版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認(rèn)領(lǐng)
文檔簡介
10千伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案
(2023版)
10千伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
目錄
前言...........................................................................1
修編說明.........................................................................2
1概述...........................................................................3
1.1額定參數(shù).................................................................3
1.2使用條件.................................................................3
1.3設(shè)備選型..................................................................3
1.4絕緣介質(zhì)..................................................................4
210kV環(huán)保氣體絕緣環(huán)網(wǎng)柜........................................................5
2.1標(biāo)準(zhǔn)化原則...............................................................5
2.2.1單元柜方案.........................................................5
2.2.2共箱型方案.........................................................5
2.2.4預(yù)裝式變電站中環(huán)網(wǎng)柜組合方案......................................6
2.3一次接口及土建接口....................................................9
2.3.1柜寬...............................................................9
2.3.2柜深................................................................9
2.3.3柜高................................................................9
234儀表箱.............................................................10
235主開關(guān)滅弧方式....................................................10
2.3.6殼體(氣箱)材質(zhì)...................................................10
2.3.7殼體(氣箱)材質(zhì)厚度..............................................10
2.3.8柜體框架材質(zhì).......................................................10
2.3.9柜體材質(zhì)厚度....................................................
23.10門板材質(zhì).........................................................
2.3.11門板材質(zhì)厚度....................................................
2.3.12柜體防護等級...................................................
2.3.13主母線擴展方式..................................................
2.3.14可接最多次電纜數(shù)(每相)......................................
2.3.15一次電纜接線高度...............................................
2.3.16一次電纜排列方式...............................................
2.3.17一次電纜固定位置...............................................
2.3.18一次電纜孔直徑..................................................12
2.3.19一次電纜孔位置....................................................12
2.3.20一次接地排規(guī)格....................................................12
2.3.21一次接地排貫穿孔.................................................12
2.3.22儀表箱二次走線孔.................................................13
2.3.23地腳開孔位置......................................................13
2.3.24壓力釋放通道方向.................................................14
2.3.25基礎(chǔ)槽鋼.........................................................14
2.3.26標(biāo)準(zhǔn)化設(shè)計尺寸....................................................14
2.3.26.1側(cè)擴方式....................................................14
2.3.26.2頂擴方式...................................................17
10千伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
2.3.27環(huán)網(wǎng)箱...........................................................18
2.3.27.1環(huán)網(wǎng)箱外形................................................18
2.3.27.2開門所需空間..............................................19
2.3.28地基接口........................................................19
310kV圉體絕緣環(huán)時柜..........................................................22
3.1標(biāo)準(zhǔn)化原則.............................................................22
3.2典型結(jié)構(gòu)方案............................................................22
3.2.1單元柜方案.......................................................22
3.2.2環(huán)網(wǎng)箱中環(huán)網(wǎng)柜組合方案...........................................25
3.2.3預(yù)裝式變電站中環(huán)網(wǎng)柜組合方案....................................25
3.3一次接口及土建接口....................................................28
3.3.1柜寬.............................................................28
3.3.2柜深..............................................................28
3.3.3柜高..............................................................28
3.3.4儀表箱............................................................28
3.3.5主開關(guān)滅弧方式....................................................28
3.3.6主母線............................................................28
3.3.7外露絕緣件接地方式...............................................28
3.3.8柜體框架材質(zhì)......................................................29
3.3.9柜體板材厚度......................................................29
3.3.10門板材質(zhì).........................................................29
3.3.11門板材質(zhì)厚度....................................................29
3.3.12柜體防護等級.....................................................29
3.3.13每相最多可接一次電纜數(shù)..........................................29
3.3.14一次電纜接線高度.................................................29
3.3.15一次電纜排列方式...............................................29
3.3.16一次電纜固定位置.................................................29
3.3.17一次電纜安裝端相間距............................................30
3.3.18一次電纜孔直徑...................................................3()
3.3.19?次電纜孔位置..................................................30
