文檔簡介
ICS27.010
F13NB
Recordnumber:J2491-2018
EnergySectorStandardofthePeople’sRepublicofChina
PNB/T34062-2018
CodeforDesignofDensifiedBiofuelProjectsforHeatingBoilers
Issuedate:2018-04-03Implementationdate:2018-07-01
IssuedbytheNationalEnergyAdministration
EnergySectorStandardofthePeople’sRepublicofChina
CodeforDesignofDensifiedBiofuelProjectsforHeatingBoilers
NB/T34062-2018
Editor-in-chief:ChinaRenewableEnergyEngineeringInstitute
ApprovalDepartment:NationalEnergyAdministration
ImplementationDate:July1,2018
ChinaWater&PowerPress
2018Beijing
NB/T34062-2018
NationalEnergyAdministration
Announcement
No.42018
Accordingtotherelevantprovisionsofthe"NoticeoftheNationalEnergyAdministrationonPrintingand
Distributingthe"MeasuresforStandardizationManagementintheEnergySector(Trial)"andImplementation
Rules"(NationalEnergyAdministrationTechnology(2009)No.52),afterexamination,theNationalEnergy
Administrationapproved168industrystandards,including"GuidelinesfortheEvaluationofVibrationStatus
ofWindTurbines",including56energystandards(NB)and112powerstandards(DL),whicharenowissued.
Annex:IndustryStandardCatalog
NationalEnergyAdministration
2018-04-03
Annex:
IndustryStandardCatalog
Numberusin
NumStandardReplacedApprovalImplementatio
Standardnamegnationalsta
berencodingstandarddatendate
ndard
…
CodeforDesignof
NB/TDensifiedBiofuel
242018-04-032018-07-01
34062-2018ProjectsforHeating
Boilers
…
Ⅰ
NB/T34062-2018
Foreword
Accordingtotherequirementsofthe“NoticeoftheNationalEnergyAdministrationontheIssuanceof
theSecondBatchin2014IndustryStandardsDevelopment(Revision)Plan”(GuonengScienceand
Technology(2015)No.12),afterextensiveinvestigationandresearch,thecodepreparationteamcarefully
summeduppracticalexperienceandformulatedthiscodebasedonextensiveconsultation.
Themaintechnicalcontentsofthiscodeare:basicregulations,processdesign,generallayout,civil
design,electricalengineering,watersupplyanddrainageandheating,fireprotection,environmentalprotection
andenergysaving,laborsafetyandindustrialhygiene.
ThisstandardismanagedbytheNationalEnergyAdministrationandproposedbytheChinaRenewable
EnergyEngineeringInstituteresponsiblefordailymanagement,andtheChinaRenewableEnergyEngineering
Instituteisresponsiblefortheexplanationofspecifictechnicalcontent.Ifyouhavecommentsandsuggestions
duringtheimplementationofthisstandard,pleasesendthemtotheChinaRenewableEnergyEngineering
Institute(Address:No.2,LiupukangNorthStreet,XichengDistrict,Beijing,100120).
Editor-in-chiefofthiscode:AcademyofAgriculturalPlanningandEngineering
NorthwestEngineeringCorporationLimited
Maindraftersofthiscode:ZHAOLixin,MENGHaibo,HUOLili,YAOZonglu
CONGHongbin,ZHAOKai,YUANYanwen,FENGJing
LUOJuan,RENYawei,LILijie,DAIChen
WANGGuan,FENGTaokang,BENXian,ZHANGPeng
Mainreviewersofthiscode:YIYuechun,XIEHongwen,ZHOUFengqi,JIAZhenhang
SHIDianlin,LINCong,YUGuosheng,YANGXiaoliang
SHIShutian,TANGYongjun,TIANXiaoxia,QIUJinsheng
LIUQijun,LIShuangjiang,LIUYuzhuo,HUXiaofeng
GAOLijuan,LIShisheng
Ⅲ
NB/T34062-2018
1.GeneralProvisions
1.0.1Inordertostandardizethedesigncontentanddepthofdensifiedbiofuelprojectsforheatingboilers,
andensurethequalityofsuchprojects,thiscodewasformulated.
