慶華·長安家園地下車庫安裝施工組織設(shè)計(jì)樣本_第1頁
慶華·長安家園地下車庫安裝施工組織設(shè)計(jì)樣本_第2頁
慶華·長安家園地下車庫安裝施工組織設(shè)計(jì)樣本_第3頁
慶華·長安家園地下車庫安裝施工組織設(shè)計(jì)樣本_第4頁
慶華·長安家園地下車庫安裝施工組織設(shè)計(jì)樣本_第5頁
已閱讀5頁,還剩36頁未讀, 繼續(xù)免費(fèi)閱讀

下載本文檔

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報(bào)或認(rèn)領(lǐng)

文檔簡介

慶華·長安家園地下車庫安裝施工組織設(shè)計(jì)編制單位:中天西北投資建設(shè)集團(tuán)有限公司編制日期:6月15日編制人:審核人:審批人:慶華·長安家園地下車庫施工組織設(shè)計(jì)目錄工程簡介編制根據(jù)································2工程概況································2工程特點(diǎn)································3-6質(zhì)量籌劃、質(zhì)量通病防治辦法質(zhì)量管理目的、通病防治辦法·······················6-8工程質(zhì)量檢查與驗(yàn)收···························8施工組織及施工布置施工組織及準(zhǔn)備·····························8-9施工布置原則······························9施工前準(zhǔn)備·······························9-10施工配合································10-12施工進(jìn)度籌劃施工程序及施工要點(diǎn)總體規(guī)定································12施工程序及施工規(guī)定電氣工程安裝······························12-18給排水及消防水系統(tǒng)工程安裝·······················18-20采暖系統(tǒng)安裝······························20-22通風(fēng)空調(diào)工程安裝····························22-24節(jié)能工程································24工程技術(shù)、質(zhì)量、安全辦法工程技術(shù)管理·······························24施工管理·································24-25技術(shù)辦法·································25-26質(zhì)量保證辦法·······························26-27質(zhì)量管理點(diǎn)管理辦法···························27安全技術(shù)辦法·······························27-29消防保衛(wèi)辦法·······························29夏、雨季施工辦法·····························29-30現(xiàn)場文明施工辦法·····························30工程技術(shù)資料管理····························30竣工圖編制、審核與移送·························30-31竣工驗(yàn)收·······························31成品保護(hù)一、設(shè)備及安裝成品保護(hù)····························31人工器具及二次深化設(shè)計(jì)附表一、工程籌劃投入人數(shù)籌劃表··························31二、重要施工機(jī)具需用籌劃表··························32三、車庫管道、橋架深化排列布置圖·······················33-36第一章工程簡介一、編制根據(jù):本施工組織設(shè)計(jì)編制根據(jù)慶華·長安家園地下車庫工程施工圖紙、圖紙會審紀(jì)要等關(guān)于資料;國家頒發(fā)關(guān)于施工規(guī)范和設(shè)計(jì)原則;地方政府所頒發(fā)施工規(guī)范和原則;我公司質(zhì)量體系各文獻(xiàn)《質(zhì)量手冊》、《管理文獻(xiàn)》、《技術(shù)原則》等有關(guān)內(nèi)容;我公司承建類似工程施工經(jīng)驗(yàn)資料等編制而成。二、工程概況:1、工程名稱:慶華·長安家園地下車庫2、工程地點(diǎn):西安市灞橋區(qū)當(dāng)代紡織產(chǎn)業(yè)園灞河?xùn)|岸3、工程概況:本工程為地下停車庫,框架構(gòu)造。安裝工程涉及生活用給排水系統(tǒng)、電氣動(dòng)力照明系統(tǒng)、基本接地系統(tǒng)、通風(fēng)采暖系統(tǒng)、弱電系統(tǒng)等。4、建設(shè)單位:西安鼎銘置業(yè)有限公司5、設(shè)計(jì)單位:西部建筑抗震勘察設(shè)計(jì)研究院6、監(jiān)理單位:陜西東龍建設(shè)監(jiān)理有限責(zé)任公司7、總包單位:中天西北建設(shè)投資集團(tuán)有限公司8、質(zhì)量目的:保證合格,創(chuàng)立優(yōu)質(zhì)工程、文明工地。9、工期目的:保證與土建同步,力求提前。4、本工程編制根據(jù)及采用規(guī)范、原則如下:(1)建筑工程施工質(zhì)量驗(yàn)收統(tǒng)一原則GB50300-;(2)建筑給水排水及采暖工程施工質(zhì)量驗(yàn)收規(guī)范GB50242-;(3)建筑電氣工程施工質(zhì)量驗(yàn)收規(guī)范GB50303-;(4)通風(fēng)與空調(diào)工程施工質(zhì)量驗(yàn)收規(guī)范GB50243-;(5)建筑節(jié)能工程施工質(zhì)量驗(yàn)收規(guī)范GB50411-;(6)火災(zāi)自動(dòng)報(bào)警系統(tǒng)工程施工及驗(yàn)收規(guī)范GB50166-;(7)自動(dòng)噴水滅火系統(tǒng)施工及驗(yàn)收規(guī)范GB50261-;(8)建筑給水排水設(shè)計(jì)規(guī)范GB50015-()(9)火災(zāi)自動(dòng)報(bào)警系統(tǒng)設(shè)計(jì)規(guī)范GB50116-98;(10)建筑設(shè)計(jì)防火規(guī)范GB50016-;(11)民用建筑電氣設(shè)計(jì)規(guī)范JGJ/16-;(12)供配電系統(tǒng)設(shè)計(jì)規(guī)范GB50052-;(13)自動(dòng)噴水滅火系統(tǒng)設(shè)計(jì)規(guī)范GB50084-();(14)低壓配電設(shè)計(jì)規(guī)范GB50054-;(15)汽車庫、修理庫、停車場設(shè)計(jì)防火規(guī)范GB50067-97;(16)民用建筑供暖通風(fēng)與空氣調(diào)節(jié)設(shè)計(jì)規(guī)范GB50736-;中天建設(shè)集團(tuán)有限公司公司原則ZTB:(1)ZTB202-建筑采暖安裝工程施工工藝原則;(2)ZTB201-建筑給水、排水工程施工工藝原則;(3)ZTB204-建筑電氣工程施工工藝原則;三、工程特點(diǎn):1、生活給排水管道工程a、給水系統(tǒng):1)生活給水管道系統(tǒng)分高、低區(qū),低區(qū)為J1、J2管道,供水壓力為0.75MPa;高區(qū)為J3管道,供水壓力為1.05Mpa.2)給水管道采用鋼塑復(fù)合管,DN≤80時(shí),采用絲扣連接,DN>80時(shí),采用卡箍連接。3)給水鋼塑管道刷綠漆兩道。管道系統(tǒng)實(shí)驗(yàn)壓力表系統(tǒng)名稱壓力(MPa)給水低區(qū)給水高區(qū)工作壓力0.751.05強(qiáng)度實(shí)驗(yàn)壓力1.1251.575嚴(yán)密性壓力0.861.2b、排水系統(tǒng):1)地面沖洗水就近排入集水坑由潛水泵提高就近排至室外污水井。2)潛水排污泵出口一段管道采用夾布橡膠軟管,別的采用焊接鋼管,焊接連接。3)金屬管道、管件、埋件及支吊架刷樟丹兩道,銀粉兩道防腐。c、消火栓系統(tǒng):消火栓管道均采用內(nèi)外熱鍍鋅鋼管,DN≤80時(shí),絲扣連接,DN>80時(shí),卡箍連接。室內(nèi)消火栓(均采用減壓穩(wěn)壓消火栓)選用SN65型,QZ19/¢19,襯膠水帶25m。消防管道刷紅丹防銹漆兩道。d、噴淋系統(tǒng):地下車庫按中危險(xiǎn)級Ⅱ級設(shè)計(jì),噴淋強(qiáng)度為8L/min.m2,作用面積為160m2,滅火用水量為30L/S。車庫鋼構(gòu)層采用直立型68°C玻璃球噴頭,向上安裝;地面層采用下垂型68°C玻璃球噴頭(帶集熱罩),向下安裝。車庫中寬度不不大于等于1.2米通風(fēng)管道下方增設(shè)下垂型噴頭,詳細(xì)安裝如下圖:圖1圖2自噴管道系統(tǒng)采用內(nèi)外熱鍍鋅鋼管,DN≤80時(shí),采用絲扣連接,DN>80時(shí),采用卡箍連接。管道實(shí)驗(yàn)壓力表系統(tǒng)名稱壓力(MPa)消火栓系統(tǒng)自動(dòng)噴水系統(tǒng)工作壓力1.20.45強(qiáng)度實(shí)驗(yàn)壓力1.61.4嚴(yán)密性壓力1.20.452、通風(fēng)采暖工程a、通風(fēng)及排煙系統(tǒng):1)地下車庫設(shè)排風(fēng)兼排煙系統(tǒng)和送風(fēng)系統(tǒng),送風(fēng)量不不大于排煙量50%。平時(shí)風(fēng)機(jī)定期運(yùn)轉(zhuǎn),對地下汽車庫進(jìn)行通風(fēng),火災(zāi)時(shí)由消防中心控制風(fēng)機(jī)運(yùn)轉(zhuǎn),對地下汽車庫進(jìn)行排煙和補(bǔ)風(fēng)。2)風(fēng)管材料采用鍍鋅鋼板制作,厚度按《通風(fēng)與空調(diào)工程施工質(zhì)量驗(yàn)收規(guī)范》(GB50243-)表4.2.1-1規(guī)定執(zhí)行。