3.3.20主母線擴展方式...................................................30
3.3.21擴展母線接線端對地高度..........................................30
3.3.22擴展母線接線端中心距柜體前底框架深度...........................31
3.3.23擴展母線套管位置尺寸............................................31
3.3.24擴展母線尺寸.....................................................32
3.3.25擴展母線套管尺寸................................................32
3.3.26一次接地排規(guī)格...................................................32
3.3.27一次接地排位置尺寸...............................................32
3.3.28柜體并柜形式....................................................33
3.3.29多回路柜體井柜尺寸..............................................33
3.3.30儀表室二次走線孔................................................34
33.31地腳開孔位置....................................................34
3.3.32壓力釋放通道方向................................................35
10千伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
3.3.33基礎(chǔ)槽鋼.........................................................35
3.3.34環(huán)網(wǎng)箱...........................................................35
3.3.35地基接口........................................................35
410kV常壓密封空氣絕緣環(huán)網(wǎng)柜...................................................36
4.1標(biāo)準(zhǔn)化原則..............................................................36
4.2典型結(jié)構(gòu)方案............................................................36
4.2.1單元柜方案.......................................................36
4.2.2共箱型方案.......................................................37
4.2.3環(huán)網(wǎng)箱中環(huán)網(wǎng)柜組合方案...........................................38
4.2.4預(yù)裝式變電站中環(huán)網(wǎng)柜組合方案.....................................38
4.3一次接口及土建接口....................................................42
4.3.1柜寬..............................................................42
4.3.2柜深..............................................................42
4.3.3柜高...............................................................42
4.3.4儀表箱外形尺寸...................................................43
4.3.5主開關(guān)滅弧方式...................................................43
4.3.6柜體框架材質(zhì)......................................................43
4.3.7柜體材質(zhì)厚度.....................................................43
4.3.8門板材質(zhì)..........................................................43
4.3.9門板材質(zhì)厚度.....................................................43
4.3.10柜體防護等級.....................................................44
4.3.11主母線擴展方式..................................................44
4.3.12可接最多一次電纜數(shù)(每相)......................................44
4.3.13一次電纜接線高度.................................................44
4.3.141次電纜排列方式................................................44
4.3.15一次電纜固定位置................................................44
4.3.16一次電纜孔直徑..................................................44
4.3.17一次電纜孔位置...................................................44
4.3.18一次接地排規(guī)格...................................................45
4.3.19?次接地排貫穿孔.................................................45
4.3.20儀表箱二次走線孔.................................................45
4.3.21地腳開孔.........................................................46
4.3.22壓力釋放通道方向................................................46
4.3.23基礎(chǔ)槽鋼.........................................................47
4.3.24標(biāo)準(zhǔn)化設(shè)計尺寸..................................................47
4.3.24.1側(cè)擴方式....................................................47
4.3.24.2頂擴方式...................................................48
4.3.25環(huán)網(wǎng)箱............................................................49
5.3.26地基接口.......................................................49
5.1儀表門..................................................................50
5.2柜內(nèi)二次端子............................................................50
6關(guān)鍵元件及要求................................................................52
6.1集中式站所終端配套電磁式互感器/低功耗互感器...........................52
III
10千伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
6.1.1電磁式電流互感器................................................52
6.1.2低功耗電流互感器..................................................53
6.1.3電磁式電壓互感器.................................................54
6.1.4低功耗電壓互感器.................................................55
6.2分散式站所終端配套電磁式互感器/低功耗互感器...........................56
6.2.1電流互感潴/傳感器.................................................56
6.2.2電壓互感器........................................................56
6.3環(huán)網(wǎng)柜門板..............................................................56
6.3.1門板顏色.........................................................56
6.3.2門板加工...........................................................56
6.3.3銘牌..............................................................57
6.3.4模擬母線..........................................................57
6.4.1環(huán)網(wǎng)箱材質(zhì)........58
58
6.4.2環(huán)網(wǎng)箱顏色.......58
6.4.3環(huán)網(wǎng)箱材質(zhì)厚度……58
58
6.5防凝露措施.............59
61
6.5.1結(jié)構(gòu)防凝露措施....61
6.5.2電氣防凝露措施....62
62
6.5.3關(guān)鍵元件防凝露措施63
6.6環(huán)網(wǎng)箱外露標(biāo)準(zhǔn)部件材質(zhì).63
63
6.7環(huán)網(wǎng)箱外殼防腐措施.....64
6.8環(huán)網(wǎng)箱外殼防塵措施……64
65
7標(biāo)準(zhǔn)化設(shè)計樣機試驗細(xì)則.......67
7.1樣柜試制方案及試驗項目..69
74
7.1.1單元柜...........78
7.1.2環(huán)網(wǎng)箱...........
