1、機(jī)組軸線處理案例孫德敏0102河口水電站機(jī)河口水電站機(jī)組設(shè)備簡介組設(shè)備簡介1機(jī)組振擺異常機(jī)組振擺異常缺陷現(xiàn)象缺陷現(xiàn)象2機(jī)組存在的機(jī)組存在的主要問題主要問題3機(jī)組振擺異常機(jī)組振擺異常分析處理過程分析處理過程4機(jī)組振擺異常機(jī)組振擺異常處理結(jié)論處理結(jié)論5河口水電站2#機(jī)組振擺異常分析處理河口水電站位于四川九龍縣子耳鄉(xiāng)境內(nèi),河口水電站位于四川九龍縣子耳鄉(xiāng)境內(nèi),電站發(fā)電機(jī)組單機(jī)容量電站發(fā)電機(jī)組單機(jī)容量18MW18MW,裝機(jī)臺(tái)數(shù),裝機(jī)臺(tái)數(shù)2 2臺(tái)。水輪機(jī)型號(hào):臺(tái)。水輪機(jī)型號(hào):HLD358c-LJ-156,HLD358c-LJ-156,轉(zhuǎn)輪轉(zhuǎn)輪直徑:直徑:1.56m,1.56m,額定出力額定出力18.75M

2、W18.75MW,額定轉(zhuǎn),額定轉(zhuǎn)速速600r/min600r/min,額定水頭,額定水頭219m219m。水導(dǎo)軸承承受機(jī)組載荷,采用筒式軸承,水導(dǎo)軸承承受機(jī)組載荷,采用筒式軸承,軸瓦表面采用巴式合金材料,軸瓦表面軸瓦表面采用巴式合金材料,軸瓦表面與軸領(lǐng)間隙為與軸領(lǐng)間隙為0.15-0.2mm0.15-0.2mm,由油冷器進(jìn),由油冷器進(jìn)行冷卻,軸承油冷器為分半水箱式結(jié)構(gòu),行冷卻,軸承油冷器為分半水箱式結(jié)構(gòu),位于軸承體下部。位于軸承體下部。設(shè)備簡介發(fā)電機(jī)采用具有上下兩個(gè)導(dǎo)軸承的立軸發(fā)電機(jī)采用具有上下兩個(gè)導(dǎo)軸承的立軸懸式結(jié)構(gòu),推力軸承置于上機(jī)架上,推懸式結(jié)構(gòu),推力軸承置于上機(jī)架上,推力軸承與上導(dǎo)軸承共

3、用一個(gè)油槽,并采力軸承與上導(dǎo)軸承共用一個(gè)油槽,并采用內(nèi)循環(huán)冷卻方式。發(fā)電機(jī)型號(hào):用內(nèi)循環(huán)冷卻方式。發(fā)電機(jī)型號(hào):SF18-SF18-10/3250,10/3250,定子內(nèi)徑定子內(nèi)徑2500mm2500mm。缺陷現(xiàn)象 2#2#機(jī)組在空轉(zhuǎn)、空載、負(fù)荷機(jī)組在空轉(zhuǎn)、空載、負(fù)荷1.21.2萬萬kwkw時(shí),運(yùn)行平穩(wěn),時(shí),運(yùn)行平穩(wěn),擺度、各部瓦溫均在要求范圍內(nèi),在擺度、各部瓦溫均在要求范圍內(nèi),在1.21.2萬萬kwkw以上時(shí),機(jī)以上時(shí),機(jī)組運(yùn)行部平穩(wěn),擺度、瓦溫變化幅度較大,水導(dǎo)瓦溫最組運(yùn)行部平穩(wěn),擺度、瓦溫變化幅度較大,水導(dǎo)瓦溫最高達(dá)到高達(dá)到6161,下導(dǎo)擺度達(dá)到,下導(dǎo)擺度達(dá)到0.27mm0.27mm。且機(jī)

