![鐵路施組】軌道交通一期工程臨電施工組織設(shè)計(jì)_第1頁(yè)](http://file1.renrendoc.com/fileroot_temp2/2021-2/26/9d4a83d4-0481-43dc-a485-39c925d7be03/9d4a83d4-0481-43dc-a485-39c925d7be031.gif)
![鐵路施組】軌道交通一期工程臨電施工組織設(shè)計(jì)_第2頁(yè)](http://file1.renrendoc.com/fileroot_temp2/2021-2/26/9d4a83d4-0481-43dc-a485-39c925d7be03/9d4a83d4-0481-43dc-a485-39c925d7be032.gif)
![鐵路施組】軌道交通一期工程臨電施工組織設(shè)計(jì)_第3頁(yè)](http://file1.renrendoc.com/fileroot_temp2/2021-2/26/9d4a83d4-0481-43dc-a485-39c925d7be03/9d4a83d4-0481-43dc-a485-39c925d7be033.gif)
![鐵路施組】軌道交通一期工程臨電施工組織設(shè)計(jì)_第4頁(yè)](http://file1.renrendoc.com/fileroot_temp2/2021-2/26/9d4a83d4-0481-43dc-a485-39c925d7be03/9d4a83d4-0481-43dc-a485-39c925d7be034.gif)
![鐵路施組】軌道交通一期工程臨電施工組織設(shè)計(jì)_第5頁(yè)](http://file1.renrendoc.com/fileroot_temp2/2021-2/26/9d4a83d4-0481-43dc-a485-39c925d7be03/9d4a83d4-0481-43dc-a485-39c925d7be035.gif)
版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
1、臨電施工組織設(shè)計(jì)方案XX軌道交通XX線一期工程XX標(biāo)段土建施工項(xiàng)目臨電施工組織設(shè)計(jì)方案中國(guó)交通建設(shè)CHINA COMMUNICATIONS INSTRUCTION編希H復(fù)核審核XX土建施工XX標(biāo)項(xiàng)目部二零XX年XX月目錄一、編制說(shuō)明 - 3 -二、工程概況 - 3 -三、臨電設(shè)計(jì)思路 - 3 -四、負(fù)荷計(jì)算 - 4 -五、配電線路的導(dǎo)線及導(dǎo)線截面選擇 - 19 -六、配電箱、開(kāi)關(guān)電器的選擇與接線 - 24 -七、接地和接地裝置設(shè)計(jì) - 28 -八、防雷設(shè)計(jì) - 28 -九、用電安全技術(shù)措施和電氣防火安全技術(shù)措施 - 29 -十、質(zhì)量標(biāo)準(zhǔn)、隱檢與驗(yàn)收 - 32 -十一、質(zhì)量保證措施 - 33 -
2、十二、文明施工及環(huán)保保證措施 - 35 -十三、施工風(fēng)險(xiǎn)分析及預(yù)案 - 35 -十四、電氣設(shè)計(jì)施工圖 - 36 - 3 -盾構(gòu)施工臨時(shí)用電組織設(shè)計(jì)一、編制說(shuō)明根據(jù)JGJ46-2005施工現(xiàn)場(chǎng)臨時(shí)用電安全技術(shù)規(guī)范 的規(guī)定:臨時(shí)用電設(shè)備 在5臺(tái)以上或設(shè)備總?cè)萘吭?0kW以上者,應(yīng)編制臨時(shí)用電施工組織設(shè)計(jì)。編制 臨時(shí)用電施工組織設(shè)計(jì)的目的在于使施工現(xiàn)場(chǎng)臨時(shí)用電工程有一個(gè)可遵循的科 學(xué)依據(jù),從而保障其運(yùn)行的安全可靠性; 另一方面: 臨時(shí)用電施工組織設(shè)計(jì)作為 臨時(shí)用電工程的主要技術(shù)資料, 有助于加強(qiáng)臨時(shí)用電工程的技術(shù)管理, 從而保障 其使用的安全和可靠性。臨時(shí)用電施工組織設(shè)計(jì)的任務(wù)是為現(xiàn)場(chǎng)施工設(shè)計(jì)一個(gè)完
3、備的臨時(shí)用電工程, 制定一套安全用電技術(shù)措施和防火措施,同時(shí)還要兼顧用電方便和經(jīng)濟(jì)。二、工程概況廣州市軌道交通十四線一期工程施工 1 標(biāo)段土建施工項(xiàng)目的范圍包括一個(gè)車 站和一個(gè)區(qū)間(兩條隧道) :江浦站、鄧村站 - 江浦站區(qū)間的土建工程。鄧村站 - 江浦站區(qū)間包括盾構(gòu)始發(fā)段和盾構(gòu)隧道段, 車站明挖段長(zhǎng)約 541 米,盾構(gòu)隧道段 1987米,總長(zhǎng)度約 2528 米。三、臨電設(shè)計(jì)思路1總體設(shè)計(jì):按照承包合同要求,業(yè)主提供 10kV的獨(dú)立電源到地鐵工地的 盾構(gòu)區(qū)間施工方指定供電點(diǎn)。供電負(fù)荷 6260kVA其中5000kVA將分別直接供兩 臺(tái)盾構(gòu)機(jī)用電,1260kVA經(jīng)兩個(gè)箱變變壓器降壓供盾構(gòu)施工場(chǎng)地