7.2依據(jù)標(biāo)準(zhǔn)...............
7.3單元柜試驗方案.........
7.4環(huán)網(wǎng)箱試驗方案........
附錄A環(huán)網(wǎng)柜內(nèi)部電瓠試驗方法...
附錄B環(huán)網(wǎng)箱內(nèi)部電弧試驗方法...
附錄C二次原理圖..............
10千伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
前言
按照公司“1135”配網(wǎng)運行服務(wù)管理要求,提高設(shè)備選型標(biāo)準(zhǔn),健全質(zhì)量控制
體系,提升配電網(wǎng)設(shè)備耐用性,突出設(shè)備好的核心,依據(jù)安全可靠、堅固耐用、
標(biāo)準(zhǔn)統(tǒng)一、通用互換的原則,全面推進配電設(shè)備標(biāo)準(zhǔn)化工作。
為滿足不同廠家設(shè)備在一定范圍和一定時期的通用互換使用,提升環(huán)網(wǎng)柜的
運維便利性,公司組織中國電力科學(xué)研究院有限公司、設(shè)計院、運行單位、制造
企業(yè)、檢測機構(gòu)等單位開展環(huán)網(wǎng)柜的典型結(jié)構(gòu)方案、一次接口等標(biāo)準(zhǔn)化設(shè)計工作,
國家電網(wǎng)有限公司為積極響應(yīng)國家號召,制訂“碳達(dá)峰、碳中和”重點工作安排,
全面推動電網(wǎng)節(jié)能減排。為減低SF6氣體用量,深入推動電網(wǎng)綠色低碳發(fā)展,本
次面向環(huán)保氣體絕緣環(huán)網(wǎng)柜、固體絕緣環(huán)網(wǎng)柜、常壓密封空氣絕緣環(huán)網(wǎng)柜等環(huán)保
型產(chǎn)品開展標(biāo)準(zhǔn)化設(shè)計,便于產(chǎn)品在運行過程中發(fā)生故障或抽檢發(fā)現(xiàn)某企業(yè)產(chǎn)品
存在質(zhì)量問題時,可通過戶內(nèi)單柜或戶外環(huán)網(wǎng)箱整體起吊方便直接更換其它廠家
設(shè)備,各制造企業(yè)產(chǎn)品的內(nèi)部結(jié)構(gòu)可差異化設(shè)計。
10千伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
修編說明
10kV環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案延續(xù)了原2020版方案中一次接口、二次
接口及關(guān)鍵元器件等要求,主要在以下方面進行了深化完善。
一是設(shè)備選型方面,方案中刪去了SF6氣體絕緣環(huán)網(wǎng)柜的相關(guān)內(nèi)容。
二是典型結(jié)構(gòu)方案方面,刪去了負(fù)荷開關(guān)柜、負(fù)荷開關(guān)-熔斷器組合電器柜
的相關(guān)內(nèi)容,環(huán)網(wǎng)箱、預(yù)裝式變電站中環(huán)網(wǎng)柜的組合方案均采用斷路器間隔。
三是絕緣介質(zhì)方面,環(huán)保氣體絕緣環(huán)網(wǎng)柜中絕緣氣體可采用自然氣體(如氮
氣、干燥空氣等,禁止充入微量SF6氣體)、合成氣體(如C4、C5及其混合氣
體等)。
四是三工位開關(guān)描述及布置方案方面,三工位開關(guān)均采用母線側(cè)布置方案,
并將其描述改為母線側(cè)組合功能接地開關(guān)。
五是母線側(cè)組合功能接地開關(guān)的聯(lián)閉鎖方面,當(dāng)組合功能接地開關(guān)在母線側(cè),
由斷路器合閘實現(xiàn)電纜側(cè)接地的功能時,應(yīng)具有防止斷路器手動和電動分閘的機
械閉鎖和電氣閉鎖功能。
六是環(huán)網(wǎng)柜、環(huán)網(wǎng)箱殼體厚度方面,厚度要求改為公稱厚度2mm及以上,
并完善了引用標(biāo)準(zhǔn)和相關(guān)要求。
七是額定參數(shù)方面,給出了環(huán)網(wǎng)柜、環(huán)網(wǎng)箱的主要參數(shù)。
八是試驗細(xì)則方面,刪去了SF6氣體絕緣環(huán)網(wǎng)柜的型式試驗內(nèi)容。
2
10「伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
1概述
本次10kV環(huán)網(wǎng)柜標(biāo)準(zhǔn)化設(shè)計面向環(huán)保氣體絕緣環(huán)網(wǎng)柜、固體絕緣環(huán)網(wǎng)柜、
常壓密封空氣絕緣環(huán)網(wǎng)柜。
1.1額定參數(shù)
(1)額定電壓
額定電壓為12kV。
(2)額定電流
主母線額定電流為630A、分支母線額定電流為630A。
(3)額定絕緣水平
主回路的工頻耐受電壓:相間及對地為42kV、隔離斷口為48kV;雷電沖
擊耐受電壓:相問及對地為75kV、隔離斷口為85kV。
輔助回路工頻耐受電壓為2kV.
