1、水電站建筑物課程設(shè)計(jì)有壓引水系統(tǒng)水力計(jì)算設(shè)計(jì)計(jì)算書姓 名 專 業(yè) 學(xué) 號(hào) 指導(dǎo)教師 時(shí) 間 目 錄第一部分 設(shè)計(jì)課題·······································31.設(shè)計(jì)內(nèi)容&

2、#183;···································32.設(shè)計(jì)目的·············

3、·······················3第二部分 設(shè)計(jì)資料及要求·························

4、;·······41.設(shè)計(jì)資料······································42.設(shè)計(jì)要求··

5、83;···································5第三部分 調(diào)壓井穩(wěn)定斷面計(jì)算············

6、················61.引水系統(tǒng)水頭損失······························62.引水道有效斷面

7、83;·······························83.穩(wěn)定斷面計(jì)算·················

8、··················8第四部分 調(diào)壓井水位波動(dòng)計(jì)算····························101.最高涌波水

9、位··································102.最低涌波水位··············&

10、#183;···················13第五部分 調(diào)節(jié)保證計(jì)算····························

11、······151.水錘計(jì)算······································152.轉(zhuǎn)速相對(duì)升高值···

12、;·····························19第六部分 附錄···················&#

13、183;·······················211.附 圖·························&

14、#183;···············212.參考文獻(xiàn)·································

15、;·····21第一部分 設(shè)計(jì)課題1.1 課程設(shè)計(jì)內(nèi)容對(duì)某水電站有壓引水系統(tǒng)水力計(jì)算1.2 課程設(shè)計(jì)目的通過課程設(shè)計(jì)進(jìn)一步鞏固所學(xué)的理論知識(shí),使理論與工程實(shí)際緊密結(jié)合。提高學(xué)生分析問題和解決實(shí)際問題的能力,計(jì)算能力和繪圖能力。第二部分 設(shè)計(jì)資料及要求2.1 設(shè)計(jì)資料某電站是MT河梯級(jí)電站的第四級(jí)。壩址以上控制流域面積2362,多年平均流量44.9,由于河流坡降較大,電站采用跨河修建基礎(chǔ)拱橋,在橋上再建雙曲拱壩的形式,壩高(包括基礎(chǔ)拱橋)54.8m。水庫為日調(diào)節(jié),校核洪水位1097.35m,相應(yīng)尾水位1041.32m;正常蓄水位1092.0m,相

16、應(yīng)尾水位1028.5m;死水位1082.0m,最低尾水位1026.6m??値烊?,。裝機(jī)容量,保證出力,多年平均發(fā)電量。該電站引水系統(tǒng)由進(jìn)水口、隧洞、調(diào)壓井及壓力管道四部分組成,電站平面布置及縱斷面圖如圖所示(指導(dǎo)書圖1,圖2)隧洞斷面采用直徑為5.5 m 的圓形,隧洞末端設(shè)一錐形管段,直徑由5.5 m漸變至5 .0m,錐管段長5.0m,下接壓力鋼管。隧洞底坡取0.005,全長500.3m ,其中進(jìn)水口部分長25.7m,進(jìn)口轉(zhuǎn)彎段長25.595m, 錐管段長為5 m。水輪機(jī)型號(hào)為HL211LJ225,閥門從全開到全關(guān)的時(shí)間為7s,其中有效關(guān)閉時(shí)間。機(jī)組額定轉(zhuǎn)速,飛輪力矩。蝸殼長度,尾水管長度。轉(zhuǎn)

17、輪出口直徑。經(jīng)核算,當(dāng)上游為正常蓄水位,下游為正常尾水位,三臺(tái)機(jī)滿發(fā)電,糙率n取平均值,則通過水輪機(jī)的流量為96.9,當(dāng)上游為死水位,下游為正常尾水位,三臺(tái)機(jī)滿發(fā),飲水道糙率區(qū)最小值,壓力管道糙率取最大值,則通過水輪機(jī)的流量為102。當(dāng)上游為校核洪水位,下游為相應(yīng)尾水位,電站丟棄兩臺(tái)機(jī)時(shí),若丟荷幅度為300000KW,則流量為63.60;丟荷幅度為4500015000KW,則流量變幅為96.531.0。當(dāng)上游為死水位,下游為正常尾水位時(shí),若增荷幅度為3000045000KW,則 流量變化為68.5102.5;若丟荷幅度為300000KW,則 流量變化為67.50。采用聯(lián)合供水方式,兩個(gè)卜形分岔

