版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
(高速公路隧道)
········································································
11
·······································································
22
·······································································
33
···································································
44
···································································
55
···································································
66
···································································
7
A
·········································
8A.1
···················································8A.2
···································8A.3
···················································8A.4
·····························································
8A.5
··························································9A.6
··························································9A.7
····················································
9A.8
···················································
10A.9
···················································
11A.10
···························································
12
B
·····································
13·····································································
41
主要起草人:
1 5002 2.1
500
2.22.3 2.4 2.533.1
3.2
3.3
3.4
3.5
“”“”44.1 a
c)需進(jìn)行特殊消防設(shè)計(jì)的專家評(píng)審相關(guān)材料(具有《建設(shè)工程消防設(shè)計(jì)審查驗(yàn)收管理暫行規(guī)定》e4.24.2.1
:acefhijklmn4.2.2
ac5 5.1ace5.2ac“”“”“”“”“”e5.3符合下列條件的,應(yīng)綜合評(píng)定為消防設(shè)計(jì)審查合格;不符合其中任意一項(xiàng)的,應(yīng)綜合評(píng)定為消防設(shè)a6 6.1
ac6.2
消防設(shè)計(jì)審查驗(yàn)收主管部門應(yīng)當(dāng)在事項(xiàng)辦結(jié)后一個(gè)月內(nèi)對(duì)消防設(shè)計(jì)審查業(yè)務(wù)管理和技術(shù)資料收6.3
6.4
A A.1A.1.1
A.1.2
A.1.3
A.1.4
A.2A.2.1
A.2.2
acA.3 A.3.1
A.3.2
A.3.3
A.4A.4.1
A.4.2
A.4.3