如下:鋼板風(fēng)管板材厚度(mm) 類別風(fēng)管直徑D或長邊尺寸b圓形風(fēng)管矩形風(fēng)管除塵系統(tǒng)風(fēng)管中低壓系統(tǒng)高壓系統(tǒng)D(b)≤3200.50.50.751.5320<D(b)≤4500.60.60.751.5450<D(b)≤6300.750.60.752.0630<D(b)≤10000.750.751.02.01000<D(b)≤12501.01.01.02.01250<D(b)≤1.21.01.2按設(shè)計(jì)<D(b)≤4000按設(shè)計(jì)1.2按設(shè)計(jì)3)安裝風(fēng)管時(shí)風(fēng)管長邊>630mm風(fēng)管,當(dāng)每節(jié)長度>1200mm時(shí),風(fēng)管壁上應(yīng)加工對角凸棱;風(fēng)管長邊>500mm彎頭設(shè)導(dǎo)流葉片,風(fēng)機(jī)軟接頭為150~200mm長不燃軟接,軟接頭連接應(yīng)嚴(yán)密,在軟接頭處不得變徑;風(fēng)管支吊架跨距,不能超過下表規(guī)定:風(fēng)管類型最大跨距圓形風(fēng)管直徑或矩形大邊長度≤400>400水平風(fēng)管4.03.0豎風(fēng)管×4.04.0×豎風(fēng)管支吊架數(shù)量,每條風(fēng)管不能少于兩個(gè)4)風(fēng)機(jī)安裝應(yīng)采用彈性吊架,風(fēng)機(jī)安裝時(shí)應(yīng)注意風(fēng)機(jī)氣流方向與本圖所規(guī)定方向相一致,普通鋼板制作風(fēng)管,配件,金屬支吊架等(鍍鋅鋼板制作者除外)均需進(jìn)行除銹,然后刷樟丹防銹漆兩遍。b、采暖系統(tǒng):1)采暖管道分高區(qū)、低區(qū),管道穿越防火墻體處應(yīng)預(yù)留鋼套管,并在穿墻處設(shè)立固定支架。管道與套管間空隙應(yīng)以耐火材料填封。2)管道采用無縫鋼管,焊接連接,在表面除銹后,刷樟丹防銹漆兩遍。保溫材料采用福耐斯(FLEX-FE)橡塑,厚度32mm,系統(tǒng)安裝完畢后須進(jìn)行水壓實(shí)驗(yàn)。管道實(shí)驗(yàn)壓力表系統(tǒng)名稱壓力(MPa)16#樓采暖系統(tǒng)低區(qū)采暖系統(tǒng)高區(qū)采暖系統(tǒng)工作壓力0.81強(qiáng)度實(shí)驗(yàn)壓力1.01.2嚴(yán)密性壓力0.813、電氣動(dòng)力照明工程a、動(dòng)力、照明系統(tǒng):1)本車庫每個(gè)防火分區(qū)由專用變配電室引來三路低壓電源.分別為照明,動(dòng)力,備用電源,應(yīng)急照明、送風(fēng)機(jī)、排煙風(fēng)機(jī)等為一級負(fù)荷;潛污泵為二級負(fù)荷;別的為三級負(fù)荷。一、二級負(fù)荷供電采用雙回路供電,末端切換。2)地下車庫分兩層,鋼構(gòu)層照明支線穿鋼管,沿頂板,墻暗敷設(shè),地面層沿鋼屋架穿鋼管明配,線管所有采用焊接鋼管、焊接連接。3)重要配電干線沿橋架引至各配電箱,支線沿橋架或穿鋼管敷設(shè),明敷時(shí)做防火解決。金屬橋架上敷設(shè)雙回路電源電纜用隔板隔開,橋架外壁采用刷防火涂料相應(yīng)防火保護(hù)辦法。電纜橋架在穿過防火墻及防火樓板時(shí),應(yīng)采用防火隔離辦法。b、消防電系統(tǒng)1)火災(zāi)自動(dòng)報(bào)警系統(tǒng)保護(hù)級別為一級,采用總線制火災(zāi)報(bào)警控制系統(tǒng)。消防控制室設(shè)在1#樓地上一層,在車道、樓梯口、機(jī)房等位置設(shè)手動(dòng)報(bào)警按鈕及消防對講電話插孔。在消火栓箱內(nèi)設(shè)消火栓報(bào)警按鈕。2)鋼構(gòu)層照明支線穿鋼管,沿頂板,墻暗敷設(shè),地面層沿鋼屋架穿鋼管明配,線管所有采用焊接鋼管、焊接連接,聯(lián)動(dòng)控制總線所有由橋架引至各分派端子箱。c、接地系統(tǒng)1)本工程電氣設(shè)備保護(hù)接地、弱電系統(tǒng)等接地共用統(tǒng)一接地極,規(guī)定接地電阻不不不大于1歐姆,運(yùn)用基本鋼筋作為聯(lián)合接地極。實(shí)測達(dá)不到接地規(guī)定期,增打人工接地極。2)配電系統(tǒng)接地方式采用TN-S系統(tǒng),水平橋架在首端和末端作重復(fù)接地。第二章、質(zhì)量籌劃、質(zhì)量通病防治辦法一、質(zhì)量管理目的、通病防治辦法本工程質(zhì)量管理目的為:保證合格,爭取創(chuàng)立文明工地、優(yōu)質(zhì)工程。為達(dá)到這一目的,建立完善質(zhì)量保證體系及質(zhì)量崗位責(zé)任,加強(qiáng)施工質(zhì)量監(jiān)控管理,設(shè)立項(xiàng)目經(jīng)理全面負(fù)責(zé)工程質(zhì)量,技術(shù)負(fù)責(zé)人協(xié)助項(xiàng)目經(jīng)理搞好質(zhì)量工作,專業(yè)工程師負(fù)責(zé)單項(xiàng)工程質(zhì)量,生產(chǎn)班組對自己所安裝產(chǎn)品質(zhì)量負(fù)責(zé),質(zhì)量檢查監(jiān)督員執(zhí)行一票否決制度,如發(fā)現(xiàn)施工過程中不合格產(chǎn)品,及時(shí)返工整治,不留隱患。每個(gè)分項(xiàng)工程無質(zhì)檢員簽字,不能交下一道工序施工,班組自檢,質(zhì)檢員巡檢,項(xiàng)目經(jīng)理每月組織全面檢查工作貫穿于本工程始終,并把工程質(zhì)量作為獎(jiǎng)金分派重要根據(jù),優(yōu)質(zhì)優(yōu)獎(jiǎng),保證優(yōu)良工程。用全面質(zhì)量管理思想、辦法,使全體人員樹立起質(zhì)量第一觀點(diǎn),實(shí)行全過程質(zhì)量管理,詳細(xì)做到如下幾點(diǎn):1、加強(qiáng)圖紙會審工作,消除質(zhì)量隱患。2、加強(qiáng)技術(shù)培訓(xùn),不斷提高職工技術(shù)素質(zhì),結(jié)合施工需要,事先組織各種培訓(xùn)。3、加強(qiáng)對材料、設(shè)備和半成品采購及貯存管理,采用相應(yīng)技術(shù)管理辦法對其進(jìn)行質(zhì)量控制,禁止使用不合格材料、設(shè)備進(jìn)行安裝。4、材料質(zhì)量控制籌劃:對進(jìn)場材料設(shè)備必要嚴(yán)格進(jìn)行質(zhì)量把關(guān),堅(jiān)持做到事先將生產(chǎn)廠家簡介,材料技術(shù)數(shù)據(jù)和實(shí)驗(yàn)數(shù)據(jù)、材料樣品送交籌建處代表承認(rèn),凡是資料不齊,未經(jīng)批準(zhǔn)材料,一律不準(zhǔn)進(jìn)入施工現(xiàn)場,對用量大而對質(zhì)量有至關(guān)重要材料,除具備上報(bào)各種數(shù)據(jù)外,還必要由工程技術(shù)人員和甲方代表對生產(chǎn)廠家生產(chǎn)工藝,質(zhì)量控制檢測手段等進(jìn)行實(shí)地調(diào)查,直到滿足規(guī)定規(guī)定為止。5、施工過程檢查和質(zhì)量控制籌劃:a、加強(qiáng)對施工操作工藝質(zhì)量控制,嚴(yán)格執(zhí)行施工人員持證上崗制度,逐級做好技術(shù)交底,使施工人員不但明了本工程設(shè)計(jì)意圖,重要特點(diǎn),掌握施工中操作規(guī)程和技術(shù)規(guī)定,并且還必要熟悉本工程質(zhì)量原則進(jìn)行施工,杜絕施工過程中也許浮現(xiàn)質(zhì)量隱患,對重要施工工序基準(zhǔn)軸線定位、管道、設(shè)備預(yù)留孔及預(yù)埋件位置,各種架空管線標(biāo)高及坡度均做到工前檢查,竣工復(fù)核。b、建立質(zhì)量檢查制度,明確提出質(zhì)量控制點(diǎn)和規(guī)定及重要控制點(diǎn)必要達(dá)到質(zhì)量原則。c、對不合格產(chǎn)品控制,一旦發(fā)現(xiàn)材料、施工工藝、工序或分項(xiàng)工程不能滿足設(shè)計(jì)規(guī)定和施工規(guī)范規(guī)定,應(yīng)積極采用辦法。d、糾正辦法:采用糾正辦法之前,應(yīng)查明質(zhì)量問題因素,查找重要因素,采用辦法應(yīng)使損失最小,并制定關(guān)于防止辦法,防止再次發(fā)生。e、做好產(chǎn)品保護(hù)工作。安裝前,各種設(shè)備、材料要有專門庫房、場地存儲,有專人保管,并有完善防雨防盜辦法;對已安裝好產(chǎn)品進(jìn)行妥善保護(hù),采用護(hù)欄、擋蓋、派人值班等辦法,保證將合格產(chǎn)品交到業(yè)主手中。f、及時(shí)辦理設(shè)計(jì)變更和材料代用審批手續(xù),由項(xiàng)目部技術(shù)負(fù)責(zé)人會同設(shè)計(jì)院設(shè)計(jì)人員,甲方代表共同擬定,手續(xù)完備后方可執(zhí)行。g、認(rèn)真組織隱蔽工程驗(yàn)收,由技術(shù)、質(zhì)檢負(fù)責(zé)人和監(jiān)理工程師共同參加,驗(yàn)收合格并簽字蓋章后方可進(jìn)行下道工序施工,同步搞好技術(shù)復(fù)核工作。h、克服質(zhì)量通病和薄弱環(huán)節(jié),加強(qiáng)質(zhì)量通病防治辦法,提高工程質(zhì)量籌劃。1)現(xiàn)場施工常用電氣預(yù)埋風(fēng)機(jī)線管與實(shí)際安裝風(fēng)機(jī)位置不太一致,預(yù)埋線管前需結(jié)合電氣設(shè)計(jì)施工平面圖風(fēng)機(jī)標(biāo)注位置與通風(fēng)平面設(shè)計(jì)圖位置詳細(xì)分析預(yù)埋。2)管路不通,朝上管口末及時(shí)堵好管堵,導(dǎo)致雜物落入管中。應(yīng)在立管時(shí),隨時(shí)堵好管堵,其他工種作業(yè)時(shí),應(yīng)注意不要碰壞已經(jīng)敷設(shè)完畢管路,避免導(dǎo)致管路堵塞。3)開關(guān)、插座面板不平整,與建筑物表面之間有縫隙,安裝時(shí)應(yīng)調(diào)節(jié)面板后再擰緊固定螺絲,使其緊貼建筑物表面。