4、組在下午。且機(jī)組在下午3 3點(diǎn)點(diǎn) 晚上晚上9 9點(diǎn)運(yùn)行狀態(tài)較好,晚上點(diǎn)運(yùn)行狀態(tài)較好,晚上9 9點(diǎn)以后開始變差。同時(shí),點(diǎn)以后開始變差。同時(shí),定子鐵芯溫度單機(jī)運(yùn)行時(shí)最高達(dá)到定子鐵芯溫度單機(jī)運(yùn)行時(shí)最高達(dá)到9191,最低也有,最低也有8585。下導(dǎo)擺度下導(dǎo)擺度水導(dǎo)擺度水導(dǎo)擺度水導(dǎo)瓦溫水導(dǎo)瓦溫備備 注注初次開機(jī)0.15mm0.22 mm56空轉(zhuǎn)3小時(shí)瓦溫穩(wěn)定試驗(yàn)初次并網(wǎng)滿負(fù)荷0.20 mm0.24 mm 56(上升)18MW并網(wǎng)1h12h0.27 mm0.24 mm6118MW并網(wǎng)12h之后0.20 mm0.22 mm5818MW并網(wǎng)后4天中(最好)0.18 mm(01:00)0.09 mm5618MW

5、并網(wǎng)后4天中(最差)0.20 mm(17:0018:00)0.20mm5818MW2#2#機(jī)組調(diào)試試運(yùn)行狀態(tài)表機(jī)組調(diào)試試運(yùn)行狀態(tài)表60754020機(jī)組擺度和振動(dòng)、水導(dǎo)瓦溫時(shí)高時(shí)低,機(jī)組擺度和振動(dòng)、水導(dǎo)瓦溫時(shí)高時(shí)低,機(jī)組狀況不穩(wěn)定(尤其是上游浮渣較機(jī)組狀況不穩(wěn)定(尤其是上游浮渣較多時(shí),浮渣沖到水輪機(jī)葉片內(nèi))多時(shí),浮渣沖到水輪機(jī)葉片內(nèi))機(jī)組運(yùn)行聲音異常、噪音較大機(jī)組運(yùn)行聲音異常、噪音較大上導(dǎo)滑轉(zhuǎn)子盤車位移過大(盤車時(shí)抱上導(dǎo)滑轉(zhuǎn)子盤車位移過大(盤車時(shí)抱上導(dǎo)瓦作為基準(zhǔn),擺度應(yīng)該在上導(dǎo)瓦作為基準(zhǔn),擺度應(yīng)該在0-0-0.03mm0.03mm內(nèi),但實(shí)際高達(dá)內(nèi),但實(shí)際高達(dá)0.14mm0.14mm)發(fā)電機(jī)定子剛

6、進(jìn)行過重新疊片和下線,發(fā)電機(jī)定子剛進(jìn)行過重新疊片和下線,可能存在電磁力不平衡可能存在電磁力不平衡 20142014年年7 7月,對(duì)月,對(duì)2#2#機(jī)組進(jìn)行了軸線檢查,發(fā)現(xiàn)上導(dǎo)滑轉(zhuǎn)子與軸線不同心。機(jī)組進(jìn)行了軸線檢查,發(fā)現(xiàn)上導(dǎo)滑轉(zhuǎn)子與軸線不同心。 經(jīng)多次檢修盤車,發(fā)現(xiàn)上導(dǎo)(盤車時(shí)抱上導(dǎo))的擺度達(dá)經(jīng)多次檢修盤車,發(fā)現(xiàn)上導(dǎo)(盤車時(shí)抱上導(dǎo))的擺度達(dá)0.14mm0.14mm。經(jīng)測量外徑,。經(jīng)測量外徑,上導(dǎo)滑轉(zhuǎn)子處直徑偏差不大(數(shù)據(jù)見下表)。初步分析,認(rèn)為滑轉(zhuǎn)子與軸線不同上導(dǎo)滑轉(zhuǎn)子處直徑偏差不大(數(shù)據(jù)見下表)。初步分析,認(rèn)為滑轉(zhuǎn)子與軸線不同心,存在傾斜。懷疑產(chǎn)生此現(xiàn)象原因?yàn)椋夯D(zhuǎn)子在與大軸熱套時(shí),由于配合面毛

