




版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡介
Methodandtechnicalmeasureofelectricalworks電氣主要施工方法和技術(shù)措施:A.Process施工工藝:Conduiting→cabling→installationoflightingfixtures,switches,sockets→poweronandcommisioning配管→配線→安裝燈具、開關(guān)、插座→送電調(diào)試B.Constructionnotice施工要點(diǎn):SurfacePVCconduitandpipeinceilingandrecessedPVCconduitandpipeinflooralongwallswillbeprovidedtotheproject.Conduiting,whichservestocivilworks,HVACandwatersupplyanddrainage,shouldbearrangedaccordingtodrawingsandcannotbechangedfreely.Constructionshouldcomplytoprocessstandardofnationalacceptanceregulation.本工程管線敷設(shè)為吊頂內(nèi)明敷設(shè)PVC管及電管和沿墻地坪內(nèi)暗配PVC管和電管。配管必須與土建、暖通和給排水專業(yè)密切配合,按圖施工,不得隨意變動(dòng),施工中必須按照國家驗(yàn)收規(guī)范有關(guān)工藝標(biāo)準(zhǔn)施工。Surfaceconduitandrecessedconduitwillbeadoptedintheproject.Conduitsshouldbeconnectedtightlytoassurenowaterleakage.Electricalpipeshouldbethreadconnected.Mouthofconduitshouldbesmoothandequippedwithprotectionmouth.PVCconduitshouldbeconnectedbysleevingandshouldbe1.5to3timeslongerthanexternaldiameterofconnectingconduit.本工程均為吊頂明管敷設(shè)和暗管敷設(shè)。管路連接應(yīng)牢靠,接頭嚴(yán)密,不得有滲露水現(xiàn)象。電管必須絲扣連接,管口應(yīng)光滑無毛刺,護(hù)口齊全,PVC管應(yīng)用套管連接,套管長度為連接管外徑的1.5-3倍。Bendingradiumofsurfaceconduitshouldbe4timesnolessthanitsexternaldiameterandbendingradiumofrecessedconduitshouldbe6timesnolessthanitsexternaldiameter.Thereisnoobviouswrinklecausedbybending.Surfaceconduitandsupportshouldbefixedstronglyandarrangedintoorder.Mouthofconduitshouldbelaidlevelly.Conduitshouldnotbeinsertedintoboxobliquelyandthelengthintheboxshouldbenomorethan5mm.Conduitshouldbefixedbynut.明配管R半徑不得小于外徑的4倍,暗配管彎曲半徑不得小于管外徑的6倍。管子彎曲處應(yīng)無明顯皺折。明配管及其支架應(yīng)平滑牢固,排列整齊。管口平直,管子進(jìn)入箱盒內(nèi)不得斜插,長度不得超過5毫米,用絲納子鎖固。Alltheboxesarenotallowedtoopenholesbyelectrogaswelding.各種箱盒嚴(yán)禁電氣焊開孔。Itisnotedthatboxesshouldnotbeinstalledonmarbletableandbehinddoorsandtheirheightaresameaseachother.Lightingswitchesandsocketsshouldbeinstalledatsamepositionofrooms,ofwhichtheerrorshouldbewithin2mm.各種箱盒埋設(shè)應(yīng)注意,不應(yīng)裝在大理石臺(tái)面上、標(biāo)高一致,不得裝于門后,燈具開關(guān)、插座等應(yīng)安在室內(nèi)上下同一位置,坐標(biāo)的誤差不得大于2毫米。Steelframeorspecialhangerframeshouldbestrengthenedforinstallationoflightingonceiling.Lightingfixturesshouldbeinstalledwithoutgapatjointandtheywillbekeptclean.吊頂上的燈具安裝應(yīng)加強(qiáng)龍骨框架或?qū)S玫跫堋艟甙惭b無縫隙,內(nèi)外清潔。