(zhì)量控制,各分項分部工程必須合格。第四章監(jiān)理工作流程一、工程質(zhì)量控制流程審批開工申請、下達(dá)開工令審批開工申請、下達(dá)開工令承包單位申報施工方案承包單位申報材料合格證、復(fù)驗單加倍復(fù)試或換材料監(jiān)理審批不合格修改不合格合格分部、分項工程施工施工試驗及監(jiān)理取樣各分項、隱蔽工程自檢填報工程報驗單監(jiān)理工程師現(xiàn)場檢查及審查試驗報告簽發(fā)工程檢驗認(rèn)可書并在自檢資料上簽字下一道工序施工分部工程完成填寫分部工程報驗承包單位現(xiàn)場檢查監(jiān)理工程師內(nèi)業(yè)資料檢查監(jiān)理工程師檢查結(jié)果分項(隱蔽)工程報驗單和分項工程檢驗認(rèn)可書附附:①隱檢單②預(yù)檢單③質(zhì)量保證資料④分項工程質(zhì)量評定表不合格修改不合格簽改不合格簽改合格監(jiān)理工程師簽發(fā)分部工程檢驗認(rèn)可書二、安全監(jiān)理工作流程圖施工單位報審安全文明施工方案(JL—A001)不合格監(jiān)理單位施工單位報審安全文明施工方案(JL—A001)不合格監(jiān)理單位建設(shè)單位工程開工準(zhǔn)備符合相應(yīng)工程項目建設(shè)強制性標(biāo)準(zhǔn)符合相應(yīng)工程項目建設(shè)強制性標(biāo)準(zhǔn)監(jiān)理單位審核開工報告、安全文明施工方案監(jiān)理單位審核開工報告、安全文明施工方案建設(shè)單位認(rèn)可安監(jiān)站建設(shè)單位認(rèn)可安監(jiān)站建設(shè)單位驗收安全文明開工條件建設(shè)單位驗收安全文明開工條件發(fā)布開工令總監(jiān)簽發(fā)建設(shè)單位發(fā)布開工令總監(jiān)簽發(fā)建設(shè)單位易發(fā)生重大事故部位、環(huán)節(jié)重點監(jiān)控現(xiàn)場監(jiān)理人員施工全過程安全巡視、檢查現(xiàn)場監(jiān)理工程師易發(fā)生重大事故部位、環(huán)節(jié)重點監(jiān)控現(xiàn)場監(jiān)理人員施工全過程安全巡視、檢查現(xiàn)場監(jiān)理工程師監(jiān)理口頭指令存在問題監(jiān)理口頭指令存在問題檢查結(jié)果監(jiān)理工程師檢查結(jié)果監(jiān)理工程師安全問題指令安全問題指令總監(jiān)理工程師總監(jiān)理工程師監(jiān)理通知單安全事故(報業(yè)主、公司、上級主管部門)嚴(yán)重安全隱患(報業(yè)主)監(jiān)理通知單安全事故(報業(yè)主、公司、上級主管部門)嚴(yán)重安全隱患(報業(yè)主)監(jiān)理工程師(總監(jiān)審簽)總監(jiān)簽發(fā)暫停施工令監(jiān)理工程師(總監(jiān)審簽)總監(jiān)簽發(fā)暫停施工令參與調(diào)查處理對安全問題進行處理參與調(diào)查處理對安全問題進行處理整改復(fù)查報審承包單位總監(jiān)、監(jiān)理工程師承包單位整改復(fù)查報審承包單位總監(jiān)、監(jiān)理工程師承包單位執(zhí)行工程質(zhì)量事故處理程序復(fù)工申請執(zhí)行工程質(zhì)量事故處理程序復(fù)工申請監(jiān)理工程師復(fù)查意見監(jiān)督處理方案實施監(jiān)理工程師監(jiān)理工程師復(fù)查意見監(jiān)督處理方案實施監(jiān)理工程師合格不合格監(jiān)理工程師監(jiān)理工程師復(fù)查處理結(jié)果合格不合格監(jiān)理工程師監(jiān)理工程師復(fù)查處理結(jié)果繼續(xù)施工合格繼續(xù)施工合格不合格復(fù)工指令總監(jiān)簽發(fā)不合格復(fù)工指令總監(jiān)簽發(fā)三、工程投資控制程序簽定施工合同簽定施工合同業(yè)主、承包、監(jiān)理三方施工圖紙會審設(shè)計、承包、業(yè)主、監(jiān)理工程預(yù)付款申請承包單位施工圖紙實施承包單位材料設(shè)備采購業(yè)主、監(jiān)理、承包單位聯(lián)合考查廠家材料、設(shè)備等審核預(yù)付款申請監(jiān)理工程師總監(jiān)理工程師核準(zhǔn)承包單位審核認(rèn)可申請監(jiān)理工程師索賠申請承包單位索賠審批監(jiān)理工程師總監(jiān)理工程師承包單位審核計量監(jiān)理工程師鑒認(rèn)付款證書總監(jiān)理工程師承包單位審核申請監(jiān)理工程師否不成立否報送業(yè)主付款監(jiān)理單位否否否否否否否否四、五、六、七、分包單位資質(zhì)審查基本程序選擇分包單位承包單位填報《分包單位資質(zhì)報審表》監(jiān)理工程師審查簽認(rèn)審查意見同意不同意

同意不同意承包單位與分包單位簽訂施工分包合同分包單位進場施工八、發(fā)生須暫停施工的情況總監(jiān)理工程師簽發(fā)《工程暫停令》施工單位暫停部分施工發(fā)生須暫停施工的情況總監(jiān)理工程師簽發(fā)《工程暫停令》施工單位暫停部分施工消除工程暫停的因素消除工程暫停的因素具備復(fù)工條件,總監(jiān)理工程師應(yīng)要求施工單位及時填寫《工程復(fù)工報審表》,并審核簽認(rèn)具備復(fù)工條件,施工單位填寫總監(jiān)理工程師審核簽認(rèn)施工單位繼續(xù)施工九、工程延期管理基本程序延期事件發(fā)生延期事件發(fā)生項目監(jiān)理部收集資料詳細(xì)記錄過程承包單位提交工期索賠意向報告承包單位隨時提交延期事件的詳細(xì)報告延期事件結(jié)束、承包單位提交《工程延期申請表》監(jiān)理工程師審核與評估總監(jiān)理工程師與承包單位、建設(shè)單位協(xié)商總監(jiān)理工程師簽發(fā)《工程延期審批表》不同意同意一致不一十、工程進度款支付程序施工單位申報當(dāng)月完成工作量報表及下月工程進度計劃施工單位申報當(dāng)月完成工作量報表及下月工程進度計劃專業(yè)監(jiān)理工程師審查報表完成工程形象進度及工程質(zhì)量情況會同施工單位現(xiàn)場計量核實工程量專業(yè)監(jiān)理工程師簽署初審意見總監(jiān)理工程師審查確認(rèn)簽署支付審批表業(yè)主同意支付拒付十一、工程質(zhì)量事故處理程序發(fā)生工程質(zhì)量事故發(fā)生工程質(zhì)量事故發(fā)出《工程暫停令》要求施工單位保護現(xiàn)場,采取必要措施防止事故擴大要求事故發(fā)生單位按事故分類和等級向相應(yīng)級別主管部門上報,24H內(nèi)寫出書面報告應(yīng)邀參加或協(xié)助事故調(diào)查組工作。與監(jiān)理方責(zé)任有關(guān)時應(yīng)回避研究調(diào)查組的技術(shù)處理意見監(jiān)督施工單位實施技術(shù)處理方案施工單位自檢和專業(yè)檢驗后報驗組織檢查、鑒定、驗收簽認(rèn)事故單位提交的質(zhì)量事故處理報告、組織技術(shù)資料歸檔發(fā)出《工程復(fù)工令》繼續(xù)施工國家或地方相應(yīng)級別主管部門組織成立調(diào)查組現(xiàn)場調(diào)查取證事故原因分析組織必要的技術(shù)鑒定提出技術(shù)處理意見及防止類似事故再次發(fā)生的措施調(diào)查結(jié)束10日內(nèi)寫出調(diào)查報告行政執(zhí)法處理建議事故單位提交質(zhì)量事故處理報告行政處罰不處理十二、工程材料、構(gòu)配件質(zhì)量控制流程承包單位填報承包單位填報“材料(構(gòu)配件)、設(shè)備進場使用報驗單”審核質(zhì)量保證資料到廠家考察審核質(zhì)量保證資料到廠家考察必要的抽檢試驗報建設(shè)單位審批承包單位另選承包單位另選另報不合格監(jiān)理工程師審核不合格監(jiān)理工程師審核合格合格產(chǎn)品進場、承包單位檢查驗收并進標(biāo)示產(chǎn)品進場、承包單位檢查驗收并進標(biāo)示建設(shè)單位批準(zhǔn)承包單位采購合格的材料建設(shè)單位批準(zhǔn)承包單位采購合格的材料合格合格不合格清退出場不合格清退出場監(jiān)理工程師對進場材料進行抽檢并核查質(zhì)量保證書、見證取樣送檢監(jiān)理工程師對進場材料進行抽檢并核查質(zhì)量保證書、見證取樣送檢監(jiān)理工程師審查簽認(rèn)、同意使用監(jiān)理工程師審查簽認(rèn)、同意使用十三、工程測量質(zhì)量控制流程承包單位報送測量儀器及檢定證書監(jiān)理工程師檢查檢定證書承包單位報送測量儀器及檢定證書監(jiān)理工程師檢查檢定證書通知承包單位將儀器、鋼尺送計量器具鑒定部門鑒定無通知承包單位將儀器、鋼尺送計量器具鑒定部門鑒定無有承包單位校測基準(zhǔn)點、水準(zhǔn)點有承包單位校測基準(zhǔn)點、水準(zhǔn)點監(jiān)理人員復(fù)核控制基準(zhǔn)點、水準(zhǔn)點監(jiān)理人員復(fù)核控制基準(zhǔn)點、水準(zhǔn)點建筑物定位、放線及復(fù)核建筑物定位、放線及復(fù)核監(jiān)理工程師審核施工測量控制網(wǎng)方案 