直流電路主講人牛小偉ZHENGZHOURAILWAYVOCATIONAL&TECHNICALCOLLEGE客車電氣裝置/BUSELECTRICALINSTALLATION主講人牛小偉SpeakerNiuxiaowei直流電路發(fā)電車I號機(jī)組直流報警保護(hù)電路如圖3一22所示。TheDCprotectioncircuitoftheIgeneratorcarisshowninthefollowingfigure.該電路可以實現(xiàn)過流預(yù)報警、過流脫扣報警、逆功率脫扣報警、繞組高溫報警和高水溫報警,另外還可以進(jìn)行電路的試報警及報警時的消音、報警故障處理后的復(fù)位等操作。Thiscircuitcanrealizeover-currentpre-alarm,over-currenttrippingalarm,reversepowertrippingalarm,windinghightemperaturealarm,andhighwatertemperaturealarm.Inaddition,itcanalsoperformcircuittestalarm,noisereductionduringalarm,resettingafteralarmfaulthandling,andotheroperations.發(fā)電車三臺機(jī)組的報警保護(hù)電路原理相同,其中I號機(jī)組幾個報警保護(hù)電路的工作過程分析如下:Theprincipleofthealarmprotectioncircuitofthethreeunitsofgeneratorcaristhesame.Theoperatingprocessisanalyzedasfollow:

2.發(fā)電車直流報警保護(hù)電路

TheDCalarmingprotectioncircuitofgeneratorcar.直流電路主開關(guān)電路Mainswitchingcircuits直流電路當(dāng)I號發(fā)電機(jī)輸出線電流超過預(yù)報警電流600A時,WhentheoutputlinecurrentoftheIgeneratorcarexceedsthepre-alarmcurrent600A使141與700號線接通,繼電器1KA6得電吸合,接通報警電路中的721號線與723號線間常開觸點,報警指示燈7HL1點亮,同時,繼電器7KA2得電吸合,電鈴電路接通,電路實現(xiàn)聲光雙報警。Thenline141andline700areconnected,andrelay1KA6ispoweredonandclosed;thenormallyopencontactbetweenline721andline723inthealarmcircuitisconnected,andthealarmindicatinglamp7HL1lightsup.Therefore,relay7KA2canbepoweredonandclosed,theelectricbellcircuitisconnected,andthecircuitrealizesbothsoundandlightalarm.1QF主開關(guān)的17與18號端子間的微動開關(guān)閉合,Thesensitiveswitchbetweenterminals17and18ofthe1QFmainswitchisclosed.電鈴1KA6自鎖觸點相應(yīng)的電氣通路如下:Thecorrespondingelectricalpathwaysareasfollows:過流預(yù)報警Over-currentpre-alarm(1)直流電路指示燈7HLI電路(光報警):704(+)-7FU7-733-721-1KA6(閉合)->723-7HL1線圈-7(X)。7KA2線圈電路704(+)-7FU7-733-721-1KA6(閉合)--723-7V1-732-7KA2線圈一70007KA1觸點斷開,電鈴斷電直流電路電警笛(7JD1)電路Electricalarmcircuit704(+)-7FU7-733-721--7KA2(閉合closed)-731-7KA1(常閉normallyclosed)-730-7JD1700。電路中的Vol為續(xù)流二極管,它可以釋放7JD1中的線圈在通電與斷電時所產(chǎn)生的感應(yīng)電流,以防止影響其他電路的正常工作。The

