版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
2022
NorthAmericanChargingStandard
TS-0023666
2022
Contents
1.
Scope 3
2.
References 3
3.
Definitions 3
4.
FunctionalSpecifications 5
4.1
ComponentandReferenceDescriptions 5
4.2
ChargingProcess:DCCharging 9
4.3
ChargingProcess:ACCharging 10
4.4
SafetySystems 11
4.5
CommunicationbetweentheEVandEVSE 11
4.6
VehicletoX(V2X) 11
5.
GeneralConstruction 12
6.
Ratings 26
6.1
VoltageRating 26
6.2
CurrentRating 26
7.
DegreesofProtection(Informative) 27
7.1
Connector 27
7.2
Inlet 27
7.3
ConnectorandInletSystem 27
8.
TemperatureRise 28
9.
MechanicalRequirements 29
9.1
InsulatedEndCaps(informative) 29
9.2
ImpactTest(informative) 29
10.
RevisionHistory 30
3
1.Scope
ThescopeofthisdocumentcoversimplementationoftheNorthAmericanChargingStandard(NACS),includingElectricVehicle(EV)andElectricVehicleSupplyEquipment(EVSE)systemsforbothACandDCchargingsystems.
Allrequirementsarenormativeunlessotherwiseindicated.Informativereferencesindicatedassuch.
Explanatorynotesaredenotedinsmallsubtext.
2.References
Unlessotherwiseexplicitlystated,implementation&validationoftheNorth
AmericanChargingStandardiscompatiblewithIEC61851-1,IEC61851-23,IEC
62196-1,IEC62196-2,IEC62196-3,andIEC62196-23.Exceptionstothestandardsarenotedbelow.
3.Definitions
EVSE
EV
Connector
ElectricVehicleSupplyEquipment.Alsocalledchargepostorchargingstation.
Electricvehicle
ApparatusattachedtoEVSEcable,whichconnectstoEVtochargeit.Sometimescalledhandle.
Inlet
AreaonEVwhereconnectorispluggedin,tochargeit.AlsocalledChargeportorChargePort.
Socket
Pin
InterfaceContact
Areceptaclestyleelectricalcontact.Matestoapin.
Aplugstyleelectricalcontact.Matestoasocket.
Theelectricalcontactatthepin/socketinterface.
Cable
Aflexibleconductorusedtotransmitcurrentfromasourcetoaload.
3.Definitions,
cont.
BusbarArigidconductorusedtotransmitcurrentfromasourcetoaload.
EVSEEndTheendoftheconnectorassemblywhichconnectstotheEVSE.
DoorThevehicleclosureorcustomerfacingA-classthathidestheinlet
whennotinuse.
BIWBody-in-White,thesheetmetalportionofthevehiclebodythatthe
inletinterfaceswith.
B+/B-TheDCpinsonthecharginginterface.
2022
NorthAmericanChargingStandardTechnicalSpecification
4
5
4.FunctionalSpecifications
Thefollowingisasimplifiedschematicblockdiagramofthesystemwhilecharging.ComponentandreferencedescriptionsaregiveninSection4.1.
4.1Componentand
ReferenceDescriptions
4.1.1ChargingStation
Thechargingstationisanassemblyofcomponentsrequiredforchargingofavehiclebattery.
4.1.2PowerSource
Thepowersourceprovidesregulatedpowertochargethevehiclebattery.ForDCcharging,theDCpowersourceshallbeisolatedfromthegridfromwhichitderivespower.
4.1.3V
CHG
VCHGisthepowersourceoutputbusorvoltage.
4.1.4I
CHG
ICHGisthepowersourceoutputcurrent.Themaximumoutputcurrentshallbelimitedbythepowersourcecapabilitiesandthermallimitsofthesystem.
4.1.5K1andK2
K1andK2arecontactorsorrelaysusedtocontrolthe
connectionofthepowersourcetothevehiclethroughthevehicleconnector.
K1andK2arenotmandatoryandmaybeexcludedincertainsystems.
4.1.6V
FCLINK
VFCLINKisthevoltagebusthatlinksthechargingstationtothevehiclethroughthevehicleconnector.
6
4.1ComponentandReferenceDescriptions,cont.
4.1.7IsolationMonitor
Theisolationmonitormeasurestheisolationtoearthand
vehiclechassisofVCHG,VFCLINK,andVBATdependingonthe
stateofK1,K2,K3andK4.Theisolationmonitormaybe
placedonthevehiclesideofthechargingstationcontactorsK1andK2.IsolationmonitoringisonlyrelevantforDC
charging.