監(jiān)理工程師審核施工測量控制網(wǎng)方案不同意不同意承包單位重新修改方案監(jiān)理工程師監(jiān)測施工測量控制網(wǎng)承包單位制定施工測量控制網(wǎng)方案審核結(jié)果承包單位重新修改方案監(jiān)理工程師監(jiān)測施工測量控制網(wǎng)承包單位制定施工測量控制網(wǎng)方案審核結(jié)果同意同意承包單位測設(shè)施工測量控制網(wǎng)承包單位測設(shè)施工測量控制網(wǎng)不合格不合格監(jiān)測結(jié)果承包單位重新測設(shè)控制網(wǎng)監(jiān)測結(jié)果承包單位重新測設(shè)控制網(wǎng)合格合格檢查結(jié)果檢查結(jié)果十四、鋼筋工程質(zhì)量控制流程承包單位提報鋼材進場使用報驗單監(jiān)理工程師審查驗收、見證取樣送檢承包單位提報鋼材進場使用報驗單監(jiān)理工程師審查驗收、見證取樣送檢承包單位重新采購、重新報驗不合格承包單位重新采購、重新報驗不合格檢驗結(jié)果合格檢驗結(jié)果合格進場掛牌堆放;鋼筋加工制作進場掛牌堆放;鋼筋加工制作承包單位檢查鋼筋制作質(zhì)量檢查鋼筋制作質(zhì)量監(jiān)理工程師檢查焊工上崗證:試焊監(jiān)理工程師檢查焊工上崗證:試焊監(jiān)理工程師檢查鋼筋焊接情況:取樣送檢承包單位、監(jiān)理工程師焊接返工檢查鋼筋焊接情況:取樣送檢承包單位、監(jiān)理工程師焊接返工承包單位不合格不合格結(jié)果合格結(jié)果合格返工或整改承包單位返工或整改承包單位鋼筋綁扎、預(yù)埋件驗收承包單位、監(jiān)理工程師不合格不合格驗收結(jié)果驗收結(jié)果合格合格簽署隱蔽工程驗收單簽署隱蔽工程驗收單監(jiān)理工程師十五、模板工程質(zhì)量控制流程簽認(rèn)、同意進入下道工序監(jiān)理工程師驗收結(jié)果合格整改至合格,重新報驗承包單位模板體系驗收監(jiān)理工程師支撐系統(tǒng)、模板的安裝、校正及自檢承包單位審批模板工程施工方案監(jiān)理工程師簽認(rèn)、同意進入下道工序監(jiān)理工程師驗收結(jié)果合格整改至合格,重新報驗承包單位模板體系驗收監(jiān)理工程師支撐系統(tǒng)、模板的安裝、校正及自檢承包單位審批模板工程施工方案監(jiān)理工程師軸線、標(biāo)高、截面的驗收軸線、標(biāo)高、截面的驗收監(jiān)理工程師整改、重新報驗承包單位整改、重新報驗承包單位不合格驗收結(jié)果不合格驗收結(jié)果合格合格不合格不合格十六、混凝土工程質(zhì)量控制流程原材料準(zhǔn)備、檢驗承包單位、監(jiān)理工程師原材料準(zhǔn)備、檢驗承包單位、監(jiān)理工程師施工機具準(zhǔn)備檢查承包單位、監(jiān)理工程師混凝土配合比試驗、審核承包單位、監(jiān)理工程師混凝土配合比試驗、審核承包單位、監(jiān)理工程師熟悉圖紙、審查施工方案監(jiān)理工程師返工承包單位隱檢情況不合格返工承包單位隱檢情況不合格合格合格混凝土攪拌、運輸、澆搗、養(yǎng)護混凝土攪拌、運輸、澆搗、養(yǎng)護承包單位拆模:檢查混凝土質(zhì)量拆模:檢查混凝土質(zhì)量承包單位、監(jiān)理工程師缺陷修補承包單位有旁站監(jiān)理監(jiān)理人員缺陷修補承包單位有旁站監(jiān)理監(jiān)理人員缺陷無無簽認(rèn)工序質(zhì)量報驗單監(jiān)理工程師簽認(rèn)工序質(zhì)量報驗單監(jiān)理工程師進入下道工序進入下道工序承包單位第五章深基坑施工監(jiān)理工作要點第一節(jié)深基坑降水工程一、施工降水程序設(shè)計降水井形式→編制降水施工方案→組織專家論證→方案報送監(jiān)理項目部審批→布孔→鉆機就位→埋護壁管→沖擊成孔→撈渣換漿→下井管→填礫→洗井(活塞與空壓機聯(lián)合洗井)→交驗→放置水泵→所有降水井施工完畢后降水→組織排水直至達(dá)到降水要求。二、降水主要參數(shù)1、基坑降水深度最深處為-13m,共設(shè)置降水井10口,間距約18m,鉆頭直徑500mm,成孔直徑600mm,井深為22.5m。布設(shè)2個沉砂池。2、降水井井管結(jié)構(gòu):(0~12.5m)為井壁管,(12.5~20m)為纏絲濾水管,(20~22.5m)為盲管,填濾料4~8mm礫石。3、基坑頂紅線以內(nèi)或開挖邊線外開挖深度1倍范圍內(nèi)(本工程為11~12m)地面應(yīng)采用厚度為200mm的C20砼硬化,并沿周邊設(shè)置截水溝。三、監(jiān)理預(yù)控1、熟悉設(shè)計圖紙(1)總監(jiān)理工程師、各駐地監(jiān)理工程師及各專業(yè)監(jiān)理工程師參加降水方案論證會,悉心聽取專家意見,為降水施工監(jiān)理做好技術(shù)準(zhǔn)備;(2)施工前參加設(shè)計交底會及圖紙會審;(3)各駐地監(jiān)理工程師及各專業(yè)監(jiān)理工程師根據(jù)工程實際情況詳細(xì)對照設(shè)計圖紙,完成閱圖工作。2、確定質(zhì)量控制點(1)控制降水井井深;(2)控制洗井質(zhì)量,做到水清沙凈;(3)控制泥漿參數(shù);(4)控制井管質(zhì)量;(5)建筑物、構(gòu)筑物的監(jiān)控量測。3、審查分包單位分包條件(1)審查分包單位分包資質(zhì)、業(yè)績、安全生產(chǎn)許可證;(2)審查總、分包單位安全協(xié)議;(3)審查分包單位人員資質(zhì)、持證上崗情況、機械設(shè)備運轉(zhuǎn)情況;(4)審查分包合同的簽訂。對不能滿足本工程施工質(zhì)量、進度要求的,應(yīng)及早向建設(shè)單位匯報情況,提出意見,避免延誤工期。4、審查施工方案(1)審查施工方案審批手續(xù)的完整、有效性。承包人的項目經(jīng)理部編制的施工方案應(yīng)經(jīng)承包人的技術(shù)負(fù)責(zé)人審查簽認(rèn),并在規(guī)定的時間內(nèi)填報“施工組織設(shè)計(方案)報審表”報監(jiān)理機構(gòu)審批。(2)審查施工方案的主要內(nèi)容必須滿足規(guī)范要求(從人、機、料、法、環(huán)五個因素審查其正確性、完整性)。eq\o\ac(○,1)人力和機具的資源配備必須滿足工程施工和工程進度的需求;eq\o\ac(○,2)審核對不同地層的地下水的處理方式:在有相對不透水層存時,對于存在于透水層中的地下水如何進行處理,而且不影響基坑的正常施工,確?;觽?cè)壁的穩(wěn)定。eq\o\ac(○,3)施工方法的選擇必須和施工環(huán)境相匹配,降水井鉆孔、填濾料、洗井、抽水施工工藝必須滿足環(huán)境保護要求;eq\o\ac(○,4)施工質(zhì)量標(biāo)準(zhǔn)和質(zhì)量保證措施必須滿足工程質(zhì)量目標(biāo)。(3)審查施工單位的安全施工和環(huán)保管理措施必須合理、完善。施工前由駐地安全監(jiān)理工程師審查施工單位上報的施工方案中有關(guān)安全施工和環(huán)保管理措施,提出建議和意見。安全施工和環(huán)保管理措施不符合施工有關(guān)規(guī)定或措施不到位,不能滿足施工相關(guān)要求時返回施工單位修改后再報;駐地安全監(jiān)理工程師初審合格后由總監(jiān)辦安全監(jiān)理工程師審查,提出建議和意見。經(jīng)總監(jiān)辦安全監(jiān)理工程師審查,安全施工和環(huán)保管理措施不符合施工有關(guān)規(guī)定或措施不到位,不能滿足施工相關(guān)要求時返回施工單位修改后再報;安全施工和環(huán)保管理措施經(jīng)監(jiān)理審查合格后方可進行降水工程施工。四、施工過程的監(jiān)理控制1、審查進場的原材料、構(gòu)配件、設(shè)備。(1)需要控制的原材料種類(名稱)eq\o\ac(○,1)濾料:填入降水井的濾料應(yīng)潔凈,符合設(shè)計要求,其規(guī)格為含水層篩分粒徑d50的5~10倍。eq\o\ac(○,2)井管:檢查生產(chǎn)廠家的資質(zhì),在此基礎(chǔ)上審查井管的出廠合格證,重點是管壁的孔隙是否滿足設(shè)計要求,另外要檢查管身的結(jié)構(gòu)質(zhì)量,主要是檢查井管在裝卸過程有無碰裂,一般用敲擊聽的方法可以檢查。若采用薄閉鋼管,除應(yīng)檢查管壁的孔隙是否滿足設(shè)計要求外,還應(yīng)檢查管身的焊接質(zhì)量。