A.4.4
A.5A.5.1
aA.5.2
A.5.3
A.5.4
A.6 A.6.1
aA.6.2
aA.7A.7.1
aceA.7.2
acefA.7.3
acA.7.4
aceA.7.5
aA.7.6
A.8 A.8.1
A.8.2
aA.8.3
aceA.9A.9.1
ac)火災(zāi)報(bào)警控制器和交通區(qū)域控制單元、總線短路隔離器、火災(zāi)探測(cè)器、火災(zāi)手動(dòng)報(bào)警按鈕、火eA.9.2
aA.9.3
a)一級(jí)負(fù)荷中特別重要負(fù)荷、一、二級(jí)負(fù)荷消防電源采用自備發(fā)電機(jī)時(shí),發(fā)電機(jī)的規(guī)格、型號(hào)、cA.9.4
acA.9.5
aA.10 A.10.1
A.10.2
A.10.3
1A.1
A.1.1
消防設(shè)計(jì)專篇應(yīng)滿省建計(jì)審查驗(yàn)收工作實(shí)施細(xì)則》第B1□有
□無(wú)□符合
□不符合B2□有
□無(wú)□符合
□不符合B3□有
□無(wú)□符合
□不符合B4□有
□無(wú)□符合
□不符合A.1.2
消防設(shè)計(jì)圖紙應(yīng)滿工程編制,查驗(yàn)B5
5
□有
□無(wú)□符合
□不符合B6設(shè)工計(jì)審作細(xì)條的□有
□無(wú)□符合
□不符合A.1.3
消防設(shè)計(jì)圖紙應(yīng)按B7□有
□無(wú)□符合
□不符合A.1.4
建設(shè)單位應(yīng)按照相交消防設(shè)字、位內(nèi)B8□有
□無(wú)□符合
□不符合
B2A.2
A.2.1
根據(jù)隧道單洞長(zhǎng)度度預(yù)通量消防B9公路工程施的應(yīng)根□有
□無(wú)□符合
□不符合B10隧道設(shè)計(jì)規(guī)范
3.0.3-1
□有
□無(wú)□符合
□不符合A.2.2
審查隧道耐火等級(jí)準(zhǔn)確aB11
2h□有
□無(wú)□符合
□不符合井、耐火B(yǎng)12□有
□無(wú)□符合
□不符合c風(fēng)機(jī)耐火等級(jí)是否符合規(guī)范要B13□有
□無(wú)□符合
□不符合A.2
B14
級(jí),嵌縫材料燃燒性能不應(yīng)低于
B1□有
□無(wú)□符合
□不符合B15
□有
□無(wú)□符合
□不符合B16□有
□無(wú)□符合
□不符合3A.3
A.3.1
審查隧道和附屬用B17□有
□無(wú)□符合
B18□有
□無(wú)□符合
□不符合3A.3
A.3.2
審查隧道、附屬用建筑B19隧道、附屬用房之間的間距不應(yīng)小于
6m,單獨(dú)建造的變電“GB50016”
3.4.1
10kV
3m□有
□無(wú)□符合
□不符合A.3.3
根據(jù)建筑類別審查布置體審浸變高壓房等面積B20□有
□無(wú)□符合
□不符合B21□有
□無(wú)□符合
□不符合B22
10kV
□有
□無(wú)□符合
□不符合B23□有
□無(wú)□符合
□不符合B24□有
□無(wú)□符合
□不符合B25
7m
□有
□無(wú)□符合
□不符合B26□有
□無(wú)□符合
□不符合B27嚴(yán)寒變電暖裝有防□有
□無(wú)□符合
□不符合B28□有
□無(wú)□符合
□不符合B29□有
□無(wú)□符合
□不符合B30□有
□無(wú)□符合
□不符合4A.4
A.4.1
審查橫通道、防火溝等否符以下整、的防墻等耐火;電B31
2h
3000m時(shí),防火門耐火隔熱性、耐火完整性不應(yīng)小于
3h;防火門GB12955
□有
□無(wú)
□不符合B32及零部件應(yīng)環(huán)保、耐腐蝕;耐火極限不應(yīng)小于
2h;隧道長(zhǎng)度不小于
3000m
時(shí),耐火極限不應(yīng)小于
3h;防火卷簾各GB14102
□有
□無(wú)□符合
□不符合B33
3h□有
□無(wú)□符合
□不符合4A.4
A.4.2
審查排煙道等井道造是審查道是板、B34風(fēng)道道時(shí)火災(zāi)道結(jié)
1h□有
□無(wú)□符合
□不符合B35□有
□無(wú)□符合