4、臨時(shí)設(shè)施用電。1-1)站內(nèi)設(shè)臨時(shí)開(kāi)閉站,兩臺(tái)盾構(gòu)機(jī)的供電電源由現(xiàn)場(chǎng)臨時(shí)開(kāi)閉站接入。1-2)盾構(gòu)施工現(xiàn)場(chǎng)應(yīng)由業(yè)主配設(shè)采用兩臺(tái)(630kVA+630kVA)中性點(diǎn)接地的箱 式變電站,經(jīng) 10kV/0.4kV 變壓后,供工地地面和隧道的施工使用。1-3)根據(jù)地鐵施工特殊性,用電設(shè)備采用集中分配的方式。1-4)現(xiàn)場(chǎng)擬配置200kW柴油發(fā)電機(jī)一臺(tái),作為工地停電時(shí)的備用電源,滿 足排水系統(tǒng)、防洪系統(tǒng)、緊急照明系統(tǒng)、宿舍辦公系統(tǒng)等停電時(shí)能正常工作,吊 臨電施工組織設(shè)計(jì)方案運(yùn)設(shè)備能夠及時(shí)恢復(fù)到安全狀態(tài)。2根據(jù)施工現(xiàn)場(chǎng)臨時(shí)用電安全技術(shù)規(guī)范規(guī)定,采用TN-S系統(tǒng);設(shè)置總配電箱和分配電箱,實(shí)行“三級(jí)配電、兩級(jí)保護(hù)”
5、。3根據(jù)施工現(xiàn)場(chǎng)設(shè)備的用電情況、臨時(shí)電源的位置及用電設(shè)備的分布和現(xiàn)場(chǎng)的環(huán)境條件等,確定總配電箱、電纜中間轉(zhuǎn)接箱,分配電箱的位置及線路走向, 見(jiàn)附施工現(xiàn)場(chǎng)供電平面布置圖。四、負(fù)荷計(jì)算1用電設(shè)備設(shè)備容量(Pe)的確定用電設(shè)備銘牌上都標(biāo)明有額定功率,但由于各自的額定工作條件不同,有的 可直接相加,但有的在計(jì)算中不能簡(jiǎn)單的把銘牌上規(guī)定的額定功率直接相加,必須把額定功率換算到統(tǒng)一規(guī)定的工作制下的功率后才能相加。為了便于統(tǒng)一說(shuō)明問(wèn)題,每臺(tái)用電設(shè)備的銘牌額定功率和容量分別用Pe和Se表示,經(jīng)換算后的設(shè)備容量分別用Pe和Se表示。(1)長(zhǎng)期連續(xù)工作制:指在規(guī)定環(huán)境溫度下連續(xù)運(yùn)行,設(shè)備任何部分的溫度 和溫升均不
6、超過(guò)允許值。根據(jù)建筑施工臨時(shí)用電組織設(shè)計(jì)及標(biāo)準(zhǔn)電箱中的規(guī)定,這類設(shè)備的設(shè)備容量Pe等于其銘牌額定功率Pe( kW。本項(xiàng)目長(zhǎng)期工作制的用電設(shè)備如表 1-1所示:表1-1本項(xiàng)目長(zhǎng)期工作制的用電設(shè)備容量和銘牌功率一覽表編號(hào)用電設(shè)備名稱設(shè)備容量Pe( kW)銘牌額定功率Pe( kW)1隧道通風(fēng)機(jī)1# (左線)1101102隧道通風(fēng)機(jī)2# (右線)1101103施工循環(huán)水泵1# (左線)55554施工循環(huán)水泵 2# (右線)55555循環(huán)水泵散熱泵1# (左線)7.57.56循環(huán)水泵散熱泵2# (右線)7.57.57充電機(jī)和烝餾水器1001008材料倉(cāng)、機(jī)電倉(cāng)風(fēng)扇10109拖泵13213210隧道臨時(shí)用
7、電404011污水處理站202012膨潤(rùn)土池?cái)嚢?513膨潤(rùn)土輸送泵303014砂漿儲(chǔ)料罐攪拌7.57.515盾構(gòu)機(jī)2500 X 25000(2)反復(fù)短時(shí)工作制:指設(shè)備以斷續(xù)方式反復(fù)進(jìn)行工作,工作時(shí)間與停歇時(shí) 間相互交替重復(fù)。根據(jù)建筑施工臨時(shí)用電組織設(shè)計(jì)及標(biāo)準(zhǔn)電箱中,這些用電 設(shè)備的設(shè)備容量Pe是指設(shè)備在某一暫載率下的銘牌功率統(tǒng)一換算到暫載率JC=25%下的功率。Pe= PeJC JC25 = 2 Pe /JC式中:Pe換算到JC= 25%時(shí)電動(dòng)機(jī)或設(shè)備的設(shè)備容量(kWJC電動(dòng)機(jī)或設(shè)備的暫載率()Pe電動(dòng)機(jī)或設(shè)備的銘牌額定功率(kW)本項(xiàng)目反復(fù)短時(shí)工作制用電設(shè)備的容量和額定功率如表 1-2所示
8、: 表1-2本項(xiàng)目反復(fù)短時(shí)工作制用電設(shè)備的容量和銘牌額定功率一覽表編號(hào)用電設(shè)備名稱設(shè)備容量Pe( kW)暫載率JC(%)銘牌額定功率Pe(kW11#龍門吊(45T左 線)1404011022#龍門吊(45T右 線)1404011033#龍門吊(16t )69.540554攪拌站88.540705鋼筋加工區(qū)1525156換刀電加熱爐3025307鉆床0.47100.75砂輪機(jī)0.16100.25切割機(jī)1.39102.2鉸絲機(jī)0.70101.18井口排水泵22255.5 X 4= 229井口防洪泵372518.5 X 2= 3710隧道內(nèi)水泵22255.5 X 4= 22(3)電焊機(jī)的設(shè)備容量根據(jù)
9、建筑施工臨時(shí)用電組織設(shè)計(jì)及標(biāo)準(zhǔn)電箱標(biāo)準(zhǔn),交流電焊機(jī)和直流電Pe=seC0= Se . JC CO焊機(jī)的設(shè)備容量是指統(tǒng)一換算到 JC=100%( JC1O0時(shí)的額定功率,即交流電焊機(jī)Pe= P e . =Pe . JC 直流電焊機(jī)JC100上兩式中:Pe換算到JC=1003電焊機(jī)的設(shè)備容量(kWSe交流電焊機(jī)或交流電焊裝置的銘牌額定視在功率(kVA)Pe直流電焊機(jī)的銘牌額定功率(kWJC與Se或Pe相對(duì)應(yīng)的電焊機(jī)銘牌額定暫載率()CO交流電焊機(jī)或交流電焊裝置在 Se時(shí)的額定功率因數(shù)本項(xiàng)目所用的電焊機(jī)的設(shè)備容量和銘牌額定視在功率或額定功率如表1-3所示:表1-3電焊機(jī)的設(shè)備容量和銘牌額定視在功率或