1.0.2Thiscodeisapplicabletonew,rebuiltandexpandeddensifiedbiofuelprojectsforheatingboilerswith
annualproductioncapacityof10,000tonsormore(≥10,000tons).
1.0.3Inadditiontothiscode,thedesignofdensifiedbiofuelprojectsforheatingboilersshallalsocomply
withtheregulationsincurrentrelevantnationalstandards.
1
NB/T34062-2018
2.BasicRequirements
2.0.1Projectconstructionshallcomplywithnationalpoliciesandlocalurbanandruralconstructionplanning
requirements.
2.0.2Theengineeringsiteshallhavegoodexternalconditions,includingtransport,powersupply,watersupply,
communicationandterrain,andshallbelocatedinadownwindorcrosswinddirectionoftheannualmaximum
frequencywinddirectioninresidentialareas.
2.0.3Theengineeringdesignscaleshallconsiderthedistributionofbiomassrawmaterials,resources,storage,
transport,andprojectconstruction,aswellasthedemandsofheatingboilers.
2.0.4Thesafetydistancefrominflammablesandexplosivesproductionplants,warehouses,high-voltage
transmissionlines,civilbuildings,etc.shallbefullyconsidered,andcomplywiththeregulationsofthecurrent
nationalstandard''CodeforFireProtectionDesignofBuildings''GB50016.
2.0.5Engineeringconstructionshallbeconducivetoecologyandenvironmentalprotection,andachieveclean
production.
2
NB/T34062-2018
3.ProcessDesign
3.1GeneralRequirement
3.1.1Theprocessdesignshallmeettherequirementsofdensifiedbiofuelproductionforheatingboilers,
productqualityandoutput.
3.1.2Theprocessproceduresincluderawmaterialqualityinspectionandstorage,rawmaterialpretreatment,
compressionforming,dedusting,cooling,packaging,warehousing,factoryinspection,etc.,andshallcomply
withrelevantrequirementsforenvironmentalprotectionandenergyconservation.
3.1.3Theselectionofmainequipmentshallconsiderthefollowingfactors:
1Maintechnicalparameters
2Productioncapacity
3Productquality
4Matchability
5Energyconsumption
6Lifeofwearingparts
7Dustandnoise
8Operationandmaintenance
3.1.4Advancedprocessproceduresandequipmentshouldbeadopted,theequipmentlayoutshouldbe
compactandreasonable,andthereshouldbeenoughspaceforoperation,maintenanceandmanagement.
3.2RawMaterialQualityInspectionandStorage
3.2.1Materialmeasurementandqualityinspectionfacilitiesandequipmentshallbeinstalled.
3.2.2Thecapacityofrawmaterialstoragefacilitiesshallmeettheproductionneedsofnotlessthan7days.
3.2.3Therawmaterialstorageshouldadoptrawmaterialshedsorrawmaterialwarehouses,whichshould
ensureventilation,fireprevention,rainandsnowprevention,dedustingandsmoothtransportofrawmaterials.
3.3RawMaterialPretreatment
3.3.1Rawmaterialpretreatmentshouldincludeimpuritycleaning,crushing,drying,mixing,etc.,andcanbe
appropriatelyincreasedordecreasedaccordingtotheneedsoftheproductionprocess.
3.3.2Rawmaterialimpuritycleaningfacilitiesshouldbeestablished.
3.3.3Theproductioncapacityofthecrushingprocessshallbegreaterthan1.3times(>1.3×)theforming
productioncapacity.
3
NB/T34062-2018
3.3.4Accordingtotheneedsoftheformingprocess,aftertherawmaterialsarecrushed,mixingequipmentcan
beutilizedbeforedryingandcompressionforming.
3.4CompressionForming
3.4.1Thestoragebinshouldbesetinfrontoftheformingmachine,andthestoragecapacityofthestoragebin
shallmeetthecontinuousproductionneedsoftheformingequipment.
