住宅新風(fēng)系統(tǒng)設(shè)計與施工住宅新風(fēng)系統(tǒng)設(shè)計與施工第1頁新風(fēng)系統(tǒng)常識新風(fēng)系統(tǒng)類型新風(fēng)系統(tǒng)設(shè)計新風(fēng)系統(tǒng)效果評價新風(fēng)設(shè)計常見問題施工常見問題使用常見問題目錄住宅新風(fēng)系統(tǒng)設(shè)計與施工第2頁1、新風(fēng)系統(tǒng)常識1.1新風(fēng)系統(tǒng)由來
1.2新風(fēng)概念1.3
顆粒物對人體健康影響1.4新風(fēng)系統(tǒng)意義目錄住宅新風(fēng)系統(tǒng)設(shè)計與施工第3頁1.1新風(fēng)系統(tǒng)由來
20世紀(jì)70年代石油危機(jī),使得西方社會加強(qiáng)了對建筑節(jié)能重視,提升保溫能力,降低自然通風(fēng)換氣量,對建筑能耗提出更低要求。但從結(jié)果來看,在這些節(jié)能建筑中出現(xiàn)一些以前沒有出現(xiàn)問題,許多人出現(xiàn)頭暈、記憶力降低、工作效率降低,以及患病率增加。幾年后答案揭曉,這是因為室內(nèi)外通風(fēng)量不足而產(chǎn)生,因為這種情況與空調(diào)系統(tǒng)使用同時存在,所以也稱之為“空調(diào)病”。
1、新風(fēng)系統(tǒng)常識住宅新風(fēng)系統(tǒng)設(shè)計與施工第4頁1.1新風(fēng)系統(tǒng)由來
要防止“空調(diào)病”,就需要確保建筑“最小通風(fēng)量”。普通來講這個數(shù)值與人員多少相關(guān),或者按人均風(fēng)量來衡量。各國標(biāo)準(zhǔn)不盡相同,在中國這個數(shù)值定為30m3/(h*人)。不一樣使用情況(辦公、商場、劇場等),不一樣污染情況(吸煙等)人均新風(fēng)量也是不一樣。新風(fēng)系統(tǒng)從公共建筑進(jìn)入民用住宅,形成了家用新風(fēng)系統(tǒng)。1、新風(fēng)系統(tǒng)常識住宅新風(fēng)系統(tǒng)設(shè)計與施工第5頁1.2新風(fēng)概念
新風(fēng)是漢字創(chuàng)造意義,在國外這個名詞就叫“ventilation(通風(fēng))”,就是暖通空調(diào)中通風(fēng),而沒有其它用詞。
原來通風(fēng)概念:是把室外空氣引到室內(nèi),把室內(nèi)空氣排到室外,因為進(jìn)來空氣和排出空氣污染濃度不一樣,所以通風(fēng)能夠降低室內(nèi)空氣中污染物濃度。1、新風(fēng)系統(tǒng)常識住宅新風(fēng)系統(tǒng)設(shè)計與施工第6頁1.2新風(fēng)概念
一樣,通風(fēng)能夠降低室內(nèi)空氣溫度,也能夠降低室內(nèi)空氣濕度。但假如室外空氣中污染濃度大于室內(nèi),則通風(fēng)結(jié)果必定是通風(fēng)會提升室內(nèi)空氣中污染物濃度。一樣通風(fēng)也能夠提升室內(nèi)溫度和濕度。
所以,傳統(tǒng)意義新風(fēng)/通風(fēng)只適合處理污染源自室內(nèi)污染。而不是一個包治百病“靈丹妙藥”,所以,新形式下新風(fēng)概念準(zhǔn)確講應(yīng)該是:把經(jīng)過過濾、加濕/除濕、加溫/制冷后室外空氣稱之為新風(fēng)。1、新風(fēng)系統(tǒng)常識住宅新風(fēng)系統(tǒng)設(shè)計與施工第7頁1.3空氣質(zhì)量等級及顆粒物對人體健康影響1、新風(fēng)系統(tǒng)常識空氣質(zhì)量指數(shù)空氣質(zhì)量指數(shù)等級空氣質(zhì)量指數(shù)
表示顏色對健康影響情況提議采取方法0~50一級優(yōu)綠色空氣質(zhì)量滿意,基礎(chǔ)無空氣污染各類人群可正?;顒?0~100二級良黃色空氣質(zhì)量可接收,但一些污染物可能對極少數(shù)敏感人群健康有較弱影響極少數(shù)敏感人群應(yīng)降低戶外活動101~150三級輕度污染橙色易感人群癥狀有輕度加劇,健康人群出現(xiàn)刺激現(xiàn)象兒童、老年人及心臟病、呼吸系統(tǒng)疾病患者應(yīng)降低長時間、高強(qiáng)度戶外鍛煉151~200四級中度污染紅色深入加重易感人群癥狀,可能對健康人群心臟、呼吸系統(tǒng)有影響兒童、老年人及心臟病、呼吸系統(tǒng)疾病患者應(yīng)防止長時間、高強(qiáng)度戶外鍛煉。
