干式一體化地面輻射供冷供暖技術(shù)規(guī)程目次總則 1術(shù)語 2設(shè)計 5般定 5面造 5間負與負算 6面熱的算 7系設(shè)計 9控熱量 104材料 12般定 12塊溫板與熱料 12飾層粘層料 13熱材料 13系材料 13控置 145施工 15般定 15式體化地輻冷供系施方案 16制槽溫模設(shè) 17熱冷系的工 17層粘層工 18品護 19驗、試運維 20般定 20量收 21壓驗 21試檢測 22行理 22護保養(yǎng) 23附錄A 24附錄B 26附錄C 40本標用說明 42引用準錄 43條文明 46ContentsGeneralProvisions 1Terms 2Design 5GeneralRequirements 5FloorStructure 5RoomHeatingLoadandCoolingLoadCalculation 6FloorHeatTransferCalculation 7WaterSystemDesign 9TemperatureControlandHeatingMetering 10Materials 12GeneralRequirements 12ModuleInsulationBoardandHeatDistributionCourseMaterial 12DecorativeSurfaceLayerandAdhesiveLayerMaterial 13InsulationMaterial 13WaterSystemMaterial 13TemperatureControlEquipment 14Construction 15GeneralRequirements 15ConstructionSchemeofDryIntegrationFloorRadiantCoolingandHeatingSystem 16Pro-groovedInsulationBoardModuleLaying 17ConstructionofHeatingandCoolingPipeSystem 17SurfaceLayerConstruction 18TheFinishedProjectProtection 19Acceptance,Debugging,Maintenance 20GeneralRequirements 20QualityAcceptance 21HydrostaticTesting 21DebuggingandTesting 22OperationManagement 22Maintenance 23AppendixA 24AppendixB 26AppendixC 40ExplanationofWordinginThisStandard 42ListofQuotedStandards 43ExplanationofProvisions 44PAGEPAGE41總則技術(shù)先進、經(jīng)濟合理、安全適用和保證工程質(zhì)量,制定本規(guī)程。射供冷供暖系統(tǒng)工程的設(shè)計、施工、調(diào)試及運維等。程外,尚應(yīng)符合國家及行業(yè)現(xiàn)行有關(guān)標準的規(guī)定。術(shù)語干式一體化地面輻射供冷供暖系統(tǒng)prefabricatedfloorradiantcoolingandheatingsystem冷供暖系統(tǒng)。pre-groovedinsulationboardmodule模塊保溫板,上鋪均熱層。heatdistributioncourse或非金屬導熱層。pipeandwiredetachedfromskeleton建筑結(jié)構(gòu)體中不埋設(shè)設(shè)備及管線,將設(shè)備及管線與建筑結(jié)構(gòu)體相分離的方式。干式工法non-wetconstruction指現(xiàn)場采用干作業(yè)施工工藝的建造方法。adhesioncourse用于粘結(jié)石材、地磚等面層與預制溝槽保溫板模塊的膠粘劑形成的薄層。decorativesurfacecourse建筑地面與室內(nèi)空氣直接接觸的構(gòu)造層,包括石材、地磚及木地板等。cushioncourse平整度等作用。moisturebarriercourse防止建筑地基或土壤的潮氣透過地面的構(gòu)造層。