濾水管孔隙率,鋼管應(yīng)不小于10%,無砂水泥管應(yīng)不小于15%,檢查方法為檢查出廠合格證。目視管井井壁無破損,管井直徑允許偏差為-20mm。檢查方法為尺量。(2)需要控制的進場機械設(shè)備反循環(huán)鉆機、SH-30套管鉆機、空氣壓縮機、潛水泵。檢查方法為檢查機械設(shè)備出廠合格證,試運轉(zhuǎn)機械設(shè)備,確保機械設(shè)備狀況良好。(3)確定做復(fù)試及見證取樣的材料品種、數(shù)量及其合格標(biāo)準(zhǔn)。濾料含泥量應(yīng)不大于3%,濾料級配應(yīng)符合設(shè)計要求。檢查方法為抽樣送檢。(4)不合格品的處理。檢驗檢查原材料、機械設(shè)備不合格的,要求將不合格原材料、機械設(shè)備清除出場,重新進場合格原材料并重新報驗。2、檢查人員、機具、作業(yè)環(huán)境的落實。(1)檢查管理人員的資格。檢查承包單位、分包單位的項目經(jīng)理部管理人員的崗位設(shè)臵、人員資格、數(shù)量必須與施工方案一致;(2)檢查操作人員資格。操作人員的工種、數(shù)量必須與施工方案一致,特殊工種人員必須持證上崗;(3)檢查所投入的施工工具。所投入的施工工具滿足施工方案計劃及工程需要,正常運轉(zhuǎn),無安全隱患;(4)施工作業(yè)環(huán)境及作業(yè)條件符合規(guī)范要求。以上檢查各項內(nèi)容如不符合要求,應(yīng)下發(fā)監(jiān)理指令并督促承包單位改正。3、降水井施工主要操作工藝的控制要點及措施。(1)井位、數(shù)量與孔徑eq\o\ac(○,1)井位、數(shù)量要求a.井位施放時要求施工單位必須詳細(xì)調(diào)查核實場區(qū)地下管線分布情況,當(dāng)無法確定時可采用人工開孔的方法,當(dāng)確認(rèn)地下無各種管線后方可施工。b.為避開各種障礙物,降水井間距可作局部調(diào)整,但間距最大不應(yīng)超過井間距120%,且降水井總量不得減少。不宜與設(shè)計井位相差太大,如因特殊情況,需要移位井必須與設(shè)計溝通,取得設(shè)計同意后,寫出書面意見、說明原因,報監(jiān)理批準(zhǔn)后實施。c.開挖施工前,降水井的布設(shè)應(yīng)已形成封閉。d.對于明挖基坑,降水井施工放樣時,要選擇在圍護樁之間,避免錨索施工時破壞降水井或使降水井被水泥漿液填堵失效。eq\o\ac(○,2)井身結(jié)構(gòu)誤差要求a.井徑誤差±20mm;b.垂直度誤差≤1%;c.井深應(yīng)滿足設(shè)計要求。(2)成孔選用的泥漿濃度從施工角度講特別希望用比較濃的泥漿,以免發(fā)生塌孔,對于砂層或砂礫石層地層更是如此,但是從成井的質(zhì)量看,砂層或砂礫石地層正好是透水地層,是須要降水的地層,如果泥漿濃度太大,將會堵塞砂層或砂礫石層中的孔隙,影響降水效果,即使洗井,其效果也不是很理想。因此,成井過程中監(jiān)理必須控制泥漿的濃度。(3)下管前,要檢查管底座是否有裂紋,是否完整,底座與管身結(jié)合完好情況,要檢查設(shè)計要求放濾網(wǎng)的位置,施工單位是不是按設(shè)計要求的規(guī)格安放濾網(wǎng)。下管時,要注意井管不能與井壁直接接觸,待濾料填完后,才能解除臨時固定。(4)填料要求檢查放入孔壁的濾料是不是符合設(shè)計要求:eq\o\ac(○,1)含水層段礫料應(yīng)具有一定的磨圓度,礫料含泥量(含石粉)≤3%,粒徑4~8mm;eq\o\ac(○,2)要避免填料速度過快或不均造成濾管偏移及濾料在孔內(nèi)架橋現(xiàn)象,洗井后濾料下沉應(yīng)及時補充濾料,要求實際填料量不小于95%理論計算量。放濾料時,應(yīng)先臨時封閉管口,避免濾料填入管內(nèi),不能用翻斗車直接往里倒,應(yīng)用人工往里填,在距地面1.0~1.5m范圍內(nèi)井壁外應(yīng)用黏土填實。填濾料時應(yīng)檢查濾料是否接近設(shè)計填料量,如果填料量遠(yuǎn)大于設(shè)計填料量,可能是井管破了,該井報廢應(yīng)補井。(5)洗井要求洗井、井管安放好并在井壁外填完濾料后,應(yīng)立即進行洗井,成井-洗井間隔時間不能超過7小時。洗井要求按設(shè)計要求或相應(yīng)規(guī)范要求進行控制。采用隔離塞分段洗井,如果泥漿中含泥砂量較大,可先進行撈渣,再進行洗井。洗井要求達(dá)到“水清砂凈”,當(dāng)常規(guī)洗井效果不好時,可加洗井劑浸泡后再洗井。4、降水井使用主要操作工藝的控制要點及措施。(1)井口處理基坑開挖過程中,基坑內(nèi)疏干井隨土方開挖進度逐節(jié)拆除。挖土過程中要求施工單位嚴(yán)禁機械挖掘降水井周圍1.0m范圍內(nèi)土體,人工拆卸井管,防止井管內(nèi)落入雜物。(2)水泵安裝eq\o\ac(○,1)檢查放入井內(nèi)的水泵出廠廠家的資質(zhì)及產(chǎn)品質(zhì)量合格證,檢查水泵的銘牌、抽水量、揚程,并應(yīng)用萬能表檢查水泵的線路有無損壞。eq\o\ac(○,2)降水工程水泵全部采用吊泵法安裝。eq\o\ac(○,3)水泵泵管采用聚乙管,管井與水泵出水口直徑相吻合。下泵前泵管與水泵連接牢固,采用鋼絲繩或鉛絲綁牢水泵,用鋼絲繩或雙鉛絲吊放水泵至井底,提起2.0m后用井字架固定與井口。eq\o\ac(○,4)檢查水泵放入的位置是不是符合設(shè)計要求。eq\o\ac(○,5)水泵安裝過程中嚴(yán)禁直接拖放泵管。(3)抽水要求eq\o\ac(○,1)試抽水:抽水設(shè)備安裝好后,應(yīng)進行抽水試驗,檢查是否有漏氣現(xiàn)象,并做好抽水壓力,水位,抽水量記錄。檢查單井水泵工作壓力,抽水量,水位記錄,核查抽水量及水位下降值是否達(dá)到設(shè)計要求。eq\o\ac(○,2)抽水試驗穩(wěn)定標(biāo)準(zhǔn)A出水量,水位沒有持續(xù)上升或下降的變化趨勢。B抽水井動水位波動值不超過過水位降深1%,空壓機抽水水位波動值不超過10~20cm。C出水量波動值不超過正常出水量的5%。eq\o\ac(○,3)抽水含砂量控制:為防止因抽地下水帶出地層細(xì)顆粒物質(zhì)造成地面沉降,抽出的水含砂量必須保證:粗砂含量<1/5萬;中砂含量<1/2萬;細(xì)砂含量<1/1萬。eq\o\ac(○,4)首次(洗井后抽水前)含砂量檢測合格后,按設(shè)計要求的井?dāng)?shù)進行運行,在抽水期間間隔時間不超過3個月定期進行含砂量檢測,異常情況下應(yīng)根據(jù)情況加密檢測次數(shù)。各井聯(lián)合運行時,將會有大量的地下水被抽至地面,應(yīng)檢查排水措施的布置,主要是總排水管管經(jīng)、坡度,匯集的水必須排至遠(yuǎn)離基坑,以防滲入基坑內(nèi),并且應(yīng)排至城市污水系統(tǒng)。通過觀測井,檢查基坑最深處的地下水位是不是降到基坑底以下0.5~1.0m以下。eq\o\ac(○,5)開挖至地下水位標(biāo)高前的超前抽水時間不少于20天。eq\o\ac(○,6)降水井系統(tǒng)檢查A當(dāng)各個井點安裝完畢,應(yīng)進行整體試抽水,以檢查水、電、管網(wǎng)系統(tǒng)是否達(dá)到要求。B承包方抽水階段應(yīng)對井口進行封閉,并設(shè)立警示,要安排專人值班抽水,直至降水施工完成,保證降水連續(xù)進行,同時做好水位觀測記錄,及時分析降水效果,調(diào)整抽水井的布局和水泵工作壓力,確保達(dá)到基坑降水的預(yù)期目的。C降水井工程終結(jié)后承包方要發(fā)以文、圖、表并舉的方式,總結(jié)施工成果并及時反饋監(jiān)理。(4)降水期地下水觀測及建筑物、構(gòu)筑物監(jiān)測eq\o\ac(○,1)降水期應(yīng)對地下水動態(tài)進行觀測,并對地下水動態(tài)變化進行及時分析;eq\o\ac(○,2)當(dāng)?shù)叵滤患眲∽兓瘧?yīng)及時分析原因(如水泵損壞、地下含水構(gòu)筑物突然破裂漏水或區(qū)域地下水位上升等)。eq\o\ac(○,3)按《建筑施工測量監(jiān)理》對地上地下建筑物、構(gòu)筑物進行監(jiān)控量測,要按體系的要求進行相應(yīng)報警,并進行相應(yīng)的處理。五、降水工程施工及使用中應(yīng)注意的問題1、基坑施工過程中的排水問題檢查(1)基坑側(cè)壁滲水措施檢查;(2)基坑底部積水處理措施檢查2、基坑降水對周邊環(huán)境影響的檢查(1)對降水基坑周邊地下管線的影響,降水往往會導(dǎo)致地面沉降,如果沉降過大,會導(dǎo)致地下管線斷裂,如果是上、下水管線斷裂將會對基坑穩(wěn)定造成嚴(yán)重的后果,必須防范,避免此類事件的發(fā)生,要求施工單位必須有切實可行的措施。(2)對基坑周邊已有建筑物的影響,在基坑深度兩倍范圍內(nèi),如有建筑物,特別是重要建筑物,施工單位必須分析由于基坑降水對其影響程度,并進行原有建筑物安全穩(wěn)定評價。