1、RoH哪保測試儀作業(yè)指導(dǎo)書RoHS environmental testing working instruction 班級: 姓名: 學(xué)號 目的purpose :為正確使用儀器,避免因不當(dāng)使用導(dǎo)致儀器損壞,確保儀器使用壽命及測試準(zhǔn)確度。For the proper use of equipment, avoid the improper use of cause equipment damage, ensure the service life of the apparatus and testing accuracy.二.范圍 Range :用于進料、制程、出貨階段之(原物料、輔材、半成品

2、、成品等)環(huán)境有害物質(zhì)檢 測分析。For feed, process, ship stage (raw materials, semi-finished products, finished products such as auxiliary, environmental hazardous substances testing analysis).三.權(quán)責(zé) Responsibilities :3.1.儀校人員負(fù)責(zé)操作指導(dǎo)書制定。1.1. Instrument school personnel responsible for operating instructions.1.2. 測試人員負(fù)

3、責(zé)儀器保養(yǎng)與維護。1.3. The test personnel responsible for the equipment maintenance and maintenance.1.4. 測試人員必須為接受過相關(guān)儀器操作培訓(xùn)合格之品保課人員。1.5. The test must have received relevant equipment operation training of qualified quality assurance staff.4 . 儀器開機與關(guān)機順序 Instrument boot and shutdown sequence:4.1. 開機順序:開穩(wěn)壓電源 f

4、 開測試儀(綠火T亮)開電腦主機 打開測試 程序軟件。4.2. boot sequence: regulated power supply testing instrument (green light) to open the computer host open test software.4.3. 關(guān)機順序:退出測試程序軟件關(guān)電腦主機一關(guān)測試儀一關(guān)穩(wěn)壓電源。4.4. The shutdown sequence: exit test software to turn off the computer shut off power supply tester host.5 .指示燈說明 In

5、dicator description :5.1. 綠燈-電源指示燈:打開儀器電源此燈亮。5.1 - green power indicator: open the instrument power the lights.5.2. 黃燈-運行指示燈:儀器測試運行時此燈亮,測試結(jié)束此燈自動熄滅。5.3. yellow lights - running indicator: instrument test running the lights, the end of the test the lamp is automatically extinguished.6 .操彳流程 Operation

6、process :6.1.每次開機時,首先需對儀器進行預(yù)熱30分鐘,具體預(yù)熱步驟如下:6.1. When starting up every time, the apparatus for preheating for 30 minutes, the preheating step as follows6.1.1 apply (plastic sample) into the testing table click sample to view the sample placed on the toolbar參數(shù)設(shè)置設(shè)置預(yù)熱時間(1800)秒一點擊測塑料中Cr Cl測量曲線點擊開 始鍵目輸入樣

7、品Aparameters preheat time (1800 seconds) click on the Cr Cl measurement measuring plastic curve click Start button input samples信息(任意輸入),點擊確定預(yù)熱測量開始(黃燈亮),待1800秒測試時間終止,本次預(yù) 熱即完成。Information (arbitrary input), click OK to preheat the measurement start (yellow light), to be 1800 seconds test time expires

8、, the preheating is finished.6.2. 每次開機后或(儀器測試程序軟件關(guān)閉后再打開)需測量產(chǎn)品前,必須先用純 銀校正片作初始化校正,在此動作順利通過情況下,方能繼續(xù)下一步操作。具體初始化 步驟如下:6.3. After each reboot or (instrument testing software is closed and then opened) for measuring product, must first use silver correction piece as initialization correcting, this moves sm

9、oothly through the case, to continue the next operation.The initialization procedure is as follows:“1105”道,否則需重新進行初始化達到要求為止。6.3.1 select the toolbars parameters of (initialization), prompted by the school in sterling silver. Click OK to start the initialization initialization, after the success of t