3.4.2Theformingequipmentshallcomplywiththeprovisionsofthecurrentindustrystandard"Technical
conditionsfordensifiedbiofuelmoldingequipment"NY/T1882,andshallensureproductqualityandcapacity
requirements.
3.4.3Thespareformingequipmentshouldbereasonablyconfiguredaccordingtotheneedsoftheproduction
capacity.
3.4.4Theformingequipmentshallbearrangedreasonably,anditshouldbearrangedinparallelwhenusing
multiplesetsofequipment.
3.5Dedusting
3.5.1Theproductionworkshopshallbeequippedwithadedustingsystem,andthedustconcentrationofthe
workshopshallcomplywiththecurrentnationalstandard"OccupationalExposureLimitsofHazardous
FactorsintheWorkplace"GBZ2,andtheemissionstandardshallcomplywiththecurrentnationalstandard
"DesignHygieneStandardsforIndustrialEnterprises"GBZ1and"IntegratedEmissionStandardofAir
Pollutants"GB16297.
3.5.2Thedust-dispersingprocessequipmentshouldbeclosed,andthedust-proneareashouldbeequipped
withasuctionhoodtocapturethedust.
3.5.3Thededustingsystemshalltakemeasurestopreventsecondarypollutionofdust.
3.6Cooling,PackagingandProductInspection
3.6.1Aircoolingorothercoolingmethodsshallbeselectedaccordingtoprocessrequirements.
3.6.2Itisadvisabletoinstallpackagingequipmentafterthemeasuringprocess,andalsoconfigurebulk
storagetanks.
3.6.3Theproductionfacilityshouldbeequippedwithaproducttestinglaboratoryandrelevanttesting
equipment.
4
NB/T34062-2018
4GeneralLayout
4.0.1Thegenerallayoutshallmeetthefollowingrequirements:
1Designmissionandrequirementsoftheurbanandruralconstructionplanningdepartmentforthe
selectedplantsite.
2Theprovisionsofthecurrentnationalstandard"DesignCodeofIndustrialCorporationSitePlanning"
GB50187.
3Designedaccordingtotheplannedscale,takingintoaccountfollow-upprojectsandunifiedplan
planning.
4Thelayoutofthemainandauxiliarybuildingsisreasonable,theproductionlineiscompactand
standardized,andtheflowofpeopleandlogisticsareseparated.
5Onthepremiseofmeetingproductionrequirements,thelayoutiscompactandreasonable,savingland
andreducingtheamountofrequiredearthandstone.
6Comprehensiveconsiderationofbuildinglayout,transport,roads,powersupplylines,watersupply
anddrainagepipelines,industrialpipelines,fireprotection,greening,environmentalprotection,etc.
4.0.2Accordingtotheproductionprocessandfunction,theplantareashouldbedividedintoofficearea,raw
materialarea,productionareaandfinishedproductarea,andeachareashouldbecloselyconnectedand
properlyseparated.
4.0.3Thebuildinglayoutshallmeetthefollowingrequirements:
1Thebuildingspacingmeetstherequirementsoffireprotection.
2Thebuildinghasgoodnaturallightingandventilationconditions.
3Theimpactofproductionnoiseanddustontheoverallenvironmentisconsidered.
4.0.4Theplanttrafficsystemshallbedesignedaccordingtotheflowofpeople,logisticslinesandthetotal
planttraffic.Theroadsintheplantshallmeetthefollowingrequirements:
1Theroadsintheplantareashallbesmoothtofacilitatethepassageofvehicles.Theroadsforthe
transportofrawmaterials,finishedproductsandmainpeopleshouldusetwo-waylanes.
2Accordingtourbanandruralroadplanningprinciples,andtheprincipleofdivisionofpeopleand
material,thefactoryentrancesandexitsshallbereasonablyset,andthereshallbenolessthan2entrancesand
exits.
3Fireexitsandemergencyexitsshallbesetupwithobvioussigns.