4.1.8ChargingStationController
Thechargingstationcontrollermonitorsandcontrolscriticalsafetysystemsandinteractionswiththevehiclecontrollertocontrolthechargingprocess.
4.1.9Earth
TheearthconnectionisusedasareferencebytheisolationmonitortomeasureisolationtoearthofVCHG,VFCLINK,andVBAT.
4.1.10VehicleConnector
Thevehicleconnectorisanoperatormoveablepartofthechargingsystemwhichprovidesconductiveconnectiontothevehicle.
4.1.11Positive(DC+)/L1
DC+/L1isthepositivesideofVFCLINK.DC+/L1isusedforpowertransferandmaybeimplementedasasingleor
dualconnectionpoint.DC+referstothevoltagewhileDCcharging,whileL1referstothevoltagewhileACcharging.
4.1.12Negative(DC-)/L2
DC-/L2isthenegativesideofVFCLINK.DC-/L2isusedforpowertransferandmaybeimplementedasasingleor
dualconnectionpoint.DC-referstothevoltagewhileDCcharging,whileL2referstothevoltagewhileACcharging.
4.1.13ControlPilot(CP)
CPisusedasadigitalcommunicationpathbetweenthe
chargingsystemandvehicle.Thecontrolpilotusespulse
widthmodulationtocommunicatechargingstateandcurrentinaccordancewithAnnexAofIEC61851-1.PowerLine
CommunicationissuperimposedontothecontrolpilotlinewhileDCcharging.
4.1.14ProximityPilot(PP)
PPisalowvoltagesignalgeneratedbyVPP,R1,R2,R3,R4,andS1(pilotproximitycircuit)andisusedtodeterminethestatusofthevehicleconnector.Thepilotproximitycircuitandvehicleconnectorstatusrelationshiparedescribedinsection4.1.28.
4.1.15Ground
Thegroundconductorprovidesaconnectionbetweenearthandvehiclechassis.
TheconnectionprovidesacommonreferencepointfortheisolationmonitortomeasureisolationofVCHG,VFCLINK,andVBATtoearthandvehiclechassis.
Theconnectionalsoprovidesacommonreferencepointforthechargingstationandvehicledigitalcommunicationandlowvoltagesignals.
7
4.1ComponentandReferenceDescriptions,cont.
4.1.16Lock
Thelockisusedtopreventinsertionorremovalofthevehicleconnectorfromthevehicleasrequired.
4.1.17S1
NormallyclosedswitchusedinconjunctionwithVPP,R1,R2,R3,andR4aspartoftheproximitypilotcircuittodeterminetheconnectionstatusofthevehicleconnector.S1islocatedinthevehicleconnectorandisoperatoraccessible.S1is
openedtoindicatedesiretostopthechargesessionanddisconnectthevehicleconnector.ImplementationofS1isoptional.
4.1.18R1andR2
ResistorsusedinconjunctionwithVPP,R3,R4,andS1aspartoftheproximitypilotcircuittodeterminetheconnection
statusofthevehicleconnector.R1andR2arelocatedinthevehicleconnector.
4.1.19Vehicle
Thevehicleisanassemblyofcomponentscontaininga
vehiclebatterywhichmaybechargedusingthechargingstation.
4.1.20K3andK4
K3andK4arecontactorsusedtocontroltheconnectionofthevehiclebatterytothechargingstation.K3andK4areclosedduringDCchargingandopenduringACcharging.
4.1.21V
BAT
VBATisthevehiclebatteryoutputbusorvoltage.
4.1.22VehicleBattery
Thevehiclebatteryisarechargeableenergystoragedeviceusetoprovidepowertoanelectricvehicledrivetrain.
4.1.23On-BoardCharger
Theon-boardchargerisusedtoconvertACtoDCpowertochargethevehiclebatterywithACchargesystems.Theon-boardchargerisbypassedwhenDCcharging.
4.1.24VehicleController
Thevehiclecontrollermonitorsandcontrolscriticalsafety
systemsandinteractionswiththechargingstationcontrollertocontrolthechargingprocess.
4.1.25V
PP
VoltagesourceusedinconjunctionwithR1,R2,R3,R4andS1aspartoftheproximitypilotcircuittodeterminethe
connectionstatusofvehicleconnector.
4.1.26R3andR4
ResistorsusedinconjunctionwithVPP,R1,R2,andS1aspartoftheproximitypilotcircuittodeterminetheconnection
statusofvehicleconnector.