普通人群適量降低戶外活動201~300五級重度污染紫色心臟病和肺病患者癥狀顯著加劇,運動耐受力降低,健康人群普遍出現(xiàn)癥狀老年人和心臟病、肺病患者應(yīng)停留在室內(nèi),停頓戶外活動,普通人群降低戶外活動>300六級嚴(yán)重污染褐紅色健康人群運動耐受力降低,有顯著強(qiáng)烈癥狀,提前出現(xiàn)一些疾病老年人和病人應(yīng)該停留在室內(nèi),防止體力消耗,普通人群應(yīng)防止戶外活動住宅新風(fēng)系統(tǒng)設(shè)計與施工第8頁1.4新風(fēng)系統(tǒng)意義
即使新風(fēng)概念不是很明確,不過大家對新風(fēng)系統(tǒng)了解還是基礎(chǔ)一致,就是能降低室內(nèi)污染濃度,改進(jìn)室內(nèi)空氣質(zhì)量通風(fēng)系統(tǒng)。
西方國家室外空氣質(zhì)量往往較高,所以室外空氣能夠看成是“好空氣”或“新風(fēng)”,但在中國大多數(shù)城市,因為室外PM2.5和其它污染嚴(yán)重,不能把室外空氣當(dāng)做“好空氣”。1、新風(fēng)系統(tǒng)常識住宅新風(fēng)系統(tǒng)設(shè)計與施工第9頁1.4新風(fēng)系統(tǒng)意義
1、新風(fēng)系統(tǒng)常識在中國室內(nèi)空氣質(zhì)量標(biāo)準(zhǔn)要求:經(jīng)過室內(nèi)環(huán)境衛(wèi)生學(xué)研究,提出室內(nèi)污染濃度限值水平和標(biāo)準(zhǔn)測試方法,從而保障室內(nèi)人員健康。
所以,新風(fēng)系統(tǒng)意義是:降低一個污染物代價不能是使另外一個污染物濃度不可控制增加,超出健康標(biāo)準(zhǔn)要求,而是要保障室內(nèi)空氣質(zhì)量水平,使空氣有利居住者健康。住宅新風(fēng)系統(tǒng)設(shè)計與施工第10頁2、新風(fēng)系統(tǒng)類型2.1窗式新風(fēng)系統(tǒng)2.2單向流新風(fēng)系統(tǒng)2.3雙向流新風(fēng)系統(tǒng)目錄住宅新風(fēng)系統(tǒng)設(shè)計與施工第11頁2.1窗式新風(fēng)系統(tǒng)(無管式單向流)2、新風(fēng)系統(tǒng)類型臥室安裝動力通風(fēng)器,客廳安裝自然或電動通風(fēng)器,經(jīng)過衛(wèi)生間或者廚房排風(fēng),實現(xiàn)氣體循環(huán)流,形成窗式新風(fēng)系統(tǒng)。缺點是只能簡單除大顆粒塵埃。住宅新風(fēng)系統(tǒng)設(shè)計與施工第12頁2.1窗式新風(fēng)系統(tǒng)(無管式單向流)2、新風(fēng)系統(tǒng)類型住宅新風(fēng)系統(tǒng)設(shè)計與施工第13頁2.2管道式單向流新風(fēng)系統(tǒng)2、新風(fēng)系統(tǒng)類型
管道式單向流新風(fēng)系統(tǒng):排風(fēng)口安裝在廚房、衛(wèi)生間等污濁空氣積聚地方,污濁空氣經(jīng)過排風(fēng)機(jī)集中排至室外。需要保持室內(nèi)清新臥室、客廳窗戶上方安裝進(jìn)風(fēng)口,室外空氣經(jīng)過進(jìn)風(fēng)口處理后流入室內(nèi)。自平衡式進(jìn)風(fēng)口能確保恒定新風(fēng)量,排風(fēng)機(jī)每個管道口上也有平衡裝置,確保恒定排風(fēng)量。安裝簡單適宜裝修后房子,缺點是過濾伎倆比較差,無能量回收。住宅新風(fēng)系統(tǒng)設(shè)計與施工第14頁2.2管道式單向流新風(fēng)系統(tǒng)2、新風(fēng)系統(tǒng)類型住宅新風(fēng)系統(tǒng)設(shè)計與施工第15頁2.3管道式雙向流新風(fēng)系統(tǒng)2、新風(fēng)系統(tǒng)類型