10、額定功率一覽表:編號(hào)電焊機(jī)或電焊 裝置名稱設(shè)備容量Pe ( kWCO暫載率(%)額定視在功率(kVA)1機(jī)修間交流電焊裝置50.240.810031.4*22其它小型交流電焊機(jī)38.880.810024.3*23隧道用交流電焊機(jī)9.470.83510*2(4) 照明設(shè)備的設(shè)備容量:根據(jù)建筑施工臨時(shí)用電組織設(shè)計(jì)及標(biāo)準(zhǔn)電箱標(biāo)準(zhǔn),因現(xiàn)場(chǎng)燈可能有金屬 鹵化物燈、高壓水銀燈或碘鎢燈、白熾燈,加之所有的日光燈都是用電子鎮(zhèn)流器, 為簡(jiǎn)單起見(jiàn),全部按 Pe=1.1 P e計(jì)算。本項(xiàng)目的照明燈容量及額定功率如表 1-4所示:表1-4照明燈容量及額定功率一覽表編號(hào)照明燈位置照明燈容量Fe (kw)照明燈額定功率
11、Pe,( kw)1場(chǎng)區(qū)照明27. 5252隧道照明(左線)16.5153隧道照明(右線)16.5154辦公區(qū)用電30.8285宿舍用電35.2326食堂用電30.8287井口照明3330(5) 不對(duì)稱負(fù)荷的設(shè)備容量在施工中,多臺(tái)單相設(shè)備應(yīng)均勻地分別接在三相上,當(dāng)單項(xiàng)用電設(shè)備的總?cè)?量不超過(guò)三相用電設(shè)備總?cè)萘康?15%時(shí),可近似按三相負(fù)荷平衡分配考慮,一 般來(lái)說(shuō)我們工地單項(xiàng)設(shè)備的總?cè)萘恐徽伎側(cè)萘康?0%左右,故表1 4算出的設(shè)備容量就可以當(dāng)作三相設(shè)備的總?cè)萘俊?、用電設(shè)備的計(jì)算負(fù)荷根據(jù)建筑施工臨時(shí)用電組織設(shè)計(jì)及標(biāo)準(zhǔn)電箱標(biāo)準(zhǔn),用電設(shè)備的設(shè)備容量 必須除以其運(yùn)行效率,即:P=Pe/n,式中P-單臺(tái)用
12、電設(shè)備的計(jì)算負(fù)荷(kW),n -設(shè)備運(yùn)行效率。為簡(jiǎn)單起見(jiàn),全部按耳=100%考慮,故表11至表1 4中的設(shè)備計(jì)算負(fù) 荷 P=Pe3、用電設(shè)備組的計(jì)算負(fù)荷的確定根據(jù)建筑施工臨時(shí)用電組織設(shè)計(jì)及標(biāo)準(zhǔn)電箱標(biāo)準(zhǔn),各用電設(shè)備應(yīng)按需要 系數(shù)Kx的不同系數(shù)值劃分若干個(gè)用電設(shè)備組,需要系數(shù)Kx定義為用電設(shè)備組的 計(jì)算負(fù)荷Pj2和用電設(shè)備組的各設(shè)備容量和刀Pe之比,即:Kx = Pj1/刀Pe 根據(jù)確定的需要系數(shù)Kx,各用電設(shè)備組的計(jì)算負(fù)荷可采用下面的公式計(jì)算Pj1=KxE PeQj1=Pj1tgSj仁Pj12 Qj12式中:Pj1 用電設(shè)備組的有功計(jì)算負(fù)荷(kWQj1 用電設(shè)備組的無(wú)功計(jì)算負(fù)荷(kVARSj1
13、用電設(shè)備組的視在計(jì)算負(fù)荷(kVA刀Pe用電設(shè)備組的各設(shè)備容量和(kWKx 用電設(shè)備組需要系數(shù)根據(jù)工地的具體情況,擬把用電設(shè)備組分成14組,除第13組和第14組為盾構(gòu)機(jī)外,讓其余12組設(shè)備計(jì)算負(fù)荷之和計(jì)算如下:如表1-5表1-5本項(xiàng)目14組用電設(shè)備計(jì)算負(fù)荷分配一覽表變壓器一級(jí)柜二級(jí)柜用電設(shè)備名稱計(jì)算負(fù)荷Pj1 (kw)刀 Pj2 (kw)一號(hào)變壓器配1#1-11#45T龍門吊(前45T門機(jī))1401901-2備用50電柜2#2-1隧道風(fēng)機(jī)(左線)110192.52-2施工循環(huán)水泵(左線)552-3循環(huán)水散熱泵(左線)7.52-4備用203#3-1換刀電加熱爐30130.483-2機(jī)修間80.48
14、3-3備用204#4-1隧道用電(左線)54.57162.144-2隧道用電(右線)54.574-3地面照明334-4備用205#5-1井口防洪泵(左線)18.5475-2井口防洪泵(右線)18.55-3備用106#6-1倉(cāng)庫(kù)用電10606-2鋼筋加工區(qū)156-3污水處理站206-4備用157#7-1辦公區(qū)用電30.8116.87-2宿舍用電35.27-3食堂用電30.87-4備用20二號(hào)變 壓器配 電柜8#8-12#45T龍門吊(后45T門機(jī))1402008-2備用609#9-1隧道風(fēng)機(jī)(右線)110202.59-2施工循環(huán)水泵(右線)559-3循環(huán)水散熱泵(右線)7.59-4備用3010#
15、10-1拖泵13222810-2砂漿儲(chǔ)料罐攪拌7.510-3攪拌站88.511#11-116T龍門吊(16T左右線)69.515511-2膨潤(rùn)土輸送泵3011-3膨潤(rùn)土池?cái)嚢?.511-4備用5012#12-1充電機(jī)和蒸餾水器(7個(gè))10015012-2備用50開(kāi)閉所一號(hào)柜13#13-1左線盾構(gòu)機(jī)25002500開(kāi)閉所二號(hào)柜14#14-1右線盾構(gòu)機(jī)25002500在表1-5中的計(jì)算負(fù)荷: 隧道用電(左線):Pj1=5.5*2 (井口排水泵)+5.5*2 (隧道內(nèi)水泵)+9.47 (隧 道內(nèi)交流電焊機(jī))+16.5 (隧道內(nèi)照明日光燈)+6.6 (井口照 明)=54.57kW(考慮到聯(lián)絡(luò)通道是在隧