4)電線管在焊跨接地線時(shí),將管焊漏,焊接不牢、漏焊、焊接面不夠倍數(shù),重要是操作者責(zé)任心不強(qiáng),或者技術(shù)水平太低,應(yīng)加強(qiáng)操作者責(zé)任心和技術(shù)教誨、嚴(yán)格按照規(guī)范規(guī)定進(jìn)行焊接;暗配管路彎曲過多,敷設(shè)管路時(shí),應(yīng)按設(shè)計(jì)圖規(guī)定及現(xiàn)場狀況,沿近來路線敷設(shè),不繞行彎曲處可明顯減少。5)管口不平齊有毛刺,斷管后未及時(shí)銑口,應(yīng)用銼把管口銼平齊,去掉毛刺再配管;煨彎處浮現(xiàn)凹扁過大或彎曲半徑不夠倍數(shù)現(xiàn)象。其因素及解決辦法有:a使用手扳煨管器時(shí),移動(dòng)要適度,用力不要過猛。b使用油壓煨管器或煨管機(jī)時(shí),模具要配套,管子焊縫應(yīng)在正反面。6)車庫安裝時(shí)成排燈具中心線偏差超過容許范疇。在擬定成排燈具位置時(shí),必要拉線,最佳拉十字線。7)車庫內(nèi)管道、橋架、風(fēng)管較多,避免安裝過程中交叉較多,安裝前應(yīng)優(yōu)化設(shè)計(jì)管道、橋架和風(fēng)管排布。8)車庫與主樓連接管道順序要相相應(yīng),避免進(jìn)主樓時(shí)管道交叉重疊,安裝前先按主樓管道順序優(yōu)化設(shè)計(jì)排布。9)車庫內(nèi)管道較多,避免支架雜亂,按優(yōu)化設(shè)計(jì)圖進(jìn)行制作支架,同一位置管道盡量采用統(tǒng)一支架。二、工程質(zhì)量檢查與驗(yàn)收工程質(zhì)量檢查與驗(yàn)收,分為工序檢查,分項(xiàng)工程檢查,分部工程檢查和單位工程檢查。按規(guī)定搞好分某些項(xiàng)工程檢查及驗(yàn)收,及時(shí)做好各種施工技術(shù)管理資料安裝記錄,質(zhì)量驗(yàn)收及歸檔工作,繪制與本工程相吻合竣工圖紙,如期將本工程技術(shù)管理資料及竣工圖紙完整地交給業(yè)主和關(guān)于各方。1、工序檢查:班組及班組之間對工序質(zhì)量檢查,普通采用方式是自檢、互檢和專職檢?!白詸z”是起到自我控制作用,“互檢”是操作者之間對所操作工序互相檢查,“專職檢”是專職質(zhì)檢員對工序質(zhì)量檢查。班組自檢→施工員檢查→質(zhì)檢員檢查→工程師檢查→返修整治工程交工驗(yàn)收資料→質(zhì)檢員檢查→公司質(zhì)管部檢查→返修整治2、分項(xiàng)工程檢查:在班組自檢基本上,由施工技術(shù)員組織關(guān)于人員進(jìn)行評估,專職質(zhì)檢員核定。3、分部工程檢查:分部工程檢查與評估是在分項(xiàng)工程評估基本上進(jìn)行,由技術(shù)負(fù)責(zé)人組織評估,專職質(zhì)量檢查員核定。4、單位工程驗(yàn)收:由公司技術(shù)負(fù)責(zé)人組織公司技術(shù)、質(zhì)量、生產(chǎn)等關(guān)于部門到施工現(xiàn)場進(jìn)行檢查,成果送本地質(zhì)監(jiān)部門核定。各分項(xiàng)工程質(zhì)量技術(shù)交底中應(yīng)列條注明各類質(zhì)量通病,并提供防治辦法和辦法。對施工中各薄弱環(huán)節(jié)嚴(yán)格把關(guān),在質(zhì)量驗(yàn)收時(shí)應(yīng)予以注重,以各種有效手段提高工程質(zhì)量。第三章、施工組織及施工布置一、施工組織及準(zhǔn)備:1、熟悉圖紙、設(shè)計(jì)變更及國家和地方原則、規(guī)范,充分理解設(shè)計(jì)意圖。2、協(xié)助建設(shè)單位、監(jiān)理單位做好圖紙會審等工作。3、依照本工程水電安裝內(nèi)容和設(shè)計(jì)特點(diǎn),準(zhǔn)備水電施工材料籌劃,防水套管及墻板留孔、鋼套管制作等管理籌劃和預(yù)埋預(yù)留籌劃,各電氣動(dòng)力導(dǎo)管預(yù)埋敷設(shè)籌劃等。4、在主體構(gòu)造土建與水電同步進(jìn)行狀況下,合理安排施工,按照項(xiàng)目部安排各工種交叉作業(yè)時(shí)間抓緊施工,可在施工前將某些預(yù)埋件一方面制作好備用。做到施工作業(yè)合理有序。5、班組長應(yīng)做到每天做好班前技術(shù),安全交底,班后檢查驗(yàn)收,對各作業(yè)人員進(jìn)行質(zhì)量、安全監(jiān)管。6、安排組織進(jìn)度籌劃,按照整體籌劃進(jìn)度實(shí)行圖紙預(yù)算并做好月報(bào)表。7、安排專人隨工程進(jìn)度收集整頓工程資料,前期預(yù)埋階段資料劃分以土建施工段劃分為準(zhǔn)。主體構(gòu)造封頂后資料以各專業(yè)系統(tǒng)、樓層或施工進(jìn)度劃分。二、施工布置原則:1、依照招標(biāo)文獻(xiàn)及關(guān)于規(guī)范、原則,擬定最合理施工布置和程序,制定合理施工方案和對的工程進(jìn)度籌劃,并合理布置施工現(xiàn)場平面圖。為現(xiàn)場文明施工創(chuàng)造技術(shù)、物資、組織場地等必備條件,以保證開工和施工活動(dòng)順利進(jìn)行。a、成立強(qiáng)有力施工班組,著重做好施工總體規(guī)劃。b、開工前組織熟悉施工圖紙。c、編制好施工組織設(shè)計(jì)、質(zhì)量籌劃,貫徹施工力量,滿足工程施工。d、做好技術(shù)準(zhǔn)備工作:1)組織施工技術(shù)人員學(xué)習(xí)各種原則和規(guī)范,并對施工小組進(jìn)行詳盡書面交底。2、與設(shè)計(jì)單位協(xié)調(diào)a、依照提供施工圖,組織人員熟悉圖紙,并與設(shè)計(jì)院聯(lián)系,做好圖紙交底和會審等工作,進(jìn)一步理解設(shè)計(jì)意圖和工程規(guī)定,依照設(shè)計(jì)意圖提出咱們施工實(shí)行方案。3、與監(jiān)理工程師工作協(xié)調(diào)a、在施工過程中,嚴(yán)格按照施工組織設(shè)計(jì)進(jìn)行質(zhì)量管理,在自檢、專檢基本上,接受監(jiān)理工程師驗(yàn)收和檢查,并按照監(jiān)理規(guī)定,予以整治。b、貫徹已建立質(zhì)量檢查、控制、管理制度,并據(jù)此對工程質(zhì)量予以檢控,保證工程質(zhì)量達(dá)到合格。c、所有進(jìn)入現(xiàn)場使用成品、半成品、設(shè)備、材料、器具均向監(jiān)理工程師提交產(chǎn)品合格證、檢查報(bào)告或質(zhì)保書,應(yīng)按規(guī)定在使用邁進(jìn)行檢測材料,積極遞交檢測成果報(bào)告,使所用材料、設(shè)備不給工程導(dǎo)致?lián)]霍。d、按部位或分項(xiàng)、工序檢查質(zhì)量,嚴(yán)格執(zhí)行“上道工序不合格,下道工序不施工”準(zhǔn)則,使監(jiān)理工程師順利開展工作。三、施工前準(zhǔn)備a、施工力量準(zhǔn)備:依照工程狀況成立安裝管理部,由管理部全面負(fù)責(zé)加強(qiáng)施工現(xiàn)場組織與管理,及時(shí)組織安排勞動(dòng)力進(jìn)行施工。b、技術(shù)準(zhǔn)備工作:1)發(fā)現(xiàn)問題及時(shí)向建設(shè)單位、設(shè)計(jì)院提出,使矛盾盡量在施工前得到解決。2)對各種管道、電管、交叉密集處與構(gòu)造梁、柱、裝飾等走向碰撞均需認(rèn)真考慮,做好合理布置。3)嚴(yán)格執(zhí)行關(guān)于國家規(guī)程、規(guī)范和關(guān)于地方原則,并在此基本上制定相應(yīng)施工技術(shù)辦法。4)依照工程特點(diǎn),編制勞動(dòng)力進(jìn)場籌劃和機(jī)具要料籌劃,并編制合理施工工作籌劃和辦法。5)對進(jìn)場職工進(jìn)行技術(shù)和安全交底,并做好各種培訓(xùn)工作,做到持證上崗,保證施工順利進(jìn)行。6)設(shè)備材料進(jìn)場后,由材料員、施工員同業(yè)主及監(jiān)理工程師做好質(zhì)量驗(yàn)收工作,并做好記錄,關(guān)于人員簽字承認(rèn)。四、施工配合:1、電氣動(dòng)力工程施工現(xiàn)場配合a、電線管預(yù)埋、橋架或金屬線槽穿墻或過樓板洞、預(yù)埋固定吊支架用鐵件,由電氣專業(yè)人員配合土建專業(yè)施工。b、消防系統(tǒng)排煙風(fēng)機(jī),有運(yùn)用構(gòu)造風(fēng)道進(jìn)行加壓送風(fēng)或排煙,因而構(gòu)造風(fēng)道砌筑時(shí),內(nèi)壁縫隙應(yīng)封堵嚴(yán)實(shí),防止構(gòu)造風(fēng)道內(nèi)壁漏風(fēng);同步規(guī)定風(fēng)道內(nèi)壁表面抹灰平整,目是減小風(fēng)阻力;各層風(fēng)口預(yù)留孔洞尺寸與生產(chǎn)廠家產(chǎn)品風(fēng)口安裝尺寸相符,保證構(gòu)造風(fēng)道上風(fēng)口不剔鑿修補(bǔ)。2、電氣照明工程施工現(xiàn)場配合a、配合土建構(gòu)造施工以施工圖為根據(jù)預(yù)留孔洞、預(yù)埋鐵件;擬定箱(盒)規(guī)格型號,按照箱(盒)幾何尺寸制作箱(盒)套。b、預(yù)留盒(箱)孔洞標(biāo)高、坐標(biāo)應(yīng)符合施工圖規(guī)定,同步找土建放線人員確認(rèn)建筑基準(zhǔn)點(diǎn)后再定位,防止對基準(zhǔn)點(diǎn)未找對,放錯(cuò)線,導(dǎo)致返工修改孔洞等后果。c、暗配管施工根據(jù)施工圖中盒(箱)起點(diǎn)與終點(diǎn)位置,找出干管與支管路線,根據(jù)土建設(shè)立基準(zhǔn)點(diǎn),放線測量,下料配管。d、在樓板中配管,應(yīng)在上下層鋼筋中間穿行。當(dāng)管路較多時(shí),如消防報(bào)警管路、弱電管路發(fā)生交叉重疊狀況,應(yīng)及時(shí)找各專業(yè)負(fù)責(zé)人協(xié)調(diào),設(shè)法錯(cuò)開位置,防止重疊后高出樓板厚度。配管之間,管與盒(箱)之間應(yīng)綁扎牢固。e、在墻體鋼筋網(wǎng)中配管,應(yīng)注意管與管之間、管與盒(箱)之間固定牢固,核心是各種開關(guān)盒、標(biāo)高、坐標(biāo)位置應(yīng)符合設(shè)計(jì)規(guī)定及現(xiàn)行國標(biāo)施工驗(yàn)收規(guī)范規(guī)定。f、檢查預(yù)埋盒(箱)孔洞尺寸、標(biāo)高、位置,與否有歪斜位移、標(biāo)高不一致,發(fā)現(xiàn)問題及時(shí)修復(fù)。g、檢查燈頭盒、開關(guān)盒、插座盒、插座箱、照明配電箱等,盒(箱)收口與否平整或尚未做收口工作,應(yīng)及時(shí)找土建專業(yè)協(xié)助盒(箱)收口。