如果影響比較大,必須采取切實可行的措施,并組織專家論證會,在專家們的評價采取的措施可行后方可進行降水工作,否則決不允許進行降水工作。3、降水效果的檢查施工單位應(yīng)有專人,每天定時對降水井水位進行觀察,對每口降水井建立出水量記錄臺帳,通過與基坑側(cè)壁觀察結(jié)果的比較,檢查抽水影響半徑和降水情況,綜合判定降水效果,預(yù)計基坑內(nèi)剩余水量。對不能或部分不能達(dá)到降水預(yù)期效果的,應(yīng)及時論證,與設(shè)計單位溝通,變更降水方案,保證工程質(zhì)量、安全、進度。4、要檢查基坑周邊上、下水或污水管線向基坑內(nèi)滲水情況首先應(yīng)要求施工單位在基坑開挖前必須核實基坑周邊上、下水或污水管線的布置情況。由于已完成的下水管線或污水管線有可能存在漏水現(xiàn)象,因此施工單位在查清基坑周邊下水管布置情況后,必須制定相應(yīng)的措施,予以防范其對基坑穩(wěn)定的影響,根據(jù)具體情況修改原方案,同時應(yīng)向設(shè)計單位和監(jiān)理報告,以便設(shè)計單位重新對基坑邊坡土的物理力量指標(biāo)重新進行評價,必要時應(yīng)修改邊坡支護方案。5、大氣降水的排水措施檢查基坑在施工過程中,大氣降水是不可避免的,一方面要檢查基坑內(nèi)排水措施是不是到位,另外要檢查基坑上口邊是不是有攔水措施,嚴(yán)防基坑外的降水或生活生產(chǎn)用水流向基坑內(nèi)。六、降水工程施工質(zhì)量驗收1、降水工程施工質(zhì)量驗收的基本規(guī)定(1)降水與排水是配合基坑開挖的安全措施,施工前應(yīng)有降水與排水設(shè)計。當(dāng)基坑降水時,應(yīng)有降水影響范圍的估算,對周邊重要建筑物或公共建筑物進行降水過程中的監(jiān)測。(2)降水系統(tǒng)施工后,應(yīng)先進行試運轉(zhuǎn),如果發(fā)現(xiàn)井管失效,應(yīng)采取措施使其恢復(fù)正常,如無法恢復(fù)則應(yīng)報廢處理,另行設(shè)置新的井管。(3)降水系統(tǒng)運行中,應(yīng)隨時檢查觀測降水井中的水位。(4)基坑內(nèi)明排水應(yīng)設(shè)置排水溝及降水井,排水溝縱坡宜控制在1‰~2‰。2、降水與排水施工質(zhì)量檢驗標(biāo)準(zhǔn)序檢查項目允許偏差或允許值檢查方法單位數(shù)值1排水溝坡度‰1~2目測:坑內(nèi)不積水,溝內(nèi)排水暢通2井管(點)垂直度%1插管時目測3井管(點)間距(與設(shè)計相比)%≤150用鋼尺量4井管(點)插入深度(與設(shè)計相比)mm≤200水準(zhǔn)儀5過濾砂礫料填灌(與計算值相比)mm≤5檢查回填料用量6井點真空度:輕型井點噴射井點kPakPa>60>93真空度表真空度表7電滲井點陰陽極距離:輕型井點噴射井點mmmm80~100120~150用鋼尺量用鋼尺量3、形成的監(jiān)理資料(1)監(jiān)理工作記錄eq\o\ac(○,1)監(jiān)理通知;eq\o\ac(○,2)監(jiān)理通知回復(fù)單;eq\o\ac(○,3)工作聯(lián)系單;eq\o\ac(○,4)不合格項處理記錄。(2)監(jiān)理驗收資料eq\o\ac(○,1)隱蔽工程驗收記錄;eq\o\ac(○,2)檢驗批驗收資料;eq\o\ac(○,3)分項工程質(zhì)量檢驗評定表;eq\o\ac(○,4)隱蔽/分項工程報驗單。第二節(jié)深基坑支護工程一、支護工程特點1、支護形式本工程采用錨拉樁+網(wǎng)噴支護,樁徑1.2m,樁長AB段19.8m,BC段21.6m,樁距2.0m,共設(shè)錨拉樁52根,樁采用旋挖成孔工藝;本工程共設(shè)錨索52根,錨索設(shè)在樁上,長18m,設(shè)在基坑頂部以下-5.0m處;樁頂設(shè)800*1200/1500冠梁,冠梁上預(yù)埋80PVC管用于臨邊圍護立管搭設(shè),間距1000*1000。2、支護結(jié)構(gòu)施工說明(1)支護結(jié)構(gòu)鋼筋保護層厚度為50mm,樁芯和冠梁砼強度分別為C30、C25,樁頂冠梁強度達(dá)到設(shè)計強度的70%方可進行樁邊6m范圍內(nèi)的土方開挖。樁身主筋通長筋全部錨入冠梁。(2)樁體砼應(yīng)連續(xù)灌注。(3)每根樁打入錨索位置需縱向加4根(前、后各2根)間距為170mm,直徑為22的通長筋,橫向加兩根間距為170mm,直徑為22的加強箍筋。使其在錨索施工時對護壁樁的破壞縮小,樁體更加穩(wěn)固。(4)工況1完成后,進入工況2施工前,需在各護壁樁嵌入錨索位置,整修一個大小為320*320的平面。使其在錨索施加預(yù)應(yīng)力時錨墊板與樁體緊貼,受力面積增大錨索張拉更加穩(wěn)定。(5)樁間采用掛直徑8,間距200的鋼筋網(wǎng),網(wǎng)筋外鋪設(shè)加強筋直徑14,間距2000,樁間支護主筋與樁身通過植筋進行連接(植筋深度15d)。樁間鋪設(shè)C20細(xì)石砼,厚度80,上層砼面層達(dá)到設(shè)計強度的70%后方可進行下層土方開挖。泄水孔徑50mm,梅花形2*2.5m.(6)護壁體系頂?shù)孛嬗庙欧忾]至紅線圍墻,有條件時應(yīng)砼封閉2倍基坑深度地面范圍。(7)錨索緊箍環(huán)及架線環(huán)可用定型產(chǎn)品代替,但必須保證尺寸適中,保證錨桿在孔內(nèi)居中。錨固段架線環(huán)與緊箍環(huán)每隔1.00m間隔設(shè)置;自由段每隔2m設(shè)置一道架線環(huán)以保證鋼絞線順直。(8)設(shè)置導(dǎo)向帽為保證錨桿順利下錨,導(dǎo)向帽可采用直徑8鋼筋彎折焊接并用8號鐵絲繞制。(9)錨固體強度達(dá)到設(shè)計強度的70%后方可張拉鎖定并進行下層土方開挖。3、基坑監(jiān)測(1)鉆空灌注樁施工完成后,采用低應(yīng)變動測法監(jiān)測樁身完整性,檢測數(shù)量不宜少于總樁數(shù)的10%,且不得少于5根。(2)鉆孔灌注樁當(dāng)根據(jù)低應(yīng)變動測法判定的樁身缺陷可能影響樁的水平承載力時,應(yīng)采用鉆芯法補充檢測,檢測數(shù)量不宜少于總樁數(shù)的2%,且不得少于3根。二、基坑支護監(jiān)理控制點及目標(biāo)值1、對施工程序的控制(1)鉆孔灌注樁控制點測放→測放樁位→埋設(shè)護筒→復(fù)核樁位→樁機就位→樁機成孔→一次清孔→吊放鋼筋籠→下導(dǎo)管→二次清孔→澆灌混凝土。(2)冠梁土方開挖至梁底標(biāo)高→鑿樁頭→測量放線→鋼筋制安→側(cè)模安裝→砼澆筑→砼養(yǎng)護→拆模。(3)樁間護壁基坑開挖至第一層加強筋標(biāo)高→修整壁面→噴射第一層砼(30mm)到一定強度→鋪設(shè)鋼筋網(wǎng)及主筋(主筋植入樁體)→噴射砼并養(yǎng)護至設(shè)計強度70%→挖土至下層加強筋施工深度→重復(fù)以上工作直至基底設(shè)計標(biāo)高以上300mm,采用人工撿低至設(shè)計標(biāo)高。(4)錨索錨孔定位編號→鉆機就位→造孔→清孔→探孔→桿體(預(yù)應(yīng)力筋)的組裝與安放(含注漿管)→注漿→設(shè)置錨墩→張拉鎖定→封孔注漿→外錨頭保護。2、監(jiān)理控制要點(1)要十分重視地質(zhì)勘察工作。監(jiān)理工程師要認(rèn)真閱讀工程的地質(zhì)勘察報告,了解基坑開挖所在地的地形、地貌和地質(zhì)特點,分析可能導(dǎo)致邊坡土體滑坡的各種因素,對影響邊坡穩(wěn)定性的關(guān)鍵地段、重要地層和土質(zhì)指標(biāo)做到心中有數(shù)。由于地質(zhì)勘察資料不一定很詳細(xì),而且可能與實際情況有出入,監(jiān)理工程師在基坑開挖中還要經(jīng)常對比現(xiàn)場的地質(zhì)情況,與地質(zhì)報告差異很大時要及時告知建設(shè)單位,由建設(shè)單位通知勘察和設(shè)計單位,查看是否需要調(diào)整方案。(2)鉆孔灌注樁施工eq\o\ac(○,1)鉆孔灌注樁質(zhì)量控制點設(shè)置表項質(zhì)量控制點質(zhì)量預(yù)控措施1樁位認(rèn)真復(fù)核原始基準(zhǔn)點,確定建筑物軸線后,根據(jù)支護設(shè)計中支護樁與建筑軸線的關(guān)系進行支護樁放線,建立控制性樁,便于施工過程中對樁位進行復(fù)查,碰到障礙物時先進行障礙物處理再放線。監(jiān)理工程師要檢查施工單位測量儀器、測量人員證件,組織測量監(jiān)理工程師復(fù)核施工承包單位的放線結(jié)果并確認(rèn)。2鉆孔灌注樁施工順序鉆孔灌注樁應(yīng)間隔施工,兩臺鉆機同時施工要間隔三個以上的樁位,以免出現(xiàn)竄孔情況。樁身混凝土澆注完畢24小時后方可施工相鄰的樁。