Switchcontrolsneutralline,andphaselineofscrewholderisconnectedtopower.Leftpointofsocketshouldbeconnectedtoneutralline,rightpointtophaselineandupperpointtoearth.Heightoflightshouldbelowerthan2.4m,andthemetalshellshouldbeconnectedtoearthwell.Lightswitches,socketsshouldbefixedwithoutdamageanddeforming.開關(guān)應(yīng)控制相線,螺口燈頭相線接頂心,插頭安裝接線為面對(duì)插座左零右相上接地。燈具安裝底于2.4米,其金屬外殼必須可靠接地。燈具開關(guān)、插座安裝牢固,無損傷變形等。PowerDBshouldbeinstalledsecurelyatrightpositionwithallparts.Theholesshouldbeopenedproperlyontheboxandprohibittoopenholesbyelectrogaswelding.Theconduitinsideboxshouldbelevelandfixedbynut.Screwshouldbeconnectedtoearthwelland2to4piecesofitcanbeoutside.配電箱安裝位置正確,部件齊全,安裝牢固。箱體開孔適當(dāng)、嚴(yán)禁電氣焊開孔,進(jìn)入箱體的管口平齊,用納子鎖牢固,絲扣外露2-4扣為宜,接地可靠。Boxshouldbecleaninsideandoutsidewithgoodpainting.Wiresshouldbearrangedintoorderandbounded.Connectionofwiresshouldberightandfixed,meanwhile,sparewiresshouldbekept.Numberofcardshouldbecompleted.Theboxesshouldbeinstalledwitherrornomorethan1.5mm.箱體應(yīng)內(nèi)外清潔,油漆完整。導(dǎo)線成束整齊,連接線路正確牢固,留有適當(dāng)余線,卡片框編號(hào)齊全,箱體安裝橫平豎直,允許偏差不大于1.5毫米。Jointandconnectionofwiresinsideconduitisnotallowedwhentheyarethreadedthroughconduit.Strandedcoppercoreshouldbeconnectedtoequipments.Wireslessthan6mm2canbeputlikeshapeofscreweyeandthencoatedbytin.Single-strandedcoppercorecanbeprovidedfireretardantsafetywirejointortincoat.Bobbinusedbywirejointshouldbecrimpingtoolsof3pointcrimpingtype.Tincoatshouldbesmooth,nodamagetoinsulatedlayerofwire.Colorofwirethreadedthroughconduit:phaselineisyellowandgreen;singlephaseisred;neutralisblue;earthinglineistwo-tonecoloredwireofyellowandgreen.管內(nèi)穿線嚴(yán)禁在管內(nèi)接頭,導(dǎo)線有連接,多股銅芯線應(yīng)用銅線與設(shè)備連接,6平方毫米以下可做“羊眼圈”狀再刷錫。單股銅芯線可采用阻燃型安全壓線帽或刷錫。壓線帽使用的壓線軸必須是專用配套的“三點(diǎn)抱壓式”壓接鉗。刷錫應(yīng)飽滿、光滑、無損傷導(dǎo)線絕緣層。穿線時(shí)的導(dǎo)線色標(biāo)為:相線為黃、綠色;單相用紅色為宜;零線為單蘭色;接地線為黃、綠雙色線。Compensatingunitshouldbeprovidedwhenwiresthreadthroughsettlementjointandexpansionjointofbuilding.Insulationresistancebetweenwireandearthshouldbenolessthan0.5ΩM.電氣管線穿過建筑物的沉降和伸縮縫采用補(bǔ)償裝置。導(dǎo)線之間對(duì)地的絕緣電阻不能小于0.5ΩM。Materialsandequipmentstobeusedshouldbeprovidedwithtexturespecificationandcertificateofqualification.對(duì)所有使用材料設(shè)備等要有材質(zhì)證明和產(chǎn)品合格證書方可使用。Constructionworkersshouldbeprovidedtrainingaboutsecurityandtechnology.Electricianshouldhavequalifiedlicense.