3、火災(zāi)自動(dòng)報(bào)警及消防聯(lián)動(dòng)控制系統(tǒng)工程現(xiàn)場配合a、消防水、電專業(yè)各自根據(jù)施工圖進(jìn)行預(yù)留孔洞、預(yù)埋鐵件。擬定盒(箱)規(guī)格型號、幾何尺寸,制作盒(箱)套,材質(zhì)可用木質(zhì)或鋼質(zhì)制成套盒(箱),及時(shí)配合土建構(gòu)造施工,安裝好盒(箱)套。b、在底板或墻體配筋處,需要割斷鋼筋時(shí),向土建構(gòu)造負(fù)責(zé)人提前報(bào)告,擬定解決方案,禁止擅自割斷鋼筋。c、暗埋管路超長時(shí),按現(xiàn)行關(guān)于國標(biāo)和規(guī)范增長接線盒,所增長接線盒位置,必要在施工圖上標(biāo)注清晰,防止穿線或換線時(shí)給尋找。在配管時(shí),躲開其他專業(yè)設(shè)備洞和設(shè)備基本,避免日后拆改返工。d、暗埋管路密集部位,施工中及時(shí)在施工圖上劃清詳細(xì)坐標(biāo)位置,在裝修施工過程中,向其他專業(yè)施工人員提示,打孔洞時(shí)盡量避開這一部位,防止將暗埋管路打斷e、各種探測器安裝,應(yīng)考慮施工現(xiàn)場建筑垃圾清理干凈,各專業(yè)施工已進(jìn)入尾聲時(shí),再安裝,防止探測器被灰塵污染,影響報(bào)警、不敏捷等問題浮現(xiàn)。4、給排水工程施工現(xiàn)場配合a、室內(nèi)給水管道安裝不也許與土建主體構(gòu)造工程施工同步進(jìn)行,因而在管道安裝前要配合土建進(jìn)行預(yù)留孔洞和預(yù)埋件施工。5、安裝各工種之間配合a、管道與電氣、弱電安裝配合:各工種規(guī)定是先給排水及消防管道安裝后電氣弱電,管道盡量早安裝,以便給其他工種創(chuàng)造施工條件。油漆施工配合:施工中各種管道,支架在安裝前按設(shè)計(jì)規(guī)定作防腐。隔熱保溫施工:按施工作業(yè)分段、分系統(tǒng),管道安裝后及時(shí)試壓合格,交保溫施工。b、設(shè)備安裝與管道、電氣配合:設(shè)備到貨后盡快就位(含泵、風(fēng)機(jī)等),為管道配管與電氣接線創(chuàng)造條件。c、設(shè)備試運(yùn)轉(zhuǎn):設(shè)備試運(yùn)轉(zhuǎn)應(yīng)由電工先將電機(jī)單試合格,設(shè)備試運(yùn)轉(zhuǎn)時(shí)以鉗工為主,管工、電工配合,聯(lián)合試運(yùn)轉(zhuǎn),構(gòu)成有各工種參加調(diào)試小組,統(tǒng)一安排試運(yùn)轉(zhuǎn)工作。6、施工、技術(shù)及資料管理與土建配合做好預(yù)留預(yù)埋工作,預(yù)留人員進(jìn)行預(yù)留預(yù)埋,預(yù)留中不得隨意操作建筑鋼筋與土建構(gòu)造有矛盾處,由施工員與土建協(xié)商解決,在樓地坪內(nèi)錯(cuò)、漏、堵塞或設(shè)計(jì)增長埋管,必要在做樓地墻層前補(bǔ)埋;暗設(shè)箱盒、電管安裝應(yīng)隨土建墻體施工進(jìn)行;開關(guān)插座盒安裝應(yīng)作到位置精確,若預(yù)埋位置挪動(dòng)應(yīng)及時(shí)解決,待粉刷(或裝飾)后再裝箱蓋及面板;應(yīng)做好成品保護(hù)配合工作,不得隨旨在構(gòu)造上開槽、洞,特別應(yīng)注意對墻面、吊頂保護(hù),避免污染;土建施工人員不得隨意扳動(dòng)已安裝好管道、線路、開關(guān)等,不得隨意取走預(yù)埋管道管堵;在裝飾吊頂、裝飾墻面施工應(yīng)與裝飾工作配合進(jìn)行;應(yīng)與建設(shè)單位做好各方面配合工作,甲方供應(yīng)設(shè)備,由甲方按進(jìn)度籌劃及時(shí)提供,其到貨籌劃依照總體進(jìn)度規(guī)定,由項(xiàng)目班子提出;圖紙資料及設(shè)計(jì)變更,由甲方按規(guī)定數(shù)量及時(shí)供應(yīng),安裝與設(shè)計(jì)關(guān)于事宜并由甲方協(xié)調(diào),甲方監(jiān)理在施工過程中對安裝質(zhì)量進(jìn)行監(jiān)督,設(shè)備開箱檢查、試壓請甲方監(jiān)理人員參加和驗(yàn)收;甲方按進(jìn)度及時(shí)解決工程進(jìn)度款及設(shè)備訂貨款。第四章、施工進(jìn)度籌劃水電安裝施工總體控制籌劃,在土建施工組織總設(shè)計(jì)指引下,結(jié)合土建主體施工配合規(guī)定等詳細(xì)狀況進(jìn)行綜合安排,編制其安裝進(jìn)度籌劃,其籌劃實(shí)行應(yīng)抓好如下幾項(xiàng)工作:1、項(xiàng)目班子應(yīng)在土建、安裝總體進(jìn)度籌劃指引下,由施工員編制月、旬施工作業(yè)籌劃,并向班組人員交底,使班組人員明確工作目的。2、項(xiàng)目班子主管應(yīng)準(zhǔn)時(shí)參加土建現(xiàn)場協(xié)調(diào)會,以及公司召開各種關(guān)于會議,以協(xié)調(diào)該工程與公司各部門及各單位關(guān)于技術(shù)、質(zhì)量、供應(yīng)等關(guān)于事宜,以保證總體進(jìn)度實(shí)行。第五章、施工程序及施工要點(diǎn)一、總體規(guī)定1、組織專業(yè)技術(shù)人員理解設(shè)計(jì)意圖,參加施工圖技術(shù)交底,會審安裝圖與建筑構(gòu)造圖,尺寸與否對的,預(yù)留洞預(yù)埋與否吻合。2、熟悉關(guān)于工程驗(yàn)收規(guī)范,各種安裝工程圖集,質(zhì)量原則以及土建所編制綜合進(jìn)度籌劃,作好預(yù)留預(yù)埋工作。二、施工程序及施工要點(diǎn):(一)電氣工程安裝1、電氣工程總體規(guī)定a、應(yīng)按規(guī)定施工及驗(yàn)收規(guī)范,質(zhì)量評估原則以及原則圖集施工。b、照明系統(tǒng):按土建施工順序由下而上施工,做好暗設(shè)于樓地面及墻柱內(nèi)穿線管,接線盒等預(yù)埋工作。c、動(dòng)力系統(tǒng):暗敷鋼管隨照明系統(tǒng)同步敷設(shè),待設(shè)備就位后穿線并連接設(shè)備,作好試運(yùn)轉(zhuǎn)準(zhǔn)備。d、接地系統(tǒng):在土建綁扎好基本梁鋼筋后將基本梁上下兩層兩根主筋通長焊接作為接地母線。e、消防自動(dòng)報(bào)警及消防聯(lián)動(dòng)系統(tǒng):暗設(shè)于樓地面及墻體內(nèi)穿線管,盒箱等,配合土建主體施工而進(jìn)行。2、鋼管敷設(shè)技術(shù)辦法a、材料規(guī)定1)本工程電氣導(dǎo)管采用焊接鋼管,管材應(yīng)符合國家現(xiàn)行技術(shù)原則規(guī)定,應(yīng)有合格證及質(zhì)量鑒定等技術(shù)文獻(xiàn)。2)材料及配件規(guī)格型號應(yīng)符合設(shè)計(jì)規(guī)定,接線盒、開關(guān)盒等規(guī)格應(yīng)與面板、蓋板相配套。b、工藝流程彎管、箱、盒預(yù)制→測位→箱、盒定向穩(wěn)裝→管路敷設(shè)→管路連接→焊接接地→管路固定c、質(zhì)量原則1)鋼管連接辦法:采用套管焊接。2)現(xiàn)澆砼樓板上配管,應(yīng)在底層鋼筋綁扎完后,上層鋼筋未綁扎邁進(jìn)行;墻板配管應(yīng)在鋼筋綁扎后,模板架設(shè)之邁進(jìn)行。3)暗配管路宜沿近來路線敷設(shè),并應(yīng)減少彎曲;埋地管路不適當(dāng)穿過設(shè)備基本,若要穿過建筑物基本時(shí)應(yīng)加保護(hù)管保護(hù),埋入墻體或混凝土內(nèi)導(dǎo)管,與墻體或混凝土表面凈距不應(yīng)不大于15mm,暗配管管口出地坪不應(yīng)低于200mm。暗配管應(yīng)盡量減省交叉,如有交叉時(shí)大口徑放在小口徑下面,成排暗配管間距間隙應(yīng)不不大于或等于25mm。4)管子彎曲,管路彎曲處不應(yīng)有折皺,凹坑亢等缺陷,彎扁限度不應(yīng)不不大于管外徑10%,配管接頭不適當(dāng)設(shè)在彎曲處,埋地管宜把彎曲某些表露在地面。暗配管彎曲半徑不應(yīng)不大于管外徑6倍,埋設(shè)在地下或混凝土樓板內(nèi)時(shí)不應(yīng)不大于管外徑10倍。5)箱盒安裝為便于穿線,對于管路長度每超過45米無彎曲時(shí);管路長度超過30米,有一種彎曲時(shí);管路長度每超過20米有2個(gè)彎曲時(shí);管路長度每超過12米有3個(gè)彎曲時(shí),均應(yīng)在中間安裝接線盒,在盒箱上開孔應(yīng)采用機(jī)械辦法,不準(zhǔn)采用氣割電焊開孔。固定期應(yīng)采用有效防堵辦法,防止水泥漿浸入。6)在施工過程中,配管后及時(shí)加管堵把管口堵嚴(yán)實(shí),發(fā)現(xiàn)堵塞及時(shí)清理排除。3、電纜敷設(shè)技術(shù)辦法a、材料規(guī)定1)電纜型號、規(guī)格及電壓級別應(yīng)符合設(shè)計(jì)規(guī)定和國家現(xiàn)行技術(shù)原則規(guī)定。并應(yīng)產(chǎn)品合格證件和有關(guān)檢測記錄。2)電纜盤上應(yīng)標(biāo)明電纜型號、規(guī)格、電壓級別、長度及出廠日期。并與產(chǎn)品合格數(shù)據(jù)相符。電纜盤應(yīng)完好無損。3)電纜外觀質(zhì)量規(guī)定是:電纜未受機(jī)械外力損傷,鎧裝無銹蝕,纜線順直無皺和扭曲現(xiàn)象。4)電纜終端頭及所需絕緣材料必要符合電壓級別和設(shè)計(jì)規(guī)定。5)電纜絕緣膠和環(huán)氧樹脂膠必要采用定型產(chǎn)品,應(yīng)有理化及電氣性能實(shí)驗(yàn)報(bào)告和產(chǎn)品合格證。b、工藝流程1)電纜敷設(shè)沿橋架敷設(shè)電纜橋架應(yīng)安裝牢固,橫平豎直。其橋架構(gòu)造形式、固定方式應(yīng)符合設(shè)計(jì)規(guī)定。支架、橋架必要按設(shè)計(jì)規(guī)定,做好全程接地解決。4、管內(nèi)穿線技術(shù)辦法a、材料規(guī)定絕緣導(dǎo)線型號、規(guī)格必要符合設(shè)計(jì)規(guī)定,應(yīng)有產(chǎn)品出廠合格證及質(zhì)量鑒定等技術(shù)文獻(xiàn)。b、工藝流程c、質(zhì)量原則1)導(dǎo)線在管子內(nèi)無接頭,不進(jìn)入箱、盒垂直管子上口穿線后密封解決良好,導(dǎo)線連接牢固,包扎嚴(yán)密,絕緣良好,不傷線芯。