3鋼筋籠制作鋼筋籠分段制作,分段長度應(yīng)按成籠的整體剛度、來料鋼筋長度及起重設(shè)備的有效高度等因素確定??v向主筋連接必須采用焊接,焊接質(zhì)量要特別注意,同一截面的接頭數(shù)量不得大于縱筋數(shù)量的50%,且相鄰接頭的間距不小于35d?;\外側(cè)必須有保證鋼筋砼保護層的措施(50mm厚保護層,設(shè)3組墊塊,每組不少于3塊,可采用砼滑輪塊或扁鋼定位體)。4樁成孔垂直度觀測調(diào)整鉆機的水平度和鉆桿的垂直度,檢查起重滑輪邊緣,固定鉆桿的管孔和護筒三者是否在一軸線上,發(fā)現(xiàn)鉆桿不正常地擺晃或難于鉆進時,應(yīng)立即提鉆檢查,排除地下塊石或障礙物,遇硬地層應(yīng)慢速鉆進,在鉆進過程中采取減壓鉆進,以避免和減少斜孔、彎曲和擴孔等現(xiàn)象。5樁身砼澆灌成孔后對成孔質(zhì)量認(rèn)真檢查,泥漿比重應(yīng)小于1.25(排出),沉渣不宜大于200mm(護坡樁放寬標(biāo)準(zhǔn)要求);鋼筋的安放要嚴(yán)格控制籠頂高程;導(dǎo)管口距孔底不大于500mm,初次剪球后,導(dǎo)管埋入砼的深度不小于800mm;砼的坍落度為18~20cm,每50m3或每組日留置一組砼試件,現(xiàn)場養(yǎng)護。要嚴(yán)格控制浮籠、導(dǎo)管撥出砼面或埋深不夠(一般控制在2~6m)、斷樁、夾泥等現(xiàn)象發(fā)生;水下砼必須連續(xù)施工,每根樁的澆注時間按初盤砼的初凝時間控制,一般不超86高程嚴(yán)格控制樁頂砼高程,澆灌砼時,砼面高出設(shè)計高程500mm(不含浮漿),保證與冠梁的連接,嚴(yán)格控制鋼筋籠頂高度。項序檢查項目允許偏差或允許值檢查方法主控項目1主筋間距±10用鋼尺量2長度±100用鋼尺量一般項目1鋼筋材質(zhì)檢驗設(shè)計要求抽樣送檢2箍筋間距±20用鋼尺量3直徑±10用鋼尺量eq\o\ac(○,2)砼灌注樁鋼筋籠質(zhì)量檢驗標(biāo)準(zhǔn)(mm)eq\o\ac(○,3)砼灌注樁質(zhì)量檢驗標(biāo)準(zhǔn)項序檢查項目允許偏差或允許值檢查方法檢驗程度單位數(shù)值主控項目1樁位mm50開挖后量樁中心全部檢查2孔深mm+300只深不淺,用測繩吊重錘測。全部檢查3樁體質(zhì)量檢驗按基樁檢測技術(shù)規(guī)范及設(shè)計要求。如鉆芯取樣,或采用可靠的低應(yīng)變動測法。按基樁檢測技術(shù)規(guī)范或《深基坑技術(shù)規(guī)定》DB42/159-1998抽樣檢查4混凝土強度設(shè)計要求試件報告或鉆芯取樣送檢抽樣檢查5承載力一般項目1垂直度小于1%測鉆桿全部檢查2樁徑±50井徑儀或超聲波檢測全部檢查3泥漿雙重1.15~1.20全部檢查4泥漿面標(biāo)高m0.5-1.0目測全部檢查5沉渣厚度mm≤150用沉渣儀或重錘測量全部檢查6mm160~220坍落度儀全部檢查7mm±100用鋼尺量全部檢查8>1全部檢查9樁頂標(biāo)高mm+30-50水準(zhǔn)儀,需扣除樁頂浮漿層及劣質(zhì)樁體全部檢查(3)冠梁施工eq\o\ac(○,1)鑿樁頭:鑿除樁頂浮漿及多余樁身砼,并剔除樁主筋上殘余砼,保證主筋伸入冠梁的長度滿足設(shè)計要求。如不能滿足要求,可焊接同規(guī)格、強度等級的鋼筋。鋼筋焊接長度:雙面焊5d,單面焊10d。eq\o\ac(○,2)安裝側(cè)模按照《土建監(jiān)理細(xì)則》(六、模板工程施工監(jiān)理)執(zhí)行。eq\o\ac(○,3)鋼筋安裝按照《土建監(jiān)理細(xì)則》(七、鋼筋工程施工監(jiān)理)執(zhí)行。eq\o\ac(○,4)PVC管預(yù)埋鋼筋綁扎完成后,冠梁上預(yù)埋∮80PVC管用于臨邊圍護立管搭設(shè),間距1000*1000。eq\o\ac(○,5)砼澆筑、養(yǎng)護,拆除模板。按照《土建監(jiān)理細(xì)則》(八、混凝土工程施工監(jiān)理)執(zhí)行。(4)樁間護壁施工eq\o\ac(○,1)噴錨支護質(zhì)量控制點設(shè)置表質(zhì)量控制點質(zhì)量預(yù)控措施1分段分片根據(jù)護壁樁的排數(shù)分段,同一段內(nèi)應(yīng)自下而上進噴射。2植筋樁間支護主筋與樁身通過植筋進行連接(植筋深度15d)。3安放鋼筋網(wǎng)片鋼筋網(wǎng)片在噴射一層砼后鋪設(shè),鋼筋與坡面的間距宜大于30mm,鋼筋網(wǎng)片通過加強筋與護壁樁連結(jié)牢固,鋼筋網(wǎng)綁扎的搭接長度不得小于30d。4噴射砼射流應(yīng)垂直噴射面,射距為0.8~1.5m;噴射時噴頭處的工作風(fēng)壓以保持在0.10~0.12Mpa為宜;噴射砼的水灰比為0.4~0.45,砂率宜為45%~55%,石子粒徑不大于15mm,水泥與砂石的重量比窒為1:4~1:5;二次噴射前應(yīng)清除面層上的浮漿和松散碎屑,并噴水使之濕潤;噴射砼終凝2h后,應(yīng)噴水養(yǎng)護,養(yǎng)護時間宜為3~7d;噴射砼的強度為C20,土釘墻砼強度為C15。eq\o\ac(○,2)噴錨支護工程質(zhì)量檢驗標(biāo)準(zhǔn)項序檢查項目允許偏差或允許值檢查方法檢驗程度單位數(shù)值主控項目1錨桿土釘長度mm±30用鋼尺量全部檢查2錨桿鎖定力設(shè)計要求現(xiàn)場實測抽樣檢查一般項目1mm±100用鋼尺量全部檢查2鉆孔傾斜度±1測機頭深度全部檢查3漿體強度設(shè)計要求試樣送檢抽樣檢查4注漿量大于理論計算漿量檢查計算數(shù)據(jù)全部檢查5土釘墻面厚度mm±10用鋼尺量抽樣檢查6試樣送檢抽樣檢查(5)錨索施工eq\o\ac(○,1)土方開挖至錨索位置后,對錨索位置進行復(fù)核,施工前嚴(yán)格檢查鉆具軸線方位角及傾角,使鉆孔方向及傾角滿足設(shè)計要求。eq\o\ac(○,2)錨孔基本參數(shù)錨索根據(jù)設(shè)計圖準(zhǔn)確定位,鉆孔中心偏差≯20mm;孔斜誤差≯1%;鉆孔傾斜誤差≯1°;錨孔孔徑參數(shù):孔徑為150mm;孔深18.0m,嚴(yán)格控制有效孔深:+△L≮50cm。eq\o\ac(○,3)鉆孔應(yīng)勻速鉆進,嚴(yán)格控制鉆孔速度,保證鉆孔鉛直和孔徑一致;錨孔采用風(fēng)動旋轉(zhuǎn)壓力式跟管鉆進成孔工藝,錨索下入鉆孔后方可拔出套管。eq\o\ac(○,4)鋼絞線下料后應(yīng)除油、除銹,保持鋼絞線清潔。制作好的鋼絞線束應(yīng)堆放在架管搭設(shè)的支架上,不得直接放置在地面上。對制作好的錨索進行分類和編號,注明鉆孔編號,避免混淆。eq\o\ac(○,5)制作完成的錨索與注漿管一起放入錨索孔中,下錨時應(yīng)保持錨索順直,勻速、緩慢的送入孔內(nèi)。下錨遇到阻力時,不得強行加力貫入,應(yīng)將錨索適當(dāng)回拔再送入,反復(fù)多次仍不能下放時,應(yīng)查找原因,必要時取出錨索,采用空壓機重新清孔。eq\o\ac(○,6)錨索安裝完成后,壓力注漿前,應(yīng)再次采用高風(fēng)壓清孔。一次攪拌的水泥漿應(yīng)在初凝以前用完。eq\o\ac(○,7)注漿方法為孔底注漿法,注入的水泥漿自孔底逐漸返回孔口,自孔口溢出后停止注漿,初凝后進行孔口補漿。注漿過程中嚴(yán)格按配合比計量,攪拌均勻并過濾。嚴(yán)格控制注漿壓力(為2Mpa),并對基坑壁變形進行觀測,如發(fā)現(xiàn)有向基坑內(nèi)變形跡象應(yīng)立即停止施工并上報業(yè)主、監(jiān)理和設(shè)計。eq\o\ac(○,8)注漿開始或中途停止超過30min時,應(yīng)用水或稀水泥漿潤滑灌漿泵和注漿導(dǎo)管。在注漿完畢后或距下一次注漿時間較長時,應(yīng)及時將注漿管線清洗干凈。砂漿硬化后未能充滿錨孔時,應(yīng)進行二次補漿并封孔,二次注漿在注漿體強度達(dá)到3~5Mpa時進行。eq\o\ac(○,9)注漿后在水泥(砂)漿強度達(dá)到設(shè)計強度的80%,砼強度達(dá)到70%時,方可進行錨索張拉。錨索張拉工作沿支護樁逐段進行,以保證支護樁受力均勻。張拉時應(yīng)加強路基和墻體的變形觀測,發(fā)現(xiàn)問題及時上報。錨索張拉按相關(guān)規(guī)范進行。三、監(jiān)理工作方法及措施1、施工單位進場后監(jiān)理審查施工單位企業(yè)資質(zhì)等有關(guān)資料和質(zhì)保體系、安保體系是否健全。(1)審查施工單位企業(yè)資質(zhì)等有關(guān)資料eq\o\ac(○,1)施工企業(yè)資質(zhì)等級證書、建設(shè)工程施工許可證、企業(yè)法人營業(yè)執(zhí)照、企業(yè)安全生產(chǎn)許可證;eq\o\ac(○,2)項目經(jīng)理及主要管理人員、技術(shù)人員、專職質(zhì)檢員、安全員、施工員的上崗證書;eq\o\ac(○,3)特殊工種(電焊工、電工、樁機操作工等)的上崗證;eq\o\ac(○,4)檢測儀器、工具的標(biāo)定證書;eq\o\ac(○,5)施工組織設(shè)計、基坑專項施工方案、基坑監(jiān)測專項方案、施工現(xiàn)場臨時用電方案等;eq\o\ac(○,6)質(zhì)量安全監(jiān)督站辦理質(zhì)量監(jiān)督手續(xù)、安全監(jiān)督手續(xù)、安檢手續(xù)等證明資料;eq\o\ac(○,7)開工報告等(2)檢查施工單位質(zhì)保體系、安保體系是否健全。