□不符合B36□有
□無(wú)□符合
□不符合B37□有
□無(wú)□符合
□不符合A.4.3
審查地下機(jī)房等的防火構(gòu)造是否符合規(guī)范要審查所、房的設(shè)置是否符合規(guī)范要B38所應(yīng)門,變電為甲□有
□無(wú)□符合
□不符合B39附設(shè)在隧道內(nèi)的消防水泵房,應(yīng)采用耐火極限不低于
2h
□有
□無(wú)□符合
□不符合A.4.4
審查地面附屬用房和屋符合下內(nèi)和屋B40低于
3.00h
火隔能自閉的火門機(jī)房間分儲(chǔ)油量不1.00m3□有
□無(wú)□符合
□不符合B41能應(yīng)為
級(jí);屋頂保溫材料的燃燒性能不應(yīng)低于
B1級(jí);隧□有
□無(wú)□符合
□不符合5A.5
A.5.1
審查上、下行公路隧道之間橫通道設(shè)置的間寬度范要a限界B42
350m2m
2.5m
2019
5
□有
□無(wú)□符合
□不符合限界B43車行橫通道設(shè)置間距不應(yīng)大于
1000m;限界寬度不得小于4.5m□有
□無(wú)□符合
□不符合5A.5
A.5.2
審查隧道與其平行有)距、B44隧道與其平行導(dǎo)洞之間的橫通道設(shè)置的間距不宜大于500m
2m
2.5m□有
□無(wú)□符合
□不符合A.5.3
審查地下建筑(地、變與隧數(shù)量B45□有
□無(wú)□符合
□不符合B46□有
□無(wú)□符合
□不符合A.5.4
審查疏散門的數(shù)和開(kāi)B47□有
□無(wú)□符合
□不符合B48□有
□無(wú)□符合
□不符合6A.6
A.6.1
a防車B49□有
□無(wú)□符合
□不符合、承場(chǎng)、B50消防車道(聯(lián)絡(luò)道)凈寬度和凈空高度均不應(yīng)小于
4m;轉(zhuǎn)
12m□有
□無(wú)□符合
□不符合B51
4.5m
□有
□無(wú)□符合
□不符合A.6.2
a條件B5215m
10m□有
□無(wú)□符合
□不符合6A.6
圍及B53□有
□無(wú)□符合
□不符合B54□有
□無(wú)□符合
□不符合7A.7
A.7.1
a境條B55□有
□無(wú)□符合
□不符合B56補(bǔ)水水源不能滿足
48h
□有
□無(wú)□符合
□不符合B57
69□有
□無(wú)□符合
□不符合B58□有
□無(wú)□符合
□不符合用水災(zāi)的B59□有
□無(wú)□符合
□不符合c的水車取B60GB
50013
□有
□無(wú)□符合
□不符合)由市政給水管網(wǎng)供水的,政給B61□有
□無(wú)□符合
□不符合A.7.2
B621
2.40MPa2
1.0MPa3
動(dòng)水系統(tǒng)閥處作壓
1.60MPa
1.20MPa□有
□無(wú)□符合
□不符合7A.7
A.7.2
B631
設(shè)置高位消防水池,消防水池的有效容積應(yīng)滿足火災(zāi)延2
消防水池最低有效水位應(yīng)滿足水滅火設(shè)施最不利點(diǎn)處的3
消防水池出水管管徑應(yīng)滿足消防給水設(shè)計(jì)流量和出水要
DN1004
消防水池進(jìn)水管的管徑應(yīng)滿足
48h
DN100□有
□無(wú)□符合
□不符合B64統(tǒng)技術(shù)規(guī)范》GB
50974-2014中第5.15.5節(jié)的規(guī)定外,1
2
消防水池最低有效水位應(yīng)滿足水滅火設(shè)施最不利點(diǎn)處的3
消防水池出水管管徑應(yīng)滿足消防給水設(shè)計(jì)流量和出水要
DN1004
高位消防水箱進(jìn)水管的管徑應(yīng)滿足
8h
DN325
6
隧道小于
1000m
時(shí),高位消防水箱的有效容積應(yīng)大于12m3≥1000m
18m37
低位消防水池的有效容積應(yīng)滿足火災(zāi)延續(xù)時(shí)間內(nèi)所需消8
低位消防水池進(jìn)水管的管徑應(yīng)滿足
48h
DN100□有
□無(wú)□符合
□不符合7A.7
A.7.2
B651
2
低位消防水池的有效容積應(yīng)滿足火災(zāi)延續(xù)時(shí)間內(nèi)所需消3