4Theroadintheplantareashouldbehardenedpavement.
5
NB/T34062-2018
5CivilDesign
5.1GeneralRequirements
5.1.1Thespecificconditionsofproductionscale,site,materialsandconstructionshallbecomprehensively
considered,andcivildesignshallbecarriedoutinaccordancewiththeproductionprocess.
5.1.2Theclassificationoffirehazardstandardsforproductionandauxiliarybuildingsshallcomplywiththe
provisionsofthecurrentnationalstandard"CodeforFireProtectionDesignofBuildings"GB50016.
5.2ProductionBuildings
5.2.1Productionbuildingsshouldincluderawmaterialwarehouse,productionworkshop,finishedproduct
warehouse,etc.
5.2.2Productionbuildingsshallbearrangedinzones,andonthepremiseofmeetingtherelevantrequirements
forfireprotectionandevacuation,localconjoineddesigncanbecarriedout.
5.2.3Theopening,spanandheightoftheproductionbuildingshallbedeterminedaccordingtotheproduction
scaleandprocesslayout.
5.2.4Theindoorgroundelevationoftheproductionbuildingshallnotbelowerthantheoutdoorgrounddesign
elevation,andnotlessthan0.3m(≥0.3m).
5.2.5Productionbuildingsshouldbeequippedwithlargeequipmenttransportchannels.
5.2.6Theflooroftheproductionbuildingshallbehardened,flat,wear-resistant,moisture-proof,andstrong
enoughtomeettheproductionneeds.
5.2.7Theliveloadontheflooroftheproductionbuildingcanbecalculatedaccordingtothelocalloadand
concentratedloadcausedbyheavyobjectsusedinproduction,installationandmaintenance,stackingmaterials,
transportvehicles,etc.
5.2.8Aplatformforloadingandunloadingmaterialsandawningshallbeinstalledattheexitofthefinished
productwarehouse.
5.3AccessoryBuildings
5.3.1Theproductionworkshopshallbeequippedwithacontrolroomaccordingtotheneedsoftheequipment,
anditslocationshallmeetthefollowingrequirements:
1Itisadjacenttotheproductionworkshop,andeasytoobserve,operateanddispatch.
2Ithasgoodventilationandlighting,andavoidsdirectsunlightandglare.
3Theimpactofvibrationissmall,andthenoiseshallnotbehigherthan70dB(≤70dB).
5.3.2Thedesignofthecontrolroomshallmeetthefollowingrequirements:
1ThefireresistancelevelshallnotbelowerthanClass2.
6
NB/T34062-2018
2Theindoorclearheightshallnotbelessthan3m(≥3m),andtheoverheadfloorshallbetreatedfor
fireprevention.
3Theindoortemperatureofthemicrocomputercontrolroomshallmeettherequirementsofthecurrent
nationalstandard"Industrial-processmeasurementandcontrolequipment-OperatingconditionsPart1:
Climaticconditions"GB/T17214.1.
4Cablemaintenanceisconvenient.
5Thefloorshoulduseinsulationmaterialandanti-staticmeasuresshouldbetaken.
5.3.3Thetestingroomshallmeetthetestingneedsofrawmaterialsandfinishedproducts.
5.3.4Theofficespaceshallbekeptatanappropriatedistancefromtheproductionareatoavoidtheeffects
ofnoise,vibrationanddust.
5.3.5Anindependentelectromechanicalequipmentmaintenanceroomandasparepartsstorageroomshall
bemaintainedintheplantarea.
7
NB/T34062-2018
6ElectricalEngineering
6.1LoadandPowerSupply
6.1.1Theproductionpowerloadshallbeathree-levelload.Itisadvisabletousethedemandcoefficient
methodtocalculatethepowerload.
6.1.2Thelow-voltagedistributioncircuitshallbedividedaccordingtotheproductionworkshop,production
line,worksection,processorunit.
6.1.3Drying,compressionforming,anddedustingequipmentcanbesettoutilizeamanuallyswitchedstandby
circuit.
