1、淺談對(duì)現(xiàn)澆鋼筋混凝土框架柱偏移的處理符世衡(黑龍江省北安市匯眾建筑勞務(wù)施工隊(duì)劉敬波(北安市建筑工程管理處摘要論述了現(xiàn)澆鋼筋混凝土框架柱偏移的幾種處理方法和注意事項(xiàng)。關(guān)鍵詞現(xiàn)澆鋼筋混凝土框架柱;豎向偏移;加補(bǔ)配筋法;型鋼加固法Treatment Of The Deflection Of C ast-I n-Site R einforced Concrete Frame BeamFu Shiheng(Huizhong Architecture Labor C onstruction T eam O f Beian CityLiu Jingbo(Architecture Engineering Ma

2、nagement Department O f Beian CityAbstract:This paper states several treatment methods and precautions of the deflection of cast-in-site reinforced con2 crete frame beam.K ey w ords:cast-in-site reinforced concrete;deflection;adding reinforced method;profiled bar strengthening method近年來(lái),現(xiàn)澆鋼筋混凝土框架結(jié)構(gòu)無(wú)

3、論是在民用建筑、工業(yè)建筑和其他建筑中應(yīng)用都十分廣泛。其特點(diǎn)是空間剛度好,傳遞荷載較均勻,便于取材與施工。在該結(jié)構(gòu)體系中,框架柱的傳遞荷載的作用十分明顯,由他將上部各種荷載層層傳遞至基礎(chǔ),作用與地基。因此研究和探討現(xiàn)澆混凝土框架柱在實(shí)際施工中的偏移問(wèn)題與處理方案尤為重要。本文僅就現(xiàn)澆鋼筋混凝土框架豎向偏移的處理方法敘述如下。1現(xiàn)澆鋼筋混凝土框架偏移的驗(yàn)算方法及加固原則現(xiàn)澆鋼筋混凝土框架柱由于定位放線、模板固定支護(hù)原因?qū)е轮哟怪倍绕撇畛鲈试S值,將產(chǎn)生附加內(nèi)力。由于現(xiàn)澆混凝土框架有一定的剛性和延性能承受較大的垂直荷載和水平荷載,而柱的主要內(nèi)力有軸向力N和彎短M,但他的剪應(yīng)力Q往往較小,所以我們

4、可以近似地按下列步驟進(jìn)行驗(yàn)算:先找出產(chǎn)生豎向偏差的柱頂部原有不利荷載組合值M及相應(yīng)N,或者是找出N及相應(yīng)M。特別要注意核算出M值與附加彎短M同方向的值。接著計(jì)算M值,即N乘以實(shí)際柱子偏離設(shè)計(jì)位置的距離,最后依據(jù)總彎矩(即M+M,同號(hào)相加,異號(hào)相減及N值重新計(jì)算柱載面配如。如果算得的配筋量小于或等于原有柱內(nèi)配筋量,則該柱不用加固處理,否則應(yīng)采取加固措施。如果柱頂、柱底部皆發(fā)生豎向偏差,應(yīng)選取二者間的不利組作為驗(yàn)算對(duì)象。其驗(yàn)算方法參見(jiàn)現(xiàn)澆鋼筋混凝土框架設(shè)計(jì)中的驗(yàn)算方法。原由柱內(nèi)的配筋量如果符合柱子偏移后強(qiáng)度要求時(shí),該柱子可以不習(xí)采取加固措施。但是在任何情況下,柱子發(fā)生偏差后,原設(shè)計(jì)位置中心線必須保