16、道貫通之后才施工因 此不加此項(xiàng))隧道用電(右線):Pj仁5.5*2 (井口排水泵)+5.5*2 (隧道內(nèi)水泵)+9.47 (隧 道內(nèi)交流電焊機(jī))+16.5 (隧道內(nèi)照明日光燈)+6.6 (井口照 明)=54.57kW機(jī)修間:Pj1=50.24 (維修間電焊機(jī))+27.5 (場(chǎng)區(qū)照明)+2.74 (維修 間小型設(shè)備)=80.48kW4、配電干線(配電母線)負(fù)荷和供電變壓器、自備發(fā)電機(jī)容量計(jì)算:(1)配電干線和配電母線上的計(jì)算負(fù)荷根據(jù)建筑施工臨時(shí)用電組織設(shè)計(jì)及標(biāo)準(zhǔn)電箱 標(biāo)準(zhǔn)所述,每條配電干線(配 電母線)上接有不同的用電設(shè)備組,且一般來(lái)說(shuō)它們的運(yùn)行是不可能同步的,所 以配電干線(配電母線)上的計(jì)算
17、負(fù)荷 Pj3必然小于或等于各用電設(shè)備組計(jì)算負(fù)荷 之和,可以按式P3=K匹P2計(jì)算,式中:P J3-配電干線(配電母線)上的計(jì)算負(fù)荷(kW);KP-有功負(fù)荷同期系數(shù),一般取0.7-0.9,該支路只有一臺(tái)設(shè)備時(shí),取1;刀P2 各用電設(shè)備組計(jì)算負(fù)荷之和(kW);根據(jù)我們的實(shí)際情況,和以往施工經(jīng)驗(yàn)除盾構(gòu)機(jī)專線第13條和第14條取KP 為1,另外12條配電干線取KP為0.8,總配電母線取0.7,而2臺(tái)盾構(gòu)機(jī)總配電 母線取KP為0.9,故上述4條配電干線和總配電母線上的計(jì)算負(fù)荷值如表1-6所示:表1-6本項(xiàng)目配電干線和配電母線上的計(jì)算負(fù)荷配電干線號(hào)每組各設(shè)備計(jì)算負(fù)荷之和刀P2每條(kW)每組配電干線計(jì)算負(fù)
18、荷P3每組(kW)全部設(shè)備計(jì)算負(fù) 荷之和刀R2全部(kW)總配電母線計(jì) 算負(fù)荷P3z總母線(kW)1#190152719.2501.042#192.51543#130.48104.44#162.14129.75#4737.66#60487#116.893.58#200160749.4524.289#202.516210#228182.411#15512412#15012013#250025002500450014#250025002500(2)供電變壓器容量的選擇根據(jù)建筑施工臨時(shí)用電組織設(shè)計(jì)及標(biāo)準(zhǔn)電箱標(biāo)準(zhǔn),上述配電母線上的計(jì) 算負(fù)荷實(shí)際上就是施工現(xiàn)場(chǎng)臨時(shí)用電工程的用電總計(jì)算負(fù)荷或總用電容量,也
19、是選擇配電母線導(dǎo)線和總配電箱電器,以及供電變壓器容量的主要依據(jù)。根據(jù)總配電母線計(jì)算負(fù)荷 R3z總母線=Sj3z總母線CO ,參考建筑施工臨時(shí) 用電組織設(shè)計(jì)及標(biāo)準(zhǔn)電箱標(biāo)準(zhǔn),選CO為0.85,貝號(hào)變壓器S3Z總母線= 一號(hào) P3z 總母線/ CO= 501.04 /0.85 590.6kVA,二號(hào) Sj3z 總母線=二號(hào) P3z 總母線/ CO= 524.28 /0.85617.9kVA,故選用容量為630kVA的兩臺(tái)低損耗 變壓器,便能滿足要求。(3)自備發(fā)電機(jī)組額定容量選定施工現(xiàn)場(chǎng)需要保證用電的設(shè)備計(jì)算負(fù)荷如下:1)隧道照明:16.5*2=33kW2)晚上井口、場(chǎng)地照明、辦公室和食堂預(yù)留:50
20、kW3)兩臺(tái)防洪泵和排水泵:18.5*2+5.5*2=48kW4)臨時(shí)緊急用電預(yù)留:30kW5)45T龍門吊機(jī)和16T龍門吊機(jī):140kW(注:停電后先使各龍門吊恢復(fù)到安全 位置后關(guān)閉)刀 P=33+50+48+30=161kW由于兩條隧道為獨(dú)立變壓器供電,停電時(shí)需要用電設(shè)備沒(méi)有共同的電氣連 接,根據(jù)其他標(biāo)段施工的經(jīng)驗(yàn),停電次數(shù)很少,停電后盾構(gòu)機(jī)不再掘進(jìn),選用一 臺(tái)200kW的柴油發(fā)電機(jī)為需要用電設(shè)備供電。5、配電總線上的電流計(jì)算(即變壓器到低壓配電室)根據(jù)表1-6列出的有功計(jì)算負(fù)荷計(jì)算電流(COS =0.85則tg =0.62,以下相同)號(hào)配電房:Pj3=KxE Pe=501.04kWQj3
21、=Pj3tg =501.04 X 0.62=315.6kVARSj3= . 501.042 315.62=598kVAIj3=Sj3/ (、3 X Ue) =5989( 、3 X 0.38)A 910.0A 二號(hào)配電房:Pj3=KxE Pe=524.28kWQj3=Pj3tg =525.28 X 0.62=325.67kVARSj3= 524.282 325.672 =618.05kVAIj3=Sj3/( ,3 X Ue) =618.05/(、3 X 0.38)A 939.1A6、配電干線上的電流計(jì)算(即變壓器低壓配電室到第一分配箱)根據(jù)表1-6列出的有功計(jì)算負(fù)荷計(jì)算電流(COS =0.85則
22、tg =0.62,以下相同)第一組:Pj3=KxE Pe=152kWQj3=Pj3tg =152X 0.62=94.24kVARSj3= 1522 94.242 =178.84kVAIj3=Sj3/( 3 X Ue) =178.84/( . 3 X 0.38)A 271.8A第二組:Pj3=KxE Pe=154kWQj3=Pj3tg =154X 0.62=94.24kVARIj3=Sj3/( .3 X Ue) =178.84/( 、3 X 0.38)A 273.8A第三組:Pj3=KxE Pe=104.4kWQj3=Pj3tg =104.4 X 0.62=64.7kVARSj3= j04.42