低位消防水池進(jìn)水管的管徑應(yīng)滿足
48h
DN1004
消防水泵、穩(wěn)壓泵、消防水泵房應(yīng)符合《消防給水及消火栓系統(tǒng)技術(shù)規(guī)范》GB
50974-2014
5.15.3
5.55
穩(wěn)壓泵的設(shè)計(jì)流量宜按消防給水設(shè)計(jì)流量的
1%~3%
2.5L/s6
應(yīng)設(shè)置防止穩(wěn)壓泵頻繁啟停的技術(shù)措施,當(dāng)采用氣壓水□有
□無(wú)□符合
□不符合
15
300La條件火栓選型B66□有
□無(wú)□符合
□不符合B67□有
□無(wú)□符合
□不符合B68□有
□無(wú)□符合
□不符合B691
消防水池的出水管應(yīng)保證消防水池的有效容積能被全部2
消防水池應(yīng)設(shè)置就地水位顯示裝置,并應(yīng)在消防控制中3
□有
□無(wú)□符合
□不符合B701
2
3
40
米。□有
□無(wú)□符合
□不符合7A.7
)根據(jù)隧道的火災(zāi)延續(xù)時(shí)消火B(yǎng)71“JTG
D70/2-2014”
10.2.6
□有
□無(wú)□符合
□不符合c要求量、置形網(wǎng)保要求B72作壓保證能最力時(shí)□有
□無(wú)□符合
□不符合c要求量、置形網(wǎng)保要求B731
采用室外架空明管或埋深不滿足防凍要求時(shí),應(yīng)有冬季2
采用深埋時(shí),全段落管道最小管頂覆土應(yīng)在冰凍線以下0.30m3
1
□有
□無(wú)□符合
□不符合B741
2
埋地敷設(shè)時(shí)全段落管道最小管頂覆土應(yīng)至少在冰凍線以
0.30m3
4
5
隧道主干消防管道室外架空部分與直埋管道之間的豎□有
□無(wú)□符合
□不符合7A.7
重點(diǎn)、保B751
應(yīng)設(shè)隧道外橫向連通管道。相鄰隧道合并設(shè)置給水系統(tǒng)時(shí),如相鄰隧道最短間距小于或等于
50m,可只設(shè)一處隧2
雙洞隧道內(nèi)的橫向連通管道宜設(shè)置在人行橫洞專用管
1000m3
4
5
橫向連通管道處上、下游主干消防管道上和橫向連通管6
□有
□無(wú)□符合
□不符合重點(diǎn)、保B76
Y
□有
□無(wú)□符合
□不符合B77□有
□無(wú)□符合
□不符合B78□有
□無(wú)□符合
□不符合B791
2
3
50mm4
5
□有
□無(wú)□符合
□不符合B80
1015L/s
□有
□無(wú)□符合
□不符合B81
DN80□有
□無(wú)□符合
□不符合7A.7
e要求量、充實(shí)損失和流置高計(jì)算孔板水頭B82間距不應(yīng)大于
50m;單洞三車道、四車道公路隧道消火栓
40m□有
□無(wú)□符合
□不符合B83消火栓應(yīng)統(tǒng)一型號(hào)規(guī)格;消火栓栓口直徑應(yīng)為
65mm,水槍噴嘴口徑不應(yīng)小于
19mm
30m的水槍充實(shí)水柱長(zhǎng)度不應(yīng)小
10m;消火栓栓口出水壓力
0.5MPa
□有
□無(wú)□符合
□不符合B84□有
□無(wú)□符合
□不符合e要求量、充實(shí)損失和流置高計(jì)算孔板水頭B85“”□有
□無(wú)□符合
□不符合B86
GB50974-2014
□有
□無(wú)□符合
□不符合fB87內(nèi)水處和的消用帶□有
□無(wú)□符合
□不符合B88
1015L/s
□有
□無(wú)□符合
□不符合7A.7
A.7.3
消防水泵及消防泵B89□有
□無(wú)□符合
□不符合a等參B90□有
□無(wú)□符合
□不符合范要置應(yīng)B91
1.2m□有
□無(wú)□符合
□不符合范要置應(yīng)B92
1.2m□有
□無(wú)□符合
□不符合B93
10℃
5℃□有
□無(wú)□符合
□不符合c水管B94泵的應(yīng)保動(dòng)啟置點(diǎn)□有
□無(wú)□符合
□不符合B95泵的應(yīng)保不利火設(shè)
0.15MPa□有
□無(wú)□符合