5、持在柱子截面之內(nèi),且該中心線亢柱子截面外邊緣的距離大于50mm以確保整個(gè)結(jié)構(gòu)的安全和穩(wěn)定。否則該柱應(yīng)拆掉返工重新施工。在不違反上述原則的基礎(chǔ)上,對(duì)偏移框架柱進(jìn)行加固,加固方法如下:2加補(bǔ)配筋法首先計(jì)算出需增加的附加主筋(即求算的配筋量與原有配筋的差值,將附加主筋每隔500mm與去掉保護(hù)層后的原有主筋焊接,用25,長(zhǎng)150mm的短筋作墊塊,沿柱高每隔500mm與柱內(nèi)相應(yīng)的主筋和附加筋相焊接(短筋處的混凝土保護(hù)層需事先鑿干凈。焊后將柱混凝土面(加固面鑿毛,刷洗干凈,再澆一層混凝土強(qiáng)度高于原設(shè)計(jì)柱混凝土強(qiáng)度一級(jí)的細(xì)石混凝土。為保證加固澆筑混凝土質(zhì)量、新增截面厚度不小于50mm。支模采用至下而上分段支

6、模,分段澆筑目的是為了保證澆筑振搗密實(shí)。3型鋼加固法用4根通長(zhǎng)角鋼包住柱的四個(gè)角,角鋼的規(guī)格尺寸依照需要加固柱的截面尺寸而定,一般不小于5050。在角鋼間焊上水平扁鋼或鋼筋,扁鋼不小于404,間距不宜大于150mm,形成一個(gè)鋼套,再用12水泥砂漿覆蓋型鋼套。用型鋼套加固補(bǔ)強(qiáng)效果好,且施工速度快,省工省力,但耗鋼量較大。4其它加固法在條件許可時(shí),可采用增強(qiáng)支點(diǎn),增加支撐,加設(shè)橫梁和四面包套加大柱斷面面積等措施改變結(jié)構(gòu)受力形成,使豎向軸力不變,彎短值不變。5利用澆搗上層柱時(shí)糾正偏差當(dāng)下層有豎向偏差柱處理完畢后,在澆上層柱時(shí),一般不宜一次糾正到位,以避免柱產(chǎn)生過(guò)大偏移,形成突變。突變對(duì)結(jié)構(gòu)的正常受力

7、,建筑外形和安全都產(chǎn)生不利影響。因此應(yīng)采用逐層糾偏的方法,即依澆筑層上面的層數(shù)和層高,層層逐步糾偏。這樣做可保證結(jié)構(gòu)受力合理、安全、對(duì)建筑立面外形的影響較小。6在處理混凝土框架框偏移過(guò)程中應(yīng)注意的事項(xiàng)762008V ol140N o12林業(yè)科技情報(bào)611凡柱偏移的框架,要注意加強(qiáng)框架平面外的連系梁或使其結(jié)構(gòu)成雙向框架,以提高整體剛性,增加整個(gè)結(jié)構(gòu)體系的空間剛度。612框架柱豎向偏移后,常會(huì)影響到梁柱節(jié)點(diǎn)處。梁內(nèi)受力筋伸入柱內(nèi)長(zhǎng)度不夠,會(huì)使錨固筋過(guò)早彎折,導(dǎo)致混凝土應(yīng)力集中。因此要保證橫梁受力筋有可靠的錨固長(zhǎng)度。613當(dāng)柱子因豎向偏移致使原設(shè)計(jì)的中心線不通過(guò)柱截面時(shí),在連接節(jié)點(diǎn)中產(chǎn)生的附加內(nèi)力不

8、可忽視。遇此情況本文的近似計(jì)算已不適用,應(yīng)另行按實(shí)際進(jìn)行計(jì)算,根據(jù)計(jì)算值,采用相適應(yīng)的補(bǔ)強(qiáng)加固措施。7結(jié)束語(yǔ)總而言之,在鋼筋混凝土框架結(jié)構(gòu)施工中,重視放線,專人復(fù)核,避免出現(xiàn)超差偏移。一但出現(xiàn),要認(rèn)真對(duì)待,及時(shí)處理,并會(huì)同設(shè)計(jì)單位采用適當(dāng)?shù)募夹g(shù)措施,保證建筑物安全使用。來(lái)稿日期:2007-12-20異型柱與短肢剪力墻結(jié)構(gòu)設(shè)計(jì)中的幾個(gè)問(wèn)題趙巍洪林(黑龍江省林業(yè)設(shè)計(jì)研究院摘要論述了異型柱與短肢剪力墻結(jié)構(gòu)設(shè)計(jì)中應(yīng)注意的問(wèn)題,并介紹了其優(yōu)點(diǎn)、計(jì)算及構(gòu)造要求。關(guān)鍵詞異型柱;短肢剪力墻Several Problems I n The Structure Design OfPhocomelia Shear