23、 64.72 - 122.8kVAlj3=Sj3/ ( .,3 X Ue =122.8/( . 3 X 0.38)A 186.6A 第四組:Pj3=KxE Pe=129.7kWQj3=Pj3tg =129.7 X 0.62=80.4kVARSj3= J29.72 80.42 152.6kVAIj3=Sj3/( 3 X Ue) =152.6/(3 X 0.38)A 231.9A第五組:Pj3=KxE Pe=37.6kWQj3=Pj3tg =37.6 X 0.62=23.3KVARSj3= . 37.62 23.32 =44.2kVAIj3=Sj3/( 3 X Ue) =57.4/( . 3 X
24、0.38)A 67.2A第六組:Pj3=KxE Pe=48kWQj3=Pj3tg =48X 0.62=29.76KVARSj3= . 482 29.762 =56.5kVAIj3=Sj3/( .3 X Ue) =56.5/( . 3 X 0.38)A 85.8A第七組:Pj3=KxE Pe=93.5KWQj3=Pj3tg =93.5 X 0.62=57.9KVARSj3= . 93.52 57.92=109.9kVAIj3=Sj3/( .3 X Ue) =109.9/( .3 X 0.38)A 167A第八組:Pj3=KxE Pe=160kWQj3=Pj3tg =160X 0.62=100.4
25、kVARSj3= 1602 1 00.42 =19.58kVAlj3=Sj3/ ( . 3 X Ue =190.58/( . 3 X 0.38)A 288.6A第九組:Pj3=KxE Pe=162kWQj3=Pj3tg =162X 0.62=100.4KVARSj3= 1622 100.42 =190.6kVAIj3=Sj3/( ,3 X Ue) =190.6/( , 3 X 0.38)A 289.6A第十組:Pj3=KxE Pe=182.4kWQj3=Pj3tg =182.4 X 0.62=113.1kVARSj3= 182.42_113.12 =214.6kVAIj3=Sj3/( .3 X
26、 Ue) =214.6/(3 X 0.38)A 326.1A第十一組:Pj3=KxE Pe=124kWQj3=Pj3tg =124X 0.62=76.88kVARSj3= 22=145.9kVAJ V12476.88Ij3=Sj3/( 3 X Ue) =145.9/(3 X 0.38)A 221.7A第十二組:Pj3=KxE Pe=120kWQj3=Pj3tg =120X 0.62=74.4kVARSj3= M74.42 =141.1kVAIj3=Sj3/( 3 X Ue) =141.1/(3 X 0.38)A 214.4A7、根據(jù)表1-5,各支路負(fù)荷計(jì)算出各支路電流(即第一分配箱到第二分配箱
27、 的支路電流)(1) 1-1支路電流:(1#龍門吊45T)Pj仁 刀 Pe=140kWQj1= Pjltg =140X 0.62=86.26kVAR9n- ,Sj1= Pj!2 Qj!2 = 1402 86.262 - 163.71kVAIj1= Sj1/ ( 3 X Ue) =163.71/(3 X 0.38)A 249.02A(2) 2-1支路電流:(隧道風(fēng)機(jī)左線)Pj仁刀 Pe=110kWQj1= Pj1tg =110X 0.62=68.2kVARSj1= Pj12 Qj12=、1102 68.22 - 129.4kVAIJ仁SJ1/ ( .3 X Ue) =129.4/ ( , 3 X
28、 0.38 ) A 196.5A(3) 2-2備用電流:(施工循環(huán)水泵左線)Pj仁刀 Pe=55kWQj仁Pj1tg =55X 0.62=34.1kVARSj仁 Pj12 Qj12 =、552 34.12 kVAR=64.7kVAlj仁Sj1 /( 3 X Ue) =64.7 /( 3 X 0.38 ) A 98.3A(4) 2-3支路電流:(循環(huán)水散熱泵左線)Pj仁刀 Pe=7.5kWQj1= Pj1tg =7.5 X 0.62=4.6kVARSj1= Pj12 Qj12=、7.52 4.62 =8.8kVAIj1=Sj1/ ( 3 X Ue) =8.8/ ( : 3 X 0.38 ) A
29、13.4A(5) 3-1支路電流:(換刀電加熱爐)Pj仁刀 Pe =30kWQj1=Pj1tg =30X 0.62 18.6kVARSj仁 Pj12 Qj12=、302 18.62 35.3kVAIJ仁SJ1/ ( -.3 X Ue) =35.3/ ( . 3 X 0.38 ) A 53.6A(6) 3-2支路電流:(機(jī)修間)Pj仁刀 Pe= 80.48kWQj仁Pj1tg =80.48 X 0.62=49.9kVARSj1= .,80.842 49.92 =94.3kVAlj仁Sj1/ ( 3 X ue =94.3/ ( 3 X 0.38 ) A 143.3A(7) 4-1支路電流:(隧道左
30、線照明)Pj仁刀 Pe=54.57kWQj仁Pj1tg =54.57 X 0.62=33.8kVARSj仁=、54.572 33.82 kVAR=64.2kVAlj仁Sj1 /( 3 X Ue) =64.2 /(3 X 0.38 ) A 97.6A(8) 4-2支路電流:(隧道右線照明)Pj仁刀 Pe=54.57kWQj仁Pj1tg =54.57 X 0.62=33.8kVARSj1= Pj!2 Qj12=,54.572 33.82 kVAR=64.2kVAlj仁Sj1 /( 3 X Ue) =64.2 /( -.3 X 0.38 ) A 97.6A(9) 4-3支路電流:(井口照明)Pj仁刀