雙向流即“機(jī)械進(jìn)風(fēng),機(jī)械排風(fēng)”系統(tǒng),有一組強(qiáng)制送風(fēng)系統(tǒng)和一組強(qiáng)制排風(fēng)系統(tǒng)組成。與單向流區(qū)分是送風(fēng)形式由自然風(fēng)改為機(jī)械送風(fēng),室外空氣由送風(fēng)系統(tǒng)管道進(jìn)入室內(nèi),排風(fēng)經(jīng)過排風(fēng)系統(tǒng)管道排至室外,新風(fēng)及排風(fēng)流動方向、新風(fēng)口及排風(fēng)口布置,能夠依據(jù)特定要求進(jìn)行布置。雙向流分無熱回收和有熱回收兩種設(shè)備,普通都會在機(jī)器進(jìn)風(fēng)和排風(fēng)之間設(shè)置熱回收器,回收顯熱和全熱(顯熱+潛熱)。住宅新風(fēng)系統(tǒng)設(shè)計與施工第16頁2.3管道式雙向流新風(fēng)系統(tǒng)2、新風(fēng)系統(tǒng)類型住宅新風(fēng)系統(tǒng)設(shè)計與施工第17頁2.3墻裝式雙向流新風(fēng)系統(tǒng)2、新風(fēng)系統(tǒng)類型住宅新風(fēng)系統(tǒng)設(shè)計與施工第18頁3、新風(fēng)系統(tǒng)設(shè)計3.1設(shè)計基礎(chǔ)要素3.2新風(fēng)量確定3.3新風(fēng)負(fù)荷計算3.4新風(fēng)系統(tǒng)形式選擇
3.5新風(fēng)設(shè)備選擇
3.6新風(fēng)設(shè)備布置目錄住宅新風(fēng)系統(tǒng)設(shè)計與施工第19頁3.1設(shè)計基礎(chǔ)要素
標(biāo)準(zhǔn)一:定義新風(fēng)路徑——新風(fēng)從空氣潔凈區(qū)域進(jìn)入,由污濁處排出,確定合理氣流組織。標(biāo)準(zhǔn)二:確定房屋內(nèi)最小排風(fēng)量——滿足大家日常工作、休息時所需新鮮空氣量。標(biāo)準(zhǔn)三:定義新風(fēng)時間——確保新風(fēng)連續(xù)性,一年365天,天天24小時連續(xù)不停通風(fēng)。住宅新風(fēng)系統(tǒng)設(shè)計與施工第20頁3.2新風(fēng)量確實定確定新風(fēng)量依據(jù):①衛(wèi)生要求;②補(bǔ)充局部排風(fēng)量;③保持空調(diào)房間“正壓”要求。
普通選擇新風(fēng)量采取以下兩種方法:①最小新風(fēng)量;②換氣次數(shù)。①最小新風(fēng)量法:新風(fēng)量(m3/h)=(建筑面積/單位面積人數(shù))×每人每小時最小新風(fēng)量(m3/人.h)-1②換氣次數(shù)法:新風(fēng)量(m3/h)=房間內(nèi)空間體積(m3)
×換氣次數(shù)兩種方法計算出結(jié)果取最大值作為房間新風(fēng)量。住宅新風(fēng)系統(tǒng)設(shè)計與施工第21頁3.2新風(fēng)量確實定居住建筑每小時換氣次數(shù)(摘自《民用建筑新風(fēng)系統(tǒng)工程技術(shù)規(guī)程》CECS439:)人均居住面積Fp(㎡)每小時換氣次數(shù)Fp≥100.710<Fp≤200.620<Fp≤500.5Fp>500.45住宅新風(fēng)系統(tǒng)設(shè)計與施工第22頁3.3新風(fēng)負(fù)荷計算空調(diào)新風(fēng)負(fù)荷計算計算公式:
QW=GW(iw–in)式中Qw---新風(fēng)負(fù)荷,kw;Gw---新風(fēng)量,kg/s;iw---室外空氣焓值,kJ/kg;in---室內(nèi)空氣焓值,kJ/kg。住宅新風(fēng)系統(tǒng)設(shè)計與施工第23頁3.3新風(fēng)負(fù)荷計算室內(nèi)干球溫度24℃室內(nèi)干球溫度25℃室內(nèi)干球溫度26℃室內(nèi)干球溫度28℃相對濕度50%相對濕度55%相對濕度60%相對濕度50%相對濕度55%相對濕度60%相對濕度50%相對濕度55%相對濕度60%相對濕度65%相對濕度55%相對濕度60%相對濕度65%北京35.3532.429.9632.3229.7327.129.7226.9424.1421.3421.0617.9上海42.5140.137.7140.0237.4434.8737.4134.6931.9629.2328.8825.8天津36.4234.0131.6233.9331.3528.7831.3228.625.8723.1422.7919.71石家莊37.6135.1437.735.0632.4729.8432.4629.6826.8824.0823.820.64太原23.6921.0718.4521.0718.2715.4718.3415.3512.49.399.225.85呼和浩特14.511.688.8311.728.725.718.865.772.44///沈陽30.4928.0225.5827.9425.3527.7225.3422.5619.7616.9616.6813.52大連28.926.4323.9926.3523.7621.1323.7520.9718.1715.3715.0911.93長春25.9723.4820.9623.420.7518.0820.7417.9115.0612.2111.968.72哈爾濱22.7620.2717.7520.1917.5414.8717.5314.711.8598.755.51全國主要城市夏季1kg/s新風(fēng)量新風(fēng)負(fù)荷值/KW住宅新風(fēng)系統(tǒng)設(shè)計與施工第24頁室內(nèi)干球溫度24℃室內(nèi)干球溫度25℃室內(nèi)干球溫度26℃室內(nèi)干球溫度28℃相對濕度50%相對濕度55%相對濕度60%相對濕度50%相對濕度55%相對濕度60%相對濕度50%相對濕度55%相對濕度60%相對濕度65%相對濕度55%相對濕度60%相對濕度65%南京43.4241.0138.6240.9338.3535.7838.3235.632.8730.143026.71杭州44.7542.2839.8442.239.6136.9839.636.8234.0231.2230.9427.78合肥43.2840.8138.3740.7338.1435.5138.1335.3532.5529.7529.4726.31福州42.2839.8137.3739.7337.1434.5137.1334.3531.5528.7528.4725.31南昌41.839.3336.8539.2536.6634.0336.6533.8731.0728.2727.9924.83濟(jì)南36.6134.1431.734.0631.4728.8431.4628.6825.8823.0822.819.64鄭州40.4237.9535.5137.8735.2832.6535.2732.4929.6926.8926.6123.45武漢43.2540.7838.3440.738.1135.4838.135.3232.5229.7229.4426.28長沙37.4234.9532.5134.8732.2829.6532.2729.4926.6923.8923.6120.45廣州43.2340.7638.3240.6838.0935.4638.0835.332.529.729.4226.26???1.8539.3836.9439.336.7134.0836.733.9231.1228.3228.0424.88南寧39.3336.8634.4236.7834.1931.5634.1831.428.625.825.5222.36成都37.7135.2432.6835.1932.4629.7432.5129.626.723.7723.5720.25重慶39.3336.8434.3236.7634.1131.4434.131.2728.4225.5725.3222.08貴陽23.9321.1118.2621.1518.1515.1418.2915.211.878.668.614.99西安3431.5328.9731.4828.7526.0328.825.8922.9920.0619.8616.54銀川19.5516.7313.8816.7713.7710.7613.9110.827.794.284.230.61住宅新風(fēng)系統(tǒng)設(shè)計與施工第25頁3.4新風(fēng)系統(tǒng)形式選擇