(4)額定短時耐受電流、額定峰值耐受電流和持續(xù)時間
額定短時耐受電流為20kA.額定峰值耐受電流為額定短時耐受電流的2.5
倍,接地回路電流值的最大值為主回路的87%。
主回路額定短路持續(xù)時間為3s,接地回路的持續(xù)時間為2s。
(5)內(nèi)部電弧故障等級、電流及時間
環(huán)網(wǎng)柜內(nèi)部電弧故障等級為IAC級AFLR,環(huán)網(wǎng)箱內(nèi)部電弧故障等級為
IAC-AB級AFLR和BFLR。
內(nèi)部電弧故障的試驗電流為20kA,短路電流持續(xù)時間大于等于0.5s,壓力
釋放通道方向朝向電纜溝。
(6)防護等級
環(huán)網(wǎng)柜外殼防護等級應(yīng)達(dá)到IP4X及以上,隔室之間的防護等級達(dá)到IP2X
及以上。環(huán)網(wǎng)箱外殼防護等級應(yīng)達(dá)到IP43及以上。
1.2使用條件
按DL/T593中第2章的規(guī)定。
1.3設(shè)備選型
10kV環(huán)網(wǎng)柜分為單元柜、共箱型方案。戶內(nèi)安裝宜選用單元柜方案,戶外
3
10千伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
環(huán)網(wǎng)箱或預(yù)裝式變電站內(nèi)可選用共箱型或單元柜方案。
1.4絕緣介質(zhì)
環(huán)保氣體絕緣環(huán)網(wǎng)柜中絕緣氣體可采用自然氣體(如氮氣、干燥空氣等,
禁止充入微量SF6氣體)、合成氣體(如C4、C5及其混合氣體等)。
4
10「伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
210kV環(huán)保氣體絕緣環(huán)網(wǎng)柜
2.1標(biāo)準(zhǔn)化原則
10kV環(huán)保氣體絕緣環(huán)網(wǎng)柜標(biāo)準(zhǔn)化設(shè)計依據(jù)以下原則:
(1)對于單元柜型式的環(huán)保氣體絕緣環(huán)網(wǎng)柜,針疝同一結(jié)構(gòu)方案,統(tǒng)一環(huán)
網(wǎng)柜外形尺寸、擴展母線位置及連接型式、地腳尺寸等,滿足章節(jié)2.3.1~2.3.28
的要求,滿足不同廠家設(shè)備通用互換。
(2)對于共箱型的環(huán)保氣體絕緣環(huán)網(wǎng)柜,針對同一結(jié)構(gòu)方案,統(tǒng)一環(huán)網(wǎng)柜
部分接口參數(shù)(除柜寬)及環(huán)網(wǎng)箱的外形尺寸、地腳尺寸等,滿足章節(jié)2.3.廣
2.3.28的要求。滿足環(huán)網(wǎng)箱及內(nèi)部柜體整體更換。
2.2典型結(jié)構(gòu)方案
環(huán)保氣體絕緣環(huán)網(wǎng)柜含單元柜方案和共箱型方案,其中單元柜共計3類典
型方案,包括電纜連接柜、PT柜、斷路器柜,如表27所示。除此之外,其余
原理圖方案不再作為典型方案推薦使用。
2.2.1單元柜方案
(1)方案1:電纜連接單元柜
(2)方案2:PT單元柜
(3)方案3:斷路器單元柜:采用母線側(cè)組合功能接地開關(guān)設(shè)計方案
2.2.2共箱型方案
共箱型組合方式規(guī)定為以下幾種方案。除此之外,其余結(jié)構(gòu)方案不再推薦
使用。其中斷路器間隔英文縮寫為V。一次接線圖見表2-3。
(1)兩單元排列方式包括:VV;
(2)三單元排列方式包括:VVV;
(3)四單元排列方式:VVVVo
2.2.3環(huán)網(wǎng)箱中環(huán)網(wǎng)柜組合方案
環(huán)網(wǎng)箱包含4路和6路全斷路器組合方案,其中進線斷路器的綜保裝置可
根據(jù)實際應(yīng)用需求選配,且環(huán)網(wǎng)箱內(nèi)應(yīng)包含DTU柜、PT柜??赏ㄟ^共箱型或