31、 Pe=33kWQj仁Pjltg =33X 0.62=20.46kVARSj仁 Pji2 0=.、332 20.462 =38.8kVAIj1=Sj1/ ( .3 X Ue) =38.8/ ( .3 X 0.38 ) A 58.9A(10) 5-1支路電流:(井口防洪泵左線)Pj1 =刀 Pe =18.5kWQj1= Pj1tg =18.5 X 0.62 11.47kVARSj1= Pj12 Qj12 =、18.52 11.472 21.8kVAIJ仁SJ1/ ( .3 X Ue) =21.8/ ( .3 X 0.38 ) A 33.1A(11) 5-2支路電流:(井口防洪泵右線)Pj1 =刀
32、 Pe =18.5kWQj1= Pj1tg =18.5 X 0.62 11.47kVARSj1= :Qj12 = 18.52 11.472 21.8kVAJ仁SJ1/ ( 3 x ue =21.8/ ( 3 x 0.38 ) 心 33.1A(12) 6-1支路電流:(倉(cāng)庫(kù)用電)Pj仁 刀 Pe=10kWQj1= Pjltg =15x 0.62=6.2kVARSj1= Pj!2 Qji2 =.102 6.22 =11.8kVAIj1=Sj1/ ( ,3 x Ue) =11.8/ ( ,3 x 0.38 ) A 17.9A(13) 6-2支路電流:(鋼筋加工區(qū))Pj仁 刀 Pe=15kWQj1=
33、Pj1tg =15x 0.62=9.3kVARSj1= Pj12 Qj12 =.152 9.32 =17.6kVAIj1=Sj1/ ( .3 x Ue) =17.6/ ( ,3 x 0.38 ) A 26.7A(14) 6-3支路電流:(污水處理站)Pj仁刀 Pe=20kWQj1=Pj1tg =20x 0.62=12.4kVARSj仁Qj12=、202 12.42 23.5kVAIJ仁SJ1/ ( 3 x Ue) =23.5/ ( ,3 x 0.38 ) A 35.7A(15) 7-1支路電流:(辦公區(qū)用電)Pj仁刀 Pe=30.8kWQj仁Pj1tg =30.8 x 0.62=19kVARS
34、j仁 Pj12 Qj12=、30.82 192 kVAR=36.2kVAlj仁Sj1 /( 3 x Ue) =36.2 /( 3 x 0.38 ) A 55A(16) 7-2支路電流:(宿舍用電)Pj仁刀 Pe=35.2kWQj1= Pj1tg =35.2 x 0.62=21.8kVARSj仁 Pj12 Qj12=、35.22 21.82 kVAR=41.4kVAlj仁Sj1 /( 3 x Ue) =41.4 /( 3 x 0.38 ) A 62.9A(17) 7-3支路電流:(食堂用電)Pj仁刀 Pe=30.8kWQj仁Pjltg =30.8 x 0.62=19kVARSj仁 時(shí) Qj/=
35、30.82 192 kVAR=36.2kVAlj仁Sj1 /( 3 x Ue) =36.2 /(3 x 0.38 ) A 55A(18) 8-1支路電流:(2#龍門吊45T)Pj仁 刀 Pe=140kWQj1= Pj1tg =140x 0.62=86.26kVARSj仁Qj12=1402 86.262 163.71kVAIj1= Sj1/ ( .3 x Ue) =163.71/(3 x 0.38)A 249.02A(19) 9-1支路電流:(隧道風(fēng)機(jī)右線)Pj仁刀 Pe=110kWQj1= Pj1tg =110x 0.62=68.2kVARSj仁 Pj12 Qj12 =.1102 68.22
36、kVAR=129.4kVAlj仁Sj1 /( 3 x Ue) =129.4 /( .3 x 0.38 ) A 196.6A(20) 9-2支路電流:(施工循環(huán)水泵右線)Pj仁刀 Pe=55kWQj仁Pj1tg =55x 0.62=34.1kVARSj1= Pj12 Qj12=、552 34.12 kVAR=64.7kVAlj仁Sj1 /( 3 x Ue) =64.7 /( 3 x 0.38 ) A 98.3A(21) 9-3支路電流:(循環(huán)水散熱泵右線)Pj仁刀 Pe=7.5kWQj1= Pj1tg =7.5 x 0.62=4.65kVARSj仁 Pj12 Qj12 =、7.52 4.652
37、kVAR=8.8kVAlj仁Sj1 /( 3 x Ue) =8.8 /( 3 x 0.38 ) A 13.4A(22) 10-1支路電流:(拖泵)Pj仁 刀 Pe=132kWQj1= Pjltg =132X 0.62=81.8kVARSj仁 PjQji2 = .1322 84.82 kVAR=188.3kVAlj仁Sj1 /( 3 X Ue) =155.3 /(3 X 0.38 ) A 235.9A(23) 10-2支路電流:(砂漿儲(chǔ)料罐攪拌)Pj仁刀 Pe=7.5kWQj1= Pj1tg =7.5 X 0.62=4.65kVARSj仁= 7.52 4.652 kVAR=8.8kVAlj仁Sj
38、1 /( 3 X Ue) =8.8 /( 3 X 0.38 ) A 13.4A(24) 10-3支路電流:(攪拌站)Pj仁刀 Pe=88.5kWQj1=Pj1tg =88.5 X 0.62=54.9kVARSj1=,88.52 54.92 kVAR=104kVAlj仁Sj1 /( 3 X Ue) =104/( 3 X 0.38 ) A 158A(25) 11-1支路電流:(16t龍門吊左右線)Pj仁刀 Pe=69.5kWQj1= Pj1tg =69.5 X 0.62=43.1kVARSj仁Qj12=、69.52 43.12 kVAR=81.7kVAlj仁Sj1 /( 3 X Ue) =81.7
39、 /(3 X 0.38 ) A 124.2A(26) 11-2支路電流:(膨潤(rùn)土輸送泵)Pj仁刀 Pe =30kWQj1=Pj1tg =30X 0.62 18.6kVARSj仁 Pj12 Qj12 = .、302 18.62 35.3kVAlj仁SJ1/ ( 3 X Ue) =35.3/ ( 3 X 0.38 ) A 53.6A(27) 11-3支路電流:(膨潤(rùn)土攪拌泵)Pj仁刀 Pe=5.5kWQj1= Pjltg =5.5 X 0.62=3.4.1kVARSj仁 PjQji2 = ,5.52 3.412 kVAR=6.5kVAIj1= Sj1 /( 3 X Ue) =6.5 /( 3 X