2)選取導(dǎo)線要依照原則、相線、零線及保護(hù)接地線顏色應(yīng)加以區(qū)別,藍(lán)色線做零線,黃綠雙色做保護(hù)接地線,A相用黃色,B相用綠色,C相用紅色。導(dǎo)線在接線盒、開關(guān)盒、燈頭盒、插座盒等盒內(nèi)預(yù)留長度約為150mm,在配電箱內(nèi)預(yù)留長度為箱體周長1/2。3)同一交流回路導(dǎo)線必要穿入同一管內(nèi);不同回路,不同電壓,不得穿入同一管內(nèi)。4)箱、盒內(nèi)清潔無雜物,護(hù)口、護(hù)線套管齊全無脫落,導(dǎo)線排列整潔,并留有恰當(dāng)余量。5)導(dǎo)線連接:配線導(dǎo)線線芯連接,普通采用壓板壓接或套管連接。6)配線導(dǎo)線與設(shè)備、器具連接,應(yīng)符合下列規(guī)定:(1)導(dǎo)線截面為10mm2及如下單股銅(鋁)芯線可直接與設(shè)備、器具端子連接。(2)導(dǎo)線截面為2.5mm2及如下多股銅芯線線芯應(yīng)先擰緊搪錫或壓接線端子后再與設(shè)備、器具端子連接。(3)多股鋁芯線和截面不不大于2.5mm2多股銅芯線終端,除設(shè)備自帶插接式端子外,應(yīng)先焊接或壓接端子再與設(shè)備、器具端子連接。(4)套管連接器和壓模等應(yīng)與導(dǎo)線線芯規(guī)格匹配。壓接時(shí),壓接深度、壓口數(shù)量和壓接長度應(yīng)符合關(guān)于技術(shù)原則標(biāo)志著規(guī)定。(5)在配電配線分支線連接處,干線不應(yīng)受到支線橫向壓力。(6)照明電路絕緣電阻值不不大于0.5MΩ,動(dòng)力線路絕緣電阻值不不大于1MΩ。5、配電柜、箱(盤)安裝a、材料規(guī)定配電柜、箱(盤)應(yīng)為兩部定點(diǎn)廠家生產(chǎn),并有產(chǎn)品合格證及質(zhì)量鑒定等技術(shù)文獻(xiàn)。b、工藝流程c、質(zhì)量原則1)掛墻式配電箱安裝,箱體固定牢固,保證平直,標(biāo)高要統(tǒng)一,進(jìn)出線口位置精確,便于接線。2)配電箱(盤)應(yīng)位置對的,部件齊全,配電箱進(jìn)管孔應(yīng)為壓制孔,進(jìn)線管應(yīng)人規(guī)格恰當(dāng)孔中引進(jìn),并順直排列,一孔一管,進(jìn)箱長度應(yīng)帶好鎖緊螺母后剩2-4扣,帶牢護(hù)帽。禁止用氣焊和電焊割孔,使箱體因受力產(chǎn)生變形。3)配電箱內(nèi)導(dǎo)線連接牢固,綁扎成束,留有恰當(dāng)余量。中性線經(jīng)總線(N線端子)連接,不應(yīng)有絞接、死彎現(xiàn)象,包扎緊密,不傷線芯;油漆完整,盤內(nèi)外清潔,箱蓋、開關(guān)靈活,回路編號齊全,結(jié)線整潔,PE保護(hù)地線應(yīng)安裝明顯牢固,導(dǎo)線截面、顏色應(yīng)符合規(guī)范規(guī)定。4)盤、柜內(nèi)一次、二次回路均應(yīng)接對的,盤柜正面及背面各電器、端子排等應(yīng)標(biāo)明編號、名稱、用途及操作位置,牢固可靠,特別是一次回路接頭要全面檢查、緊固,線路要有規(guī)律順序排列,不得任意歪斜、交叉。6、照明器具安裝a、材料規(guī)定1)各種型號燈具。燈具型號、規(guī)格必要符合設(shè)計(jì)規(guī)定和國家現(xiàn)行技術(shù)原則規(guī)定。燈具配件齊全,無機(jī)械損傷、變形、涂膜剝落,燈罩破裂,燈箱歪翹等現(xiàn)象。并應(yīng)有產(chǎn)品質(zhì)量合格證。2)燈內(nèi)配線。燈內(nèi)配線應(yīng)符合設(shè)計(jì)規(guī)定及關(guān)于規(guī)定。3)專用燈具。(1)各種標(biāo)志燈批示方向?qū)Φ臒o誤。(2)應(yīng)急燈必要敏捷可靠。(3)事故燈具應(yīng)有特殊標(biāo)志。b、工藝流程c、質(zhì)量原則1)燈具安裝必要固定牢固可靠。2)固定燈具帶電部件絕緣材料,以及防止觸電保護(hù)絕緣材料,應(yīng)耐燃燒和防明火。3)燈具距地面高度不大于2.4m時(shí),燈具應(yīng)接(PE)保護(hù)地線,其導(dǎo)線為黃綠雙色導(dǎo)線,連接牢固可靠,并應(yīng)有標(biāo)記專用接地螺栓。4)燈頭接線,燈頭配件齊全,相線應(yīng)接在螺口燈頭中間端子上。5)建筑電氣照明裝置安裝應(yīng)達(dá)到正規(guī)、合理、牢固及齊全,保證使用功能。正規(guī)系指嚴(yán)格執(zhí)行建筑電氣照明裝置設(shè)計(jì)規(guī)定和關(guān)于技術(shù)原則、規(guī)范、規(guī)程等規(guī)定進(jìn)行安裝施工。合理系指選用照明器具必要合用、經(jīng)濟(jì)、可靠,安裝位置應(yīng)符合設(shè)計(jì)規(guī)定和實(shí)際需要,適于使用,便于操作。牢固系指電氣照明裝置安裝牢固、可靠,達(dá)到完全正常運(yùn)營,保證使用功能。整潔系指電氣照明裝置安裝同一環(huán)境條件下,安裝橫平豎直,品種、規(guī)格統(tǒng)一,安裝位置精確、端正、整潔統(tǒng)一,以達(dá)到顏色協(xié)調(diào)美觀、裝飾性強(qiáng)等。6)成排燈具安裝,其中心線偏差不應(yīng)不不大于5mm。7)吊鏈燈具燈線不應(yīng)受拉力,應(yīng)將燈線與吊鏈編叉在一起。8)通電試運(yùn)營。燈具安裝完畢,支線線路絕緣電阻測試合格后,方容許通電試運(yùn)營。通電后應(yīng)進(jìn)行巡視檢查,檢查內(nèi)容有燈具控制與否靈活、精確。開關(guān)與燈具控制順序相相應(yīng),如果在試運(yùn)營中浮現(xiàn)問題必要先斷電,然后查找因素進(jìn)行修復(fù)后再通電運(yùn)營,達(dá)到正常工作狀態(tài)進(jìn)行認(rèn)證。7、開關(guān)、插座安裝施工技術(shù)辦法a、材料規(guī)定1)各種開關(guān)、插座型號、規(guī)格,必要符合設(shè)計(jì)規(guī)定和國家現(xiàn)行技術(shù)原則規(guī)定。并應(yīng)有產(chǎn)品質(zhì)量合格證。外觀質(zhì)量應(yīng)完好無損,不得有裂紋和機(jī)械損傷。2)塑料臺板。應(yīng)具備足夠強(qiáng)度,臺板應(yīng)平整、無彎翹變形等現(xiàn)象。其規(guī)格型號必要符合設(shè)計(jì)規(guī)定。3)輔助材料。附屬配件其中金屬鐵件(膨脹螺栓、木螺絲、機(jī)螺栓等)均應(yīng)是鍍鋅原則件。其規(guī)格、型號應(yīng)符合設(shè)計(jì)規(guī)定。與組合件必要匹配。b、工藝流程c、質(zhì)量原則1)單相雙孔插座接線,應(yīng)依照插座類別和安裝方式而擬定接線辦法。(1)橫向安裝時(shí),面對插座右極接線柱應(yīng)接相線,左極接線柱應(yīng)接中性線。(2)豎向安裝時(shí),面對插座上極接線柱應(yīng)接相線,下極接線柱應(yīng)接中性線。2)單相三孔插座安裝時(shí),應(yīng)符合如下規(guī)定:(1)單相三孔插座安裝時(shí),面對插座上孔接線柱應(yīng)接保護(hù)地線,面對插座左極接線柱應(yīng)接相線,左極接線柱應(yīng)接中性線。(2)下孔極和左右兩極接線柱分別接相線。(3)接地或接零線在插座處不得串聯(lián)連接。3)插座標(biāo)高容許偏差值應(yīng)符合如下規(guī)定:(1)同一室內(nèi)安裝插座高度差不適當(dāng)不不大于5mm。(2)并列安裝相似型號插座高度差不適當(dāng)不不大于1mm。4)照明開關(guān)安裝,應(yīng)符合下列規(guī)定:(1)燈開關(guān)位置應(yīng)便于操作,安裝位置必要符合設(shè)計(jì)規(guī)定和規(guī)范規(guī)定。(2)安裝在同一室內(nèi)開關(guān),宜采用同一系列產(chǎn)品,開關(guān)通斷位置應(yīng)一致,且操作靈活、接觸可靠。(3)開關(guān)安裝位置規(guī)定是:開關(guān)邊沿距門框距離宜為150~200mm,距地面高度如設(shè)計(jì)無規(guī)定期宜為1300mm。(4)開關(guān)安裝容許偏差值規(guī)定是:并列安裝相似型號開關(guān)距地面高度應(yīng)一致,高度差不應(yīng)不不大于1mm。同一室內(nèi)安裝開關(guān)高度差不應(yīng)不不大于5mm。5)開關(guān)接線應(yīng)符合如下規(guī)定:(1)相線應(yīng)經(jīng)開關(guān)控制。接線時(shí)應(yīng)仔細(xì)辨認(rèn),辨認(rèn)導(dǎo)線相線與零線,嚴(yán)格做到開關(guān)控制(即分?jǐn)嗷蚪油?電源相線,應(yīng)使開關(guān)斷開后燈具上不帶電。(2)扳把開關(guān)普通為兩個(gè)靜觸點(diǎn),分別由兩個(gè)接線柱連接;連接時(shí)除應(yīng)把相線接到開關(guān)上外,并應(yīng)接成扳把向上為開燈,扳把向下為關(guān)燈。接線時(shí)不可接反,否則維修燈具時(shí),易導(dǎo)致意外觸電或短路事故。(3)雙聯(lián)及以上暗扳把開關(guān),每一聯(lián)即為一只單獨(dú)開關(guān),能分別控制一盞電燈。接線時(shí),應(yīng)將相線連接好,分別接到開關(guān)上與動(dòng)觸點(diǎn)連通接線柱上,而將開關(guān)線接到開關(guān)靜觸點(diǎn)接線柱上。(4)暗裝開關(guān)應(yīng)采用專用盒,專用盒四周不應(yīng)有空隙,蓋板應(yīng)端正,并應(yīng)緊貼飾面。(二)、給排水及消防水系統(tǒng)工程安裝1、管道安裝總體規(guī)定a、由于管道系統(tǒng)較多,因而必要參見關(guān)于專業(yè)設(shè)備圖和裝修建筑圖,核對各種管道坐標(biāo)、標(biāo)高與否有交叉,管道排列所用空間與否合理,核算精確后方可施工。b、設(shè)備配管:應(yīng)先設(shè)備定位,而后配管,為趕工期可先干支管面后設(shè)備本體配管。c、支、吊架制作安裝:管道支、吊架形式可依照現(xiàn)場狀況參照國標(biāo)S161、02SS405-2、96S406安裝制作,支、吊架必要穩(wěn)固、可靠、有足夠剛度,以避免系統(tǒng)運(yùn)營時(shí)也許帶來共振與噪聲,支架位置與緊固形式必要考慮系統(tǒng)調(diào)試與檢修以便,并避開法蘭、壓力表、測溫點(diǎn)、調(diào)節(jié)閥手輪等需經(jīng)常調(diào)節(jié)及檢修部件。