6.1.4Thelightingpowersupplyintheproductionworkshopshouldbepoweredbyaspeciallinefroma
low-voltagedistributionsystem.Whensharedwiththepowerdistribution,amainlightingswitchandpower
distributioncabinetseparatefromthepowerdistributionshouldbeinstalledafterenteringtheproduction
workshop.
6.2PowerDistributionandLighting
6.2.1Theprotectionlevelofmotorsandelectricalappliancesshallmeettheregulationsofthecurrentnational
standard''DegreesofProtectionProvidedbytheIntegralDesignofRotatingElectricalMachines(IPcode)
-Classification''GB/T4942.1.
6.2.2Thesocketsintheproductionworkshopshouldadoptindependentcircuitpowerdistributionandbe
equippedwithcurrentprotectiondeviceswithexplosion-prooffunctions.
6.2.3Whenwiring,thefillingcoefficientofthecableincabletrays,ductsandconduitsshouldnotbelarger
than40%.Theinfluenceoftemperatureriseonthesafecarryingcapacityandtheconvenienceofinstallation
andmaintenanceshallbeconsidered.
6.2.4Theproductionworkshopshallhaveproductionlighting,dutylightingandemergencylighting,andthe
firepumproomandproductionmonitoringareashallhavebackuplighting.
6.2.5Efficientandeasy-to-maintaindust-proofandexplosion-prooflampsshallbeselected.
6.3LightingProtectionandGroundingDesign
6.3.1Variousgroundingprotectionintheproductionworkshopshouldsharethegroundingdevice,andthe
groundingresistanceshallnotbelargerthan1Ω;thefactoryelectricalsystemshouldadopttheTN-Sor
TN-C-Sgroundingprotectionsystem.
6.3.2Anequipotentialconnectionsystemshallbeusedintheproductionworkshop.Measuresshouldbetaken
topreventelectricshockinareasoutsidetheequipotentialactionarea.
6.3.3Theincomingswitchofthedryinganddedustinglinkshouldbeequippedwithanalarmandleakage
protectiondevicewithdelayedaction.
8
NB/T34062-2018
7.WaterSupplyandDrainageandHeating
7.1WaterSupply
7.1.1Twowatersupplymainsshallbeinstalledintheplantarea,oneofwhichshallmeettheneedsofthe
wholeplantproductionanddomesticwater,andtheotherofwhichshallmeetthefirewaterneedsofthewhole
plant.
7.1.2Theproductionwaterconsumptionshouldbe1.10timesto1.15times(1.10-1.15×)thesumofthe
productionwaterconsumptionofeachprocess,andthewatersupplypipeintotheplantareashallbeequipped
withatotalmeteringdevice.
7.2Drainage
7.2.1Thedrainagesystemoftheplantareashalladoptrainandsewagediversion.Thedrainageshallcomply
withtheregulationsofthecurrentnationalstandard"CodeforOutdoorDrainageDesign"GB50014.
7.2.2Theroadsintheplantareashallhaveagooddrainagesystem.
7.3Heating
7.3.1Accordingtolocalclimaticconditions,aheatingsystemcanbeinstalledintheproductionworkshop,and
theindoortemperatureshallmeettheproductionrequirements.
7.3.2Theproductionworkshopshalladoptaheatdissipationdevicethatdoesnoteasilyaccumulatedust,is
easytoclean,andhasgoodcorrosionresistance.
7.4VentilationandAirConditioning
7.4.1Theventilationsystemshallcomplywiththeregulationsofthecurrentnationalstandard"Occupational
ExposureLimitsofHazardousFactorsintheWorkplace"GBZ2.
7.4.2Therawmaterialwarehouseandfinishedproductwarehousecanadoptnaturalventilationormechanical
ventilation.
7.4.3Whenthetemperatureintheproductionworkshopexceeds36℃,coolingmeasuresshallbetaken.