40、0.38 ) A 9.9A(28) 12-1支路電流:(充電機(jī)和蒸餾水器)Pj仁 刀 Pe=100kWQj1= Pj1tg =100X 0.62=62kVARSj仁= , 1002 622 kVAR=117.7kVAlj仁Sj1 /( 3 X Ue) =117.7 /( 3 X 0.38 ) A 178.9A五、配電線路的導(dǎo)線及導(dǎo)線截面選擇1、導(dǎo)線及導(dǎo)線截面的選擇原則:(1) 根據(jù)建筑施工臨時(shí)用電組織設(shè)計(jì)及標(biāo)準(zhǔn)電箱標(biāo)準(zhǔn),應(yīng)使所選導(dǎo)線長(zhǎng)期 連續(xù)負(fù)荷允許載流量Iy大于或等于其計(jì)算電流,即Iy Ij(2) 根據(jù)JGJ46-2005施工現(xiàn)場(chǎng)臨時(shí)用電安全技術(shù)規(guī)范中規(guī)定,導(dǎo)線截面 應(yīng)根據(jù)允許載流量和允許電
41、壓損失確定;但根據(jù)建筑施工臨時(shí)用電組織設(shè)計(jì)及 標(biāo)準(zhǔn)電箱,對(duì)電纜芯線標(biāo)稱截面不大于 50mm寸,電壓損失可以忽略不計(jì),70 mm 以上的電纜,XP=0.07Q/km;故只對(duì)標(biāo)稱截面50mA導(dǎo)線進(jìn)行電壓損失校核。(3) 根據(jù)建筑施工臨時(shí)用電組織設(shè)計(jì)及標(biāo)準(zhǔn)電箱,電纜在按規(guī)定保持水 平檔距和垂直固定點(diǎn)的情況下,電纜能承住自重帶來(lái)的荷重,所以在不附加外力 的情況下,可不作機(jī)械強(qiáng)度校驗(yàn)計(jì)算。(4) 根據(jù)JGJ46-2005施工現(xiàn)場(chǎng)臨時(shí)用電安全技術(shù)規(guī)范規(guī)定,必須采用TN-S接地、接零保護(hù)系統(tǒng),故必須采用五芯電纜;盾構(gòu)施工的現(xiàn)場(chǎng),因場(chǎng)地狹小,設(shè)備繁多,配電干線導(dǎo)線敷設(shè)一般采用電纜溝或沿墻明設(shè);根據(jù)以往的經(jīng)驗(yàn),
42、進(jìn)隧道的照明現(xiàn)改為耐熱聚氯乙烯絕緣銅芯導(dǎo)線,沿墻架絕緣子敷設(shè)。(5) 在敷設(shè)彎度半徑太小、臨時(shí)敷設(shè)、很短時(shí)間就要拆除的地方和移動(dòng)式配電箱和開(kāi)關(guān)箱,必須采用橡皮絕緣電纜;根據(jù)本施工現(xiàn)場(chǎng)場(chǎng)地的特點(diǎn),總電源箱至各分配電箱的導(dǎo)線采用能承受較大外力和通用的橡套軟電纜(YCW。2導(dǎo)線截面的選擇(1) 進(jìn)戶線:此段由電力部門負(fù)責(zé)安裝到場(chǎng)。(2) 配電總線導(dǎo)線選擇根據(jù)第1條的第(1)段的原則,現(xiàn)把表1-6配電干線的計(jì)算負(fù)荷及以上算出的計(jì)算電流、選擇的導(dǎo)線截面積、型號(hào)和敷設(shè)方式列入如表1-7 :表1-7配電總線導(dǎo)線選擇一覽表序 號(hào)干線計(jì)算 負(fù)荷Pj3每組(kw)干線計(jì)算電流lj(A)選擇的導(dǎo)線截面積(mrr)選
43、擇的導(dǎo)線型號(hào)敷設(shè)方式1502.04907.0185YCW*185 (11 根)溝道敷設(shè)2525.28939.1185YCW*185 (11 根)溝道敷設(shè)(3) 配電干線導(dǎo)線選擇根據(jù)第1條的第(1)段的原則,現(xiàn)把表1-6配電干線的計(jì)算負(fù)荷及以上算出的計(jì)算電流、選擇的導(dǎo)線截面積、型號(hào)和敷設(shè)方式列入如表1-8 :表1-8配電干線導(dǎo)線選擇一覽表序 號(hào)干線計(jì)算 負(fù)荷Pj3每組(kw)干線計(jì)算 電流Ij(A)選擇的導(dǎo) 線截面積(mrr)選擇的導(dǎo)線型號(hào)溝道敷設(shè)1152271.8120YCW0 120+2 X 70)0.6-1kV溝道敷設(shè)2154271.8120YCW(3 120+2 X 70)0.6-1kV
44、溝道敷設(shè)3104.4186.970YCW(X 70+2 X 35)0.6-1kV沿墻明設(shè)4129.7231.995YCW( 95+1 X 50) 0.6-1kV溝道敷設(shè)537.467.216YCW( 16+2 X 6) 0.6-1kV溝道敷設(shè)64885.825YCW(X 25+2 X 10) 0.6-1kV沿墻明設(shè)793.516750YCW(X 50+2 X 25) 0.6-1kV沿墻明設(shè)8160289.6120YCW(X 120+2 X 70) 0.6-1kV溝道敷設(shè)9162289.6120YCW(X 120+2 X 70) 0.6-1kV溝道敷設(shè)10182.4326.1120YCW(X 1
45、20+2 X 70) 0.6-1kV沿墻明設(shè)11124221.795YCW(X 95+2 X 50) 0.6-1kV沿墻明設(shè)12120214.495YCW(X 95+2 X 50) 0.6-1kV溝道敷設(shè)132500153.670YJV(3 X 70) 8.7/15kV綜合敷設(shè)142500153.670YJV(3 X 70) 8.7/15kV綜合敷設(shè)注意盾構(gòu)機(jī)高壓電纜敷設(shè)方法為:先沿圍擋,然后沿電纜溝穿施工便道到達(dá)始發(fā)井口,自然延伸到井下,再沿高壓電纜掛鉤達(dá)始發(fā)前盾構(gòu)機(jī)尾部臺(tái)車。(4) 配電支路導(dǎo)線選擇由表1-5中的各用電設(shè)備的計(jì)算負(fù)荷及以上的計(jì)算出的電流 ,把所選導(dǎo)線截 面、型號(hào)及敷設(shè)方式列