7、心,存在傾斜。懷疑產(chǎn)生此現(xiàn)象原因?yàn)椋夯D(zhuǎn)子在與大軸熱套時(shí),由于配合面毛刺或雜質(zhì)未清理干凈,造成滑轉(zhuǎn)子的中心軸線與大軸軸線交叉不重合。刺或雜質(zhì)未清理干凈,造成滑轉(zhuǎn)子的中心軸線與大軸軸線交叉不重合。點(diǎn)點(diǎn) 號(hào)號(hào)1#1#2#2#3#3#4#4#5#5#6#6#7#7#8#8#+X+X表數(shù)值表數(shù)值0694-2-7-8-6+Y+Y表數(shù)值表數(shù)值-60-1-3-8-13-13-11上導(dǎo)擺度測量上導(dǎo)擺度測量( (單位單位0.01mm)0.01mm) 在抱緊上導(dǎo)瓦盤車過程中,上導(dǎo)滑轉(zhuǎn)子傾斜將導(dǎo)致上導(dǎo)出現(xiàn)擺度,并影響其在抱緊上導(dǎo)瓦盤車過程中,上導(dǎo)滑轉(zhuǎn)子傾斜將導(dǎo)致上導(dǎo)出現(xiàn)擺度,并影響其他部位擺度的準(zhǔn)確測量。正常情況下

8、,抱瓦部位只存在他部位擺度的準(zhǔn)確測量。正常情況下,抱瓦部位只存在0.010.03mm0.010.03mm的徑向位移。的徑向位移。為驗(yàn)證上導(dǎo)滑轉(zhuǎn)子是否存在傾斜,此次盤車單獨(dú)測量了上導(dǎo)滑轉(zhuǎn)子上端面的跳動(dòng)為驗(yàn)證上導(dǎo)滑轉(zhuǎn)子是否存在傾斜,此次盤車單獨(dú)測量了上導(dǎo)滑轉(zhuǎn)子上端面的跳動(dòng)(數(shù)據(jù)見下表)。跳動(dòng)值最大達(dá)(數(shù)據(jù)見下表)。跳動(dòng)值最大達(dá)0.27mm0.27mm,且變化富有規(guī)律,基本證實(shí)了上導(dǎo)滑轉(zhuǎn),且變化富有規(guī)律,基本證實(shí)了上導(dǎo)滑轉(zhuǎn)子與軸線不同心,存在傾斜現(xiàn)象。子與軸線不同心,存在傾斜現(xiàn)象。上導(dǎo)滑轉(zhuǎn)子上端面跳動(dòng)上導(dǎo)滑轉(zhuǎn)子上端面跳動(dòng)( (單位單位0.01mm)0.01mm)點(diǎn)號(hào)點(diǎn)號(hào)1#1#2#2#3#3#4#4

9、#5#5#6#6#7#7#8#8#數(shù)值數(shù)值0311222724154 20142014年年7 7月,在未盤車的情況下,以水導(dǎo)瓦為基準(zhǔn),將大軸推到水導(dǎo)瓦中心,月,在未盤車的情況下,以水導(dǎo)瓦為基準(zhǔn),將大軸推到水導(dǎo)瓦中心,重新調(diào)整上、下導(dǎo)瓦隙,將上、下導(dǎo)瓦隙以重新調(diào)整上、下導(dǎo)瓦隙,將上、下導(dǎo)瓦隙以0.15mm0.15mm進(jìn)行均放。開機(jī)后擺度增大,進(jìn)行均放。開機(jī)后擺度增大,水導(dǎo)瓦溫在水導(dǎo)瓦溫在6161穩(wěn)住,后緩慢下降。穩(wěn)住,后緩慢下降。 2014 2014年年1111月,對(duì)月,對(duì)2#2#機(jī)組進(jìn)行了穩(wěn)定性試驗(yàn)。機(jī)組進(jìn)行了穩(wěn)定性試驗(yàn)。(1)(1)試驗(yàn)內(nèi)容:試驗(yàn)內(nèi)容:變轉(zhuǎn)速試驗(yàn)、變勵(lì)磁試驗(yàn)、變負(fù)荷試驗(yàn)。變轉(zhuǎn)