對(duì)施工人員要進(jìn)行安全和技術(shù)培訓(xùn),電氣作業(yè)人員必須持證上崗。Installationofcommonlightingfixtures普通燈具安裝:1、Lightingfixturesshouldbefixedaccordingtofollowingregulations燈具的固定應(yīng)符合下列規(guī)定:(1)、Whentheweightoflightismorethan3kg,itshouldbefixedbyscreworembeddedliftinghook.燈具重量大于3KG時(shí),固定在螺栓或預(yù)埋吊鉤上。(2)、Whenweightofsoftcorelightislessthan0.5kg,itshouldbehungbyitssoftwire.Whentheweightofsoftcorelightisover0.5kg,itwillhungbyslingchainwithsoftwireinsideitsothatthewirewillbefreefromforce.軟線吊燈,燈具重量在0.5KG以下時(shí),采用軟電線自身吊裝,大于0.5KG的燈具采用吊鏈,且軟電線編叉在吊鏈內(nèi),使電線不受力。(3)、Lightingfixtureshouldnotbefixedbywoodscrew.Screwsorboltsusedtofixlightingfixturesshouldbenolessthan2pieces.Wheninsulatedradiumislessthan75mm,lightingfixtureshouldbefixedbyonescreworbolt.燈具固定牢靠,不準(zhǔn)使用木鍥。每個(gè)燈具固定用螺釘或螺栓不少于2個(gè),當(dāng)絕緣臺(tái)徑在75mm及以下時(shí),采用一個(gè)螺釘或螺栓固定。(4)、Diameterofroundsteelofflowerlight’shanginghookshouldbenolessthanthatofhangertenonand6mm.Testofinstallinglighttwiceheavierthanflowerlightshouldbedonebeforeinstallationoflargeflowerlight.花燈吊鉤圓鋼直徑不應(yīng)小于燈具掛銷直徑,且不應(yīng)小于6mm。大型花燈的固定及懸吊裝置,應(yīng)按燈具重量的2倍做過載試驗(yàn)。(5)、Whensteelpipeisusedaslamppost,interiordiametershouldbenolessthan10mmandthicknessnolessthan1.5mm.當(dāng)鋼管做燈桿時(shí),鋼管內(nèi)徑不應(yīng)小于10mm,鋼管厚度不應(yīng)小于1.5mm。2、Whenheightoflightingfixtureislessthan2.4m,lightingfixtureshouldbeconnectedtoearthwellwithspecialearthingboldandmarks.當(dāng)燈具距地面高度小于2.4M時(shí),燈具必須接地(PE)可靠,并應(yīng)有專業(yè)的接地螺栓,且有標(biāo)識(shí)。3、Shell,lampholderandwireconnectionoflightingfixtureshouldcomplytorequirementsgoesasfollows.燈具的外性、燈頭及其接線應(yīng)符合下列要求。(1)、Lightingfixturewithfullparts,nodamageordeformationandnodefectsofcoatsflakingofforlampshadetears.燈具及其配件齊全,無機(jī)械損傷、變形、圖層剝落和燈罩破裂等缺陷。(2)、Protectionjointshouldbeprovidedonthebothendofsoftwireofhanginglight.Corewireofbothendshouldbecoatedtin.Plasticsofttubeandsafetylampholdershouldbeusedduringriserinstallation.軟線吊燈的軟線兩端做保護(hù)扣,兩端芯線搪錫,當(dāng)裝升降器時(shí),套塑料軟管,采用安全燈頭。(3)、Insulatedshelloflightholderisnotdamagedandelectricityleakage.Thehandleofswitchhasnometalpartexposedinair.燈頭的絕緣外殼不破損和漏電,帶有開關(guān)的燈頭。開關(guān)手柄無裸露的金屬部分。4、LightshouldnotbeinstalledoverHV&LVpowerdistributionequipmentsandscrewwireinsubstation.變電所內(nèi),高低壓配電設(shè)備及螺母線的正上方不應(yīng)安裝燈具。