版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
目錄
重要信息___________________________________________________________________________________________________________________4
開(kāi)始之前___________________________________________________________________________________________________________________5
文檔結(jié)構(gòu)____________________________________________________________________________________________________________________7
軟件改進(jìn)方面_______________________________________________________________________________________________________________8
設(shè)置步驟(參考快速起動(dòng))____________________________________________________________________________________________________9
設(shè)置-初步建議_____________________________________________________________________________________________________________10
變頻器型號(hào)_________________________________________________________________________________________________________________11
尺寸與重量_________________________________________________________________________________________________________________12
安裝________________________________________________________________________________________________________________________13
接線________________________________________________________________________________________________________________________16
電源端子__________________________________________________________________________________________________________________20
控制端子__________________________________________________________________________________________________________________23
檢查清單__________________________________________________________________________________________________________________29
出廠設(shè)置__________________________________________________________________________________________________________________30
基本功能___________________________________________________________________________________________________________________31
編程_______________________________________________________________________________________________________________________32
參數(shù)表結(jié)構(gòu)________________________________________________________________________________________________________________33
功能兼容性表______________________________________________________________________________________________________________36
給定模式rEF_______________________________________________________________________________________________________________37
監(jiān)視模式MOn______________________________________________________________________________________________________________38
配置模式ConF_____________________________________________________________________________________________________________44
配置模式-MyMenu_________________________________________________________________________________________________________45
配置模式-完整菜單(FULL)__________________________________________________________________________________________________47
維護(hù)_______________________________________________________________________________________________________________________99
替換ATV11-ATV12________________________________________________________________________________________________________100
診斷和故障檢修___________________________________________________________________________________________________________107
應(yīng)用說(shuō)明__________________________________________________________________________________________________________________113
短路等級(jí)和支路保護(hù)________________________________________________________________________________________________________119
Wiring____________________________________________________________________________________________________________________120
組織樹(shù)____________________________________________________________________________________________________________________121
參數(shù)索引__________________________________________________________________________________________________________________122
3
重要信息
注意
在安裝、操作或維護(hù)本設(shè)備之前,請(qǐng)仔細(xì)閱讀這些說(shuō)明,并熟悉本設(shè)備。在本手冊(cè)中或設(shè)備上可能會(huì)出現(xiàn)下列特殊信息,以告誡潛在的危險(xiǎn)
或提醒您注意那些闡明或簡(jiǎn)化某過(guò)程的信息。
“危險(xiǎn)”或“警告”標(biāo)簽上附加的本符號(hào)表示存在電擊危險(xiǎn),如果使用者不遵照使用說(shuō)明進(jìn)行操作,會(huì)造成人身傷害。
這是提醒注意安全的符號(hào)。用于提醒您此處存在可能會(huì)造成人身傷害的安全隱患。請(qǐng)務(wù)必遵循此標(biāo)志附注的所有安全須知進(jìn)行操
作,以免造成人員傷亡。
危險(xiǎn)
“危險(xiǎn)”表示極可能存在危險(xiǎn),如果不遵守說(shuō)明,可能將導(dǎo)致嚴(yán)重的人身傷害甚至死亡。
警告
警告表示可能存在危險(xiǎn),如果不遵守說(shuō)明,可導(dǎo)致嚴(yán)重的人身傷害、死亡或設(shè)備損壞。
小心
“小心”表示可能存在危險(xiǎn),如果不遵守說(shuō)明,可導(dǎo)致人身傷害或設(shè)備損壞。
小心
不帶有安全警示符號(hào)的“小心”標(biāo)識(shí),表示可能存在危險(xiǎn),如果不遵守說(shuō)明,可導(dǎo)致設(shè)備損壞。
請(qǐng)注意
本手冊(cè)中使用的“變頻器”一詞指的是可調(diào)速變頻器的控制器部分,如NEC的定義所述。