新風(fēng)經(jīng)全熱交換器處理后送入室內(nèi):
室外新風(fēng)經(jīng)全熱交換器(ECO-V)進(jìn)行預(yù)冷/預(yù)熱后,接至室內(nèi)機(jī)或者是直接送入室內(nèi)。,ECO-V全熱交換器熱交換效率平均為75%,比常規(guī)節(jié)能28%,而且降低了整個系統(tǒng)空調(diào)負(fù)荷和設(shè)備費用,ECO-V運行費用很低(m3/hECO-V耗電為0.92KW),極大地節(jié)約了用戶負(fù)擔(dān)。
住宅新風(fēng)系統(tǒng)設(shè)計與施工第26頁3.4新風(fēng)設(shè)計
全熱交換器有各種運行模式:依據(jù)需要能夠正壓送風(fēng)也能夠負(fù)壓送風(fēng),并可設(shè)定為全熱交換模式或旁通通風(fēng)模式(新風(fēng)與排氣不進(jìn)行熱交換)。在制冷季節(jié),當(dāng)新風(fēng)溫度低于室內(nèi)溫度時,ECO-V自動由全熱交換模式轉(zhuǎn)換為旁通通風(fēng)模式,使引入新風(fēng)不與室內(nèi)排風(fēng)進(jìn)行全熱交換,直接引入室外新風(fēng),節(jié)約室內(nèi)機(jī)負(fù)荷,當(dāng)新風(fēng)溫度高于室內(nèi)溫度時,ECO-V再切換至全熱交換模式。在設(shè)計使用中應(yīng)注意以下幾點:a.在一些場所假如排風(fēng)中含有細(xì)菌和異味,輕易將其傳至送風(fēng)系統(tǒng)中,造成二次污染,此時不可采取ECO-V全熱交換器。b.要注意送、回風(fēng)口不要太靠近,普通距離大于1.5m(住宅)以上,而且在不一樣方向,以免氣流短路,影響新風(fēng)效果。住宅新風(fēng)系統(tǒng)設(shè)計與施工第27頁3.6新風(fēng)設(shè)備布置
住宅新風(fēng)系統(tǒng)設(shè)計與施工第28頁3.5新風(fēng)設(shè)備選擇
3.5.1設(shè)備選擇:依據(jù)空間最小新風(fēng)量或者換氣次數(shù)選擇適當(dāng)設(shè)備容量。對于中央空調(diào)配套新風(fēng)設(shè)備有以下兩種方式供選擇:a〉全熱交換器;b〉新風(fēng)機(jī)。a〉全熱交換器b〉新風(fēng)機(jī)全熱交換器容量:120㎡房間,成本:5000元左右新風(fēng)機(jī)(無熱交換):120㎡房間,成本:2200左右3.1設(shè)計基礎(chǔ)要素住宅新風(fēng)系統(tǒng)設(shè)計與施工第29頁3.5.2風(fēng)管尺寸確實定管徑確實定:管道采取軟管與硬管結(jié)合,普通室內(nèi)排風(fēng)管道采用DN110及DN75UPVC塑料硬管貼頂安裝,各硬管間及與主機(jī)采取DN125及DN80雙層復(fù)合軟管相連。住宅新風(fēng)系統(tǒng)設(shè)計與施工第30頁1)簡略估算法(方案初設(shè)階段)3.5.3風(fēng)管阻力計算住宅新風(fēng)系統(tǒng)設(shè)計與施工第31頁3.5.4風(fēng)管阻力校核2)準(zhǔn)確計算法(施工圖階段):依據(jù)平面圖管道布置,確定計算最不利管路1、摩擦阻力
Pm=Rm*L
Rm為單位管長摩擦阻力損失,Pa/m2、局部阻力Pj該項目中包含散流器或送風(fēng)百葉,新風(fēng)進(jìn)風(fēng)百葉,調(diào)整風(fēng)閥頭,分流三通,漸縮管,過濾網(wǎng)局部阻力,以最不利管路計算3、總阻力P=Pm+Pj經(jīng)過風(fēng)阻計算,選擇風(fēng)機(jī)風(fēng)壓,標(biāo)準(zhǔn)是:風(fēng)阻小于選取設(shè)備機(jī)外靜壓住宅新風(fēng)系統(tǒng)設(shè)計與施工第32頁3.6新風(fēng)設(shè)備布置