5、Baseandsupportofspotlightshouldbefixedstrongly.Kingjournalshouldbescrewedupandfixedinrayaxisdirection.投光燈的底座及支架應(yīng)固定牢固,樞軸應(yīng)沿需要的光軸方向擰緊固定。6、Exteriorwallfittingshouldbeprovidedwaterdischarginghole.Waterproofdeviceshouldbeprovidedtoinsulationtableandwall.安裝在室外的壁燈應(yīng)有泄水孔,絕緣臺(tái)與墻面之間應(yīng)有防水措施。Speciallightinstallation專用燈具安裝:Lightinstallationshouldcomplytofollowingrequirements:燈具安裝應(yīng)符合下列規(guī)定:(1)、Besidesnormalpower,anothersparepowerorpowerproducedbydieseloilgeneratororaccumulatorwillbeprovidedtoemergencylight.Emergencylightwithitsownpowerisanotherchoice.應(yīng)急照明燈的電源除正常電源外,另有一路電源供電;或者是獨(dú)立于正常電源的柴油發(fā)電機(jī)組供電;或由蓄電池柜供電或選用自帶電源型應(yīng)急燈具;(2)、Escapelightingconsistsofexitlightandescapelegend.Heightofexitlightisnolessthan2mandshouldbeinstalledatescapingexitandupperpartsofstaircase.疏散照明由安全出口標(biāo)志燈和疏散標(biāo)志燈組成。安全出口標(biāo)志燈距地高度不低于2m,且安裝在疏散出口和樓梯口里側(cè)的上方;(3)、Escapelegendshouldbeinstalledonthetopofsafeexitandwithin1monthewallofstaircase,escapingcorridorandcorner.Itcanbeinstalledontheupperpartwhentheplaceisnoteasytoinstall.Distancebetweenescapelegendoverescapecorridorshouldbenomorethan20m(distanceincivildefenceshouldbenomorethan10m)疏散標(biāo)志燈安裝在安全出口的頂部,樓梯間、疏散走道及其轉(zhuǎn)角處應(yīng)安裝在1m以下的墻面上。不易安裝的部位可安裝在上部。疏散通道上的標(biāo)志燈間距不大于20m(人防工程不大于10m);(4)、Positionofescapelegendshouldassurepassingsmoothlyandwillnotbeconfusedbyothermarks.疏散標(biāo)志燈的設(shè)置,不影響正常通行,且不在其周圍設(shè)置容易混同疏散標(biāo)志燈的其它標(biāo)志牌等;(5)、Separateemergencylightcircuitshouldexistinemergencylightwiring.Wirepassthroughdifferentfirepreventareasshouldbeprovidedfirepreventionmesure.應(yīng)急照明線路在每個(gè)防火分區(qū)有獨(dú)立的應(yīng)急照明回路,穿越不同防火分區(qū)的線路有防火隔堵措施;(6)、Fire-resistingwire,cablewillbeusedasescapinglightwiring.Wirewillthreadsurfaceconduitorrecessedrigidconduitinsideinflammablematerial.Thicknessofprotectionlayershouldbenomorethan30mm.Coppercoreinsulatedwirewithratevoltagenolessthan750Vwillbeused.疏散照明線路采用耐火電線、電纜,穿管明敷或在非燃燒體內(nèi)穿剛性導(dǎo)管暗敷,暗敷保護(hù)層厚度不小于30mm。電線采用額定電壓不低于750V的銅芯絕緣電線。Poweronandtestrunoflighting照明通電試運(yùn)行:1、ControloflightingcircuitshouldbesameasmarksoflightingpowerDBwhenlightingsystemispoweron.Switchshouldmatchsequenceoflightingfixturecontrol.Directionturnandspeedregulatingswitchoffanshouldworkwell.