46、入表1-9 :各配電支路導(dǎo)線選擇一覽表。選擇的依據(jù)建 筑施工臨時(shí)用電組織設(shè)計(jì)及標(biāo)準(zhǔn)電箱中的通用橡套電纜載流量選擇。表1-9 各配電支路導(dǎo)線選擇一覽表序 號(hào)配電支路 名稱支路計(jì) 算 負(fù)荷R( kw)支路計(jì) 算電流I j1( A)選擇的 導(dǎo)線截 面(mrn)載流量(A)選擇的導(dǎo)線 型號(hào)規(guī)格敷設(shè)方 式1-11#龍門吊140249.0295260YCW/0.6-1kv 3 X2 295 + 2X 50電纜溝2-1隧道風(fēng)機(jī)(左線)110196.6570215YCW/0.6-1kv 3 X702 + 1X 352沿墻2-2施工循環(huán)水 泵(左線)5598.325113YCW/0.6-1kv 3 X2 225
47、 + 1X 10沿墻2-3循環(huán)水散熱 泵(左線)7.513.4436YCW/0.6-1kv 3 X42+ 1X 1.5 2沿墻3-1換刀電加熱 爐3053.61685YCW/0.6-1kv 3 X162+ 2X 62沿墻3-2機(jī)修間80.48143.350173YCW/0.6-1kv 3 X2 250 + 2X 25沿墻4-1隧道左線照明54.5797.635138YCW/0.6-1kv 4 X2 235 + 1X 16沿墻4-2隧道右線照 明54.5797.635138YCW/0.6-1kv 4 X352 + 1X 162沿墻4-3井口照明3358.91685YCW/0.6-1kv 4 X1
48、62+ 1X 62沿墻5-1井口防洪泵(左線)18.533.071064YCW/0.6-1kv 3 X102+ 1X 42沿墻5-2井口防洪泵(右線)18.533.071064YCW/0.6-1kv 3 X2 210 + 1X 4沿墻6-1庫(kù)房用電1017.9436YCW/0.6-1kv 3 X42+ 2X 1.5 2沿墻6-2鋼筋加工區(qū)1526.7646YCW/0.6-1kv 3 X42+ 2X 1.5 2沿墻6-3污水處理站2035.7646YCW/0.6-1kv 3 X102+ 2X 42沿墻7-1辦公區(qū)用電30.8551685YCW/0.6-1kv 4 X2 216 + 1X 6沿墻7
49、-2宿舍用電35.262.91685YCW/0.6-1kv 4 X2 216 + 1X 6沿墻7-3宿舍用電30.8551685YCW/0.6-1kv 4 X162+ 1X 62沿墻8-12#龍門吊140249.0295260YCW/0.6-1kv 3 X2 295 + 2X 50電纜溝9-1隧道風(fēng)機(jī)(右線)110196.6570215YCW/0.6-1kv 3 X2 270 + 1X 35沿墻9-2施工循環(huán)水 泵(右線)5598.325113YCW/0.6-1kv 3 X2 225 + 1X 10沿墻9-3循環(huán)水散熱 泵(右線)7.513.4436YCW/0.6-1kv 3 X42+ 1X
50、1.5 2沿墻10-1拖泵132235.995260YCW/0.6-1kv 3 X952 + 2 X 502電纜溝10-2砂漿儲(chǔ)料攪 拌罐7.513.4436YCW/0.6-1kv 3 X2 24 + 1X 1.5電纜溝10-3攪拌站88.5158.3950173YCW/0.6-1kv 3 X502 + 2 X 252電纜溝11-13#龍門吊(16T)65.5124.5150173YCW/0.6-1kv 3 X2 250 + 2X 25電纜溝11-2膨潤(rùn)土輸送 泵3053.61685YCW/0.6-1kv 3 X162+ 2X 62沿墻11-3膨潤(rùn)土攪拌5.59.9436YCW/0.6-1kv 3 X2 24 + 1X 1.5沿墻12-11#充電機(jī)2035.71685YCW/0.6-1kv 3 X2 210 + 2X 4沿墻12-21#充電機(jī)2035.71685YCW/0.6-1kv 3 X102+ 2X 42沿墻12-31#充電機(jī)2035.71685YCW/0.6-1kv 3 X102+ 2X 42沿墻12-41#充電機(jī)2035.71685YCW/0.6-1kv 3 X2 210 + 2X 4沿墻12-51#充電機(jī)2035.71685YCW/
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 京能集寧二期擴(kuò)建2×660MW熱電聯(lián)產(chǎn)工程節(jié)能報(bào)告的審查意見(jiàn)
- 淮安磁性金屬材料項(xiàng)目可行性研究報(bào)告
- 養(yǎng)殖鵝合同范本
- 農(nóng)業(yè)水果收購(gòu)合同范例
- 主播發(fā)貨合同范本
- 保底銷量合同范本
- PP凈化塔工程合同范例
- 倉(cāng)庫(kù)經(jīng)營(yíng)餐飲合同范例
- 2024年安全準(zhǔn)入考試復(fù)習(xí)試題含答案
- 養(yǎng)牛銷售合同范本
- 裝配式建筑預(yù)制構(gòu)件安裝-預(yù)制構(gòu)件的吊裝
- 2024年山東泰安市泰山財(cái)金投資集團(tuán)有限公司招聘筆試參考題庫(kù)含答案解析
- 上海天文館分析
- 中醫(yī)睡眠養(yǎng)生中心方案
- 生活中的邏輯學(xué)
- 大學(xué)生返家鄉(xiāng)社會(huì)實(shí)踐報(bào)告
- 初中生物中考真題(合集)含答案
- 《醫(yī)學(xué)免疫學(xué)實(shí)驗(yàn)》課件
- C139客戶開(kāi)發(fā)管理模型
- 中考英語(yǔ)閱讀理解(含答案)30篇
- GB/T 5019.5-2023以云母為基的絕緣材料第5部分:電熱設(shè)備用硬質(zhì)云母板
評(píng)論
0/150
提交評(píng)論