電氣設(shè)備只能由專業(yè)人員進(jìn)行安裝、操作、維修和維護(hù)。SchneiderElectric對(duì)于不遵循本說(shuō)明而引發(fā)的任何后果概不負(fù)責(zé)。
4
開(kāi)始之前
在對(duì)本變頻器進(jìn)行任何操作之前,請(qǐng)閱讀并理解下列說(shuō)明。
危險(xiǎn)
電擊、爆炸或電弧危險(xiǎn)
?在安裝或操作ATV12變頻器之前,請(qǐng)先閱讀并理解本手冊(cè)。只有專業(yè)人員才能對(duì)此變頻器進(jìn)行安裝、調(diào)節(jié)、修理與維護(hù)。
?用戶有責(zé)任遵守國(guó)際和國(guó)內(nèi)有關(guān)所有設(shè)備接地事項(xiàng)的電氣規(guī)范要求。
?本變頻器的許多部件(包括印刷電路板)在線電壓下工作。切勿觸碰。只能使用絕緣工具。
?切勿在通電情況下觸碰未屏蔽的組件或端子排螺釘。
?切勿在端子PA/+和PC/-或直流母線電容器之間進(jìn)行短路連接。
?在對(duì)變頻器進(jìn)行維修之前:
-斷開(kāi)所有電源,包括可能會(huì)帶電的外部控制電源。
-在所有電源斷路器上放置“禁止合閘”標(biāo)簽。
-將所有電源斷路器鎖定在打開(kāi)位置。
-等待15分鐘,使直流母線放電。
-測(cè)量PA/+和PC/-端子之間的直流母線電壓,確保電壓低于直流42V。
-如果直流母線電容器放電不完全,請(qǐng)聯(lián)系您當(dāng)?shù)氐氖┠偷码姎夤镜拇怼U?qǐng)勿自行修理或操作變頻器。
?在通電或起動(dòng)和停止變頻器前,請(qǐng)安裝和合上所有機(jī)蓋。
不按照說(shuō)明操作可能會(huì)導(dǎo)致嚴(yán)重的人身傷亡。
危險(xiǎn)
異常設(shè)備操作
?在安裝或操作ATV12變頻器之前,請(qǐng)先閱讀并理解本手冊(cè)。
?任何參數(shù)設(shè)置的更改,都必須由專業(yè)人員來(lái)進(jìn)行。
不按照說(shuō)明操作可能會(huì)導(dǎo)致嚴(yán)重的人身傷亡。
警告
已損壞的變頻器設(shè)備
請(qǐng)勿操作或安裝任何看起來(lái)已損壞的變頻器或變頻器配件。
不按照說(shuō)明操作可能導(dǎo)致人身傷亡或設(shè)備損壞。
5
開(kāi)始之前
警告
失控
?任何控制方案的設(shè)計(jì)者都必須
-考慮到控制路徑可能失敗的情況,并為某些關(guān)鍵功能提供一種方法,
-使其在出現(xiàn)路徑故障時(shí),以及出現(xiàn)故障后恢復(fù)至安全狀態(tài)。
關(guān)鍵控制功能的示例包括緊急制動(dòng)和越程制動(dòng)。
?必須為關(guān)鍵控制功能提供單獨(dú)或冗余控制路徑。
?系統(tǒng)控制路徑可能包括通訊鏈接。必須考慮到異常傳輸延遲或鏈接故障的可能性。a
不按照說(shuō)明操作可能導(dǎo)致人身傷亡或設(shè)備損壞。
a.有關(guān)更多信息,請(qǐng)參閱NEMAICS1.1(最新版本)中“固體電路控制系統(tǒng)的應(yīng)用、安裝及維護(hù)安全守則”以及NEMAICS7.1(最新版本)中
“結(jié)構(gòu)安全標(biāo)準(zhǔn)及可調(diào)速驅(qū)動(dòng)系統(tǒng)的選擇、安裝與操作指南”中的說(shuō)明。
小心
線電壓不一致
起動(dòng)和配置變頻器之前,應(yīng)確保線電壓符合變頻器銘牌標(biāo)注的電源電壓范圍。如果線電壓不在此范圍內(nèi),可能導(dǎo)致變頻器損壞。
不按照說(shuō)明操作可能導(dǎo)致設(shè)備損壞。
并聯(lián)使用電機(jī)
小心
電機(jī)損壞風(fēng)險(xiǎn)
此時(shí)變頻器不再提供電機(jī)熱保護(hù)。請(qǐng)為每臺(tái)電機(jī)提供其他熱保護(hù)方法。
不按照說(shuō)明操作可能導(dǎo)致設(shè)備損壞。
6
文檔結(jié)構(gòu)
下列ATV12技術(shù)文件可在施耐德電氣網(wǎng)站以及隨變頻器一起提供的DVD-ROM(參考編號(hào)VW3A8200)上
獲得。
安裝及編程手冊(cè)
此手冊(cè)介紹變頻器的安裝、調(diào)試、操作和編程方法。
簡(jiǎn)明手冊(cè)
此手冊(cè)是本手冊(cè)的簡(jiǎn)明版本,隨變頻器一起提供。
快速起動(dòng)
“快速起動(dòng)”介紹對(duì)于簡(jiǎn)單應(yīng)用如何連接和配置變頻器以簡(jiǎn)單快速地起動(dòng)電機(jī)。此文檔隨變頻器一起提供。
Modbus通訊手冊(cè)
這些手冊(cè)介紹裝配、與總線或網(wǎng)絡(luò)的連接、信號(hào)發(fā)送、診斷以及通過(guò)7段LED顯示終端的通訊特定參數(shù)的配置。
此手冊(cè)還介紹了Modbus協(xié)議的通訊服務(wù)。
此手冊(cè)還列述了所有的Modbus地址,并闡述了具體的通訊模式(狀態(tài)圖)。
ATV12P手冊(cè)
此手冊(cè)介紹ATV12P變頻器的具體性能參數(shù)。