18、管布置,主管直徑5m,支管直徑3.4m,分岔角。從調(diào)壓井中心至蝴蝶閥中心,全長102.32m。如圖4-4可知,壓力管道可按鋼板、混凝土、圍巖聯(lián)合作用進(jìn)行結(jié)構(gòu)計(jì)算,圍巖單位彈性抗力系數(shù)為。取壓力管道經(jīng)濟(jì)流速為,按流量96.9進(jìn)行計(jì)算,壓力管道經(jīng)濟(jì)直徑為5m,蝸殼進(jìn)口直徑為3.4m,故設(shè)5m及3.4m兩種管徑,其中3號(hào)壓力管道由直徑5m過渡到3.4m錐管段長3.789m。三條壓力管道中以3號(hào)壓力管道最長,從隧洞末端到蝴蝶閥中心,全長113.3m。 計(jì)算時(shí)考慮不同的工況,隧洞糙率n分別取0.016,0.014,0.012;壓力管道的糙率n分別取0.013,0.012,0.011。2.2 設(shè)計(jì)要求:2

19、.2.1 對(duì)整個(gè)引水系統(tǒng)進(jìn)行水頭損失計(jì)算;2.2.2 進(jìn)行調(diào)壓井水力計(jì)算求穩(wěn)定斷面;2.2.3 進(jìn)行調(diào)壓井水力計(jì)算確定波動(dòng)振幅;(1)確定最高涌波水位(2)確定最低涌波水位2.2.4 進(jìn)行機(jī)組調(diào)節(jié)保證計(jì)算,檢驗(yàn)正常工作情況下水擊壓力、轉(zhuǎn)速相對(duì)升高是否滿足規(guī)范要求第三部分 調(diào)壓井穩(wěn)定斷面計(jì)算3.1 引水系統(tǒng)水頭損失3.1.1 局部水頭損失: 式中,為局部水頭損失系數(shù);()為斷面面積;g()取9.81;( m³/s)為通過斷面的流量,不同工況下分別取不同的值。經(jīng)列表計(jì)算結(jié)果如下:局部水頭損失計(jì)算表3-1欄號(hào)引水建筑物部位及運(yùn)行工況斷面面積局部水頭損失系數(shù) 局部水頭損失合計(jì)(1)進(jìn)水口攔污

20、柵61.280.121.628729.5499(2)進(jìn)口喇叭段29.760.105.7549(3)閘門井24.000.2017.6974(4)漸變段23.880.054.4689(5)隧洞進(jìn)口平面轉(zhuǎn)彎23.760.076.319819.5468(6)末端錐管段19.630.1013.2270(7)調(diào)壓井正常運(yùn)行19.630.1013.2270211.6315(8)增一臺(tái)機(jī)負(fù)荷、從調(diào)壓井流入管道19.631.50198.4046(9) 壓 力 引 水 管 道 上水平段平面轉(zhuǎn)彎19.630.045.2908428.9212(10)下水平段平面轉(zhuǎn)彎9.080.0849.4560(11)斜井頂部立面轉(zhuǎn)

21、彎19.630.0911.9043(12)斜井底部立面轉(zhuǎn)彎9.080.0955.6380(13)錐管9.080.0849.4560(14)三臺(tái)滿發(fā)1岔管19.630.3039.6809(15)三臺(tái)滿發(fā)2岔管19.630.4559.5214(16)一臺(tái)滿發(fā)1岔管19.630.2735.7128(17)一臺(tái)滿發(fā)2岔管19.630.2735.7128(18)蝴蝶閥9.080.1486.54803.1.2 沿程水頭損失: 式中,隧洞糙率系數(shù)n,可取0.016,0.014,0.012。壓力管道糙率系數(shù)n可取0.013,0.012,0.011。l(m)為引水道長,()為斷面面積, R(m)為水力半徑。列表

22、計(jì)算結(jié)果如下:欄號(hào)引水道部位過水面積濕周()水力半徑引水道長() 合計(jì)(1)進(jìn)水口喇叭口進(jìn)水段29.7621.981.3546.04522.65924750.183(2)閘門井段24.0020.001.2005.67624.134(3)漸變段23.8818.641.281110.012603.39(4)隧洞洞段23.7617.281.3756469.6543724.6572309.361(5)錐形洞段21.6516.491.31255.07423.154(6)調(diào)壓井前段19.6315.711.25010.9821161.59(7)壓力管道D=5m段1號(hào)岔道19.6315.711.25035.7