□不符合B96穩(wěn)壓高壓系統(tǒng)止穩(wěn)
15
□有
□無(wú)□符合
□不符合B97□有
□無(wú)□符合
□不符合B98□有
□無(wú)□符合
□不符合A.7.4
a統(tǒng)的B99□有
□無(wú)□符合
□不符合7A.7
B100□有
□無(wú)□符合
□不符合c相關(guān)B101□有
□無(wú)□符合
□不符合B102
B1
□有
□無(wú)□符合
□不符合e容是B103□有
□無(wú)□符合
□不符合e容是B104不應(yīng)低于
IP30;與消防水泵設(shè)置在同一空間時(shí),其防護(hù)
IP55□有
□無(wú)□符合
□不符合B105水泵設(shè)置啟泵械應(yīng)
5min
□有
□無(wú)□符合
□不符合A.7.5
固定式水成膜泡沫a型是B106隧道內(nèi)固定式水成膜泡沫滅火裝置中的消防卷盤應(yīng)選用長(zhǎng)25m19mm
□有
□無(wú)□符合
□不符合括的供給B107固定式水成膜泡沫滅火裝置的泡沫混合液流量不應(yīng)小于30L/min連續(xù)時(shí)間小于
20min射程小于6m□有
□無(wú)□符合
□不符合A.7.6
其他消防滅火設(shè)施審查)等材的設(shè)計(jì)是否符合規(guī)范要B108“”□有
□無(wú)□符合
□不符合B109
ABC
□有
□無(wú)□符合
□不符合8A.8
A.8.1
長(zhǎng)度斷面坡、件、等因統(tǒng)的B110
5kg
8kg□有
□無(wú)□符合
□不符合B111應(yīng)大于
50m;單洞三車道及以上車道的隧道應(yīng)在隧道兩側(cè)
40m□有
□無(wú)□符合
□不符合B112
2
“”□有
□無(wú)□符合
□不符合B113□有
□無(wú)□符合
□不符合A.8.1
長(zhǎng)度斷面坡、件、等因統(tǒng)的B114長(zhǎng)度
L1000m
的高速公路隧道應(yīng)設(shè)置火災(zāi)機(jī)械防煙與排□有
□無(wú)□符合
□不符合B115□有
□無(wú)□符合
□不符合B116隧道設(shè)計(jì)生避通風(fēng)□有
□無(wú)□符合
□不符合B1171
2
()3
□有
□無(wú)□符合
□不符合B118□有
□無(wú)□符合
□不符合B119□有
□無(wú)□符合
□不符合A.8.2
a式)B120□有
□無(wú)□符合
□不符合8A.8
散通設(shè)計(jì)B121專用避難疏散通道、獨(dú)立避難所的前室余壓值不應(yīng)小于30Pa,專用避難疏散通道、獨(dú)立避難所的余壓值不應(yīng)小50Pa□有
□無(wú)□符合
□不符合B122
1.2m/s
□有
□無(wú)□符合
□不符合A.8.3
a率的取值是否符合規(guī)范要B1235000m
時(shí)火災(zāi)最大熱釋放率取
≤5000m
□有
□無(wú)□符合
□不符合)采用縱向排煙的公路隧火災(zāi)范規(guī)風(fēng)速的最B124□有
□無(wú)□符合
□不符合c公路成率B125
5000m□有
□無(wú)□符合
□不符合B126□有
□無(wú)□符合
□不符合B127□有
□無(wú)□符合
□不符合B128
5060m3
6080m3
80100m3□有
□無(wú)□符合
□不符合B129□有
□無(wú)□符合
□不符合eB130□有
□無(wú)□符合
□不符合B131
250℃小于60min
250℃□有
□無(wú)□符合
□不符合9A.9
A.9.1
審查火災(zāi)自動(dòng)報(bào)警、交設(shè)施符合B132□有
□無(wú)□符合
□不符合B133
90s
□有
□無(wú)□符合
□不符合aB134消防設(shè)施配置等級(jí)為
B
級(jí)以上的隧道應(yīng)設(shè)置火災(zāi)自動(dòng)報(bào)警□有
□無(wú)□符合
□不符合警控元的B135□有
□無(wú)□符合
□不符合B136□有
□無(wú)□符合
□不符合B137
IP65□有
□無(wú)□符合
□不符合c元、探測(cè)電話B138□有
□無(wú)□符合
□不符合c元、探測(cè)電話B139□有