10、速試驗(yàn)、變勵(lì)磁試驗(yàn)、變負(fù)荷試驗(yàn)。(2)(2)試驗(yàn)數(shù)據(jù):試驗(yàn)數(shù)據(jù):試驗(yàn)時(shí),上游水位為試驗(yàn)時(shí),上游水位為 1944.95m 1944.95m ,尾水水位為,尾水水位為 1700.63m 1700.63m,機(jī)組能,機(jī)組能帶帶 100% 100%額定負(fù)荷。試驗(yàn)數(shù)據(jù)詳見下圖、下表。額定負(fù)荷。試驗(yàn)數(shù)據(jù)詳見下圖、下表。擺度變化分析圖擺度變化分析圖振動(dòng)變化分析圖振動(dòng)變化分析圖測量值單位:測量值單位:mm 工況名稱工況名稱轉(zhuǎn)速轉(zhuǎn)速(rpmrpm)推擺推擺+X+X上擺上擺+Y+Y上平上平+Y+Y上垂上垂+Y+Y上平上平+X+X定平定平+Y+Y下平下平+Y+Y下平下平+X+X下擺下擺+Y+Y下擺下擺+X+X水?dāng)[水?dāng)[

11、+Y+Y水?dāng)[水?dāng)[+X+X頂平頂平+Y+Y頂垂頂垂+Y+Y尾壓尾壓脈動(dòng)脈動(dòng)初起轉(zhuǎn)39.2294.6119.71.55.93.22.33.18.374.569.139.933.86.75.614.825%nr148.5279166.71.63.22.92.33.45.557.56260.255.22.21.515.250%nr302.3379.5249.24.85.15.33.96.211.67382.7102.187.35.4213.875%nr450.6516.1360.1147.614712.422.8109.8113.8154.1131.49.12.913.8空轉(zhuǎn)601.2639.4517

12、.836.615.537.314.730.956.7160.3168.6237209.718.84.8125%ur600609530.837.614.636.413.733.960.9166.3183.1258.8235.220.75.90.850%ur598.7596.8534.737.615.136.313.934.461.2170184258.9238.421.36.9175%ur600591.5534.839.916.238.314.635.461.7176.4187.6259.323722.18.81.1空載600591.5544.340.315.537.113.337.263.81

13、86.9188.9260.4237.423.69.41.4并網(wǎng)600582.8552.442.516.137.914.639.867.4190.9203.2263.6242.225.310.11.71.5MW601.3581.155242.81637.714.439.367.1193.4194.4262.1243.424.7102.13MW600586.4559.943.315.839.514.841.171.3192.4209.7261.823725.710.11.44.5MW601.2581.155843.316.139.714.840.671.2196.7205.8264.8239.42

14、5.5102.86MW600584.7558.143.415.639.319.743.271.2190.6211.7258.7236.427.510.61.27.5MW600588.2556.843.415.539.923.343.772.4194.7213.7261.6241.828.310.82.29MW600589.6566.544.116.540.919.545.674.9193.3215.4261.7235.928.811.34.310.5MW600591569.846.816.943.418.544.879.1206.8226.1266.2215.727.710.83.812MW6

15、01.3594.1573.54816.844.217.845.281.1214.8223.5269.8208.430.211.73.413.5MW600589.1573.747.716.643.822.249.979.8214.4228269.8210.630.312.32.915MW601.3586.5564.546.416.343.220.446.178212.5219.1275.3218.528.712.3316.5MW600589.7567.344.115.641.619.641.573.5202.3215.6264.5223.224.312.51.118MW600588.9564.8