4.1.27Chassis
ThechassisconnectionisusedasareferencebytheisolationmonitortomeasureisolationtovehiclechassisofVCHG,
VFCLINK,andVBAT.
8
4.1ComponentandReferenceDescriptions,cont.
4.1.28ProximityPilotCircuit
ThepilotproximitycircuitequivalentparametersaregiveninTable1.TheassociatedvehicleconnectorstatusisgiveninTable2.
ProximityPilot
CircuitComponent
EquivalentValue
V
PP
5V±10%
R1
150?±10%
R2
330?±10%
R3
330?±10%
R4
2.7K?±10%
Table1:PilotProximityCircuitEquivalentParameters
VehicleCouplerStatus
PPCharging
StationVoltage
(Nominal)
PPVehicle
Voltage
(Nominal)
Disconnected
0V
4.5V
Latched(S1Closed)
1.5V
1.5V
Unlatched(S1Open)
2.8V
2.8V
Table2:PPandVehicleConnectorStatus
9
4.2ChargingProcess:
DCCharging
ThesequencediagramanddescriptionofnormalchargingprocessforDCchargingareshowninthefigurebelowanddescribedin
section4.2.1.
4.2.1SequenceDescription
?t<t0:Theoperatorusesanyprovidedmethodto
indicatethedesiretobeginachargesession.Ifthevehicleispreparedtobeginachargesession,vehicleconnectorinsertionisallowed.
?t0–t1:Thevehicleconnectorisinsertedintothevehicle.Thelockisengagedtopreventvehicleconnector
removalandcontrolpilotcommunicationisusedforinitialparameterexchangeandcompatibilitycheck.Thelockremainsengagedanddigitalcommunicationremainsactivethroughoutthechargesession.
?t1–t2:Anoptionalinternalisolationtestisperformedon
V.
CHG
?t2–t3:K1andK2closeandanisolationtestisperformedonVCHGandVFCLINK.
?t3–t4:VCHGandVFCLINKareadjustedtomatchVBAT.
?t4–t5:K3andK4closeandenergytransferfromtheDCpowersourcetothevehiclebatterytakesplace.
?t5–t6:S1isopenedmomentarilyorforasustained
period,oranotherprovidedmethodisusedtoindicatethechargesessionshouldbestoppedandICHGisturnedoff.
?t6–t7:K1,K2,K3andK4openandVFCLINKisremoved.
?t>t7:Thelockisdisengagedtoallowvehicleconnectorremoval,endingthechargesession.
10
4.3ChargingProcess:
ACCharging
ThesequencediagramanddescriptionofnormalchargingprocessforACchargingareshowninthefigurebelowanddescribedin
section4.3.1.
4.3.1SequenceDescription
?t<t0:Theoperatorusesanyprovidedmethodto
indicatethedesiretobeginachargesession.Ifthevehicleispreparedtobeginachargesession,vehicleconnectorinsertionisallowed.
?t0–t1:Thevehicleconnectorisinsertedintothevehicle.Thelockisengagedtopreventvehicleconnector
removalandcontrolpilotcommunicationisusedfor
initialparameterexchangeandcompatibilitycheck.Thelockremainsengagedthroughoutthechargesession.
?t1–t2:OptionalinternalreadinesstestingisperformedontheEVSE.
?t2–t3:K1andK2closeandtheonboardchargersensesandmatchesthevoltageofVFCLINK.
?t3–t4:TheoutputvoltageoftheonboardchargermatchesthevoltageofVBAT.
?t4–t5:Theonboardchargerbeginsswitchingandenergytransfertothebatterybegins.
?t5–t6:S1isopenedmomentarilyorforasustained
period,oranotherprovidedmethodisusedtoindicatethechargesessionshouldbestoppedandICHGisturnedoff.
?t6–t7:K1andK2openandVFCLINKisremoved.
?t>t7:Thelockisdisengagedtoallowvehicleconnectorremoval,endingthechargesession.
11
4.4SafetySystemsThefollowingsafetysystemsprotectoperatorsfromhazards.
4.4.1PPMonitor
UpondetectionofanyPPstateotherthanlatchedor
unlatchedthepowersourceshallbedisabledandK1,K2,K3andK4shallbeopenedtoremoveVFCLINKvoltage.VFCLINKshallbe<60Vwithin1sofdetection.
4.4.2CPMonitor
UpondetectionoflossofdigitalcommunicationthepowersourceshallbedisabledandK1,K2,K3andK4shallbe
openedtoremoveVFCLINKvoltage.VFCLINKshallbe<60Vwithin1sofdetection.