單元柜環(huán)網(wǎng)柜組合成以下方案:
(1)4路斷路器方案(VVVV);
5
10「伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
(2)6路斷路器方案(VVVVVV)o
2.2.4預(yù)裝式變電站中環(huán)網(wǎng)柜組合方案
預(yù)裝式變電站中環(huán)網(wǎng)柜僅包含2路和3路方案??赏ㄟ^共箱型或單元柜環(huán)
網(wǎng)柜組合成以下方案:
(1)2路共箱型方案:VV;
(2)3路共箱型方案:VVVo
6
10『伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方某(2023版)
也"I1XV環(huán)保氣體維絆環(huán)網(wǎng)柜一次方案圖匯叁龍(以元柜)
方案號
方案名稱電纜連接單元柜帶隔離開關(guān)PT柜斷路器通元和
h
7-\
4-
一次接線圖
-
廠
-「_
Iut-
I-xAC
歹
萬.
QF
工-H
H
.v
l&F伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
表22inkV環(huán)保氣體絕蜂環(huán)網(wǎng)柜一次方案圖匯購表(龍箱型)
方案號123
2路斷路滯3路斷路器路斷路器
方案名稱4
(W)(VW)(VVW)
11n11n1力一JL一1一1
1ninn
一次凄線圖.1
0(A。G(xj><Jh((1><Xjx?4>〈>■04><x>4>(>-0
「-[「一]「17mn-iC工■'i「「r-i
力?"1.T「d
ALd
工[衛(wèi)工1年“?m”?主工工華工
10「?伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
2.3一次接口及土建接口
2.3.1柜寬
PT單元柜寬為600mm.其他方案單元柜寬均為420mm。
共箱柜寬度不作要求。
2.3.2柜深
定義底框架深度。
各類功能單元柜深為850mm。最大外形(投影距離)W950mm。
2.3.3柜高
定義前框架高度。
柜前看,側(cè)擴柜體高度(不含儀表箱)為1650mm,其中儀表箱高度為350mm,
如圖2-1所示。
圖2T側(cè)擴柜體外形尺寸圖
柜前看,頂擴柜體高度(不含儀表箱)為1600mm,其中儀表箱高度為350mm
10千伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
目上出線高度不應(yīng)高于儀表箱,如圖2-2所示。
圖2-2《頂擴柜體外形尺寸圖
2.3.4儀表箱
儀表箱高度為350mm,PT柜方案寬度為600mm,其余方案寬度為420mm,
深度(不含門)2280mm。
2.3.5主開關(guān)滅弧方式
斷路器采用真空滅弧。
2.3.6殼體(氣箱)材質(zhì)
殼體(氣箱)材質(zhì)的防腐蝕性能不應(yīng)低于304不銹鋼。
2.3.7殼體(氣箱)材質(zhì)厚度
殼體(氣箱)材質(zhì)公稱厚度2mm及以上,尺寸允許偏差滿足GB/T3280-2015
中的B級精度(公稱寬度為1250?2100mm)。
2.3.8柜體框架材質(zhì)
柜體框架材質(zhì)采用敷鋁鋅板(鍍鋅層厚度達(dá)到AZ150及以上,可按照GB/T
1()千伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
2518-2019的要求)或鍍鋅鋼板(牌號為:DX51D+Z275,可按照GB/T2518-2019
的要求)。
2.3.9柜體材質(zhì)厚度
板材框架材質(zhì)公稱厚度2mm及以上,尺寸允許偏差滿足GB/T708-2019中
的B級精度要求(公稱寬度為12001500mm)。
2.3.10門板材質(zhì)
門板材質(zhì)為冷軋鋼板或敷鋁鋅板,表面進行噴涂,并滿足附著力要求.