16、44.716.142.319.842.674203.6221.7264.3219.625.412.62.3河口電站河口電站2 2號(hào)機(jī)組運(yùn)行穩(wěn)定性試驗(yàn)電測結(jié)果匯總表號(hào)機(jī)組運(yùn)行穩(wěn)定性試驗(yàn)電測結(jié)果匯總表 (3)(3)試驗(yàn)結(jié)論:試驗(yàn)結(jié)論: 、機(jī)組軸線不太理想;、機(jī)組軸線不太理想; 、機(jī)組轉(zhuǎn)動(dòng)部分存在明顯失衡;、機(jī)組轉(zhuǎn)動(dòng)部分存在明顯失衡; 、機(jī)組存在輕微的磁力不平衡;、機(jī)組存在輕微的磁力不平衡; 、機(jī)組在整個(gè)帶負(fù)荷過程中,未發(fā)現(xiàn)因水力因素造成的振動(dòng)、擺度測值增大現(xiàn)、機(jī)組在整個(gè)帶負(fù)荷過程中,未發(fā)現(xiàn)因水力因素造成的振動(dòng)、擺度測值增大現(xiàn)象且未發(fā)現(xiàn)明顯的低頻水力振動(dòng)區(qū)。象且未發(fā)現(xiàn)明顯的低頻水力振動(dòng)區(qū)。(4)(4

17、)試驗(yàn)結(jié)果分析:試驗(yàn)結(jié)果分析: 由上述試驗(yàn)數(shù)據(jù)可看出,上導(dǎo)擺度無論何種工況擺度值均是最大的由上述試驗(yàn)數(shù)據(jù)可看出,上導(dǎo)擺度無論何種工況擺度值均是最大的( (推力僅供推力僅供參考),故上導(dǎo)滑轉(zhuǎn)子可能存在問題,與軸線檢查結(jié)果一致,需進(jìn)行進(jìn)一步核實(shí)。參考),故上導(dǎo)滑轉(zhuǎn)子可能存在問題,與軸線檢查結(jié)果一致,需進(jìn)行進(jìn)一步核實(shí)。預(yù)先鍛造上導(dǎo)滑轉(zhuǎn)子,粗加工后更換上導(dǎo)滑轉(zhuǎn)子,將上導(dǎo)滑轉(zhuǎn)子的緊量值由預(yù)先鍛造上導(dǎo)滑轉(zhuǎn)子,粗加工后更換上導(dǎo)滑轉(zhuǎn)子,將上導(dǎo)滑轉(zhuǎn)子的緊量值由(+0.060.10mm+0.060.10mm)增加到()增加到(+0.150.20mm+0.150.20mm),并在熱套后進(jìn)行配車,配車需要),并在熱套

18、后進(jìn)行配車,配車需要一個(gè)較大的車床,滿足磁軛直徑要求,立車更好,避免二次熱套出現(xiàn)問題。根一個(gè)較大的車床,滿足磁軛直徑要求,立車更好,避免二次熱套出現(xiàn)問題。根據(jù)下導(dǎo)滑轉(zhuǎn)子找正,將上導(dǎo)滑轉(zhuǎn)子修車好,并留有據(jù)下導(dǎo)滑轉(zhuǎn)子找正,將上導(dǎo)滑轉(zhuǎn)子修車好,并留有0.2mm0.2mm左右余量,在聯(lián)軸校左右余量,在聯(lián)軸校擺時(shí)修車。同時(shí)檢測發(fā)電機(jī)大軸各部位的形位公差符合設(shè)計(jì)要求,主要包括法擺時(shí)修車。同時(shí)檢測發(fā)電機(jī)大軸各部位的形位公差符合設(shè)計(jì)要求,主要包括法蘭、法蘭止口、法蘭外圓,上導(dǎo)下導(dǎo)滑轉(zhuǎn)子。蘭、法蘭止口、法蘭外圓,上導(dǎo)下導(dǎo)滑轉(zhuǎn)子。發(fā)電機(jī)單軸校擺后,主軸熱套推力頭等部件,裝上推力頭卡環(huán)后,將發(fā)電機(jī)主發(fā)電機(jī)單軸校擺后