9、W all With Profiled ColumnZhao WeiH ong Lin(F orest Design And Research Institute O f Heilongjiang ProvinceAbstract:This paper states several problems in the structure design of phocomelia shear wall with profiled column.It als o introduces its advantages,calculation and conformation demands.K ey w

10、ords:profiled column;phocomelia shear wall現(xiàn)在住宅建筑一般要求大開(kāi)間,平面及房間布置靈活、方便,室內(nèi)不應(yīng)露出梁柱等。異形柱與短肢剪力墻結(jié)構(gòu)使用能較好地滿足現(xiàn)代住宅建筑的要求;且這種格局的高層住宅各單元的通風(fēng)采光良好,平面緊湊,還較為經(jīng)濟(jì)。1現(xiàn)代住宅中使用異型柱與短肢剪力墻的優(yōu)點(diǎn)與普通的剪力墻相比,短肢剪力墻門窗洞口更大,可以較好地滿足住宅建筑的采光與通風(fēng)要求,增加使用面積,造價(jià)較低;由于減少剪力墻的數(shù)量,代之以輕質(zhì)填充墻,結(jié)構(gòu)自重更小,且適當(dāng)?shù)慕档土私Y(jié)構(gòu)剛度,使地震作用減少。在結(jié)構(gòu)上,既可以承受豎向荷載,又可以抵抗水平地震作用。111結(jié)合建筑平面,利用

11、間隔墻位置來(lái)布置豎向構(gòu)件,基本不與建筑使用功能發(fā)生矛盾。墻的數(shù)量通過(guò)結(jié)構(gòu)計(jì)算可多可少,肢可長(zhǎng)可短,主要視抗側(cè)力的需要而定,還可通過(guò)不同的尺寸和布置以調(diào)整剛度中心的位置。112能靈活布置,可調(diào)整性大,可選擇的方案較多,較易處理支承樓蓋的要求,得出合理的結(jié)構(gòu)方案。113連接各墻的梁,亦隨墻肢位置而位于間隔墻的豎平面內(nèi),基本屬于隱蔽型的。2異型柱與短肢剪力墻的構(gòu)造要求211短肢墻的布置合理,對(duì)稱,均勻,力求質(zhì)量中心與剛度中心重合,短肢墻布置應(yīng)以T形,L形,形,+形為主,這樣可增加短肢墻抗扭和平面外穩(wěn)定。212短肢墻受力以承擔(dān)豎向荷載為主,承擔(dān)水平荷載為輔,其截面尺寸要適當(dāng),墻肢截面高度與厚度之比宜在5 8左右為好,且墻厚不小于200mm,當(dāng)墻肢截面高度與厚度比小于等于3時(shí),應(yīng)按柱的要求進(jìn)行設(shè)計(jì),短肢墻在重力荷載代表值作用下產(chǎn)生的軸力設(shè)計(jì)值的軸壓比,抗震等級(jí)為一,二,三時(shí)分別不宜大于015,016,017。對(duì)于無(wú)翼緣或端柱的一字形短肢剪力墻,因其延性更為不利,因此軸壓比限值要相應(yīng)降低011。213各短肢墻應(yīng)盡量對(duì)齊,拉直,使之與連梁一起構(gòu)成較規(guī)則且連續(xù)均勻的抗側(cè)力片,并且每道短肢墻宜有兩個(gè)方向的梁與之連接??拐鹪O(shè)計(jì)時(shí),短肢剪力墻截面的縱向鋼筋的配筋率,底部加強(qiáng)部位不宜小于112%,其它部位不宜小于110%。214短肢剪力墻筒體結(jié)構(gòu)體系,電算分析力學(xué)模型建議采用高層建筑結(jié)構(gòu)空間有限

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論