2.3.11門板材質(zhì)厚度
儀表室、機構(gòu)室、電纜室門板材質(zhì)公稱厚度2mm及以上,電纜室門無觀察
窗,尺寸允許偏差滿足GB/T708-2019中的B級精度要求(公稱寬度為
12001500mm)。
2.3.12柜體防護等級
柜體外殼防護等級為IP4X,柜內(nèi)隔室間不小于IP2X。
2.3.13主母線擴展方式
主母線擴展方式可采用頂擴或側(cè)擴方式。狀展母線的設(shè)計安裝應(yīng)抵消環(huán)網(wǎng)
柜本體現(xiàn)場安裝后形成的相關(guān)累枳誤差,滿足運行可靠性的要求,如采用彈簧
觸指或具有適度柔性的擴展母線等。
2.3.14可接最多一次電纜數(shù)(每相)
每相最多可接一次電纜1根。
2.3.15一次電纜接線高度
一次電纜接線高度2650mm”
2.3.16一次電纜排列方式
一次電纜排列方式為水平一字型。柜前看,從左至右依次為A、B、C相,
并應(yīng)有相位標(biāo)識,且標(biāo)識應(yīng)不易氧化脫落。
2.3.17一次電纜固定位置
一次電纜固定位置應(yīng)設(shè)置在電纜隔室內(nèi)。柜內(nèi)電纜應(yīng)兩點固定,其中電纜
室入口處應(yīng)設(shè)置固定點。如圖2-3所示。
10「伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
圖2-3一次電纜固定示意圖
2.3.18一次電纜孔直徑
一次電纜孔直徑為6110mm或4>150mm(根據(jù)電纜尺寸選擇)。
2.3.19一次電纜孔位置
電纜孔中心與B相套管對齊,并確保電纜垂直。
2.3.20一次接地排規(guī)格
一次接地排規(guī)格為矩形銅排TMY-30mmX8mm,一次接地排搭接孔開孔尺
寸為2-9X15mm,并柜一次接地搭接排孔距100mm,如圖2-4所示。
圖2-4接地排開孔位置示意圖
2.3.21一次接地排貫穿孔
~次接地排貫穿孔尺寸為長方孔12mmx40mm,孔中心距前框架75mm,
距底框架54mm,如圖2?5所示。
12
10「?伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
2.3.22儀表箱二次走線孔
儀表箱二次過線孔采用橫向長圓孔,尺寸為50mmX120mm長圓孔。中心
位置距前框架100mm,距儀表箱頂面300mm。如圖2-C所示。
L領(lǐng)陽宅J,
.ur,
I
n
■
圖2-6儀表箱二次走線孔示意圖
2.3.23地腳開孔位置
單元柜地腳位置從底框架看,且不包含柜門的尺寸為:
M1-50mm;M2~150mm。
Ll=L2=20mm,
地腳開孔尺寸為4-013mm。如圖2-7所示。
10「?伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
圖2-7地腳開孔示意圖
2.3.24壓力釋放通道方向
壓力釋放通道方向朝向電纜溝。
2.3.25基礎(chǔ)槽鋼
基礎(chǔ)槽鋼為10#熱鍍鋅槽鋼,扣放,基礎(chǔ)按柜深750mm設(shè)計,深度方向間
距750mm(槽鋼外檐)。槽鋼固定孔為M12螺紋孔。柜體框架與前槽鋼對齊。
2.3.26標(biāo)準(zhǔn)化設(shè)計尺寸
定于戶內(nèi)安裝的單柜環(huán)網(wǎng)柜,應(yīng)滿足不同廠家產(chǎn)品訶的通用互換,為此,
補充設(shè)計如下標(biāo)準(zhǔn)化設(shè)計尺寸。
2.3.26.1側(cè)擴方式
(1)主母線側(cè)擴位置、規(guī)格及連接器
①側(cè)擴母線中心距地高度為1550mm,母線中心距為150nlin,B相中心