7
設(shè)置步驟(參考快速起動(dòng))
1.接收和檢查變頻器
v檢查印刷在標(biāo)簽上的變頻器型號(hào)是否與訂貨單相符
v從包裝箱中取出ATV12,檢查變頻器是否在運(yùn)輸過(guò)程中發(fā)生損壞。
2.檢查線電壓
v檢查變頻器的電源電壓范圍(第11頁(yè))是否與線電壓兼容。
3.安裝變頻器
v按照本文檔中的說(shuō)明安裝變頻器。(第13頁(yè))
步驟2至4必須在斷v安裝所有必需的選件。
電情況下執(zhí)行。
4.連接變頻器線路(第20頁(yè))
v連接電機(jī),確保與進(jìn)線電壓匹配。
v確保電源斷開(kāi)后連接電源。
v連接控制部件。
5.配置變頻器參數(shù)(第32頁(yè))
v給變頻器通電,但不給出運(yùn)行
命令。
v僅當(dāng)變頻器的出廠設(shè)置不適用時(shí)才
需設(shè)置電機(jī)參數(shù)(在配置Conf模
式下)。
v執(zhí)行自整定操作。
6.起動(dòng)
9
設(shè)置-初步建議
在變頻器通電之前
危險(xiǎn)
異常設(shè)備操作
確保所有邏輯輸入均為無(wú)效,以防止意外起動(dòng)。
不按照說(shuō)明操作可能會(huì)導(dǎo)致嚴(yán)重的人身傷亡。
在配置變頻器參數(shù)之前
危險(xiǎn)
異常設(shè)備操作
?在安裝或操作ATV12變頻器之前,請(qǐng)先閱讀并理解本手冊(cè)。
?任何參數(shù)設(shè)置的更改,都必須由專業(yè)人員來(lái)進(jìn)行。
?確保所有邏輯輸入均為無(wú)效,以防止修改參數(shù)時(shí)發(fā)生意外起動(dòng)。
不按照說(shuō)明操作可能會(huì)導(dǎo)致嚴(yán)重的人身傷亡。
變頻器配合不同規(guī)格的電機(jī)使用
電機(jī)的額定值可能不同于變頻器。對(duì)于功率較小的電機(jī),不需要特別進(jìn)行計(jì)算。必須將電機(jī)熱電流ItH參數(shù)(第94頁(yè))設(shè)置為電機(jī)電流。
對(duì)于大功率(可能達(dá)到變頻器的2倍)電機(jī),例如,使用2.2KW(3HP)變頻器驅(qū)動(dòng)4KW(5.5HP)電機(jī),必須確保電機(jī)電流和電機(jī)實(shí)際功率不
超過(guò)變頻器額定功率。
線路接觸器
小心
變頻器損壞風(fēng)險(xiǎn)
?避免頻繁操作接觸器,以防止濾波電容器過(guò)早老化。
?功率循環(huán)周期必須大于60秒。
不按照說(shuō)明操作可能會(huì)導(dǎo)致設(shè)備損壞。
使用額定值較小的電機(jī)或不使用電機(jī)
?在出廠設(shè)置模式下,輸出缺相OPL(第94頁(yè))激活(OPL=YES)。要在測(cè)試或維護(hù)環(huán)境下檢測(cè)修變頻器而不切換到與變頻器額定
值相同的電機(jī)(對(duì)于大功率變頻器尤其有用),應(yīng)該禁用輸出缺相OPL(OPL=nO)。
?在電機(jī)控制菜單drC-中,將電機(jī)控制類(lèi)型Ctt(第57頁(yè))設(shè)置為Std。
小心
電機(jī)損壞風(fēng)險(xiǎn)
如果電機(jī)額定電流低于變頻器額定電流的20%,將不能提供電機(jī)熱保護(hù)。請(qǐng)?zhí)峁┢渌麩岜Wo(hù)方法。
不按照說(shuō)明操作可能會(huì)導(dǎo)致設(shè)備損壞。
10
變頻器額定值
單相電源電壓:100...120V50/60Hz
針對(duì)三相輸出200/240V電機(jī)
電機(jī)供電線路(輸入)變頻器(輸出)尺寸
銘牌標(biāo)注功率(1)最大線路電流視在功率額定電流下額定電流最大瞬時(shí)電流(3)
100V120V耗散功率(1)In60s2s
kWHPAAkVAWAAA
0.180.25651181.42.12.3ATV12H018F11C1
0.370.511.49.31.9292.43.64ATV12H037F11C1
0.75118.915.73.3484.26.36.9ATV12H075F12C1
單相電源電壓:200...240V50/60Hz
針對(duì)三相輸出200/240V電機(jī)
電機(jī)供電線路(輸入)變頻器(輸出)尺寸
銘牌標(biāo)注功率(1)最大線路電流視在功率額定電流下額定電流最大瞬時(shí)電流(3)
200V240V耗散功率(1)In60s2s
kWHPAAkVAWAAA
0.180.253.42.81.2181.42.12.3ATV12H018M21C2
0.370.55.94.92272.43.64ATV12H037M21C2
0.550.7586.72.8343.55.35.8ATV12H055M21C2
0.75110.28.53.5444.26.36.9ATV12H075M21C2
1.5217.814.96.2727.511.212.4ATV12HU15M22C2
2.232420.28.493101516.5ATV12HU22M22C2
三相電源電壓:200...240V50/60Hz
針對(duì)三相輸出200/240V電機(jī)