19、,主軸熱套推力頭等部件,裝上推力頭卡環(huán)后,將發(fā)電機(jī)主軸與水輪機(jī)主軸在臥車上聯(lián)軸找擺,采用一卡兩托方式,按相關(guān)聯(lián)軸標(biāo)準(zhǔn)修磨軸與水輪機(jī)主軸在臥車上聯(lián)軸找擺,采用一卡兩托方式,按相關(guān)聯(lián)軸標(biāo)準(zhǔn)修磨全部跳動(dòng)到設(shè)計(jì)要求;主要包括推力頭端面、上導(dǎo)滑轉(zhuǎn)子外圓、下導(dǎo)滑轉(zhuǎn)子外全部跳動(dòng)到設(shè)計(jì)要求;主要包括推力頭端面、上導(dǎo)滑轉(zhuǎn)子外圓、下導(dǎo)滑轉(zhuǎn)子外圓及大軸聯(lián)接法蘭、水輪機(jī)大軸法蘭,水輪機(jī)與轉(zhuǎn)輪聯(lián)接止口等進(jìn)行檢測。符圓及大軸聯(lián)接法蘭、水輪機(jī)大軸法蘭,水輪機(jī)與轉(zhuǎn)輪聯(lián)接止口等進(jìn)行檢測。符合要求后,并重新鉆鉸連軸法蘭處的個(gè)徑向銷孔,重新配制銷釘。需強(qiáng)調(diào)的合要求后,并重新鉆鉸連軸法蘭處的個(gè)徑向銷孔,重新配制銷釘。需強(qiáng)調(diào)的是,端面

20、跳動(dòng)須測量軸線的正反兩面,且兩面均要符合要求(檢測值見下表)。是,端面跳動(dòng)須測量軸線的正反兩面,且兩面均要符合要求(檢測值見下表)。發(fā)電機(jī)大軸發(fā)電機(jī)大軸單軸校擺單軸校擺發(fā)電機(jī)、水發(fā)電機(jī)、水輪機(jī)大軸聯(lián)輪機(jī)大軸聯(lián)軸校擺軸校擺20152015年年2 2月,由發(fā)電機(jī)廠家對(duì)發(fā)電機(jī)大軸與水輪機(jī)大軸進(jìn)行了整體校擺。月,由發(fā)電機(jī)廠家對(duì)發(fā)電機(jī)大軸與水輪機(jī)大軸進(jìn)行了整體校擺。 點(diǎn)位 部位正面反面1234567812345678推力頭端面0000.51.5100.50-1-1010-2-0.5上導(dǎo)滑轉(zhuǎn)子00-0.5-1-1.5 -1.5-2-1.500.52-0.5-1-1.510.5下導(dǎo)滑轉(zhuǎn)子-1-1-1-0.5

21、0-0.5 -0.5 -0.500.520.51231水導(dǎo)滑轉(zhuǎn)子000.50.51-0.5 -0.5 -0.501121111水輪機(jī)發(fā)電機(jī)大軸校擺主要檢測數(shù)據(jù)水輪機(jī)發(fā)電機(jī)大軸校擺主要檢測數(shù)據(jù)單位:單位:0.01mm 0.01mm 要求不大于要求不大于0.03mm0.03mm 20152015年年4 4月,河口水電站月,河口水電站2#2#機(jī)組開機(jī)并機(jī)組開機(jī)并網(wǎng)一次成功,機(jī)組運(yùn)行穩(wěn)定,各部溫度正常,網(wǎng)一次成功,機(jī)組運(yùn)行穩(wěn)定,各部溫度正常,振擺符合要求。經(jīng)過數(shù)個(gè)月的檢查、分析、振擺符合要求。經(jīng)過數(shù)個(gè)月的檢查、分析、處理,導(dǎo)致處理,導(dǎo)致2#2#機(jī)組運(yùn)行振擺、溫度異常的主機(jī)組運(yùn)行振擺、溫度異常的主要原因