□無(wú)□符合
□不符合B140□有
□無(wú)□符合
□不符合B141
4.50m□有
□無(wú)□符合
□不符合B1421
2
3
60s□有
□無(wú)□符合
□不符合9A.9
c元、探測(cè)電話B143隧道內(nèi)手動(dòng)報(bào)警按鈕設(shè)置間距不應(yīng)大于
50m,宜與消火栓
1.30m1.50m□有
□無(wú)□符合
□不符合B144□有
□無(wú)□符合
□不符合B145
1m□有
□無(wú)□符合
□不符合
1.2mB1461.2m
1m□有
□無(wú)□符合
□不符合B147在隧災(zāi)報(bào)應(yīng)設(shè)保護(hù)□有
□無(wú)□符合
□不符合B148火災(zāi)未設(shè)播的置火□有
□無(wú)□符合
□不符合B149聲光設(shè)置央控道入100—150m
□有
□無(wú)□符合
□不符合B150數(shù)不應(yīng)超過(guò)
32
點(diǎn);總線穿越防火分區(qū)時(shí),應(yīng)在穿越處設(shè)置□有
□無(wú)□符合
□不符合B151
200m
□有
□無(wú)□符合
□不符合B1521
匯接各緊急電話分機(jī)傳輸線路,控制各緊急電話分機(jī)的2
3
允許兩處及兩處以上緊急電話分機(jī)同時(shí)排隊(duì)報(bào)警,并具4
5
6
□有
□無(wú)□符合
□不符合9A.9
c元、探測(cè)電話B153□有
□無(wú)□符合
□不符合B1541
□有
□無(wú)□符合
□不符合2
3
聲學(xué)特性指標(biāo)不應(yīng)低于會(huì)議類擴(kuò)聲系統(tǒng)二級(jí)聲學(xué)特性指)系統(tǒng)的供電與通信的設(shè)審查傳輸持續(xù)B155□有
□無(wú)□符合
□不符合B156池維持供電時(shí)間不應(yīng)小于
3h;采用集中設(shè)置的蓄電池時(shí),□有
□無(wú)□符合
□不符合e重審、隧系統(tǒng)系統(tǒng)B157探測(cè)主電置剩作?!跤?/p>
□無(wú)□符合
□不符合B158探測(cè)的隧息傳采用□有
□無(wú)□符合
□不符合B159“”□有
□無(wú)□符合
□不符合B160□有
□無(wú)□符合
□不符合A.9.2
審查應(yīng)急照明和疏志的,具a計(jì)是B161500m
30min□有
□無(wú)□符合
□不符合9A.9
散指B162應(yīng)急照明亮度不應(yīng)低于中間段設(shè)計(jì)亮度的
10%,且不應(yīng)低
0.2cd/m2;
1cd/m2□有
□無(wú)□符合
□不符合B163500m
D70/2-2014
□有
□無(wú)□符合
□不符合B164
1.3m
50m□有
□無(wú)□符合
□不符合A.9.3
審查消防電源設(shè)計(jì)規(guī)范:a應(yīng)用B165□有
□無(wú)□符合
□不符合)一級(jí)負(fù)荷中特別重要負(fù)二級(jí)發(fā)電型號(hào)料及供電B166設(shè)置不間斷電源裝置(UPS)或應(yīng)急電源裝置(EPS)作為□有
□無(wú)□符合
□不符合B167
30s□有
□無(wú)□符合
□不符合c是否間內(nèi)B168□有
□無(wú)□符合
□不符合B169的電源應(yīng)選用應(yīng)急供電裝置,照明中斷時(shí)間應(yīng)不大于
0.3s
30min□有
□無(wú)□符合
□不符合A.9.4
審查消防配電設(shè)計(jì)規(guī)范9A.9
a專用防用B170□有
□無(wú)□符合
□不符合內(nèi)的門等應(yīng)分的雙B171□有
□無(wú)□符合
□不符合c電回電所或總配電室放射式供水泵B172□有
□無(wú)□符合
□不符合導(dǎo)體布置B173□有
□無(wú)□符合
□不符合B174
IP55□有
□無(wú)□符合
□不符合B175□有
□無(wú)□符合
□不符合導(dǎo)體布置B176□有
□無(wú)□符合
□不符合A.9.5
審查電力線路及電火設(shè)aB177□有
□無(wú)□符合
□不符合9A.9
所是B178