d、試壓及沖洗:管道安裝完畢后對管道進(jìn)行全面檢查,合格后把不適當(dāng)和管道一起試壓配件拆除,換上暫時(shí)短管,所有封口進(jìn)行封閉,然后在管道最低處灌水,在最高處放氣,試壓時(shí)應(yīng)緩慢升高至實(shí)驗(yàn)壓力,壓降應(yīng)符合GB50242-規(guī)范規(guī)定或設(shè)計(jì)規(guī)定。班組質(zhì)檢員應(yīng)及時(shí)填記試壓記錄,對試壓合格管子應(yīng)進(jìn)行沖洗工作,沖洗工作應(yīng)符合設(shè)計(jì)及規(guī)范規(guī)定,用水沖洗時(shí),直到系統(tǒng)排水清潔為止。為了保證管道沖洗干凈,應(yīng)分段進(jìn)行沖洗,并將管道上安裝止回閥、儀表等暫時(shí)拆下保管,經(jīng)沖洗完后重新裝上。管道沖洗出口要設(shè)暫時(shí)管道和閥門,以控制壓力,并將排水管接至室外安全處,普通規(guī)定排出管截面和被沖洗管截面相似,做好沖洗記錄。e、保溫、油漆:管道刷漆應(yīng)均勻一致,油膜附著牢固無剝落、皺紋、氣泡、針孔等缺陷。管道除銹應(yīng)徹底,面漆一定要在防銹漆徹底干后再涂刷。經(jīng)防銹后管道須按設(shè)計(jì)規(guī)定進(jìn)行保溫,管殼應(yīng)與管道包緊,厚度一致,接口用鋁箔膠帶粘結(jié)。2、給水及消防管道安裝技術(shù)辦法a、材料規(guī)定1)生活給水管道所用材料必要達(dá)到飲用水原則。2)給水及消防管道材料、規(guī)格必要符合設(shè)計(jì)規(guī)定,管材及管件均應(yīng)有出廠合格證。3)閥門安裝前實(shí)驗(yàn):(1)實(shí)驗(yàn)數(shù)量eq\o\ac(○,1)安裝在主干管上起啟閉作用閥門應(yīng)逐個(gè)實(shí)驗(yàn)。eq\o\ac(○,2)安裝在其他部位閥門從每批(規(guī)格、型號、牌號均相似)數(shù)量中抽查10%且不少于1個(gè)。(2)實(shí)驗(yàn)規(guī)定eq\o\ac(○,1)閥門強(qiáng)度與嚴(yán)密性實(shí)驗(yàn)壓力:強(qiáng)度實(shí)驗(yàn)壓力為閥門公稱壓力1.5倍,嚴(yán)密性實(shí)驗(yàn)壓力為閥門公稱壓力1.1倍。eq\o\ac(○,2)閥門試壓持續(xù)時(shí)間應(yīng)不少于下表規(guī)定。閥門實(shí)驗(yàn)持續(xù)時(shí)間公稱直徑(mm)最短實(shí)驗(yàn)持續(xù)時(shí)間(s)嚴(yán)密性實(shí)驗(yàn)強(qiáng)度實(shí)驗(yàn)金屬密封非金屬密封≤5015151565~200301560250~4506030180(3)合格原則:在實(shí)驗(yàn)持續(xù)時(shí)間內(nèi),實(shí)驗(yàn)壓力應(yīng)保持不變,且殼體填料及閥瓣密封面無滲漏。b、工藝流程c、質(zhì)量規(guī)定1)管道螺紋加工精度應(yīng)符合國標(biāo)《管螺紋》規(guī)定,螺紋清潔規(guī)整,無斷絲或缺絲,連接牢固,管螺紋根部應(yīng)有外露螺紋兩至三絲,接口處無外露油麻,困工螺紋時(shí)應(yīng)使用無毒冷卻液冷卻加工部位,管端倒角毛刺用專用工具清除。2)卡箍連接管道加工溝槽時(shí)應(yīng)用專用滾槽機(jī)壓槽,壓槽過程應(yīng)持續(xù)漸進(jìn),并用原則測量器具測量溝槽全周深度,槽深過淺應(yīng)重新調(diào)節(jié)滾槽機(jī)壓槽深度壓槽直至溝槽深度符合規(guī)定為止。槽深過深應(yīng)將不合格某些鋸斷作廢。擰緊卡箍螺栓時(shí)應(yīng)采用十字?jǐn)Q緊法,緊固螺栓應(yīng)平行,同步勻稱旋固,防止膠圈在卡箍中起皺。3)凡有保溫以及暗敷設(shè)給水管道在隱蔽前必要做水壓實(shí)驗(yàn),實(shí)驗(yàn)合格后方可隱蔽。埋地敷設(shè)時(shí)必要符合設(shè)計(jì)及施工規(guī)范規(guī)定,隱蔽前要做好自檢記錄。4)給水管道不適當(dāng)穿過建筑物沉降縫、伸縮縫,必要穿越時(shí)應(yīng)采用必要技術(shù)辦法,如采用橡膠軟管法、絲口彎頭法、加鋼套管法等。穿越地下室外墻或地下構(gòu)筑物墻壁應(yīng)加防水套管。5)給水及消防水系統(tǒng)竣工后或交付使用前,必要進(jìn)行整體水壓實(shí)驗(yàn)及吹洗。6)室內(nèi)消火栓安裝質(zhì)量原則:(1)消火栓系統(tǒng)試射實(shí)驗(yàn)符合設(shè)計(jì)規(guī)定。(2)安裝消火栓水龍帶,水龍帶與水槍和迅速接頭綁扎好后,應(yīng)依照箱內(nèi)構(gòu)造將水龍帶掛在箱內(nèi)掛架、卷盤或支架上。(3)箱式消火栓安裝應(yīng)符合下列規(guī)定:eq\o\ac(○,1)栓口應(yīng)朝外或朝下,并不應(yīng)安裝在門軸側(cè);eq\o\ac(○,2)栓口中心距地面為1.1m,容許偏差為±20mm;eq\o\ac(○,3)閥門中心距側(cè)面為140mm,距箱后內(nèi)表面為100mm,容許偏差為5mm;eq\o\ac(○,4)消火栓箱體安裝垂直度容許偏差為3mm。3、排水管道安裝技術(shù)辦法a、材料規(guī)定管材、管件等材料應(yīng)是有質(zhì)量檢查部門產(chǎn)品合格證,并應(yīng)有明顯標(biāo)志標(biāo)明生產(chǎn)廠名稱和規(guī)格。包裝上應(yīng)標(biāo)有批號、數(shù)量、生產(chǎn)日期和檢查代號。b、工藝流程廢水干管安裝→廢水立管安裝c、質(zhì)量控制依照施工圖位置,預(yù)留套管。管道焊接連接,焊縫飽滿、無夾渣。支、吊架制作安裝:管道支、吊架形式可依照現(xiàn)場狀況參照國標(biāo)S161、02SS405-2、96S406安裝制作,支、吊架必要穩(wěn)固、可靠、有足夠剛度。油漆:管道刷漆應(yīng)均勻一致,油膜附著牢固無剝落、皺紋、氣泡、針孔等缺陷。管道除銹應(yīng)徹底,面漆一定要在防銹漆徹底干后再涂刷。(三)采暖系統(tǒng)安裝1、采暖系統(tǒng)安裝a、管材及配件本工程管材采用無縫鋼管1)管材、管件應(yīng)標(biāo)明生產(chǎn)廠名稱、重要技術(shù)特性和規(guī)格,包裝上應(yīng)有批號、數(shù)量、生產(chǎn)日期和檢查代號。2)管材應(yīng)符合國際原則。3)管材內(nèi)外表面應(yīng)光滑、清潔,不容許浮現(xiàn)分層、針孔、裂紋、氣泡、痕紋和夾雜。b、安裝前應(yīng)進(jìn)行施工技術(shù)交底。1)按設(shè)計(jì)圖紙規(guī)定,分清高低區(qū)回路安裝位置,管徑、變徑、預(yù)留口、坡向,卡架位置等施工草圖,涉及起點(diǎn)、末端和拐彎、節(jié)點(diǎn)、預(yù)留口、坐標(biāo)位置等。2)伸縮補(bǔ)償器安裝位置必要符合設(shè)計(jì)規(guī)定,并應(yīng)按關(guān)于規(guī)定進(jìn)行預(yù)拉伸。c、工藝流程:安裝準(zhǔn)備→預(yù)制加工→卡架安裝→干管安裝→試壓→沖洗→防腐→保溫→調(diào)試c、質(zhì)量控制:1)管道焊接:(1)管道焊接前要將兩管軸線對中,先將兩管端部點(diǎn)焊牢,管徑100mm如下者可以點(diǎn)焊三個(gè)點(diǎn)。(2)管道及管件焊接應(yīng)做到:焊縫高度不得低于母材表面,焊縫與母材應(yīng)圓滑過渡;焊縫及熱影響區(qū)表面應(yīng)無裂紋、未焊透、夾渣、弧坑和氣孔等缺陷。2)凡有保溫以及暗敷設(shè)采暖管道在隱蔽前必要做水壓實(shí)驗(yàn),實(shí)驗(yàn)合格后方可隱蔽。埋地敷設(shè)時(shí)必要符合設(shè)計(jì)及施工規(guī)范規(guī)定,隱蔽前要做好自檢記錄。3)采暖系統(tǒng)竣工后或交付使用前,必要進(jìn)行整體水壓實(shí)驗(yàn)及系統(tǒng)調(diào)試。2、采暖系統(tǒng)實(shí)驗(yàn)與調(diào)節(jié)a、采暖系統(tǒng)水壓實(shí)驗(yàn)在采暖系統(tǒng)安裝完、管道保溫前,應(yīng)進(jìn)行水壓實(shí)驗(yàn)。實(shí)驗(yàn)壓力應(yīng)按設(shè)計(jì)規(guī)定進(jìn)行。1)實(shí)驗(yàn)時(shí)間及規(guī)定:(1)采暖系統(tǒng)在實(shí)驗(yàn)壓力下10min內(nèi)壓力降不不不大于0.02MPa,降至工作壓力后檢查,不滲不漏。b、采暖系統(tǒng)沖洗1)系統(tǒng)試壓合格后,應(yīng)用清水進(jìn)行沖洗。2)沖洗水流速以不不大于1.5m/s速度進(jìn)行。3)管道沖洗無特殊規(guī)定期,以排出口水質(zhì)不含泥沙、鐵屑等雜質(zhì),且水色透明不渾濁為合格。4)系統(tǒng)沖洗合格后,應(yīng)對系統(tǒng)內(nèi)過濾器和除污器進(jìn)行清掃。(四)通風(fēng)工程安裝1、通風(fēng)系統(tǒng)安裝總體規(guī)定a、由于安裝工程各系統(tǒng)管線比較多,因而必要參見關(guān)于專業(yè)設(shè)備圖和裝修建筑圖,核對各種管道坐標(biāo)、標(biāo)高與否有交叉,管道排列所用空間與否合理,核算精確后方可施工。b、在風(fēng)管穿越剪力墻處要配合土建做好套管預(yù)埋工作。c、在風(fēng)管穿越有防火規(guī)定區(qū)域時(shí),必要嚴(yán)格按照設(shè)計(jì)規(guī)定或現(xiàn)行施工質(zhì)量驗(yàn)收規(guī)范規(guī)定做好防火辦法。d、系統(tǒng)檢查:風(fēng)管安裝完畢后對管道進(jìn)行全面檢查,進(jìn)行漏光或漏風(fēng)量檢查。檢查成果應(yīng)符合通風(fēng)空調(diào)工程施工質(zhì)量驗(yàn)收規(guī)范GB50243-規(guī)定或設(shè)計(jì)規(guī)定。班組質(zhì)檢員應(yīng)及時(shí)填寫檢查記錄。2、風(fēng)管制作a、材料規(guī)定所使用板材、型鋼重要材料應(yīng)具備出廠合格證明書或質(zhì)量鑒定文獻(xiàn)。制作風(fēng)管及配件鋼板厚度應(yīng)符合設(shè)計(jì)規(guī)定或GB50243-關(guān)于規(guī)定。