電機(jī)供電線路(輸入)變頻器(輸出)尺寸
銘牌標(biāo)注功率(1)最大線路電流視在功率額定電流下額定電流最大瞬時(shí)電流(3)
200V240V耗散功率(1)In60s2s
kWHPAAkVAWAAA
0.180.2521.70.7161.42.12.3ATV12H018M31C3
0.370.53.631.2242.43.64ATV12H037M31C3
0.7516.35.32.2414.26.36.9ATV12H075M31C3
1.5211.19.33.9737.511.212.4ATV12HU15M32F3
2.2314.912.55.285101516.5ATV12HU22M32F3
341915.96.69412.218.320.1ATV12HU30M33F3
45.523.819.98.312816.72527.6ATV12HU40M33F3
(1)這些功率額定值適用于開(kāi)關(guān)頻率為4kHz,連續(xù)運(yùn)行場(chǎng)合。開(kāi)關(guān)頻率可調(diào)整范圍為2-16
kHz。
在4kHz以上,如果溫升過(guò)高,變頻器就會(huì)減小開(kāi)關(guān)頻率。功率模塊內(nèi)的探針可檢測(cè)到溫
度升高。如果需要在4kHz以上連續(xù)運(yùn)行,變頻器的額定電流就會(huì)降低:
?對(duì)于8kHz的開(kāi)關(guān)頻率,額定電流降低10%
?對(duì)于12kHz的開(kāi)關(guān)頻率,額定電流降低20%
?對(duì)于16kHz的開(kāi)關(guān)頻率,額定電流降低30%
(3)尺寸說(shuō)明
2F3
可能值1物理尺寸1可能值F普通型可能值1100V單相
2物理尺寸2C精巧型2200V單相
3物理尺寸33200V三相
11
尺寸與重量
ATV12H018F1,018M2,037F1,037M2,037M3,018M2,018M3,055M2,075M2
abcGHH1?重量
ATV12Hmmmmmmmmmmmmmmkg
(in.)(in.)(in.)(in.)(in.)(in.)(in.)(lb)
018F1
72142102.2601311432x50.7
018M2M4
(2.83)(5.59)(4.02)(2.36)(5.16)(5.63)(2x0.20)(1.5)
018M3
037F1
72130121.2601201432x50.8
037M2M4
(2.83)(5.12)(4.77)(2.36)(4.72)(5.63)(2x0.20)(1.8)
037M3
055M2
72130131.2601201432x50.8
075M2M4
(2.83)(5.12)(5.17)(2.36)(4.72)(5.63)(2x0.20)(1.8)
075M3
ATV12H075F1,U15M2,U22M2,U15M3,U22M3
abcGHH1?重量
ATV12Hmmmmmmmmmmmmmmkg
(in.)(in.)(in.)(in.)(in.)(in.)(in.)(lb)
105130156.2931201422x51.3
075F1M4
(4.13)(5.12)(6.15)(3.66)(4.72)(5.59)(2x0.20)(2.9)
U15M2105130156.2931201422x51.4
M4
U22M2(4.13)(5.12)(6.15)(3.66)(4.72)(5.59)(2x0.20)(3.1)
U15M3105130131.2931201432x51.2
M4
U22M3(4.13)(5.12)(5.17)(3.66)(4.72)(5.63)(2x0.20)(2.6)
ATV12HU30M3,U40M3
abcGHH1?重量
ATV12Hmmmmmmmmmmmmmmkg
(in.)(in.)(in.)(in.)(in.)(in.)(in.)(lb)
U30M3140170141.21261591844x52.0
M4
U40M3(5.51)(6.69)(5.56)(4.96)(6.26)(7.24)(2x0.20)(4.4)
12
安裝
安裝和溫度條件
垂直安裝此設(shè)備,誤差在±10°之間。
請(qǐng)勿將其靠近發(fā)熱元件安裝。
50mm
≥
(2in)留出足夠的自由空間,確??諝饪梢詮牡撞客〞车匮h(huán)到變頻器頂部以進(jìn)行冷卻。
變頻器前方的自由空間:最少10毫米(0.4英寸)。
≥d≥d
當(dāng)IP20保護(hù)足夠時(shí),我們建議您拆除變頻器頂部的通風(fēng)孔蓋板,如下圖所示。
我們建議您將變頻器安裝到散熱性能良好的平面上。
50mm
≥
(2in)
取下通風(fēng)孔蓋板
安裝類(lèi)型
安裝類(lèi)型A
≥50mm≥50mm
(2in.)(2in.)帶有通風(fēng)孔蓋板,兩側(cè)留有自由空間≥50毫米
(≥2英寸)。安裝類(lèi)型A適合溫度小于或等于50°C(122°F)的變頻器運(yùn)行環(huán)境。
安裝類(lèi)型B
并排安裝變頻器,不帶通風(fēng)孔蓋板(保護(hù)級(jí)別變?yōu)镮P20)。
安裝類(lèi)型C
≥50mm≥50mm
不帶通風(fēng)孔蓋板,兩側(cè)留有自由空間≥50毫米
(2in.)(2in.)