22、是:上導(dǎo)滑轉(zhuǎn)子傾斜,導(dǎo)致盤車數(shù)據(jù)要原因是:上導(dǎo)滑轉(zhuǎn)子傾斜,導(dǎo)致盤車數(shù)據(jù)不真實(shí)、軸線不合格,并由此造成軸線出現(xiàn)不真實(shí)、軸線不合格,并由此造成軸線出現(xiàn)折曲、導(dǎo)瓦間隙不對(duì)等問題。折曲、導(dǎo)瓦間隙不對(duì)等問題。處理結(jié)論 該問題普遍存在于該類型機(jī)組,在四川該問題普遍存在于該類型機(jī)組,在四川彎壩河電站也存在同樣的問題。由于過去受彎壩河電站也存在同樣的問題。由于過去受加工條件的限制,該類型機(jī)組上導(dǎo)滑轉(zhuǎn)子熱加工條件的限制,該類型機(jī)組上導(dǎo)滑轉(zhuǎn)子熱套后,進(jìn)行水輪機(jī)和發(fā)電機(jī)大軸聯(lián)軸校擺套后,進(jìn)行水輪機(jī)和發(fā)電機(jī)大軸聯(lián)軸校擺(磁軛直徑較大,熱套磁軛后需要較大的車(磁軛直徑較大,熱套磁軛后需要較大的車床校擺),合格后再將上導(dǎo)

23、滑轉(zhuǎn)子加熱取下,床校擺),合格后再將上導(dǎo)滑轉(zhuǎn)子加熱取下,熱套磁軛,再將上導(dǎo)滑轉(zhuǎn)子重新熱套,二次熱套磁軛,再將上導(dǎo)滑轉(zhuǎn)子重新熱套,二次熱套上導(dǎo)滑轉(zhuǎn)子后由于車床的限制不能二次熱套上導(dǎo)滑轉(zhuǎn)子后由于車床的限制不能二次校擺,并且上導(dǎo)滑轉(zhuǎn)子與大軸過盈配合量較校擺,并且上導(dǎo)滑轉(zhuǎn)子與大軸過盈配合量較?。ㄔ摍C(jī)型需要二次熱套),導(dǎo)致上導(dǎo)滑轉(zhuǎn)?。ㄔ摍C(jī)型需要二次熱套),導(dǎo)致上導(dǎo)滑轉(zhuǎn)子傾斜。子傾斜。 河口水電站2#機(jī)組照片0102機(jī)組軸線擺機(jī)組軸線擺度超標(biāo)原因度超標(biāo)原因和主要問題和主要問題1機(jī)組軸線擺度超標(biāo)處理過程和方法2機(jī)組軸線擺度超標(biāo)處理效果3五強(qiáng)溪保安機(jī)組軸線擺度超標(biāo)的處理五強(qiáng)溪保安機(jī)組軸線擺度超標(biāo)的處理 保安機(jī)組保安機(jī)組20162016年大修前盤年大修前盤車發(fā)現(xiàn),下導(dǎo)處擺度大,水導(dǎo)車發(fā)現(xiàn),下導(dǎo)處擺度大,水導(dǎo)處擺度嚴(yán)重超標(biāo),拆下推力頭,處擺度嚴(yán)重超標(biāo),拆下推力頭,頂軸等檢查發(fā)現(xiàn):頂軸等檢查發(fā)現(xiàn):1 1、頂軸與推力頭配合處間隙大,、頂軸與推

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

最新文檔

評(píng)論

0/150

提交評(píng)論