10、he state bar of peak channel need to display as "1105", or the need to initialize meet the required date.6.4. 樣品測試操作步驟如下:6.3 sample test steps are as follows:6.3.1 measurement time settings: select the toolbars parameters of (measure time), appears in the dialog box input time (units / sec

11、), click on the OK set complete.(setting time is generally 200 seconds, if the result is not accurate when may be appropriate to extend the time measurement)6.3.2 measurement time settings: select the toolbars parameters of (measure time), appears in the dialog box input time (units / sec), click on

12、 the OK set complete.(setting time is generally 200 seconds, if the result is not accurate when may be appropriate to extend the time measurement)里,按系統(tǒng)提示輸入樣品信息后,點擊OK后測試開始,運行指示黃燈亮,若需停止測試,點擊工具欄停止鍵即可,測試完成黃燈自動熄滅。(樣品細微時放入測試杯中再進行測試,測試運行中可點擊譜圖查看測試狀況)6.3.3 test:the measured object in test bench, click on th

13、e sample view objects, adjust the object position, until the show clearly the sample surface.Click on the toolbar to start 上-,prompted by the input sample information, click on the OK after the test, operation indicating light, if it is necessary to stop the test, click the toolbar button stop,test

14、complete yellow lamp is automatically extinguished.(fine when placed inthe test sample cup for testing, test run can click spectrum view test status)若無需保存只打印測試報告,測試完成后點擊(分析報告打印)即可If no need to save the only print test reports, after the test is completed click (analysis report print)6.4.儀器校正:選擇綠色塑膠校

15、正片(ERM -EC681K )按6.3內(nèi)容執(zhí)行,測試完 成查看測試報告并對照校正片標(biāo)準(zhǔn)值,容許偏差在土 10PpM左右,若偏差過大,需聯(lián)系 儀器生產(chǎn)廠商進行處理。6.4 calibration: choose green plastic correction sheet (ERM - EC681K) according to the 6.3 elements of the implementation, testing complete view test report and control the correction sheet standard value, allowable de

16、viation is in the range of about 10PPM, if the deviation is too large, need to contact the equipment manufacturers processing(為使儀器測試準(zhǔn)確,需不定期用校正片對測試參數(shù)進行校對,確保儀器之準(zhǔn)確性) (apparatus for making accurate test, need not regularly using the correction sheet of test parameters on proofreading, ensure that the in

17、strument accuracy) 七. 注意事項 Matters needing attention:7.1 測試工作臺及儀器保持潔凈,如有雜物灰塵可用干軟布或酒精棉球擦拭干凈。7.2 test bench and apparatus to keep clean, if there is debris dust free dry soft cloth or alcohol cotton to wipe clean7.3 測試物件放置工作臺時注意不可使塵粒掉入其中,以防污染工作臺窗口導(dǎo)致測量不準(zhǔn)確。7.4 test objects placed a careful not to fall i

18、nto the dust, to prevent the pollution of workbench window lead to inaccurate measurements7.5 測試物件放置時需輕拿輕放,以免工作臺窗口薄膜破損,樣品掉入儀器內(nèi)損壞儀 器。7.6 test objects placed to light-light, lest the workbench window film damage, damage the instrument within the apparatus samples fall into.7.7 短時間不使用儀器,勿須關(guān)掉儀器電源,以免重新打開

19、電源又須進行儀器預(yù)熱7.8 short time without the use of instruments, do not turn off the power equipment, so as not to reopen the power supply must be instrument preheat7.9 開機后長時間( 2-3 小時)未使用儀器時,若需做測試須進行初始化。7.10 boot after long time (2-3 hours) without the use of instruments, if it is necessary to do tests should be initialized.7.11 測試數(shù)據(jù)疑不準(zhǔn)確時,可重新測試并適當(dāng)延長測試時間,提高儀器分析準(zhǔn)確性。7.6 The test data that is not accurate, can test and extend the testing time, improve the accuracy of instru

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

最新文檔

評論

0/150

提交評論