freewheeling

diodeVo1inthiscircuitcanreleasetheinducedcurrentofthecoilin7JD1whichisgeneratedwhenthecoilispoweredonandoff,sothatthediodecanenablethenormaloperationsofothercircuits.消音電路Noisereductioncircuit當(dāng)出現(xiàn)報警后,按下消音按鈕7SB2,7KA1線圈得電,其常閉觸點斷開,電警笛電路被切斷,電警笛停止工作。Whenanalarmoccurs,pressthenoisereductionbutton7SB2.Thenthecoil7KA1ispoweredon,itsnormallyclosedcontactisdisconnected,andtheelectricsirencircuitispoweredoff.Finally,theelectricalarmstopsworking.7KA1觸點斷開,電鈴斷電直流電路主開關(guān)1QF自動分閘,電路實現(xiàn)脫扣功能,同時主開關(guān)上的21與22接線端間微動開關(guān)閉合,140與700號線接通(見圖3一14),繼電器1KA7得電吸合,接通報警電路中的721號線與724號線間常開觸點,報警指示燈7HL2及報警動作繼電器7KA2得電,電路實現(xiàn)聲光雙報警。Themainswitch1QFisautomaticallyopened,andthecircuitrealizesthetrippingfunction.Meanwhile,thesensitiveswitchbetweentheterminals21and22onthemainswitchisclosed,thelines140and700areconnected(seeFigure3-14),therelay1KA7ispoweredonandclosed.Thenthenormallyopencontactbetweenline721andline724inthealarmcircuitisconnectedandthealarmindicatinglamp7HL2andthealarmrelay7KA2arepoweredon,sothecircuitrealizesbothsoundandlightalarm.當(dāng)I號發(fā)電機(jī)輸出線電流超過脫扣(分閘)電流2000A時,WhentheoutputlinecurrentoftheIgeneratorexceedsthetripping(opening)currentof2000A,過流脫扣報警Over-currenttrippingalarm(2)直流電路如果不及時分閘,將會使發(fā)電機(jī)繞組燒損,引起嚴(yán)重后果。Ifthebrakesarenotopenedintime,thegeneratorwindingswillbeburned,causingseriousconsequences.當(dāng)發(fā)電機(jī)輸出干線上出現(xiàn)大于10%的逆功率時Whenthereisareversepowermorethan10%ontheoutputmainlineofthegenerator.1KR線圈將動作,142與700號線接通,繼電器1KA5得電吸合,195與186線間1KA5的常開觸點閉合,主開關(guān)的分閘電路被接通而實現(xiàn)自動分閘(見圖3一14),同時721與725號線間常開觸點接通,電路實現(xiàn)聲光雙報警。The1KRcoilwilloperate,theline142andline700willbeconnected,andtherelay1KA5willbepoweredonandclosed.Meanwhile,thenormallyopencontactof1KA5betweenlines195and186isclosed,theopeningcircuitofthemainswitchisconnectedtorealizeautomaticopening(seeFigure3-14),andthenormallyopencontactbetweenline721andline725isconnected.Thenthecircuitcanrealizesoundandlightalarm.逆功率脫扣報警Reversepowertrippingalarm(3)當(dāng)雙機(jī)并車或因其他原因造成I號機(jī)組功率倒灌(逆功率:一般而言,發(fā)電機(jī)的功率方向應(yīng)該為由發(fā)電機(jī)流向母線,但是當(dāng)發(fā)電機(jī)失磁或其他某種原因,發(fā)電機(jī)有可能變?yōu)殡妱訖C(jī)運行,即從系統(tǒng)中吸取有功功率。這就是逆功率。)時,

WhenthetwogeneratorsoperateinparallelorthepowerofunitIisreversed(onreversepower)causedbyotherreasons.直流電路繞組高溫報警后應(yīng)立即減載或停止供電,待查明原因并作相應(yīng)處理后才可恢復(fù)正常供電。Afterthewindinghightemperaturealarm,theloadshouldbereducedorthepowersupplyshouldbecutoffimmediately.Whenthecauseisfoundoutandthecorrespondingtreatmentistaken,thepowersupplycanberestored.當(dāng)發(fā)電機(jī)電樞繞組內(nèi)部由于某種原因溫度過高(超過155℃)時,繞組高溫繼電器1ZWJ動作,721號線與726號線間觸點接通,報警電路發(fā)出聲光報警。Whentheinternaltemperatureofthegeneratorarmaturewindingistoohigh(exceeding155℃)forsomereason,thewindinghigh-temperaturerelay1ZWJoperates,andthecontactbetweenline721andline726isconnectedandthealarmcircuitemitsanaudibleandvisualalarm.繞組高溫報警Windinghightemperaturealarm(4)當(dāng)柴油機(jī)的水溫超過90℃時,繼電器IKA3得電吸合,報警電路中的721號線與727號線接通,電路實現(xiàn)聲光雙報警。Whenthewatertemperatureofthedieselengineexceeds90°C,therelayIKA3ispoweredonandclosed,andtheline721andline727inthealarmcircuitareconnected.Thenthecircuitcanreal

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論