eq\o\ac(○,1)施工單位質(zhì)保體系、安保體系組織機構(gòu)落實情況;eq\o\ac(○,2)施工單位質(zhì)保體系主要規(guī)章制度;3)施工單位安保體系主要規(guī)章制度。2、進行技術(shù)、質(zhì)量、安全交底,嚴(yán)格按圖施工,按規(guī)范施工。3、嚴(yán)格材料成品的審核報驗手續(xù),嚴(yán)禁任何不合格品用于本工程。機械設(shè)備所用電纜應(yīng)完好,嚴(yán)防漏電、觸電事件發(fā)生。4、加強對施工過程的巡視、檢查、驗收,發(fā)現(xiàn)問題及時解決。四、質(zhì)量控制與檢查驗收深基坑支護質(zhì)量控制可根據(jù)不同階段分為事前控制、事中控制和事后驗收。1、事前控制(1)由總監(jiān)理工程師組織監(jiān)理人員認(rèn)真熟悉圖紙和地質(zhì)報告,掌握支護樁、噴射混凝土、支撐梁和冠梁、降水井、大面積土方開挖特點,做到心中有數(shù),并對圖紙中存在的問題通過建設(shè)單位向設(shè)計單位提出書面意見。(2)施工前參加建設(shè)單位組織的設(shè)計交底會,解決圖紙中存在的有關(guān)問題,總監(jiān)理工程師對技術(shù)交底會議紀(jì)要進行簽認(rèn)。(3)審查施工單位上報的施工組織設(shè)計和施工方案,同時還應(yīng)審查施工單位是否編制應(yīng)急預(yù)案。審查重點:a.保證工程質(zhì)量和安全的技術(shù)措施;b.施工機械、設(shè)備的配備和樁機、鉆機的性能、型號合理與否;c.測量放線的方法及保證樁位精度的措施;d.以上各工藝施工流程的安排;e.施工計劃安排和保證工期的措施;f.質(zhì)量標(biāo)準(zhǔn)。(4)施工前由總監(jiān)理工程師組織審查施工單位的現(xiàn)場管理機構(gòu)的質(zhì)量管理體系、技術(shù)管理體系并予以確認(rèn)。(5)專業(yè)監(jiān)理工程師做好定位放線復(fù)核工作:全站儀、水準(zhǔn)儀、經(jīng)緯儀、測距儀等測量設(shè)備應(yīng)通過計量部門標(biāo)定并滿足施工測量精度要求,應(yīng)在建筑物主要軸線外圍引出永久性控制點和高程點,該建筑工程設(shè)計標(biāo)高±0.000相當(dāng)于絕對高程500.05米(6)施工前由施工單位檢查進場樁機機械性能以及設(shè)備完好情況,鉆孔樁導(dǎo)管的打壓試驗,錨桿的基本試驗,降水井的試抽水,混凝土、灌漿料的配合比等,以保證施工要求。(7)了解鉆孔樁現(xiàn)場附近的地下管線等市政設(shè)施情況,審查環(huán)境保護措施及施工監(jiān)測方案。(8)對進場原材料出廠合格證、質(zhì)保資料、試驗檢測報告進行核查,重要材料應(yīng)現(xiàn)場取樣送檢。(9)降水開始前,應(yīng)確認(rèn)應(yīng)急柴油發(fā)電機已到場,并確定能正常運轉(zhuǎn);柴油發(fā)電機的功率應(yīng)能滿足降水設(shè)備的要求。2、事中控制(1)深基坑支護工程是保證地下室結(jié)構(gòu)施工安全的一道重要關(guān)鍵工序,應(yīng)由專業(yè)監(jiān)理工程師組織現(xiàn)場監(jiān)理員跟班檢查、加強現(xiàn)場監(jiān)控以保證深基坑支護各工藝的施工質(zhì)量。(2)嚴(yán)格按設(shè)計方案組織施工,在施工過程中要求施工單位不得隨意改變錨索位置、長度、型號、數(shù)量,鋼筋網(wǎng)間距,加強筋范圍等。(3)監(jiān)理工程師應(yīng)對錨索位置、鉆孔直徑、深度及角度、錨索長度,注漿配比、壓力及注漿量,噴錨墻面厚度及強度,錨索應(yīng)力等進行檢查,按規(guī)定留置混凝土試塊、注漿試塊,監(jiān)理旁站錨索張拉。(4)噴射作業(yè)應(yīng)分段、分層進行,同一分段內(nèi)噴射順序應(yīng)自下而上,噴射混凝土?xí)r,噴頭與受噴面應(yīng)保持垂直,距離宜為0.6~1.0m。噴射表面應(yīng)平整,呈濕潤光澤,無干斑、流淌現(xiàn)象。噴射混凝土終凝2h后,應(yīng)噴水養(yǎng)護,養(yǎng)護時間宜為3~7h。噴射混凝土面層中的鋼筋網(wǎng)應(yīng)在噴射第一層混凝土后鋪設(shè),鋼筋網(wǎng)設(shè)加強筋與支護樁應(yīng)連接牢固。(5)放線定樁位應(yīng)從施工現(xiàn)場的測量基準(zhǔn)點施測,護筒中心應(yīng)與樁位同心,鉆機轉(zhuǎn)盤必須水平,轉(zhuǎn)盤中心、樁位中心及天輪懸吊中心應(yīng)重合,最大偏差小于5㎜。鉆孔鉆到設(shè)計深度,先清孔換漿,再進行終孔驗收。第二次清孔在下放鋼筋籠和灌注混凝土的導(dǎo)管安裝完畢后進行,驗收合格的鋼筋籠,應(yīng)掛牌及編號,以免用錯,吊裝鋼筋籠時,應(yīng)避免鋼筋籠變形,吊點應(yīng)對稱,使鋼筋籠吊起時呈鉛直狀態(tài),鋼筋籠保護層墊塊沿樁長間距2m,鋼筋籠兩節(jié)相連,焊接時要扶正、同心,主筋搭接用單面焊,焊縫應(yīng)飽滿,主筋無損傷,經(jīng)檢查驗收認(rèn)可后,才能下入孔內(nèi)。首灌量必須滿足導(dǎo)管底端埋入混凝土中1m,在每根樁的施工過程中,應(yīng)按監(jiān)理工程師要求進行記錄,填寫有關(guān)表格,一式兩份。3、事后驗收(1)審查施工單位上報的資料。深基坑支護驗收應(yīng)包括下列資料:a.經(jīng)審定的施工組織設(shè)計、施工方案及執(zhí)行中的變更情況;b.樁位測量放線圖,包括工程樁位復(fù)核驗收單;c.鉆孔灌注樁施工驗收記錄表;d.錨索鉆孔施工驗收記錄表;e.降水井施工驗收記錄表;f.噴射混凝土施工驗收記錄;g.原材料出廠合格證、質(zhì)量保證書、試驗檢測報告等。(2)對有問題的支護樁、錨索、降水井、圈梁與支撐梁、噴射混凝土的情況說明、原因分析及處理意見。(3)錨索采用抗拉試驗檢測,試驗數(shù)量為錨索總數(shù)的1%。(4)撰寫深基坑支護施工質(zhì)量評估報告。五、基坑支護監(jiān)測1、嚴(yán)格審查施工監(jiān)測方案,監(jiān)測方案必須有如下監(jiān)測內(nèi)容:地表、地下管線、道路、立柱樁及建筑物的沉降觀測,圍護墻體的測斜,圍護墻體頂部的水平位移,坑外水位監(jiān)測,支撐應(yīng)力監(jiān)測,錨索應(yīng)力監(jiān)測等。2、督促施工單位按照要求在開挖前進行布置觀測點和基準(zhǔn)點,并進行首次觀測,保存施工記錄。3、按照要求每周觀測一次,雨后必須進行觀測,觀測結(jié)果應(yīng)記錄,超出報警置時(水平位移允許值:30㎜,沉降位移允許值:30㎜)現(xiàn)場立即處理。但在基坑危險階段或某項監(jiān)測內(nèi)容處于報警狀態(tài)時,應(yīng)全天候監(jiān)測。4、按照要求在基坑開挖和基礎(chǔ)施工期間乃至到基坑回填完成期間(軟土地區(qū)尚應(yīng)延長4~6個月)均必須對影響區(qū)范圍內(nèi)的鄰近建筑物和管線垂直與水平變形進行監(jiān)測,工程結(jié)束時提交一份完整的基坑監(jiān)測報告。六、安全施工監(jiān)理1、督促施工單位制定應(yīng)急預(yù)案;2、督促施工單位每周定期、不定期組織安全檢查,發(fā)現(xiàn)安全隱患,及時整改,杜絕安全事故發(fā)生;3、督促施工單位安全負(fù)責(zé)人落實具體安全措施;4、每周工地例會應(yīng)對現(xiàn)場安全管理進行專題討論;5、督促施工單位建立和完善安全施工管理制度,組織安全文明施工;6、督促施工單位落實和完善現(xiàn)場施工安全保證體系;7、監(jiān)理每周組織一次安全檢查(臨時用電、設(shè)備安全、現(xiàn)場文明施工、基坑邊防護、夜間照明等);8、嚴(yán)格按照建設(shè)部建質(zhì)[2008]91號《建筑施工企業(yè)安全生產(chǎn)管理機構(gòu)設(shè)置及專職安全生產(chǎn)管理人員配備辦法》、建質(zhì)[2004]213號《危險性較大工程安全專項施工方案編制及專家論證審查辦法》、建質(zhì)[2003]82號《建筑工程預(yù)防高處墜落事故若干規(guī)定》和《建筑工程預(yù)防坍塌事故若干規(guī)定》等文件要求落實安全生產(chǎn);10、未盡事宜詳見《安全監(jiān)理實施細(xì)則》。