送風(fēng)口位置:房間中新風(fēng)送風(fēng)口供給有以下三種方式:①直接送到風(fēng)機(jī)盤管吸入段,與房間回風(fēng)混合后再被風(fēng)機(jī)盤管冷卻(或加熱)送入室內(nèi)。②新風(fēng)與風(fēng)機(jī)盤管送風(fēng)并聯(lián)送出,能夠混合后再送出。③也能夠各自單獨送入室內(nèi)。進(jìn)風(fēng)口位置:⑴應(yīng)設(shè)在室外較潔凈地點,進(jìn)風(fēng)口處室外空氣有害物含量不應(yīng)大于室內(nèi)作業(yè)地點最高允許濃度30%。⑵布置時要使排風(fēng)口和進(jìn)風(fēng)口盡可能遠(yuǎn)離。進(jìn)風(fēng)口應(yīng)低于排出有害物排風(fēng)口。應(yīng)防止進(jìn)風(fēng)、排風(fēng)短路。⑶為了防止吸入室外地面灰塵,進(jìn)風(fēng)口底部距室外地坪不宜低于2m;布置在綠化地帶時,也不宜低于1m。住宅新風(fēng)系統(tǒng)設(shè)計與施工第33頁3.6新風(fēng)設(shè)備布置
住宅新風(fēng)系統(tǒng)設(shè)計與施工第34頁4、新風(fēng)系統(tǒng)效果評價4.1新風(fēng)風(fēng)量測量4.2室內(nèi)空氣質(zhì)量測量目錄住宅新風(fēng)系統(tǒng)設(shè)計與施工第35頁4.1新風(fēng)風(fēng)量測量4、新風(fēng)系統(tǒng)效果評價
新風(fēng)風(fēng)量測量分為兩種,一個是實際風(fēng)量,也就是測量風(fēng)口處風(fēng)量;一個是測量效果計算“有效風(fēng)量”。后者小于前者,二者之間比值為效率。
假如新風(fēng)系統(tǒng)按空調(diào)標(biāo)準(zhǔn)(也就是新風(fēng)量)則需要測試實際風(fēng)量,而假如按空氣質(zhì)量標(biāo)準(zhǔn)話,則按后者測試?!坝行эL(fēng)量”不是測實際風(fēng)量,而是測量污染物濃度改變速度,進(jìn)而推導(dǎo)出“有效換氣次數(shù)”,乘以實際體積,得到“有效風(fēng)量”。住宅新風(fēng)系統(tǒng)設(shè)計與施工第36頁4.2室內(nèi)空氣質(zhì)量測量4、新風(fēng)系統(tǒng)效果評價
空氣質(zhì)量測量分為兩個參數(shù):一是可到達(dá)最低(平衡)濃度,二是到達(dá)最低濃度需要時間。按不變條件測試污染改變濃度,發(fā)覺濃度速度改變展現(xiàn)先先高后低情況,當(dāng)初間長到一定程度后,濃度隨時間改變越來越小。這時測到濃度就是最低(平衡)濃度,這個時間與換氣次數(shù)相關(guān),普通可認(rèn)為等于3/n(n為換氣次數(shù),h-1)
對應(yīng)市內(nèi)釋放量不變污染源,不一樣新風(fēng)量(換氣次數(shù))對用不一樣最低(平衡)濃度,其值等于M/G,其中M為每小時釋放污染物量(mg/(m3*h)),G為通風(fēng)換氣量m3/h。
能夠依據(jù)測試中得到改變情況,對實際污染源、建筑自然通風(fēng)、機(jī)械通風(fēng)情況進(jìn)行判斷,制訂最正確運行策略,到達(dá)健康、舒適、節(jié)能效果。住宅新風(fēng)系統(tǒng)設(shè)計與施工第37頁5、新風(fēng)設(shè)計常見問題5.1怎樣選擇管道管徑5.2回風(fēng)口設(shè)置5.3氣流組織設(shè)計目錄住宅新風(fēng)系統(tǒng)設(shè)計與施工第38頁5.1怎樣選擇管道管徑5、新風(fēng)設(shè)計常見問題經(jīng)驗數(shù)據(jù):建筑面積120㎡~150㎡,管道干管普通為DN125~150,房間支管DN75;建筑面積<120㎡,管道干管普通為DN100,房間支管DN75;在結(jié)構(gòu)施工時能夠依次預(yù)留過梁洞或者過墻洞。住宅新風(fēng)系統(tǒng)設(shè)計與施工第39頁5.2排風(fēng)口設(shè)置5、新風(fēng)設(shè)計常見問題