9
NB/T34062-2018
8FireProtection
8.0.1Thefirehazardlevelandfireresistancelevelofthemainbuildings(structures)shallcomplywiththe
regulationsofthecurrentnationalstandard"CodeforFireProtectionDesignofBuildings"GB50016.
8.0.2Inthegenerallayoutoffireprotection,thefirepartitions,fireseparationdistances,andfirepassagesof
themainbuildings(structures)shallcomplywiththeregulationsofthecurrentnationalstandard"Codefor
FireProtectionDesignofBuildings"GB50016.
8.0.3Thedistancefromthefurthestworkingplaceintheproductionworkshoptotheexternalexitshallmeet
thenationalfiresafetymanagementregulations,andthereshouldbenolessthan2entrancesandexits.
8.0.4Whentheprocessconditionspermit,appropriatefireseparationcanbecarriedoutinthefirepartition.
8.0.5Thefirewatersupplyshallbesetupwithindependentwatersource,andequippedwithafirestorage
tank,fireboosterpumpandotherfacilities.Thecapacityofthefirestoragetankshallbedeterminedaccording
tothesumoftheindoorandoutdoorfirewaterconsumptionduringthefireduration.Thefiredurationusedto
calculatethecapacityofthefirestoragetankshallbe3h.
8.0.6Thefirewatersupplynetworkshallformaringnetwork.Thewaterdeliverypipeforsupplyingwaterto
thering-shapedpipenetworkshallconsistofnolessthantwopipes.Ifonepipefails,thenthetotalcapacityof
theremainingpipesshallbesufficienttomeetthefirewaterdemand.
8.0.7Thearrangementofindoorandoutdoorfire-fightingequipmentshallcomplywiththeregulationsofthe
currentnationalstandard"CodeforFireProtectionDesignofBuildings"GB50016.
8.0.8Thedistributionboxofthewarehousewithfireriskshallbesetseparatelyandinstalledinthewarehouse
dutyroomoroutsidethewarehouse.Thewiringinthewarehouseshouldbelaidwithsteelpipes.
8.0.9Lightingdistributionlinesandcontrolcircuitsshouldbedividedaccordingtofirepartitions.
8.0.10Themainbuilding(structure)shallbeequippedwithfireevacuationindicationsignsandanautomatic
firealarmsystem.
8.0.11Dedustingpipesshalltakeexplosion-proofandpressure-reliefmeasures.
10
NB/T34062-2018
9EnvironmentalProtectionandEnergySaving
9.1EnvironmentalProtection
9.1.1Thedomesticsewageshallbedischargedafterreachingthestandardaftertreatment.
9.1.2Thenoiseintheplantareacomplieswiththeregulationsofthecurrentnationalstandard''Emission
StandardforIndustrialEnterprisesNoiseatBoundary''GB12348and''CodeforDesignofNoise
ControlinIndustrialEnterprises''GB/T50087.
9.1.3Variousexhaustemissionsintheproductionprocessshallmeetthenationalrelevantemission
requirements.
9.2EnergySaving
9.2.1ProductsprohibitedoreliminatedbytheStateshallnotbeused.
9.2.2Themotorenergyconsumptionoftheformingequipmentshallmeettheregulationsofthecurrent
nationalstandard''MinimumAllowableValuesofEnergyEfficiencyandEnergyEfficiencyGrades
forSmallandMediumThree-phaseAsynchronousMotors''GB18613.
9.2.3Theprocessdesignplanshallminimizethenumberofstart-stopsoftheproductionline,reducethe
no-loadoperationtime,andensuretheefficientandstableoperationoftheequipment.
11
NB/T34062-2018
10LaborSafetyandIndustrialHygiene
10.0.1Asafetyeducationroomandarestroomshallbesetupintheplantarea,andcomplywiththe
regulationsofthecurrentnationalstandard"HygienicstandardsfortheDesignofIndustrialEnterprises"GBZ
1.
10.0.2Thetransmissionandexposedrunningpartsshallbeequippedwithsafetyshieldsandothersafety
protectiondevices.Forthevisiblerunningpartsoftheequipment,protectivebafflesmustbeinstalled.