第三節(jié)深基坑開挖工程一、土方工程主要參數(shù)1、擬開挖基坑在平面上為一不規(guī)則梯形,其占地面積約1669.5m2,AB段開挖深度約為11m,BC段開挖深度約為12m2、出土坡道按1:6放坡,設(shè)1道坡道。3、噴射砼大面(80mm厚C20細(xì)石砼)上分4大步開挖,每步開挖至土釘設(shè)計標(biāo)高下0.5m。上層砼面層強度到達(dá)設(shè)計強度的70%后方可進行下層土方開挖。4、機械開挖應(yīng)該離開開挖線200~400mm,基底300mm厚土體采用人工清底。5、樁頂冠梁強度達(dá)到設(shè)計強度的70%方可進行樁邊6m范圍內(nèi)的土方開挖。6、基坑監(jiān)測共設(shè)置5個水平位移監(jiān)測點,14個沉降監(jiān)測點。二、土方開挖1、臨時性挖方的邊坡值應(yīng)符合下表規(guī)定土的類別邊坡值(高:寬)砂土(不包括細(xì)砂、粉砂)1:1.25-1:1.50一般性黏土硬1:0.75-1:1.00硬、塑1:1.00-1:1.25軟1:1.50或更緩碎石類土充填堅硬、硬塑黏性土1:0.50-1:1.00充填砂土1:1.00-1:1.50注:1、設(shè)計有要求時應(yīng)符合設(shè)計標(biāo)準(zhǔn)。2、如采用降水或其他加固措施,可不受本表限制,但應(yīng)計算復(fù)核。3、開挖深度,對軟土不應(yīng)超過4m,對硬土不應(yīng)超過8m。4、本表引自《建筑地基基礎(chǔ)工程施工質(zhì)量驗收規(guī)范》(GB50202-2002)表6.2.32、土方開挖工程質(zhì)量檢驗標(biāo)準(zhǔn)應(yīng)符合下表規(guī)定土方開挖工程質(zhì)量檢驗標(biāo)準(zhǔn)項序項目允許偏差或允許值(mm)檢驗方法柱基基坑基槽挖方場地平整管溝地(路)面基層人工機械主控項目1標(biāo)高-50±30±50-50-50水準(zhǔn)儀2長度、寬度(由設(shè)計中心線向兩邊量)+200-50+300-100+500-150+100-經(jīng)緯儀,用鋼尺量3邊坡設(shè)計要求一般項目1表面平整度2020502020用2m靠尺和楔形塞尺檢查2基底土性設(shè)計要求觀察或土樣分析注:地(路)基層的偏差值適用于直接在挖、填方上做地(路)面的基層。3、土方開挖原則(1)由于錨索、噴射砼施工穿插在土方施工中,且施工和養(yǎng)護的時間較長,因此土方開挖首先為錨索、噴射砼創(chuàng)造出工作面。(2)挖掘機每步挖土開挖深度為2~2.5m時效率最高。因此,開挖時采用盆式開挖,基坑周邊向內(nèi)8m為每道錨桿施工區(qū)域,開挖時應(yīng)密切配合,中間部分落差不能超過兩步土。既保證支護體系的養(yǎng)護時間,又最大化的利用機械的效率。(3)開挖前首先探明地下障礙物,與業(yè)主和市政有關(guān)部門辦理移交手續(xù)后方可開始。(4)土方施工時嚴(yán)格控制工地?fù)P塵,采取施工時現(xiàn)場灑水,必要時覆蓋草簾被等措施;土方車輛在現(xiàn)場內(nèi)清理干凈后才能出工地大門,泥濘過多時在出大門部分道路鋪設(shè)地毯。(5)土方開挖時應(yīng)注意現(xiàn)場安全,對于落差較大的部分設(shè)置腳手架欄桿,并設(shè)專人指揮機械。以免發(fā)生滑坡。三、土方回填壓實機具壓實機具壓實機具平碾250-3006-8柴油打夯機200-2503-4振動壓實機250-3503-4人工打夯<2003-42、壓實填土的質(zhì)量控制標(biāo)準(zhǔn)結(jié)構(gòu)類型填土部位壓實系數(shù)λc控制含水量(%)砌體承重結(jié)構(gòu)和框架結(jié)構(gòu)在地基主要受力層范圍內(nèi)≥0.97ωop±2在地基主要受力層范圍以下≥0.95排架結(jié)構(gòu)在地基主要受力層范圍內(nèi)≥0.96ωop±2在地基主要受力層范圍以下≥0.94注:1、壓實系數(shù)λc為壓實填土的控制干密度ρd與最大干密度ρdmax的比值,的比值,ωop為最優(yōu)含水量;2、地坪墊層以下及基礎(chǔ)底面標(biāo)高以上的壓實填土,壓實系數(shù)不應(yīng)小于0.94。3、填土結(jié)束后,應(yīng)檢查標(biāo)高、邊坡坡度、壓實程度等,檢驗標(biāo)準(zhǔn)應(yīng)符合下表規(guī)定:項序項目允許偏差或允許值(mm)檢驗方法樁基基坑基槽場地平整管溝地(路)面基層礎(chǔ)人工機械主控項目1標(biāo)高-50±30±50-50-50水準(zhǔn)儀2分層壓實系數(shù)設(shè)計要求一般項目1回填土料設(shè)計要求2分層厚度及含水量設(shè)計要求水準(zhǔn)儀及抽驗檢查3表面平整度2020202020用靠尺或水準(zhǔn)儀四、土方工程質(zhì)量預(yù)控內(nèi)容1、組織現(xiàn)場勘查,掌握熟悉圖紙(1)了解現(xiàn)場地形、地貌、水文、地質(zhì)、地下埋設(shè)物、地上障礙物和臨近建筑。(2)了解水、電供應(yīng)、市政排水管網(wǎng)和運輸?shù)缆非闆r。(3)核算土石方工程量2、審定施工方案及土石方調(diào)配計劃的合理性(1)土石方作業(yè)方式:本工程為主樓結(jié)構(gòu)采用柱下獨立基礎(chǔ)和局部結(jié)合直線加速器房間厚墻采用墻下筏板基礎(chǔ),根據(jù)土質(zhì)情況,宜采用機械挖土。(2)場地排水:施工區(qū)域應(yīng)做臨時排水系統(tǒng)。臨時排水系統(tǒng)應(yīng)與原排水系統(tǒng)相適應(yīng),應(yīng)盡量與永久性排水設(shè)施相配合,但應(yīng)注意在使用中不得因淤泥沉積等降低永久性排水設(shè)施效率。排水系統(tǒng),如設(shè)計無要求時,場地應(yīng)向排水溝方向作成不小于2‰的坡度,臨時排水溝的縱向坡度一般不小于3‰(平坦地區(qū)不應(yīng)小于1‰)。臨時排水溝的橫斷面應(yīng)根據(jù)當(dāng)?shù)貧庀筚Y料,按施工期內(nèi)最大流量確定;邊坡坡度應(yīng)根據(jù)土質(zhì)和溝深確定,一般為1:0.7~1:1.5。臨時排水口的位置和出水口應(yīng)選擇合理,出水口應(yīng)遠(yuǎn)離建筑物或構(gòu)筑物,應(yīng)設(shè)置在低洼地點,保證排水暢通。3、檢查施工區(qū)域“三通一平”的情況基礎(chǔ)施工前應(yīng)對施工區(qū)域做全面清理,對于妨礙施工的已有建筑物和構(gòu)筑物、道路、溝渠、管線、墳?zāi)?、樹干等進行妥善處理。包括拆除、拆遷或改建遷移等清理措施。對于施工機械進入現(xiàn)場所經(jīng)過的道路、橋梁、卸車設(shè)施應(yīng)事先做好加寬、加固工作,修筑好施工臨時道路及供水、供電臨時設(shè)施。護坡樁已施工完畢且驗收合格,按方案完成了現(xiàn)場排水和降水設(shè)施。4、定位放線的驗收根據(jù)規(guī)劃部門給定的建筑紅線(樁),按設(shè)計要求坐標(biāo)和標(biāo)高確定單體建筑的實際軸線位置(中心線),并應(yīng)在軸線延長線外設(shè)置半永久或永久的控制樁,以便上層施工和各層復(fù)核檢查時使用。按設(shè)計的基礎(chǔ)大樣圖底寬加上操作位置尺寸,計算出基坑開挖寬度。按這些尺寸放線,同時將這些尺寸、標(biāo)高一一標(biāo)志的設(shè)于附近的建筑物上的龍門板上(龍門板是土方、基礎(chǔ)施工的重要設(shè)施,操作中要注意保護以保證施工和檢查驗收的需要)。五、土方工程施工質(zhì)量監(jiān)理要點1、事前控制要點土方工程事前監(jiān)理,應(yīng)首先了解工程地質(zhì)勘察報告,然后審核承包人的施工組織設(shè)計或施工方案,復(fù)查定位放線、水準(zhǔn)點和標(biāo)高是否符合設(shè)計要求和施工規(guī)范的規(guī)定。經(jīng)現(xiàn)場監(jiān)理工程師校審后認(rèn)為無誤,方可進行土方工程施工。(1)組織有關(guān)監(jiān)理人員學(xué)習(xí)相關(guān)圖紙、技術(shù)資料、施工規(guī)范和質(zhì)量標(biāo)準(zhǔn)。(2)工程項目施工前,組織相關(guān)圖紙會審。(3)基坑開挖前施工單位應(yīng)根據(jù)支護結(jié)構(gòu)形式、挖深、地質(zhì)條件、施工方法、周圍環(huán)境、工期、氣候和地面荷載等資料制定施工方案。監(jiān)理工程師審查施工方案,主要審核內(nèi)容包括:主要施工方法、質(zhì)量保證措施安全保證措施、進度計劃、機具設(shè)備計劃、勞動力使用計劃、成品保護措施等。施工方案經(jīng)監(jiān)理審批同意,并報業(yè)主批準(zhǔn)后方可實施。(4)監(jiān)理工程師審查施工組織設(shè)計,主要內(nèi)容包括:開挖機械的選定、開挖程序、機械和運輸車輛行駛路線、地面和坑內(nèi)排水措施及雨季施工措施等。