排煙系統(tǒng)鋼板厚度可參照高壓系統(tǒng)。鍍鋅薄鋼板表面不得有裂紋、結(jié)疤及水印等缺陷,應(yīng)有鍍鋅層結(jié)晶花紋。b、質(zhì)量規(guī)定1)風(fēng)管規(guī)格、尺寸必要符合設(shè)計(jì)規(guī)定。2)風(fēng)管咬縫必要緊密、寬度均勻、無孔洞半咬口和脹裂等缺陷。直管縱向咬縫應(yīng)錯(cuò)開。3)風(fēng)管外觀質(zhì)量應(yīng)達(dá)到折角平直,圓弧均勻,兩端面平行,無翹角。表面凹凸不不不大于5mm;風(fēng)管與法蘭連接牢固,翻邊平整,寬度不不不大于6mm,緊貼法蘭。4)風(fēng)管法蘭孔距應(yīng)符合設(shè)計(jì)規(guī)定和施工規(guī)范規(guī)定,焊接應(yīng)牢固,焊縫處不設(shè)立螺孔。螺孔具備互換性。5)風(fēng)管加固應(yīng)牢固可靠、整潔,間距適當(dāng),均勻?qū)ΨQ。3、風(fēng)管及部件安裝a、材料規(guī)定1)各種安裝材料產(chǎn)品應(yīng)具備出廠合格證明書或質(zhì)量鑒定文獻(xiàn)及產(chǎn)品清單。2)風(fēng)管成品不許有變形、扭曲、開裂、孔洞,法蘭脫落。法蘭開焊、漏鉚、漏打螺栓眼等缺陷。3)安裝閥體、消聲器、罩體、風(fēng)口等部件應(yīng)檢查調(diào)節(jié)裝置與否靈活,消聲片,油漆層有無損傷。4)安裝使用材料有:螺栓、螺母、墊圈、墊料、自攻螺絲、鉚釘、拉鉚釘、電焊條、氣焊條、焊絲、不銹鋼焊絲、石棉布、帆布、膨脹螺栓等,都應(yīng)符合產(chǎn)品質(zhì)量規(guī)定。b、重要機(jī)具手錘、電錘、手電鉆、手鋸、電動(dòng)雙刃剪、電動(dòng)砂輪鋸、角向砂輪鋸、臺鉆、電氣焊具、扳手、改錐、木錘、拍板、手剪、倒鏈、高凳、滑輪繩索、尖沖、鏨子、射釘槍、刷子、安全帽、安全帶等。c、工藝流程擬定標(biāo)高→制作吊架→設(shè)立吊點(diǎn)→安裝吊架預(yù)檢→風(fēng)管→法蘭連接(墊料穿螺絲)風(fēng)管排列→安裝就位找平找正→檢查→評估d、質(zhì)量控制1)風(fēng)管支、吊架制作應(yīng)注意問題:(1)支架懸臂、吊架吊鐵采用角鋼或槽鋼制成;斜撐材料為角鋼;吊桿采用圓鋼;扁鐵用來制作抱箍。(2)吊桿圓鋼應(yīng)依照風(fēng)管安裝標(biāo)高恰當(dāng)截取。套絲不適當(dāng)過長,絲扣末端不應(yīng)超過托盤最低點(diǎn)。(3)風(fēng)管支、吊架制作完畢后,應(yīng)進(jìn)行除銹,刷一遍防銹漆。2)支、吊架安裝應(yīng)注意問題:(1)風(fēng)管安裝,管路較長時(shí),應(yīng)在恰當(dāng)位置增設(shè)吊架防止擺動(dòng)。(2)支、吊架標(biāo)高必要對的,如圓形風(fēng)管管徑由大變小,為保證風(fēng)管中心線水平,支架型鋼上表面標(biāo)高,應(yīng)作相應(yīng)提高。對于有坡度規(guī)定風(fēng)管,托架標(biāo)高也應(yīng)按風(fēng)管坡度規(guī)定安裝。(3)支、吊架預(yù)埋件或膨脹螺栓埋入某些不得油漆,并應(yīng)除去油污。(4)支、吊架不得安裝在風(fēng)口、閥門,檢查孔等處,以免妨礙操作。吊架不得直接吊在法蘭上。3)墊法蘭墊料應(yīng)注意問題:(1)理解各種墊料使用范疇,避免用錯(cuò)墊料。(2)擦拭掉法蘭表面異物和積水。(3)法蘭墊料不能擠入或凸入管內(nèi),否則會增大流動(dòng)阻力,增長管內(nèi)積塵。4)部件安裝:(1)風(fēng)管各類調(diào)節(jié)裝置應(yīng)安裝在便于操作部位。(2)防火閥安裝,方向位置應(yīng)對的,易熔件應(yīng)迎氣流方向。排煙閥手動(dòng)裝置(預(yù)埋導(dǎo)管)不得浮現(xiàn)死彎及癟管現(xiàn)象。(3)止回閥宜安裝在風(fēng)機(jī)壓出端,啟動(dòng)方向必要與氣流方向一致。(4)變風(fēng)量末端裝置安裝,應(yīng)設(shè)獨(dú)立支吊架,與風(fēng)管接前應(yīng)做動(dòng)作實(shí)驗(yàn)。(5)手動(dòng)密閉閥安裝時(shí)閥門上標(biāo)志箭頭方向應(yīng)與受沖擊波方向一致。5)風(fēng)管及部件安裝必要牢固,位置、標(biāo)高和走向符合設(shè)計(jì)規(guī)定,部件方向?qū)Φ模僮饕员?。防火閥檢查孔位置必要設(shè)在便于操作部位。6)支、吊、托架形式、規(guī)格、位置、間距及固定必要符合設(shè)計(jì)規(guī)定和施工規(guī)范規(guī)定,禁止設(shè)在風(fēng)口、閥門及檢視門處。7)斜插板閥垂直安裝時(shí),閥板必要向上拉啟;水平安裝時(shí),閥板順氣流方向插入,閥板不應(yīng)向下拉啟。8)風(fēng)管法蘭連接對接平行,嚴(yán)密,螺栓緊固。螺栓露出長度適當(dāng)一致,同一管段法蘭螺母在同一側(cè)。10)風(fēng)口安裝位置對的,外露某些平整美觀,同一房間內(nèi)標(biāo)高一致,排列整潔。11)柔性短管松緊適當(dāng),長度符合設(shè)計(jì)規(guī)定和施工規(guī)范規(guī)定,無開裂和扭曲現(xiàn)象。(五)節(jié)能工程執(zhí)行建筑節(jié)能原則,加強(qiáng)建筑物用能設(shè)備運(yùn)營管理,合理設(shè)計(jì)建筑維護(hù)構(gòu)造熱工性能,提高智能、照明、給排水系統(tǒng)運(yùn)營效率,以及運(yùn)用可在生資源,在保證建筑物使用功能和室內(nèi)熱環(huán)境質(zhì)量前提下,能提高能源運(yùn)用效率,減少建筑物使用能耗,合理、有效地運(yùn)用能源活動(dòng)。在實(shí)行建筑節(jié)能施工驗(yàn)收規(guī)范中,要嚴(yán)格執(zhí)行20個(gè)強(qiáng)制性條文,其中建筑設(shè)備調(diào)試和檢測,是建筑節(jié)能驗(yàn)收重點(diǎn)。并按規(guī)范規(guī)定,某些進(jìn)場材料及設(shè)備進(jìn)行復(fù)驗(yàn),見證取樣送檢。配電與照明工程安裝完畢后,應(yīng)進(jìn)行系統(tǒng)節(jié)能性能檢測,并由檢測資質(zhì)檢測機(jī)構(gòu)檢測,出具報(bào)告。低壓配電系統(tǒng)選取電纜、電線截面不得低于設(shè)計(jì)值,進(jìn)場時(shí)應(yīng)對其截面和每芯異體電阻值進(jìn)行見證取樣送檢,每芯導(dǎo)體電阻值應(yīng)符合規(guī)范規(guī)定規(guī)定第六章、工程技術(shù)、質(zhì)量、安全辦法一、工程技術(shù)管理1、組織人員認(rèn)真編制施工組織設(shè)計(jì)2、技術(shù)交底:加強(qiáng)對施工工藝質(zhì)量控制,逐級做好技術(shù)交底,使全體人員熟悉工程狀況和重要特點(diǎn),設(shè)計(jì)意圖、規(guī)定、質(zhì)量原則及施工操作過程,施工人員應(yīng)認(rèn)真按技術(shù)交底規(guī)定作業(yè),使施工工藝質(zhì)量控制原則化、規(guī)范化、制度化。二、施工管理1、施工中按照設(shè)計(jì)圖紙、操作規(guī)程和關(guān)于技術(shù)規(guī)范進(jìn)行,遵守施工程序,嚴(yán)格遵守崗位責(zé)任制并在按工序搞好自檢、隱蔽驗(yàn)收檢查、交接檢查基本上搞好質(zhì)量安全工作,解決施工質(zhì)量技術(shù)問題,保證工程質(zhì)量符合國家驗(yàn)收規(guī)范和設(shè)計(jì)規(guī)定,滿足業(yè)主需要。2、工程更改:a、在施工過程中由于設(shè)計(jì)圖紙變更工藝變化,施工條件變化或增長預(yù)算等各種因素,必要更改設(shè)計(jì)時(shí),必要經(jīng)業(yè)主、施工單位協(xié)商一致,由設(shè)計(jì)單位出具工程變更告知書(設(shè)計(jì)聯(lián)系書),必要時(shí)應(yīng)附圖闡明。3、隱蔽工程驗(yàn)收:a、凡隱蔽工程驗(yàn)收如平頂內(nèi)管道、電纜、電管、保溫及埋于樓板、墻體內(nèi)管道等都必要隱蔽前組織驗(yàn)收。b、隱蔽工程驗(yàn)收單,由施工項(xiàng)目部會同業(yè)主或監(jiān)理一起參加驗(yàn)收并進(jìn)行簽證。c、凡兩個(gè)工種施工隱蔽工程,應(yīng)辦理交接驗(yàn)罷手續(xù),上道工序不合格,下道工序不準(zhǔn)施工,由此產(chǎn)生責(zé)任由上道工序負(fù)責(zé)。4、檢查復(fù)核:a、各種架空管標(biāo)高和坡度復(fù)查。b、加強(qiáng)對材料、設(shè)備和半成品進(jìn)行質(zhì)量控制,采用相應(yīng)技術(shù)管理辦法,使這些因素被控制在容許范疇內(nèi)。嚴(yán)格按質(zhì)量原則訂貨、采購、包裝和運(yùn)送,所有物資進(jìn)場均需按原則嚴(yán)格檢查和驗(yàn)收,工程用各種材質(zhì)等均應(yīng)有質(zhì)保書和合格證,進(jìn)場后按規(guī)定進(jìn)行存儲、保管和加工,并按進(jìn)度籌劃時(shí)間提供施工需要。5、工序控制:突出抓好施工工序控制,以及明確各個(gè)工序控制點(diǎn)應(yīng)當(dāng)達(dá)到質(zhì)量目的,按規(guī)定對工序控制點(diǎn)質(zhì)量進(jìn)行檢測,并找出質(zhì)量差距,防止發(fā)生質(zhì)量問題,不讓上道工序不合格產(chǎn)品轉(zhuǎn)入下道工序。6、工程質(zhì)量檢查與驗(yàn)收:按規(guī)定搞好分某些項(xiàng)工程檢查與驗(yàn)收,以及單位工程質(zhì)量檢查與評估。a、由班組進(jìn)行尋常自檢和互檢,發(fā)現(xiàn)問題及時(shí)解決。b、由施工技術(shù)負(fù)責(zé)人組織工序交接檢查和多班組作業(yè)交接檢查,發(fā)現(xiàn)問題即分清責(zé)任,隨時(shí)解決,做好分項(xiàng)工程檢查工作。c、由質(zhì)檢員進(jìn)行檢查,特別注重核心部位和薄弱環(huán)節(jié)檢查,協(xié)同施工技術(shù)人員和班組解決存在問題,做好分項(xiàng)工程核定工作。