文檔簡介

,Clause 29Clearances, Creepage distances and solid insulation爬電距離、電氣間隙和絕緣穿通距離 (Table 1),Minimum clearance (Table 2),How to find the minimum clearance,Household appliance are in overvoltage category II Select the rated voltage Using the table 1 to find out the rated impulse voltage According to table 2, the minimum clearance could be found by rated impulse voltage,The clearances of four insulation types: Basic insulation Supplementary insulation Reinforced insulation Functional insulation,The clearance of basic insulation,Example 1 : Water kettle Rating : 220 240V 50Hz 2500 3000W,220 240V,Using category II,The rated impulse voltage was 2500V,29.1.1 clearances of basic insulation,The minimum clearances of basic insulation was 1.5mm,Special components for basic insulation,The terminals of tubular sheathed heating elements counted 1mm, if the microenvironment is pollution degree 1.,1mm,Tubular sheathed heating element,Pollution degree 1,29.1.2 clearance of supplement insulation,The minimum clearance is same as the basic insulation,The distance between enclosure and internal wire,29.1.3 clearance of reinforced insulation,The reinforced insulation using the next step for rated impulse voltage.,Between terminal and plastic enclosure,29.1.4 clearance of functional insulation,Between terminals,The functional insulation is between live parts of different potential,PTC Heating element,Hair straighter,PTC heater,Hair straighter assembly,Different types of PTC Heating elements,Internal construction of PTC heating element,The clearance between surfaces of PTC heating elements may be reduced to 1mm,The clearance =1mm,Kapton film,PTC heating plate,Electrode plate,29.2 creepage distances,Step 1 (To find out the pollution degree) Pollution degree 2 applies unless Precautions have been taken to protect the insulation, in which case pollution 1 applies The insulation is subjected to conductive pollution, in which case pollution degree 3 applies Note: The pollution degree should need refer to part 2.,Pollution degree classification,Tracking index (CTI) values Material group I: 600=CTI Material group II: 400=CTI Material group III a: 175 =CTI 400 Material group III b: 100 =CTI175,Step 2 (To find out the material group),Tracking index tester,Tracking index (CTI) values,Minimum creepage distances for basic insulation,The creepage of basic insulation,Example 1: Water kettle Rating : 220 240V 50Hz 2500 3000W,Pollution degree 3 (refer to standard 60335 2 15 ) The microenvironment is pollution degree 3 if the insulation can be polluted by condensation from steam produced during normal use of appliance. Assume the material group is III (the tighten grade) Working voltage is between 125 and =250,The creepage of basic insulation,Minimum creepage distances for functional insulation,Summary of Minimum creepage distances,29.2.1 creepage for basic insulation Lacquered conductors of windings,1.5mm,Creepage distance of winding need not be greater than the associated clearance specified in table 16,Clause 29.2.2,As per clause 29.2.2, the creepage distance of supplementary insulation shall not less than and 2.5mm. The internal wire of micro-switch was not securely fixed that it was possible to be touched by test finger with 2N force. The creepage distance were measured as 0mm,Internal wire shall be access,Clause 29.2.3,The creepage distances of reinforced insulation shall not less than 8mm. As result, the creepage distance was measured 7.5mm between leads of neon lamp and the lamp cover joint.,Leads of neon lamp,Lens,Enclosure,Leon lamp leads,2mm,3mm,2.5m,The creepage distances = 2.5+2+3 = 7.5mm,29.2.4 creepage distances of functional insulation,1.5mm,Clause 29.2.4,PCB Track,A B,B A,B A,29.2.4 creepage distance for function insulation,Creepage distances may be reduced if the appliance complies with clause 19 with the functional insulation short-circuited. For example: Electronic component,Electronic component,The transistor leads limitation of creepage distance,Live Part,Supplementary insulation (1mm),Basic insulation,29.3.1 Material thickness requirement for supplementary insulation (1),Supplementary Insulation,Live Part,Reinforced insulation (2mm),29.3.1 Material thickness requirement for reinforced insulation (1),Reinforced Insulation,Live Part,1st layer insulation,2nd layer insulation,Each of the layers should withstands the electric strength test for supplementary insulation,29.3.2 Material requirement for supplementary insulation (2),Basic insulation,29.3.2 Material requirement for reinforced insulation (2),Live Part,1st layer insulation,2nd layer insulation,3rd layer insulation,Any two layers together should withstands the electric strength test for reinforced insulation, 1mm,Case 1,Clearance,Creepage distance,= 1mm,Case 2,Clearance,Cree

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

最新文檔

評(píng)論

0/150

提交評(píng)論