isolatingcourse防止建筑地面上各種液體透過地面的構(gòu)造層,也稱防水層。insulatingcourse獨鋪設(shè)的構(gòu)造層。waterdistributionmanifold,watercollectionmanifold用于連接集中供冷供暖系統(tǒng)的供水管或回水管和各供熱供冷管分支環(huán)路的配水和匯水裝置。watermixingdevice置。thermostat控制方式的不同主要分為室溫型、地溫型和雙溫型溫控器。predictedmeanvoteofthermalsensation(PMV)平均指數(shù)。operativetemperature在實際非均勻環(huán)境的換熱量相同,也稱為操作溫度。dewpointtemperature在恒定氣壓條件下進行冷卻時,空氣中的蒸汽壓飽和,相對濕度達到100%時的溫度。thermalresponsetime95%所消耗的時間,用來表征輻射末端動態(tài)響應(yīng)的快慢。設(shè)計一般規(guī)定干式一體化地面輻射供暖系統(tǒng)的供、回水溫度應(yīng)由計算確定,供水溫度宜35℃~45601053.1.1的要求。表3.1.1地面輻射供暖表面平均溫度(℃)區(qū)域特征適宜范圍最高限值人員長期停留區(qū)域25~2729人員短期停留區(qū)域28~3032無人員停留區(qū)域35~4042干式一體化地面輻射供冷系統(tǒng)應(yīng)結(jié)合除濕系統(tǒng)或新風系統(tǒng)進行設(shè)計,供水溫度應(yīng)高于室內(nèi)空氣露點溫度1℃~2℃,供回水溫差不宜大于5221℃。45min。宜選用熱泵機組或熱回收裝置。0.6MPa。及電氣管線等應(yīng)采用管線分離方式進行綜合設(shè)計。干式一體化地面輻射供冷供暖系統(tǒng)工程應(yīng)提供建筑負荷計算書、系統(tǒng)施工JGJ142的相關(guān)要求。地面構(gòu)造干式一體化地面輻射供冷供暖地面的構(gòu)造做法應(yīng)根據(jù)其設(shè)置位置確定,不A列全部或部分組成:樓板或與土壤相鄰的地面;防潮層(對與土壤相鄰地面);絕熱層;墊層;模塊保溫板;均熱層;供熱供冷管隔離層(對潮濕房間);粘結(jié)層;裝飾面層。供冷供暖輻射地面構(gòu)造應(yīng)符合下列規(guī)定:保溫板與土壤之間應(yīng)設(shè)置防潮層;設(shè)置絕熱層;潮濕房間地面面層下應(yīng)設(shè)置隔離層。管;與供冷供暖區(qū)域連接時,應(yīng)采取保溫措施或敷設(shè)在保溫板上。固措施。房間熱負荷與冷負荷計算用建筑供暖通風及空氣調(diào)節(jié)設(shè)計規(guī)范》GB50736的有關(guān)規(guī)定進行計算。干式一體化地面輻射供冷供暖系統(tǒng)設(shè)計時應(yīng)以室內(nèi)體感溫度作為室內(nèi)設(shè)計溫度,按表3.3.2選擇確定。表3.3.2人員長期逗留區(qū)域室內(nèi)設(shè)計溫度(℃)熱舒適度等級供熱工況供冷工況平均熱感覺指數(shù)室內(nèi)體感溫度平均熱感覺指數(shù)室內(nèi)體感溫度Ⅰ級-0.5≤PMV≤022℃~24℃0≤PMV≤0.524℃~26℃Ⅱ級-1≤PMV<-0.518℃~22℃0.5<PMV≤126℃~28℃3.3.3系數(shù)的方法確定。表3.3.3局部輻射供暖熱負荷計算系數(shù)供暖區(qū)面積與房間總面積的比值≥0.750.550.400.25≤0.20計算系數(shù)10.720.540.380.30鋪設(shè)供熱供冷管的建筑地面,不應(yīng)計算地面?zhèn)鳠嵝纬傻睦錈嶝摵伞?.3.5計算。QQjqhM式中Q——房間熱負荷(W);Qj——3.3.1~3.3.4計算出的房間基本熱負荷(W);
(3.3.5-1)α——1.31.4~1.51.0。qh——房間單位面積平均戶間傳熱量(W/m2),可取qh=7W/m2;M——房間使用面積(m2)。地面?zhèn)鳠崃康挠嬎愕孛婀┡簆j q2t tpj
(3.4.1-1)地面供冷:
q7tpjtn
(3.4.1-2)式中:q——單位地面面積向上的傳熱量(W/m2);tpj——地表面平均溫度(℃);tn——室內(nèi)設(shè)計溫度(℃)。房間所需單位地面面積向上傳熱量應(yīng)按下式計算:q=Q1