三、技術(shù)辦法1、認(rèn)真做好施工前準(zhǔn)備工作,組織關(guān)于人員熟悉關(guān)于圖紙資料,及關(guān)于技術(shù)要領(lǐng),認(rèn)真做好對施工班組技術(shù)交底工作,使所有施工人員在施工前就明確各項(xiàng)技術(shù)要領(lǐng)、質(zhì)量、安全規(guī)定。2、組織特殊工種上崗前培訓(xùn),持證上崗作為本工程一項(xiàng)制度,同步在實(shí)地操作前還進(jìn)行試作業(yè),待完全符合關(guān)于方面規(guī)定后,方可正式上崗作業(yè)。3、工程上使用材料都應(yīng)具備合格證、質(zhì)保書、部件、零件除有上述書面資料外,必要逐個(gè)檢查,不得有砂眼、裂紋及嚴(yán)重銹蝕現(xiàn)象,禁止將有缺陷產(chǎn)品用于工程。4、嚴(yán)格按照圖紙?jiān)瓌t闡明,對的地使用所有材料和配件,不得任意代用材料和配件,特別是減少級別代用,在安裝調(diào)節(jié)用安全控制配件時(shí),一定要一絲不茍逐個(gè)核對,精確無誤地使用每個(gè)配件,特別是帶有方向性配件,一定要依照管路、介質(zhì)、流向?qū)Φ氖褂谩?、材料管理方面,在購買、運(yùn)送、存儲、派有專人負(fù)責(zé),在倉庫內(nèi)存儲整潔,各種材料都標(biāo)有顯而易見標(biāo)記,專人負(fù)責(zé),禁止任意領(lǐng)用,堆放在室外管材要搭雨棚。6、施工班組在安裝前必要按照各種不同規(guī)定,認(rèn)真地對管道內(nèi)及零件、閥件進(jìn)行認(rèn)真清理和清洗,詳細(xì)如下:鋼管有清洗規(guī)定期,應(yīng)嚴(yán)格按照規(guī)定進(jìn)行,保證清洗后符合規(guī)定,沒有清洗規(guī)定,用布球在內(nèi)壁來回清刷多次,再用壓縮氣體吹凈,保證管內(nèi)沒有臟物。7、管道切割,采用機(jī)器或砂輪切割機(jī)切割。所有切割完畢后管道內(nèi)壁,必要清理達(dá)到規(guī)定規(guī)定。8、閥門等配件安裝位置、型號、方向應(yīng)對的,操作手輪方向以向上和操作檢修以便為原則,特別是升降式單向閥,一定要安裝在水平管道上。9、有坡度設(shè)計(jì)規(guī)定管道,必要嚴(yán)格按規(guī)定設(shè)立坡度,坡向應(yīng)對的,對的設(shè)立排放點(diǎn)。10、為貫徹預(yù)留預(yù)埋工作,保證預(yù)留預(yù)埋質(zhì)量,必要弄清建筑軸線和標(biāo)高,由專業(yè)施工員核對預(yù)留預(yù)埋圖,以保證作到預(yù)留預(yù)埋不漏不錯(cuò),同步作好預(yù)埋件加工準(zhǔn)備和預(yù)留預(yù)埋技術(shù)交底及質(zhì)量、進(jìn)度檢查;并及時(shí)在預(yù)埋安裝后對接地電阻進(jìn)行測試,接地電阻不不大于設(shè)計(jì)規(guī)定1Ω時(shí),即時(shí)補(bǔ)加輔助接地裝置,以保建筑物安全。四、質(zhì)量保證辦法1、層層貫徹質(zhì)量責(zé)任制,建立項(xiàng)目工程質(zhì)量保證體系。2、施工員按本組設(shè)計(jì)及施工圖紙規(guī)范規(guī)定和工程詳細(xì)狀況,編制分項(xiàng)分部施工方案,向班組作業(yè)人員進(jìn)行方案交底。3、嚴(yán)格按圖紙施工,嚴(yán)守操作規(guī)程,未經(jīng)設(shè)計(jì)部門審核批準(zhǔn),不得擅自變更和修改設(shè)計(jì),禁止違章作業(yè)。4、與工程施工進(jìn)度同步,按陜西省《單位工程竣工技術(shù)資料目錄表》作好工程竣工資料。5、凡是隱蔽工程竣工,及時(shí)會同甲方、監(jiān)理人員檢查驗(yàn)收,并做好原始記錄。6、施工員按分項(xiàng)工程向班組作書面施工技術(shù)、質(zhì)量、安全技術(shù)交底,質(zhì)檢員對工序質(zhì)量實(shí)行監(jiān)督檢查。7、現(xiàn)場合有計(jì)量器具,必要是檢測有效期內(nèi)合格器具,安裝工程所設(shè)立儀表,安裝前應(yīng)送檢合格。8、現(xiàn)場施工人員必要虛心接受甲方及各級質(zhì)監(jiān)人員監(jiān)督,并及時(shí)整治質(zhì)量問題。五、質(zhì)量管理點(diǎn)管理辦法1、質(zhì)量管理點(diǎn)設(shè)立:項(xiàng)目部技術(shù)負(fù)責(zé)人與施工員對工程質(zhì)量目的重要項(xiàng)目、薄弱環(huán)節(jié)、核心部位、施工部位需控制重要質(zhì)量特性,對影響工期質(zhì)量、安全等重要因素環(huán)節(jié)、新工藝、新技術(shù)施工環(huán)節(jié)及易出質(zhì)量通病項(xiàng)目設(shè)備管理點(diǎn)。重要在開關(guān)盒、插座盒高度、插座中相、零、地線排列,開關(guān)離門框距離、金屬橋架敷設(shè)平直度、垂直度及接地跨接線連接,封閉式母線槽連接松緊度,敷設(shè)平直度及垂直度等。2、操作原則:一方面由項(xiàng)目技術(shù)負(fù)責(zé)人制定管理點(diǎn)工藝流程圖,編出過程號,然后按本施工組織設(shè)計(jì)“施工程序及要點(diǎn)”及所列規(guī)范,質(zhì)量原則制定詳細(xì)質(zhì)量管理點(diǎn)作業(yè)指引書,由專業(yè)施工員向班組作詳細(xì)技術(shù)交底。3、管理辦法:操作工人必要嚴(yán)格按質(zhì)量管理點(diǎn)技術(shù)交底進(jìn)行認(rèn)真操作,并多頻次進(jìn)行自檢互檢,如發(fā)現(xiàn)質(zhì)量不合格,應(yīng)與施工員一道認(rèn)真查找因素,制定整治辦法及防止辦法,并進(jìn)行認(rèn)真整治,直到合格為止。施工員和質(zhì)量員應(yīng)對質(zhì)量管理點(diǎn)進(jìn)行多頻次監(jiān)控,隨時(shí)抽查并保證100%合格率。并開展抽檢一次合格管理,和檢查前一次過程,保證本過程,服務(wù)下一種過程質(zhì)量活動(dòng),對質(zhì)量管理點(diǎn)全過程作詳細(xì)記錄,填寫好質(zhì)量管理點(diǎn)班組自檢表、質(zhì)量檢查登記表,質(zhì)量因素分析表及質(zhì)量管理點(diǎn)明細(xì)表。六、安全技術(shù)辦法我項(xiàng)目部提出“無重傷、無死亡、無重大設(shè)備事故、無火災(zāi)事故、無輕傷事故”在本工程施工全過程中必將得貫徹貫徹,項(xiàng)目經(jīng)理部將采用有效辦法在工程各個(gè)階段及施工各個(gè)環(huán)節(jié)中強(qiáng)化安全生管理,增強(qiáng)施工人員自我保護(hù)意識,做屆時(shí)時(shí)講安全,人人管安全。為此,本工程施工中將遵守如下安全規(guī)則:工程所有管理人員及工人都必要通過安全以及施工崗位培訓(xùn),熟悉本工程核心部位及普通部位安全與防火規(guī)定。特殊工種須經(jīng)關(guān)于部門考試并發(fā)相應(yīng)國家承認(rèn)操作證及上崗證,所有施工人員均須持證上崗。1、成立安全生產(chǎn)保證體系:建立項(xiàng)目經(jīng)理為組長,構(gòu)成現(xiàn)場專職安全員及各專業(yè)施工員,班組長參加現(xiàn)場安全生產(chǎn)領(lǐng)導(dǎo)小組,項(xiàng)目經(jīng)理為本項(xiàng)目安全生產(chǎn)總負(fù)責(zé),系項(xiàng)目安全生產(chǎn)第一負(fù)責(zé)人,應(yīng)認(rèn)真貫徹執(zhí)行國家和政府部門及上級制定勞動(dòng)保護(hù)及安全生產(chǎn)政策、法令及規(guī)章制度,配備一名專職安全員負(fù)責(zé)本工程安全生產(chǎn)詳細(xì)工作,由專職安全員詳細(xì)負(fù)責(zé)生產(chǎn)安全尋常工作。健全每周一次安全活動(dòng)制度,并有記錄,班組每天進(jìn)行班前班后安全檢查,及時(shí)消除事故隱患,對于已浮現(xiàn)安全責(zé)任事故,應(yīng)堅(jiān)持“三不放過”原則,查找因素,總結(jié)教訓(xùn),寫成書面報(bào)告,通報(bào)全體施工人員及上級主管。貫徹“誰負(fù)責(zé)施工,誰負(fù)責(zé)安全”原則,下達(dá)生產(chǎn)籌劃必要同步下達(dá)書面安全生產(chǎn)技術(shù)交底辦法,并有完整簽字手續(xù)。設(shè)備運(yùn)送吊裝必要有安全生產(chǎn)施工方案,使作業(yè)者人人明白,并嚴(yán)格遵守。進(jìn)入現(xiàn)場施工人員必要戴安全帽,穿戴整潔。依照施工操作需要還應(yīng)發(fā)放如墨鏡、安全靴、手套等勞保用品,教誨恰當(dāng)使用個(gè)人安全保護(hù)用品。工作前或工作中禁止飲酒,施工現(xiàn)場禁止吸煙,如吸煙必要在指定區(qū)域,且煙頭必要在特定容器里進(jìn)行解決,禁止亂扔煙火。高空作業(yè)必要有防墜落辦法,操作人員必要系好安全帽,凹坑洞口應(yīng)有防墜物安全網(wǎng),并有專業(yè)監(jiān)護(hù)。對于違背施工現(xiàn)場安全規(guī)則和其她關(guān)于規(guī)定人員將視違背程序不同進(jìn)行口頭警告或書面罰款甚至解雇解決。本工程專職安全員必要每天須現(xiàn)場巡回檢查,其重點(diǎn)是:a、安全帽、安全帶與否對的使用,人字梯必要牢固無損壞松動(dòng)現(xiàn)象,必要有安全繩,有防滑、防墜落辦法。b、易燃易爆設(shè)備和物品使用存儲與否按規(guī)定辦理。c、動(dòng)火施工范疇內(nèi)有易燃易爆物品,必要事前清除干凈,動(dòng)火證手續(xù)齊全并設(shè)專人監(jiān)護(hù)和配備必要消防設(shè)施,施工完畢后認(rèn)真檢查,不得有剩余火種。d、專職安全員有權(quán)對違背安全生產(chǎn)規(guī)章制度職工進(jìn)行教誨,直到停止其工作,進(jìn)行必要經(jīng)濟(jì)懲罰和行政解決,以保證各項(xiàng)規(guī)章制度貫徹執(zhí)行。1)參加該工程施工人員必要堅(jiān)持“安全第一、防止為主”方針,層層建立崗位責(zé)任制,遵守安全規(guī)程,在任何狀況下,不得違章指揮或違章操作。2)安裝使用腳手架,高凳等使用前必要認(rèn)真檢查,有無糟朽現(xiàn)象。有無探頭板。施工周邊應(yīng)及時(shí)清理障礙物,防止釘子扎腳或其他磕碰工傷事故。3)電氣線路禁止亂拉亂接,同一條線路絕不容許超負(fù)荷使用,保

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論