照明系統(tǒng)通電,燈具回路控制應(yīng)與照明配電箱及回路的標(biāo)識(shí)一致;開關(guān)與燈具控制順序相對(duì)應(yīng),風(fēng)扇的轉(zhuǎn)向及調(diào)速開關(guān)應(yīng)正常。2、Powershouldbe24hsuppliedtolightingsystemofpublicbuildingand8hsuppliedtocivilbuilding.Alllightfittingshouldbepoweronandrecordshouldbetakenevery2h.Thereshouldbenofaultsincontinuousrunning.公用建筑物照明系統(tǒng)通電連續(xù)運(yùn)行時(shí)間應(yīng)為24h,民用住宅照明系統(tǒng)通電連續(xù)運(yùn)行時(shí)間應(yīng)為8h。所有照明燈具均應(yīng)開啟,且每2h記錄運(yùn)行狀態(tài)1次,連續(xù)運(yùn)行時(shí)間內(nèi)無故障。Installationofswitchesandsockets開關(guān)、插座安裝一、Wiringofsocketshouldcomplytofollowingregulations插座接線應(yīng)符合下列規(guī)范:1、Leftpoleandupperpoleofsinglephase2polesocketshouldconnecttophaselineandrightpoleandunderpoleshouldconnecttoneutral;rightpoleofsinglephase3polesocketshouldconnecttophaselineandleftpoleshouldconnecttoneutralline.單相兩插座,面對(duì)插座的右孔或上孔相線連接,左孔或下孔與零線連接;單相三孔插座,面隊(duì)插座的右孔與相線連接,左孔與零線連接;2、PEorPENlineshouldconnecttoupperpoleofsinglephase3polesocket,3phase4polesocketand3phase6polesocket.Earthingconnectorofsocketwillnotconnecttoneutralconnector.3phasesocketatthesameplaceconnectwiresinsameway.單相三孔、三相四孔及三相五孔插座的接地(PE)或接零(PEN)線接在上孔。插座的接地端子不與零線端子連接。同一場(chǎng)所用的三相插座,接線的相序一致;3、PEorPENlineisnotallowedtoconnectinseriesbetweensockets.接地(PE)或接零(PEN)線在插座間不串聯(lián)連接;4、Recessedsocketpanelsticktowalltightlywithoutgaparoundit.Surfaceofitissmooth,nocracks,scratchedandwithalldecoratedbolt.暗裝的插座面板緊貼墻面,四周無縫隙,安裝牢固,表面光滑整潔、無碎裂、劃傷,裝飾帽齊全;5、Floorsocketpanelisparalleltofloororsticktofloortightly.Coverisfixedtightlyandsealed.地插座面板與地面齊平或緊貼地面,蓋板固定牢固,密封良好;6、Heightofsocketsinsameroomshouldbesame.同一室內(nèi)插座安裝高度一致。二、Installationoflightingswitchesshouldcomplytofollowingregulations照明開關(guān)安裝應(yīng)符合下列規(guī)定:(1)、Switchesinonebuildingshouldchooseoneseriesofproducts.Switchesingoodconditionshouldbesameandcontroleasily.同一建筑物、構(gòu)筑物的開關(guān)采用同一系列的產(chǎn)品,開關(guān)的通斷位置一致,操作靈活、接觸可靠;(2)、Locationofswitchesshouldbeeasytouse.Edgeofswitchshouldbe0.15~0.2mawayfromdoorframeand1.3mawayfromfloor.Ceilingswitchshouldbe2~3mfromfloor,however,whentheheightofroomislessthan3m,ceilingswitchshouldbeawayfromceilingnolessthan100mmandtheswitchshouldbedownwardvertically.開關(guān)安裝位置便于操作,開關(guān)邊緣距門框邊緣的距離0.15~0.2m,開關(guān)距地面高度1.3m;拉線開關(guān)距地面高度2~3m,層高小于3m時(shí),拉線開關(guān)距頂板不小于100mm,拉線出口垂直向下;(3)、Switchesofsametypeshouldbeinstalledtogetherandheightshouldbesameinoneroom.Controlofswitchshouldbeinorder.Ceilingswitchofparallelinstallationshouldbemorethan20mmawayfromeachother.