(5)要求施工單位在土方工程施工前進行挖、填方的平衡計算,綜合考慮土方運距最短、運程合理和各個工程項目的合理施工順序等,做好土方平衡調(diào)配,減少重復(fù)挖運。(6)監(jiān)理工程師檢查施工單位操作人員持證上崗情況(管理人員資格證和特殊工種證件);檢查施工單位是否對操作人員進行安全技術(shù)交底及是否有辦理工種間交接驗收手續(xù)。(7)審查承包單位的管理組織機構(gòu)和現(xiàn)場質(zhì)量管理制度,協(xié)助其完善質(zhì)量保證體系。重點是檢查、考察管理人員是否定員、定崗、定職,經(jīng)驗和水平是否勝任;檢查質(zhì)量管理制度是否健全,技術(shù)交底制度、自檢與質(zhì)檢制度是否落實,要求承包單位做到開工有報告,施工有措施,技術(shù)有交底,定位有復(fù)查,材料有試驗報告,隱蔽工程有記錄,工序完成有自檢、專檢,交工有資料。(8)基坑開挖前,必須對鄰近建筑物、構(gòu)筑物、給水、排水、煤氣、電力電纜。電話電纜等地下管線進行調(diào)查,摸清它們的位置、埋設(shè)標(biāo)高?;A(chǔ)上部結(jié)構(gòu)形式,并將它們反映在基礎(chǔ)開挖施工平面圖上。當(dāng)開挖可能影響鄰近建筑物、管線安全使用時,必須有可靠措施保護。(9)基坑開挖,必須驗算邊坡穩(wěn)定,確定安全合理的土坡坡度和相應(yīng)的支護措施。(10)基坑開挖前應(yīng)檢查定位放線、排水和降低地下水位系統(tǒng),系統(tǒng)經(jīng)檢查和試運轉(zhuǎn),一切正常時方可施工。(11)基坑開挖前應(yīng)合理安排土方運輸車的行走線路及棄土場。(12)基坑開挖前應(yīng)對圍護結(jié)構(gòu)的施工質(zhì)量進行驗收,驗收合格后方可進行土方開挖。(13)監(jiān)測點的布置應(yīng)滿足監(jiān)控要求,從基坑邊緣以外1-2倍開挖深度范圍內(nèi)的需要保護物體應(yīng)作為監(jiān)控對象。(14)基坑工程監(jiān)測項目可按規(guī)范選擇。(15)位移觀測基準(zhǔn)點數(shù)量不應(yīng)少于兩點,且應(yīng)設(shè)在影響范圍以外。(16)監(jiān)測項目在基坑開挖前應(yīng)測得初始值,且不應(yīng)少于兩次。2、事中控制要點:(1)經(jīng)常復(fù)查平面位置、水平標(biāo)高和邊坡坡度等是否符合設(shè)計要求。檢查平面控制樁和水準(zhǔn)點是否準(zhǔn)確。(2)挖方的邊坡坡度及加固、排水設(shè)施斷面尺寸及標(biāo)高、平面的中線位置、填方的基底處理和分層壓實程度必須符合設(shè)計要求及質(zhì)量驗收規(guī)范的規(guī)定。(3)平整場地的挖方的位置、標(biāo)高、坡度必須符合設(shè)計要求和質(zhì)量驗收規(guī)范的規(guī)定,并檢查有無局部沉陷或過濕的地段。(4)填方、基坑的土料必須符合設(shè)計要求和驗收規(guī)范的規(guī)定。(5)基坑的土質(zhì)必須符合設(shè)計要求,并嚴(yán)禁擾動。其位置、尺寸、標(biāo)高、邊坡必須符合設(shè)計要求和質(zhì)量驗收規(guī)范的規(guī)定。(6)基坑回填土必須分層夯壓密實。取樣測定壓實后土的干土質(zhì)量密度,其合格率不應(yīng)小于90%,不合格干土質(zhì)量密度的最低值與設(shè)計值的差不應(yīng)大于80㎏/m3,且不能集中于某一區(qū)域。(7)挖土?xí)r,嚴(yán)禁放水浸泡后再開挖或回填粘土,以免造成建筑物、構(gòu)筑物的不均勻沉降。(8)經(jīng)常檢查場地排水或降水情況,防止基坑浸泡塌方、滑坡。(9)為確保大開挖后的邊坡不受雨水沖刷,減少地表水滲入土體,坡頂外1m挖排水溝,坑內(nèi)需設(shè)排水溝和集水井,用泵抽除積水。(10)土方開挖的順序、方法必須與設(shè)計工況相一致,并遵循“開槽支撐,先撐后挖,分層開挖,嚴(yán)禁基坑(槽)、管溝超挖”的原則。(11)在施工過程中基坑、管溝邊堆置土方不應(yīng)超過設(shè)計荷載。(12)對于處于基坑開挖較強影響區(qū)內(nèi)的鄰近建筑物、管線,應(yīng)由建設(shè)單位或總承包單位進行加固處理后方可開挖。(13)采用機械開挖基坑時,須保持坑底土體情況和挖土機械類型,應(yīng)按設(shè)計保留300mm土層由人工挖除鏟平。(14)本工程由于基坑深度較大應(yīng)分層開挖,以防開挖面的坡度過陡,引起土體位移、底面隆起、樁基側(cè)移等異常現(xiàn)象發(fā)生。每班停班后,機械應(yīng)停在1:1.5坡度線以外處。(15)軟土基坑必須分層均衡開挖,層高不宜超過1m。(16)基坑開挖過程中,應(yīng)采取措施防止碰撞或損傷支護結(jié)構(gòu)、降水設(shè)施、工程樁或擾動基底原狀土。(17)基坑土方施工中應(yīng)對支護結(jié)構(gòu)、周圍環(huán)境進行觀察和監(jiān)測,如發(fā)現(xiàn)異常情況應(yīng)立即停止挖土,并應(yīng)立即查清原因和采取措施方能繼續(xù)挖土。(18)基坑邊界周圍地面應(yīng)設(shè)排水溝,且應(yīng)避免漏水、滲水進入坑內(nèi);放坡開挖時,應(yīng)對坡頂、坡面、坡腳采取降排水措施。(19)施工過程中應(yīng)檢查平面位置、水平標(biāo)高、邊坡坡度、壓實度、排水、降低地下水位系統(tǒng),并隨時觀測周圍的環(huán)境變化。(20)土方開挖工程施工,應(yīng)經(jīng)常測量和校核其平面位置、水平標(biāo)高和邊坡坡度。平面控制樁和水準(zhǔn)控制點應(yīng)采取可靠的保護措施,并定期復(fù)測和檢查。(21)土方開挖工程的質(zhì)量檢驗標(biāo)準(zhǔn)應(yīng)符合規(guī)定。(22)雨季開挖土方,工作面不宜過大,應(yīng)逐段分期完成??用妗⒖拥着潘到y(tǒng)應(yīng)良好。雨季施工應(yīng)遵守國家現(xiàn)行有關(guān)標(biāo)準(zhǔn)。(23)各項目監(jiān)測的時間間隔可根據(jù)施工進程確定。當(dāng)變形超過有關(guān)標(biāo)準(zhǔn)或監(jiān)測結(jié)果變化速率較大時,應(yīng)加密觀測次數(shù)。當(dāng)有事故征兆時,應(yīng)連續(xù)監(jiān)測。(24)基坑開挖監(jiān)測過程中,應(yīng)根據(jù)設(shè)計要求提交階段性監(jiān)測結(jié)果報告。工程結(jié)束時應(yīng)提交完整的監(jiān)測報告。(25)平整場地的表面坡度應(yīng)符合設(shè)計要求,如設(shè)計無要求時,排水溝方向的坡度不應(yīng)小于2‰。平整后的場地表面應(yīng)逐點檢查。檢查點為每100-400㎡取1點,但不應(yīng)少于10點;長度、寬度和邊坡均為每20m取1點,每邊不應(yīng)少于1點。(26)基坑開挖驗收后,應(yīng)立即進行墊層和基礎(chǔ)施工,防止太陽暴曬和雨水浸刷破壞基土原狀結(jié)構(gòu)。3、土方開挖監(jiān)理控制要點(1)依據(jù)地質(zhì)勘察報告,基礎(chǔ)設(shè)計圖和深基坑支護設(shè)計圖以及《建筑地基基礎(chǔ)工程施工質(zhì)量驗收規(guī)范》GB50202-2002,審查基坑開挖的施工方案。對深基坑尤其要特別認(rèn)真檢查。(2)根據(jù)總平面圖的測量控制點和規(guī)劃紅線,監(jiān)察與復(fù)核施工單位所放的線,務(wù)求準(zhǔn)確。(3)深基坑開挖前須建議業(yè)主聘請專業(yè)隊伍對基坑支護結(jié)構(gòu)和周邊環(huán)境(道路路面、民用建筑等)進行監(jiān)測。并協(xié)助業(yè)主確定監(jiān)測隊伍、監(jiān)測項目與內(nèi)容。(4)深基坑開挖前還必須對支護結(jié)構(gòu)的質(zhì)量進行檢測,合格后方允許開挖。(5)在基坑開挖工程中,經(jīng)常巡視工地。注意如下問題:(1)軸線樁、龍門板或水平樁有無位移;(2)坑邊堆土高度、位置與范圍以及建材堆放;(3)土壁、坑底滲水現(xiàn)象;(4)地表水、雨水沖刷情況;(5)周邊地面有無裂縫;(6)有無塌方;(7)土質(zhì)異常、局部土質(zhì)松軟、古墓、古井、局部障礙物;(8)施工進度;(9)有無超挖(工程量超預(yù)算……)等;(10)施工安全(如挖土機下作業(yè)等)。(6)驗槽當(dāng)基坑開挖完成并清理好之后,在基礎(chǔ)施工前,監(jiān)理單位須組織施工單位、設(shè)計單位、建設(shè)單位、地勘

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論