(≥2英寸),適合溫度高于50°C(122°F)的運(yùn)行環(huán)境。保護(hù)等級(jí)變?yōu)镮P20。
使用這些安裝類(lèi)型,開(kāi)關(guān)頻率為4kHz的變頻器可在溫度最高為50°C(122°F)的環(huán)境中使用。無(wú)風(fēng)扇的變頻器需要降容。
13
安裝
降容曲線
變頻器額定電流(In)下的降容曲線,與溫度、開(kāi)關(guān)頻率和安裝類(lèi)型等因素相關(guān)。
ATV12H0ppM2,ATV12H0ppM3,ATV12H018F1至ATV12H037F1
40°C(104°F),安裝類(lèi)型A和C
50°C(122°F),安裝類(lèi)型C,帶金屬板
40°C(104°F),安裝類(lèi)型B
60°C(140°F),安裝類(lèi)型A、B和C
開(kāi)關(guān)頻率(kHz)
ATV12HUppM2,ATV12H075F1,ATV12HU15M3toATV12HU40M3
50°C(122°F),安裝類(lèi)型A、B和C
60°C(140°F),安裝類(lèi)型C,帶金屬板
開(kāi)關(guān)頻率(kHz)
中間溫度(例如,55°C(131°F))的曲線介于兩條曲線之間。
直流母線電壓測(cè)量步驟
危險(xiǎn)
電擊、爆炸或電弧危險(xiǎn)
執(zhí)行此步驟之前,請(qǐng)閱讀并理解“開(kāi)始之前”(第5頁(yè))介紹的注意事項(xiàng)
不按照說(shuō)明操作可能導(dǎo)致人身傷亡
直流母線電壓可以超過(guò)400Vdc。執(zhí)行此操作時(shí),請(qǐng)使用適當(dāng)?shù)念~定電壓感應(yīng)設(shè)備。直流母線電壓測(cè)量步驟:
1斷開(kāi)所有電源
2等待15分鐘,使直流母線放電
3測(cè)量PA/+和PC/-端子之間的直流母線電壓,確保電壓低于42Vdc
4如果直流母線電容器放電不完全,請(qǐng)聯(lián)系您當(dāng)?shù)氐氖┠偷码姎獯?。?qǐng)勿自行修理或操作變頻器
14
安裝
安裝EMC板
EMC安裝板:尺寸1VW3A9523,尺寸2VW3A9524或尺寸3VW3A9525,需單獨(dú)訂購(gòu)
使用隨送的2顆螺釘,將EMC安裝板固定到ATV12的孔眼上,如下圖所示。
尺寸1,EMC板型號(hào)VW3A9523:適用于
ATV12H018F1,ATV12H037F1,ATV12P037F1,
ATV12H018M2,ATV12p0ppM2,ATV12p0ppM3
1.2個(gè)安裝螺釘
2.4顆M4螺釘,用于固定EMC夾具
11
2尺寸3,EMC板型號(hào)VW3A9525:適用于
2ATV12pU30M3和ATV12pU40M3
22
尺寸2,EMC板型號(hào)VW3A9524:適用于
ATV12H075F1,ATV12HUppM2,ATV12pU15M3,
ATV12pU22M3
1111
22
2
2
2
222
15
接線
建議
請(qǐng)保持電源線與設(shè)備中弱電信號(hào)電路(檢測(cè)器、PLC、測(cè)量?jī)x器、視頻、電話)之間的隔離。如果可能,控制電纜和電源線交叉時(shí)始終保持
90度。
電源和電路保護(hù)
請(qǐng)遵照當(dāng)?shù)匾?guī)范和標(biāo)準(zhǔn)所建議的線纜尺寸。
在連接電源端子前,請(qǐng)先將接地端子連接到位于輸出端子下方的接地螺釘上(請(qǐng)參閱“使用環(huán)形端子連接電機(jī)端子”(第21頁(yè)))。
必須按照相應(yīng)的安全標(biāo)準(zhǔn)將變頻器接地。ATV12ppppM2變頻器帶有內(nèi)置EMC濾波器,故漏電電流會(huì)超過(guò)3.5mA。
安裝標(biāo)準(zhǔn)要求使用剩余電流保護(hù)器來(lái)提供上游保護(hù)時(shí),請(qǐng)對(duì)單相變頻器使用A類(lèi)斷路器,對(duì)三相變頻器使用B類(lèi)斷路器。請(qǐng)選擇集成有下列