23、468881.18489754.114(8)1號(hào)2號(hào)岔道19.6315.711.25029.2156296.00(9)2號(hào)岔道19.6315.711.25012.2323570.70(10)錐管段13.8513.191.0503.9719392.71(11)D=3.4段9.0810.680.85021.35321613.5沿程水頭損失計(jì)算表3-23.2 引水道有效斷面:公式:,其中:調(diào)壓井前引水管的長度: 調(diào)壓井前引不同段水管的長度: 調(diào)壓井前引不同段水管的面積由沿程水頭損失計(jì)算表3-2中已知資料代入計(jì)算得: 故引水道的等效斷面積有:注:L(調(diào)壓井調(diào)壓井前引水管的長度)的第一分項(xiàng)4.1m為攔污

24、柵到喇叭口進(jìn)水段首部的長度,可由設(shè)計(jì)任務(wù)書圖4-3得知,其面積可由局部水頭損失表3-1得出。3.3 穩(wěn)定斷面計(jì)算: 所求的穩(wěn)定斷面需滿足各工況下運(yùn)行的要求,故計(jì)算時(shí)應(yīng)按電站在運(yùn)行時(shí)可能出現(xiàn)的最小水頭考慮。即上游為死水位(1082.0m),下游是最低尾水位(1026.6m),此時(shí)的流量為102,三臺(tái)機(jī)滿發(fā),引水道選用最小糙率0.012,壓力管道選用最大糙率0.013。采用水電站建筑物本書中得托馬斯斷面計(jì)算公式有:式中:為引水道長度,由3.2中計(jì)算得511.28m; 為引水道的等效斷面面積,由3.2中計(jì)算得23.8; 為靜水位,按所選工況計(jì)算得=1082.0-1026.6=55.4m; 為引水道的

25、水頭損失由局部水頭損失和沿程水頭損失組成 =1.405 m;為引水道阻力系數(shù),由教材中公式可得 ;為壓力管道中沿程水頭的損失;將所有參數(shù)代入托馬斯斷面計(jì)算公式有:安全系數(shù)K(1.0-1.1)取1.02,則托馬斯斷面調(diào)壓井直徑 第四部分 調(diào)壓井水位波動(dòng)計(jì)算4.1 最高涌波水位計(jì)算調(diào)壓室最高涌波水位,應(yīng)出現(xiàn)在最高庫水位丟棄全負(fù)荷的情況下,由設(shè)計(jì)計(jì)劃書中已知資料,可知存在兩種情況:4.1.1第一種情況:上游為校核水位,下游為相應(yīng)尾水位,電站丟棄兩臺(tái)機(jī)時(shí),丟荷幅度為300000KW,流量變化為63.60。解析法計(jì)算步驟如下:要求出最高涌波水位,只需求出即可。參考教材水電站建筑物公式得 ,分析可知:當(dāng)n

26、取最大值時(shí),由曼寧公式和謝才公式可知沿程阻力系數(shù)最大,沿程水頭損失最大,也即最大,此時(shí)最小。故取=0.016,此時(shí)Q=63.6m³/s, 參考教材水電站建筑物150頁圖10-4 =0.1時(shí),橫坐標(biāo)為0.35,小圖有7.5格,每格值為0.047=0.024時(shí),小圖有3.5格,值約為取,故故最高涌波水位為1097.35+5.55=1102.90 m.4.1.2第二種情況:上游為校核水位,下游為相應(yīng)尾水位,電站丟棄兩臺(tái)機(jī)時(shí),丟荷幅度為4500030000KW,流量變化為96.531.0圖解法計(jì)算步驟如下:水位波動(dòng)的理論周期T為: t取T/25T/30左右,即取值在3.9-4.7S之間取平均

27、值t=4.3s 坐標(biāo)橫軸表示引水道流速v,以原點(diǎn)向左為正,縱軸表示水位z,向上為正,橫軸相當(dāng)于靜水位畫輔助曲線:作引水道的水頭損失曲線 假定幾個(gè)值,由公式計(jì)算相應(yīng)的值結(jié)果如下 00.511.522.533.544.5500.060.250.571.011.582.273.094.03 5.16.3(1)用描點(diǎn)法可擬繪出關(guān)系曲線。(2)繪制關(guān)系曲線:它是通過原點(diǎn)O的直線,對(duì)縱坐標(biāo)軸的斜率=0.083,與原點(diǎn)相連即得。(3)繪制關(guān)系曲線:若全部丟棄負(fù)荷時(shí),A為0,曲線是一條斜率為a=0.64通過原點(diǎn)的直線;若部分丟棄負(fù)荷時(shí),由流量和流速即可求出一點(diǎn),斜率為a=0.64,即可畫出一條直線,該工況下部