30mm□有
□無(wú)□符合
□不符合B179線路通風(fēng)或直通風(fēng)□有
□無(wú)□符合
□不符合B180□有
□無(wú)□符合
□不符合B181□有
□無(wú)□符合
□不符合B182□有
□無(wú)□符合
□不符合B183□有
□無(wú)□符合
□不符合10A.10
A.10.1
審查交通監(jiān)控設(shè)機(jī)等B184立式探測(cè)入火制器□有
□無(wú)□符合
□不符合B185電流災(zāi)監(jiān)應(yīng)以壓配□有
□無(wú)□符合
□不符合B186發(fā)熱部件等部位;保護(hù)對(duì)象為
1000V
及以下的配電線路,□有
□無(wú)□符合
□不符合B187□有
□無(wú)□符合
□不符合B188隧道交通工程與附屬設(shè)施配置等級(jí)
B
及以上的隧道應(yīng)設(shè)□有
□無(wú)□符合
□不符合10A.10
A.10.2
審查交通控制與(交、可標(biāo)志)的B189隧道外攝像機(jī)應(yīng)設(shè)在距隧道口
100400m
□有
□無(wú)□符合
□不符合B190隧道內(nèi)攝像機(jī)直線段設(shè)置間距不應(yīng)大于
150m□有
□無(wú)□符合
□不符合B191CCTV)監(jiān)控系統(tǒng)主控設(shè)備應(yīng)設(shè)置在隧道管理站;應(yīng)能報(bào)警切換位的□
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2023-2024學(xué)年安徽省池州市貴池區(qū)高二下學(xué)期期中教學(xué)質(zhì)量檢測(cè)語(yǔ)文試題(解析版)
- 普洱哈尼族彝族自治縣2025年重點(diǎn)中學(xué)小升初數(shù)學(xué)入學(xué)考試卷含解析
- 四川省成都市彭州中學(xué)2025年高三下學(xué)期開(kāi)學(xué)收心考試物理試題含解析
- 山東省煙臺(tái)市棲霞市2024-2025學(xué)年高三沖刺模擬生物試題試卷含解析
- 南方醫(yī)科大學(xué)《馬克思主義民族理論與政策》2023-2024學(xué)年第二學(xué)期期末試卷
- 內(nèi)蒙古自治區(qū)錫林郭勒盟太仆寺旗寶昌鎮(zhèn)第一中學(xué)2025屆高三聯(lián)測(cè)促改化學(xué)試題含解析
- 山西省榆社縣第二小學(xué)度上義務(wù)教育2025屆數(shù)學(xué)四年級(jí)第二學(xué)期期末質(zhì)量跟蹤監(jiān)視模擬試題含解析
- 武漢鐵路橋梁職業(yè)學(xué)院《車橋耦合振動(dòng)》2023-2024學(xué)年第二學(xué)期期末試卷
- 江西傳媒職業(yè)學(xué)院《食品分析基礎(chǔ)實(shí)驗(yàn)》2023-2024學(xué)年第一學(xué)期期末試卷
- 民辦合肥濱湖職業(yè)技術(shù)學(xué)院《Matlab》2023-2024學(xué)年第二學(xué)期期末試卷
- (二模)2024~2025學(xué)年度蘇錫常鎮(zhèn)四市高三教學(xué)情況調(diào)研(二)物理試卷(含答案)
- GB/T 4798.1-1986電工電子產(chǎn)品應(yīng)用環(huán)境條件貯存
- GB/T 36572-2018電力監(jiān)控系統(tǒng)網(wǎng)絡(luò)安全防護(hù)導(dǎo)則
- GB/T 19066.1-2003柔性石墨金屬波齒復(fù)合墊片分類
- 2021年新高考I卷英語(yǔ)試題分析及備考展望2022課件
- 常見(jiàn)的圓柱截切體名師優(yōu)質(zhì)課賽課一等獎(jiǎng)市公開(kāi)課獲獎(jiǎng)?wù)n件
- 《蔣公的面子劇本》
- 護(hù)生臨床溝通能力測(cè)評(píng)量表
- 《工廠供電》第六版習(xí)習(xí)題解答(不全)
- 海水分析化學(xué) 考試大綱
- 國(guó)內(nèi)常見(jiàn)模具鋼牌號(hào)對(duì)照表
評(píng)論
0/150
提交評(píng)論