每個房間是都設(shè)排風(fēng)口,可能造成新風(fēng)量不足,而按攝影應(yīng)標(biāo)準(zhǔn),各房間門下部應(yīng)有一定間隔(1~3cm),這么就不會造成沒有通風(fēng)情況。理論上講,假如安裝可調(diào)送風(fēng)口,所以每個風(fēng)口風(fēng)量能夠調(diào)整,而每個回風(fēng)口風(fēng)量則是依據(jù)阻力自動平衡,所以,假如每個房間都安裝送回風(fēng)口,可能是不衡。
從排污效果上看,標(biāo)準(zhǔn)上排風(fēng)口布置在能夠排除較多污染物,比如靠近衛(wèi)生間/廚房近公共部位,以到達(dá)很好使用效果。住宅新風(fēng)系統(tǒng)設(shè)計與施工第40頁5.2排風(fēng)口設(shè)置5、新風(fēng)設(shè)計常見問題住宅新風(fēng)系統(tǒng)設(shè)計與施工第41頁5.3氣流組織設(shè)計(ε=室內(nèi)排除氣體濃度/室內(nèi)污染濃度)5、新風(fēng)設(shè)計常見問題假定室內(nèi)污染濃度與排除濃度相等,即ε=1,不過實際排除濃度與新風(fēng)氣流組織方式相關(guān),上圖中為不一樣氣流方式污染濃度分別情況,氣流組織形式住宅新風(fēng)系統(tǒng)設(shè)計與施工第42頁6、施工常見問題6.1使用小口徑風(fēng)管6.2管罩選取6.3保溫管道目錄住宅新風(fēng)系統(tǒng)設(shè)計與施工第43頁6.1使用小口徑風(fēng)管6、施工常見問題
許多安裝隊從省事角度出發(fā),喜歡使用小口徑送風(fēng)管,即使新風(fēng)也能送到房間,不過這么做后果以下:1)、會大大降低風(fēng)量:因為一樣風(fēng)量使用不一樣直徑管道,其阻力相差巨大。以150m3/h風(fēng)量計算,使用DN75,DN100和DN150管道,每米直管道阻力分別為:0.56pa/m,3.9pa/m,15.4pa/m。以80pa機(jī)器風(fēng)壓計算,使用上面管道可輸送最長直線距離為143m,21m,5.2m。因為2)、會產(chǎn)生噪音:因為管道管徑變小,管道內(nèi)風(fēng)速變大,造成空氣與管道內(nèi)壁摩擦加大產(chǎn)生噪音,尤其是在管道拐彎處。住宅新風(fēng)系統(tǒng)設(shè)計與施工第44頁6.2管罩選取6、施工常見問題
室外管罩標(biāo)準(zhǔn)上應(yīng)安裝在輕易清掃地方,普通提議六個月清掃一次。帶防蟲網(wǎng)管罩更輕易被楊柳絮等糊死,在不利清掃地方不提議使用。一旦管罩被堵,通風(fēng)換氣量就會大大降低,嚴(yán)重影響使用效果。住宅新風(fēng)系統(tǒng)設(shè)計與施工第45頁6.3保溫管道6、施工常見問題
對嚴(yán)寒和嚴(yán)寒地域,機(jī)器對外兩個接口管都應(yīng)該使用保溫管道,以預(yù)防在管道外壁結(jié)露。
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 人工拆搬合同范本
- 亞馬遜采購合同范例
- 書畫掛牌合同范例
- 醫(yī)療技術(shù)入股合同范本
- 供應(yīng)化糞池銷售合同范本
- 資金入股合同范本
- 2025年度建筑工程施工安全檢測合同范本
- 商業(yè)房屋全裝修短期租賃合同范本
- 會務(wù)承包服務(wù)合同范本
- 農(nóng)村股追加合同范本
- 2025年湖南九嶷職業(yè)技術(shù)學(xué)院高職單招職業(yè)技能測試近5年??及鎱⒖碱}庫含答案解析
- 農(nóng)產(chǎn)品貯運與加工考試題(附答案)
- 幼兒園開學(xué)教職工安全教育培訓(xùn)
- 學(xué)校財務(wù)年終工作總結(jié)4
- 生態(tài)安全課件
- 鋼鐵是怎樣煉成的鋼鐵讀書筆記
- 2025年汽車加氣站作業(yè)人員安全全國考試題庫(含答案)
- 化工過程安全管理導(dǎo)則安全儀表管理課件
- 中國高血壓防治指南-解讀全篇
- 2024年監(jiān)控安裝合同范文6篇
- 2024年山東省高考政治試卷真題(含答案逐題解析)
評論
0/150
提交評論