28、分丟棄負(fù)荷,A=0.83,圖解計(jì)算: (見第六部分附圖6-1)Zmax= 8.09 m所以最高涌波水位為1097.35 +8.09 = 1105.44 m.故綜合解析法與數(shù)解法得最高涌波水位1105.444.2 最低涌波水位計(jì)算當(dāng)上游為最低水位,丟棄負(fù)荷或增加負(fù)荷時(shí)都可能出現(xiàn)最低涌波水位,故存在如下兩種情況:4.2.1第一種情況: 當(dāng)上游為死水位,下游為正常尾水位,增荷幅度為3000045000KW,流量變化為68.5102.5。解析法計(jì)算步驟如下:增荷時(shí)由部分負(fù)荷增加到全負(fù)荷,則可按福格特公式求最低涌波水位,如下:式中,為最低涌高水位;為引水道水頭損失,對(duì)于無阻抗圓筒式為無因次系數(shù),為負(fù)荷系

29、數(shù)。取流量為102.5,糙率取0.016 參考教材水電站建筑物151頁圖10-5得到 故最低涌波水位為1082-6.44=1075.56m圖解法計(jì)算步驟如下:取t=4.3s 按照丟棄負(fù)荷的方法選擇同標(biāo)系統(tǒng),繪出關(guān)系曲線并繪出輔助曲線和圖解計(jì)算: (見第六部分附圖6-2)6.447 m所以最低涌波水位為1082-6.447 =1075.55 m4.2.2第二種情況:丟荷幅度為300000KW,流量變化為67.50解析法計(jì)算步驟如下:4.1.1中已計(jì)算出丟荷幅度為300000KW時(shí)最高涌波水位的參考教材水電站建筑物150頁圖10-4得:所以最低涌波水位為1082-4.37=1077.63m第五部分

30、 調(diào)節(jié)保證計(jì)算5.1 水錘計(jì)算由設(shè)計(jì)計(jì)劃書可知:電站采用聯(lián)合供水方式,有兩個(gè)卜型岔管,主管直徑為5m,支管直徑為3.4m,分岔角29o27。壓力管道的經(jīng)濟(jì)直徑5m,蝸殼進(jìn)口直徑為3.4m,有5m及3.4m兩種管道,其中3#壓力管道由直徑5m過渡到3.4m錐管鍛長度為3.789m。5.1.1 壓力管道中水錘類別的判斷水錘波傳播速度式中 聲音在水中的傳播速度(一般可取1435m/s); 水的體積彈性模量,; 管道半徑,取2.5m; 管道抗力系數(shù),埋藏式壓力管道由鋼板由混凝土和圍巖聯(lián)合作用 鋼板彈性模量,取低碳鋼210GPa;管壁厚度,取最大0.014m;混凝土抗力系數(shù),考慮其開裂,令其等于0;圍巖

31、單位彈性抗力系數(shù),取所以水錘波傳播速度壓力管道總長L,取調(diào)壓井中心到蝴蝶閥中心全長102.32m;則因此壓力管道中發(fā)生間接水錘5.1.2等價(jià)水管法計(jì)算一般在采用解析方法時(shí),簡(jiǎn)單地認(rèn)為可不考慮分岔管的影響,而只按最長的那根管道簡(jiǎn)化成等價(jià)水管進(jìn)行分析計(jì)算,三條壓力管道中3號(hào)壓力管道最長,取該串聯(lián)管為調(diào)保計(jì)算的等價(jià)管。又3號(hào)壓力管道各段管徑厚度等參數(shù)同,故下按串聯(lián)管計(jì)算等價(jià)水管計(jì)算每段壓力管道的抗力系數(shù):。其中5m到3m錐管過渡段采用平均直徑4m壓力管道相關(guān)參數(shù)表5-1段號(hào)樁號(hào)管徑(m)壁厚 (m)長度L(m)流速V(m/s)抗力系數(shù)K波速a(m/s)10+480.9815.0 0.0135.744.9456.3 1414.0720+511.9635.0 0.01212.233.2956.4 1414.0930+521.3295.0 0.01216.983.2956.4 1414.0940+534.3365.0 0.01412.231.6456.5 1414.1250+543.7025.03.40.0123

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論