功能的合適型號(hào):
?高頻電流濾波
?延時(shí)裝置,用以防止在通電起動(dòng)時(shí)由于寄生電容產(chǎn)生的負(fù)載造成跳閘。此延時(shí)裝置不適用于30mA以下的設(shè)備。
在此情況下,應(yīng)選擇具有高抗干擾性能的設(shè)備,例如,帶有SI類(lèi)漏電保護(hù)的RCD。
如果安裝多個(gè)變頻器,應(yīng)該為每個(gè)變頻器提供一個(gè)“剩余電流保護(hù)器”。
控制
對(duì)于控制和速度給定電路,我們建議使用尺寸為25到50毫米之間(1到2英寸)的屏蔽雙絞線,請(qǐng)按照第26頁(yè)所述將屏蔽層接地。
電機(jī)電纜的長(zhǎng)度
對(duì)于長(zhǎng)度超過(guò)50米(164英尺)的電機(jī)屏蔽電纜和超過(guò)100米(328英尺)的非屏蔽電纜,請(qǐng)加裝輸出濾波器。
對(duì)于選件訂貨號(hào),請(qǐng)參見(jiàn)產(chǎn)品目錄。
設(shè)備接地
請(qǐng)按照當(dāng)?shù)睾蛧?guó)家的規(guī)范要求將變頻器接地。電纜尺寸可能至少需要達(dá)到10平方毫米(6AWG)才能符合限制泄漏電流的標(biāo)準(zhǔn)。
危險(xiǎn)
電擊、爆炸或電弧危險(xiǎn)
?變頻器必須先正確接地,才能接通電源。
?請(qǐng)使用下圖所示的接地方式。
不按照說(shuō)明操作可能導(dǎo)致人身傷亡。
危險(xiǎn)
ATV12H075F1,ATV12H075M2和ATV12H075M3-接地連續(xù)性危險(xiǎn)
經(jīng)過(guò)陽(yáng)極鈍化處理的散熱器可能形成安裝表面的絕緣障壁。請(qǐng)務(wù)必遵守接地建議。
不按照說(shuō)明操作可能導(dǎo)致人身傷亡。
?確保接地電阻小于或等于一歐姆。
?將多個(gè)變頻器接地時(shí),您必須將每個(gè)變頻器直接接地。
如左圖所示。
?請(qǐng)勿將接地線形成回路或?qū)⑺鼈兇?lián)在一起。
16
接線
警告
損壞變頻器的風(fēng)險(xiǎn)
?如果將電源電壓連接至輸出端子(U/T1,V/T2,W/T3),將會(huì)損壞變頻器。
?在對(duì)變頻器通電前,請(qǐng)先檢查電源連接。
?如果更換其他變頻器,請(qǐng)驗(yàn)證變頻器的所有接線都符合本手冊(cè)中的接線說(shuō)明。
不按照說(shuō)明操作可能導(dǎo)致人身傷亡或設(shè)備損壞。
警告
過(guò)流保護(hù)不足
?過(guò)流保護(hù)設(shè)備必須經(jīng)過(guò)適當(dāng)調(diào)整。
?加拿大電氣規(guī)范和美國(guó)國(guó)家電氣規(guī)范要求提供支路保護(hù)。請(qǐng)選用本手冊(cè)(第121頁(yè))中推薦的保險(xiǎn)絲。
?請(qǐng)勿將變頻器連接到短路容量超過(guò)本手冊(cè)(第121頁(yè))列出的變頻器短路電流額定值的電源上。
不按照說(shuō)明操作可能導(dǎo)致人身傷亡或設(shè)備損壞。
17
接線
常規(guī)接線圖
ATV12ppppF1單相電源100...120V
ATV12ppppM2單相電源200...240V
ATV12ppppM3三相電源200...240V
(4)
電源
(5)三相
電機(jī)
(1)R1繼電器觸點(diǎn),用于遠(yuǎn)程指示變頻器狀態(tài)。
(2)內(nèi)部+24Vc。如果使用外部電源(最高+30Vc),請(qǐng)將該電源的0V連接到COM端子,不要使用變頻器上的+24Vc端子。
(3)給定電位計(jì)SZ1RV1202(2.2kΩ)或類(lèi)似設(shè)備(最大10kΩ)。
(4)可選制動(dòng)模塊VW3A7005。
(5)可選制動(dòng)電阻器VW3A7ppp或其他可接受的電阻器。請(qǐng)參考產(chǎn)品目錄中的可用電阻器參數(shù)值。