相同型號(hào)并列安裝及同一室內(nèi)開關(guān)高度一致,且控制有序不錯(cuò)位。并列安裝的拉線開關(guān)的相鄰間距不小于20mm;(4)Recessedsocketpanelsticktowalltightlywithoutgaparoundit.Surfaceofitissmooth,nocracks,scratchedandwithalldecoratedbolt.暗裝的開關(guān)面板應(yīng)緊貼墻面,四周無縫隙,安裝牢固、表面光滑整潔、無碎裂、劃傷,裝飾帽齊全。Indoorwatersupplysystem室內(nèi)給水系統(tǒng)Pipesconnectingwatertankinbasementandconnectingpumpsandwatertankonroofarecompositemetalplasticpipesandthreadedconnection.OtherpipesarePP-Rpipeandpipefittingswiththermalconnection.PP-Rpipeandpipefittingshouldbe2.0MPapipes.地下室水箱間與生活泵至屋頂水箱之管材采用鋼塑復(fù)合管及管件絲扣連接;其余給水管材均采用PP-R管及管件,熱熔連接。PP-R管及管件選用2.0MPa管材。InteriorwatersupplyvalvewhoseDN>50shouldbebutterflyvalveorgatevalve.ValvewhoseP=1.0MPaandDN≤50shouldbeballvalve.室內(nèi)給水閥門DN>50采用蝶閥或閘閥,P=1.0MPa;DN≤50采用球閥。lPipesinoutdoorceilingshouldbepolyurethaneflexiblepipeinsulatedbyaluminumfoil.Thicknessofinsulatedlayer:whenDN>50,itshouldbe40mm;whenDN≤50,itshouldbe30mm.DetailsrefertoO3S401and87S159.吊頂室內(nèi)外,屋頂外露部分管道采用聚氨脂軟管外包夾筋鋁箔保溫,保溫層厚度:當(dāng)DN>50時(shí)為40mm;當(dāng)DN≤50時(shí)為30mm。做法詳見O3S401,87S159。Testpressureofdomesticwatersupplyshouldbe1.1MPa;Watersupplyforfirefightingshouldbe1.2MPa.生活給水管的試驗(yàn)壓力為1.1MPa;消防給水管的試驗(yàn)壓力為1.2MPa。Firehydrantsystemandsprinklingsystemshouldbeconnectedbygalvanizedsteelpipeofthreadedconnection.Slopeoftransversesprinklingpipeshouldbe0.2%,andpipeshouldbewaterreleaseriser.SprinklerheadshouldbeconnectedbyDN25.Pressuregaugewillbeputinfrontofwaterreleasevalve.Installationofwet-testalarmvalvereferstocollectivedrawings89SS175ofnationalstandard89SS175.消火栓系統(tǒng)與噴淋系統(tǒng)管材采用熱鍍鋅鋼管絲扣連接。噴淋橫管坡度為0.2%,坡向放水立管。噴頭連接支管為DN25,放水閥前設(shè)壓力表。濕試報(bào)警閥安裝詳見國標(biāo)圖集89SS175。Installationofvalveshouldcomplytoitem3.2.4and3.2.5inGB50242-2002.閥門安裝應(yīng)按《GB50242-2002》規(guī)范第;3.2.5條規(guī)定安裝。Installationofwatersupplypipeshouldcomplytoitem;4.1.7;4.1.8;4.2.2;4.2.6;4.2.7inGB50242-2002.給水管道安裝應(yīng)按《GB50242-2002》規(guī)范第;4.1.7;4.1.8;4.2.2;4.2.6;4.2.7條規(guī)定安裝。Installationofindoorfirehydrantshouldcomplytoitem;4.3.2;4.3.3inGB50242-2002.室內(nèi)消火栓安裝應(yīng)按《GB50242-2002》規(guī)范第;4.3.2;4.3.3條規(guī)定安裝。Installationofconnectorofpipesshouldcomplytoitem3.3.15inGB50242-2002.管道接口應(yīng)符合《GB50242-2002》規(guī)范第條規(guī)定安裝。