距前底框架510mm。
②母線側(cè)擴方式采用的母線插座及連接器尺寸如圖2-8、2-9.2To所示,
以并柜后兩母線插座底平面相距32mm為例。其中,為滿足不同柜體
并柜需要,未添加括號的尺寸為強制尺寸,添加括號的尺寸可供參考,
且可根據(jù)產(chǎn)品內(nèi)部絕緣、產(chǎn)品特點等對外形進行差異化設(shè)計。
14
10千伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
圖2-8母線插座尺寸示意圖
10千伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
圖2T母線連接器尺寸示意圖
圖2To母線插座與連接器井柜尺寸示意圖
(2)并柜方式
①氣箱上部并柜導(dǎo)向孔中心距側(cè)擴套管中心距高度11O±O.5mm,孔在A、
C相的正上方,尺寸2-①12nlln。
②氣箱并柜孔B相正上方一個,A、C導(dǎo)向孔外側(cè)50mm各一個,高度
和導(dǎo)向孔一致,尺寸3-①10mm。氣箱并柜螺栓M8x60mm。
③框架并柜孔中最底部靠近電纜室門孔尺寸距前框架65mm,距地
lOOmnio向后間距285mm一個,距前框架65mm的孔向上每隔300mm
間距一個,尺寸6-D10mm??蚣懿⒐窨妆匦柰瑫r連接3個以上,框
架并柜螺栓M8xl6mmo
如圖2-11所示。
10「?伏環(huán)網(wǎng)柜(箱)標(biāo)準(zhǔn)化設(shè)計方案(2023版)
圖2T1側(cè)擴并柜尺寸圖
2.3.26.2頂擴方式
(1)主母線頂擴位置、規(guī)格及連接器
①頂擴母線套管端面距地高度1728mm;母線中心距150mln;B相中心
距前底框架510門m;針對PT柜方案,頂擴母線套管中心距柜體右側(cè)
250mm,其余方案距柜體左側(cè)160mm(柜前看)。
②頂出套管采用C型套管。
(2)并柜方式
①氣箱并柜孔中心柜離套管頂部108mm,位于A、B、C相的中心線上,
尺寸為3-①10mm。氣箱井柜螺栓M8x60mmo
②框架并柜孔中最底部靠近電纜室門孔尺寸距前框架65mm,距地
100mm。向后間距285mm另外布置一個,距前框架65mm的孔向上
每間隔300mm布置一個,向上最后一個并柜孔間距不足300mm,調(diào)
整為270mm,尺寸6-610mm。框架并柜孔必需同時連接3個以上,
框架并柜螺栓M
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 賣場承包經(jīng)營合同
- 企業(yè)公司房屋租賃合同
- 公廁給排水施工方案
- bef增光膜施工方案
- 實驗室咨詢服務(wù)合同
- TACCEM 135-2024 雙組份聚氨酯導(dǎo)熱結(jié)構(gòu)膠
- 與石油管道交叉施工方案
- 建筑工程機械租賃合同范文
- 昌河中學(xué)高一數(shù)學(xué)試卷
- 水泥樓梯改造施工方案
- 制藥工程GMP(設(shè)備驗證)
- 亞洲的人文環(huán)境
- 初中物理之魔術(shù)物理課件
- 投用前安全檢查表
- “三備兩研”集體備課實施方案
- 醫(yī)療質(zhì)量管理制度相關(guān)知識考試試題
- 醫(yī)院病歷體格檢查表范本
- 二次供水設(shè)備保養(yǎng)維修方案(完整)
- 【直播帶貨的模式研究國內(nèi)外文獻綜述4300字(論文)】
- 高中英語-40篇英語短文搞定高中英語3500個單詞
- 2023年新改版蘇教版五年級下冊科學(xué)全冊精編知識點(附問答題總結(jié))
評論
0/150
提交評論