注意:
?對(duì)于靠近變頻器或耦合于同一回路的所有感性電路(繼電器、接觸器、電磁閥等)均應(yīng)安裝干擾抑制器。
?接地端子(綠色螺釘)的位置與ATV11上的接地端子的位置相反(請(qǐng)參見(jiàn)接線座標(biāo)簽)。
18
接線
接線標(biāo)簽
ATV12HpppF1
輸入120V
輸出240V
漏型
源型
ATV12HpppM2
輸入240V
輸出240V
漏型
源型
ATV12HpppM3
輸入240V
輸出240V
漏型
源型
19
電源端子
線電源端子位于變頻器頂部,到電機(jī)的輸出端子位于變頻器底部。如果使用屏蔽層已撥開(kāi)的電纜,則無(wú)需打開(kāi)接線蓋即可連接到電源端子。
操作電源端子
使用屏蔽層撥開(kāi)的電纜連接電源端子
危險(xiǎn)
電擊、爆炸或電弧危險(xiǎn)
在通電前請(qǐng)先裝上接線蓋。
不按照說(shuō)明操作可能導(dǎo)致人身傷亡。
小心
人身傷害的風(fēng)險(xiǎn)
請(qǐng)使用鑷子清除接線蓋上的殘留的電纜碎片。
不按照說(shuō)明操作可能導(dǎo)致人身傷害或設(shè)備損壞。
使用環(huán)形端子連接電源端子
接線蓋
A)ATV12ppppM2上的IT跳線
B)接地螺釘位于輸出端子下方。
20
電源端子
使用環(huán)形端子連接電機(jī)端子
電源端子的特征和功能
端子功能ATV12
t
R/L1-S/L2/N
R/L1-S/L2/N
R/L1-S/L2-T/L3
PA/++極性直流母線輸出至制動(dòng)單元(接線蓋上可見(jiàn)部分)
PC/--極性直流母線輸出至制動(dòng)單元(接線蓋上可見(jiàn)部分)
PO未使用
U/T1-V/T2-W/T3
21
電源端子
電源端子的排列
ATV12H018F1,037F1,0ppM2,0ppM3
可
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 二零二五版國(guó)際貿(mào)易擔(dān)保合同模板下載3篇
- 二零二五版地下車(chē)庫(kù)車(chē)位使用權(quán)轉(zhuǎn)讓與租賃合同3篇
- 2025年度綠色能源項(xiàng)目投資合作二零二五年度能源合同4篇
- 2025年度車(chē)展場(chǎng)地租賃及展覽設(shè)計(jì)服務(wù)合同4篇
- 二零二五年度物流數(shù)據(jù)分析與優(yōu)化承包合同4篇
- 2025年度鋁合金裝飾材料定制與銷(xiāo)售合同4篇
- 2025年度環(huán)保型汽車(chē)零部件典當(dāng)借款合同范本4篇
- 個(gè)人自建房產(chǎn)買(mǎi)賣(mài)合同(2024年定制版)版B版
- 2025年度工程監(jiān)理合同書(shū)示范范本4篇
- 2025年度新能源電池車(chē)間承包加工合同4篇
- 人教版初中語(yǔ)文2022-2024年三年中考真題匯編-學(xué)生版-專題08 古詩(shī)詞名篇名句默寫(xiě)
- 2024-2025學(xué)年人教版(2024)七年級(jí)(上)數(shù)學(xué)寒假作業(yè)(十二)
- 山西粵電能源有限公司招聘筆試沖刺題2025
- 醫(yī)療行業(yè)軟件系統(tǒng)應(yīng)急預(yù)案
- 使用錯(cuò)誤評(píng)估報(bào)告(可用性工程)模版
- 《精密板料矯平機(jī) 第2部分:技術(shù)規(guī)范》
- 2024光伏發(fā)電工程交流匯流箱技術(shù)規(guī)范
- 旅游活動(dòng)碳排放管理評(píng)價(jià)指標(biāo)體系構(gòu)建及實(shí)證研究
- 2022年全國(guó)職業(yè)院校技能大賽-電氣安裝與維修賽項(xiàng)規(guī)程
- 2024年黑龍江省政工師理論知識(shí)考試參考題庫(kù)(含答案)
- 四年級(jí)上冊(cè)脫式計(jì)算300題及答案
評(píng)論
0/150
提交評(píng)論