Installationofhangingsupportofpipesshouldcomplytoitem;3.3.8inGB50242-2002.管道吊支架安裝應(yīng)符合《GB50242-2002》規(guī)范第;3.3.8條規(guī)定安裝。Installationofwatersupplypipeandfittingsshouldcomplytoitem;4.2.2;4.2.3;4.2.4;4.2.5;4.2.6inGB50242-2002.給水管道及配件安裝應(yīng)符合《GB50242-2002》規(guī)范第;4.2.2;4.2.3;4.2.4;4.2.5;4.2.6條規(guī)定安裝。Indoorwaterdrainagesystem室內(nèi)排水系統(tǒng)WaterdrainagesystemshouldbeconnectedbyPVC-Upipesandpipefittingsinadhesivesway.DownpipewhichisusedPVC-UdownpipeandfittingshouldbeconnectedbyrubberringofR-Rpipesocket.Waterdrainagerisershouldbeconnectedwithwaterdrainagepipeby2elbowsof45°.排水管材采用PVC-U排水管及管件粘接連接;雨水管采用PVC-U雨水管及管件,R-R承口橡膠圈連接,排水立管與排出管間連接采用兩個(gè)45度彎頭。Wateringtestshouldbedonebeforewaterdrainagepipeisembedded.Heightofwatershouldbenotlowerthanupperedgeof1Fsanitaryorheightoffloor.Checkingmethod:afterwatersurfacefallsdownafter15minoffullwater,fillupwateragainandobserveitfor5min,ifwatersurfacedoesnotfallnot,noleakageofpipeandjointwillbeaccepted.隱蔽式埋地的排水管道在隱蔽前必須做灌水試驗(yàn),其灌水高度應(yīng)不低于底層衛(wèi)生器具的上邊緣或地面高度。檢驗(yàn)方法:滿水15min水面下降后,再灌滿觀察5min,液面不降,管道及接口無滲漏為合格。Slopeofplastictransversepipefordomesticwasterwater.生活污水塑料管道橫管坡度:Caliber管徑(mm)StandarddSloppe標(biāo)準(zhǔn)坡度(‰)MinSloppe最小坡度(‰)5025127515811012616074Expansionjointshouldbeinstalledonplasticwaterdrainagepipeaccordingtodesignbriefanditsposition.Expansionjointswithintervalnomorethan4MwillbeprovidedwithfireprotectionzoneorfireproofcoversIntervalbetweens
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 跨區(qū)域醫(yī)療救治合同
- 土地臨時(shí)占用合同書
- 藥品供應(yīng)鏈合作協(xié)議合同模板
- 戰(zhàn)略合并合同協(xié)議書
- 快遞企業(yè)間互惠合同
- 14 文言文二則 學(xué)弈 教學(xué)設(shè)計(jì)-2024-2025學(xué)年語文六年級(jí)下冊(cè)統(tǒng)編版
- 度杭州XX樓盤住房公積金貸款業(yè)務(wù)合作合同
- 環(huán)保監(jiān)測(cè)設(shè)備供應(yīng)合同
- 企業(yè)合作伙伴保密合同協(xié)議
- 9《作息有規(guī)律》教學(xué)設(shè)計(jì)-2024-2025學(xué)年道德與法治一年級(jí)上冊(cè)統(tǒng)編版
- 校本教材(生活中的物理)
- 第一章 體育與健康理論知識(shí) 課件 2023-2024學(xué)年人教版初中體育與健康七年級(jí)全一冊(cè)
- 心臟起搏器植入指南
- 物理學(xué)科中的跨學(xué)科應(yīng)用
- 專題07 二次函數(shù)與幾何圖形綜合問題(復(fù)習(xí)講義)(原卷版)-二輪要點(diǎn)歸納與典例解析
- 高中語文統(tǒng)編版(部編版)必修下冊(cè)第六單元 大單元公開課一等獎(jiǎng)創(chuàng)新教學(xué)設(shè)計(jì)
- 初三化學(xué)學(xué)情分析
- 人教版新教材高一上學(xué)期期末考試數(shù)學(xué)試卷及答案(共五套)
- TB10092-2017 鐵路橋涵混凝土結(jié)構(gòu)設(shè)計(jì)規(guī)范
- 化工原理-第三章-過濾課件
- 2023年通遼市中考數(shù)學(xué)試卷及答案
評(píng)論
0/150
提交評(píng)論