10.0.3Thepitmustbecoveredorfenced.
10.0.4Thehigh-altitudeoperationareashallbeequippedwithoperatingandmaintenanceplatformsand
railings,ortakeothersafetymeasures.
10.0.5Places,facilitiesandequipmentwheresafetyhazardsorpotentialsafetyrisksexistshallbeclearlyset
withsafetysignsandmarkings.Thesettingofsafetysignsandmarkingsshallcomplywiththeregulationsof
thecurrentnationalstandard"SafetySignsandGuidelinesfortheUse"GB2894and"SafetyColors"GB
2893.
10.0.6Thelightingintheplantareashallmeettheregulationsofthecurrentnationalstandard"Standardfor
LightingDesignofBuildings''GB50034.
12
NB/T34062-2018
ExplanationofWordinginthisCode
1Inordertofacilitatedifferenttreatmentintheimplementationoftheprovisionsofthiscode,termswith
differentdegreesofstrictnessareexplainedasfollows:
1)expressverystrictlyandisabsolutelynecessary:
use"must"forpositivewordsand"mustnot"fornegativewords.
2)expressstrictlyandshallbedoneundernormalcircumstances:
use"shall"forpositivewordsand"shallnot"or"maynot"fornegativewords.
3)expresssomechoiceandshallbethefirstprioritywhenconditionspermit:
use"should"forpositivewordsand"shouldnot"fornegativewords.
4)usetheword"may"toexpressthatyouhaveachoiceandcandoitundercertainconditions.
2Theprovisionthatitshallbeimplementedaccordingtootherrelevantstandardsisexpressedas:"shall
complywithregulationsof"or"shallbeimplementedaccordingto".
13
NB/T34062-2018
ListofQuotedStandards
"SafetyColor"GB2893
"SafetySignsandGuidelinesfortheUse"GB2894
"DegreesofProtectionProvidedbytheIntegralDesignofRotatingElectricalMachines(IPcode)
-Classification"GB/T4942.1
"EmissionStandardforIndustrialEnterprisesNoiseatBoundary"GB12348
"IntegratedEmissionStandardofAirPollutants"GB16297
"Industrial-pr
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 人教版七年級數(shù)學(xué)上冊:2.1《整式》聽評課記錄5
- 五年級上冊數(shù)學(xué)聽評課記錄《4.5 探索活動:梯形的面積》(3)-北師大版
- 中圖版地理七年級下冊《第五節(jié) 黃土高原》聽課評課記錄5
- 青島版八年級上冊數(shù)學(xué)聽評課記錄《3-3分式的乘法與除法》
- 小學(xué)二年級數(shù)學(xué)口算速算試題
- 小學(xué)二年級第一學(xué)期班主任工作總結(jié)
- 五年級口算題帶答案
- 浙教版數(shù)學(xué)七年級下冊3.2《單項式的乘法》聽評課記錄
- 粵人版地理八年級下冊《第一節(jié) 地理區(qū)域》單元整體聽課評課記錄2
- 聽評課記錄三年級語文
- 云南省普通初中學(xué)生成長記錄模板-好ok
- SB/T 10415-2007雞粉調(diào)味料
- JB/T 20036-2016提取濃縮罐
- 考古繪圖基礎(chǔ)
- GB/T 3452.4-2020液壓氣動用O形橡膠密封圈第4部分:抗擠壓環(huán)(擋環(huán))
- GB/T 32574-2016抽水蓄能電站檢修導(dǎo)則
- 《社會主義市場經(jīng)濟(jì)理論(第三版)》第十三章社會主義市場經(jīng)濟(jì)標(biāo)準(zhǔn)論
- 變更索賠案例分析
- 2022年4月自學(xué)考試06093《人力資源開發(fā)與管理》歷年真題及答案
- 《花婆婆》兒童繪本故事
- DB44∕T 2149-2018 森林資源規(guī)劃設(shè)計調(diào)查技術(shù)規(guī)程
評論
0/150
提交評論