4.4.3IsolationMonitor
WhileDCcharging,upondetectionofVCHG,VFCLINK,orVBAT
isolationtoearthorvehiclechassis<100?/VtheDCpowersourceshallbedisabledandK1,K2,K3andK4shallbe
openedtoremoveVFCLINKvoltage.VFCLINKshallbe<60Vwithin1sofdetection.
4.4.4VoltageandCurrentMonitor
UpondetectionofVCHG,VFCLINK,orVBATover-voltageorICHGover-currentthepowersourceshallbedisabledandK1,K2,K3andK4shallbeopenedtoremoveVFCLINKvoltage.VFCLINKshallbe<60Vwithin1sofdetection.
4.4.5VFCLINKMonitor
UpondetectionofVFCLINK>60Vtheinletlockshallremainengagedtopreventremovalofthevehicleconnector.
Thesesafetysystemsarenotcomprehensive,nordotheyfullyguaranteesafety.Additionalsafetysystems(e.g.temperaturemonitoring)mayberequiredforsafeoperation.
4.5CommunicationbetweentheEVandEVSE
4.5.1ForDCcharging,communicationbetweentheEVandEVSE
shallbepowerlinecommunicationoverthecontrolpilotlineasdepictedinDIN70121.
4.5.2TheNorthAmericanChargingStandardiscompatiblewith
“plugandcharge”asdefinedinISO-15118.
4.6VehicletoX(V2X)
4.6.1
TheNorthAmericanChargingStandardiscompatiblewith
VehicletoX(i.e.Vehicletoload,Vehicletohome,vehicle
togrid)powertransfer.Futureversionsofthistechnical
specificationwillspecifythefunctionalrequirementsand
specificationsrequiredtoachievevehicletoXpowertransfer.
12
5.GeneralConstruction
MechanicaldetailsoftheNorthAmericanChargingStandardaredetailedbelow.Foralldimensionsnotexplicitlyspecified,referto3Dmodel.
Twointerfacesareshownbelow,a500Vconfigurationand1,000Vconfiguration.Thetwointerfacesare
mechanicallyinteroperable(i.e.the1,000Vinletcanmechanicallyreceivethe500Vconnectorandthe500Vinletcanreceivethe1,000Vconnector).
5.1.1Interface
5.1.1.1
Connector
5.1.1.2
Inlet
Connector-1,000Vand500VConfiguration
Inlet-1,000Vand500VConfiguration
13
5.1.2ConnectorDimensions
500VConfiguration
1,000VConfiguration
14
5.1.2ConnectorDimensions,cont.
500VConfiguration
1,000VConfiguration
15
5.1.2ConnectorDimensions,cont.
500VConfiguration
1,000VConfiguration
16
5.1.2ConnectorDimensions,cont.
500VConfiguration
1,000VConfiguration
17
5.1.2ConnectorDimensions,cont.
500Vand1,000VConfiguration
18
5.1.3Inlet
500VConfiguration
1,000VConfiguration
19
5.1.3Inlet,cont.
500VConfiguration
1,000VConfiguration
20
5.1.3Inlet,cont.
500VConfiguration
1,000VConfiguration
21
5.1.3Inlet,cont.
500VConfiguration
1,000VConfiguration
22
5.1.3Inlet,cont.
500VConfiguration
1,000VConfiguration
23
5.1.4KeepOutZone
Thedesignoftheconnectormustremainwithinthe
keepoutzonedimensionedbelowinordertoprevent
clashesorcontactwiththevehiclebody.KeepOut
Zonegeometryisidenticalbetweenthe500Vand
1,000Vconfigurations.
24
5.1.5Latching
Latchinggeometryisidentical
betweenthe500Vand1,000V
configurations.
25
5.1.5Latching,cont.
26
6.Ratings
6.1VoltageRating
TheNorthAmericanChargingStandardexistsinbotha500Vratedconfigurationanda1,000Vratedconfiguration.The1,000Vversionismechanicallybackwardscompatible(i.e.500Vinletscanmate
with1,000Vconnectorsand500Vconnectorscanmatewith1,000Vinlets).
6.2CurrentRating
TheNorthAmericanChargingStandardshallspecifynomaximum
currentrating.Themaximumcurrentratingoftheinletorconnector
shallbedeterminedbythemanufacturer,providedthatthetemperaturelimitsdefinedinsection8aremaintained.
TeslahassuccessfullyoperatedtheNorthAmericanChargingStandardabove900Acontinuouslywithanon-liquidcooledvehicleinlet.
27
7.DegreesofProtection(Informative)
InadditiontotheconnectorandinletingressprotectionrequirementsoutlinedIEC61851-1,thefollowingadditionalvalidationisrecommendedtomaximizeproductreliability.
7.1Connector
7.1.1Whenunmatedtotheinlet,theconnectorshallwithstandanIP67wateranddusttestasdescribedinIEC60529.
7.1.2Uponcompletionofthetest,nowaterordebrisshall
bepresentonlivepartsinsidetheconnectorenclosure.
ComplianceischeckedviaahighpotentialtestbetweenHV+andHV-,andHVandground/lowvoltageattheratedtest
voltage.
7.2Inlet
7.2.1Whenmountedtoarepresentativevehiclebodypaneland
unmatedtotheconnector,theinletshallwithstandanIP67wateranddusttestasdescribedinIEC60529.
7.2.2Uponcompletionofthetest,nowaterordebrisshallbe
presentonhazardouslivepartsoftheinlet,excluding
theexteriorfacingpins.Complianceischeckedviaahigh
potentialtestbetweenHV+andHV-,andHVandground/lowvoltageattheratedtestvoltage.
7.2.3Whenmountedtoarepresentativevehiclebodypanel
andunmatedtotheconnector,theinletshallwithstandanIP6K9KwatertestasdescribedinIEC60529.
7.2.4Uponcompletionofthetest,nowaterordebrisshallbe
presentonhazardouslivepartsoftheinlet,excluding
theexteriorfacingpins.Complianceischeckedviaahigh
potentialtestbetweenHV+andHV-,andHVandground/lowvoltageattheratedtestvoltage.
7.3ConnectorandInlet
System
7.3.1Withtheinletmountedtoarepresentativebodypaneland
theconnectormatedtotheinlet,thesystemshallwithstandanIP44testasdescribedinIEC60529.
7.3.2Uponcompletionofthetest,thesystemisolationshallbe
maintained.ComplianceischeckedviaahighpotentialtestbetweenHV+andHV-,andHVandground/lowvoltageattheratedtestvoltage.
InformativeRequirementstronglyrecommendedbasedonfieldexperience.
28
8.TemperatureRise
8.1.1WhensubjecttothetemperaturerisetestofIEC62196-1
section24,themaximuminterfacecontacttemperatureshallbe105?C.
Modernthermoplasticsarecommonlyratedto120°Candhigher.TheIEC62196limitof90°Cartificiallylimitsperformancecap
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 成品油公路運(yùn)輸合同
- 通信線路工程合同
- 2025三年級(jí)冀教版語(yǔ)文下學(xué)期期中綜合復(fù)習(xí)考點(diǎn)知識(shí)練習(xí)
- 感恩老師國(guó)旗下講話(30篇)
- 領(lǐng)導(dǎo)小組工作會(huì)議講話材料(3篇)
- 提升教育教學(xué)質(zhì)量方案
- 高校教學(xué)管理工作總結(jié)
- 2025年酒店財(cái)務(wù)部工作計(jì)劃
- 學(xué)校建筑安全生產(chǎn)培訓(xùn)
- 2024年初中教學(xué)個(gè)人工作總結(jié)
- 生物醫(yī)藥行業(yè)市場(chǎng)前景及投資研究報(bào)告:代謝相關(guān)脂肪肝炎(MASHNASH)無(wú)藥可治巨大市場(chǎng)需求
- 2024年醫(yī)藥衛(wèi)生考試-靜脈治療知識(shí)筆試參考題庫(kù)含答案
- 《輸變電工程三維協(xié)同設(shè)計(jì)規(guī)范》
- 保潔員崗位安全知識(shí)培訓(xùn)
- 第二單元大單元教學(xué)設(shè)計(jì) 2023-2024學(xué)年統(tǒng)編版高中語(yǔ)文必修上冊(cè)
- JTT513-2004 公路工程土工合成材料 土工網(wǎng)
- 2024年高考語(yǔ)文復(fù)習(xí):文言文斷句專項(xiàng)練習(xí)題匯編(含答案解析)
- 中醫(yī)科醫(yī)院感染管理制度(全新版)
- 2023廣東省廣州市一模英語(yǔ)真題及答案
- 屈原【六幕話劇】郭沫若
- 茶葉抖音方案
評(píng)論
0/150
提交評(píng)論