(3.4.2-1)1 FQ1QQ2
(3.4.2-2)式中:q1——房間所需單位地面面積向上的傳熱量(W/m2);Q1——房間所需地面向上的傳熱量(W);F——房間內(nèi)鋪設(shè)供熱供冷管的地面面積(m2);β——考慮家具等遮擋的安全系數(shù);Q——按3.3節(jié)計算出的房間熱負荷或冷負荷(W);Q2——自上層房間地面向下的傳熱量(W)。.3計算。當?shù)乇砻嫫骄鶞囟扔嬎阒颠^高或過低時,可通過設(shè)置其他供冷供暖設(shè)備、改變室內(nèi)設(shè)計溫度等措施調(diào)整地表面平均溫度。地面供暖:
q 0.909tpjtn8.92
(3.4.3-1)地面供冷:
tpj
qtn7
(3.4.3-2)式中:tpj——地表面平均溫度(℃);tn——室內(nèi)設(shè)計溫度(℃);q——單位地面面積向上的傳熱量(W/m2)。輻射供冷供暖地面向上傳熱量和向下傳熱量應(yīng)通過計算確定。當輻射供冷本規(guī)程附錄B確定。熱量和向下傳熱量或向土壤的傳熱損失。水系統(tǒng)設(shè)計分戶獨立式供冷供暖系統(tǒng)應(yīng)設(shè)置脫氣除污器。戶內(nèi)系統(tǒng)的供回水溫度、壓力和資用壓差等參數(shù)與冷熱源不匹配時,應(yīng)根應(yīng)采用共用立管的分戶獨立系統(tǒng)形式;3戶;共用立管應(yīng)設(shè)置在戶外公共空間的管道井內(nèi);要時設(shè)置的熱交換器或混水裝置。的需求;系統(tǒng)定壓值應(yīng)符合供熱供冷管的承壓要求。應(yīng)按下列原則設(shè)置分水器、集水器的分支環(huán)路或管徑確定;配管可以串聯(lián);配置獨立的環(huán)路。面向上傳熱量、室內(nèi)設(shè)計溫度、平均水溫等確定。0.25m/s。分水器、集水器直徑應(yīng)不小于總供回水管直徑,且最大斷面流速不宜大于0.8m/s。每個主分支環(huán)路均應(yīng)可單獨關(guān)斷。分水器前應(yīng)設(shè)置過濾器;分水器、集水器上應(yīng)設(shè)置手動或自動排氣閥。工安裝》12K404,供冷時應(yīng)采取防結(jié)露措施。3.6溫控與熱計量熱計量技術(shù)規(guī)程》JGJ173的規(guī)定。射供冷宜能實現(xiàn)氣候補償,自動控制供水溫度。干式一體化地面輻射供冷供暖室溫控制可采用分環(huán)路控制和總體控制兩種方式,作法參考《地面輻射供暖供冷系統(tǒng)施工安裝》12K404。自動控制閥宜采用電熱式控制閥,也可采用自力式溫控閥和電動兩通閥,并應(yīng)符合下列規(guī)定:動控制閥,控制各房間或區(qū)域的室內(nèi)溫度;個用戶或區(qū)域的室內(nèi)溫度。1.4m,或與照明開關(guān)在同一水平線上。人員經(jīng)常停留的位置且在模塊保溫板表面的均熱層上。在需要同時控制室溫和限制地表面溫度的場合應(yīng)采用雙溫型溫控器。度傳感器探測并計算露點的方法。材料一般規(guī)定200kpa瓷磚》GB/T4100,根據(jù)屋內(nèi)實際荷載選用高破壞強度地磚。綜合比較后確定。干式一體化地面輻射供冷供暖系統(tǒng)中所使用的材料均應(yīng)符合國家現(xiàn)行相關(guān)模塊保溫板與均熱層材料殖菌源,不得散發(fā)異味及可能危害健康的揮發(fā)物。GB/T10801.1、GB/T10801.2GB/T21558的規(guī)定。4.2.34.2.34.2.3規(guī)定采用熱阻相同原理進行換算。表4.2.3模塊保溫板最小熱阻及鋁制均熱板最小厚度設(shè)備類型保溫板總厚度最小熱阻(m2﹒K/W)鋁制均熱板最小厚度(mm)管間距<200mm管間距≥200mm管外徑(mm)120.85161.0201.15模塊保溫板的溝槽尺寸應(yīng)與敷設(shè)的均熱板溝槽外徑相吻合。均熱板溝槽的65%裝飾面層與粘結(jié)層材料材料膠粘劑中有害物質(zhì)限量》GB18583規(guī)定的要求。5mm0.4MPa。以木地板作為裝飾地面時,木地板的性能要求應(yīng)符合現(xiàn)行國家標準《地暖GB/T35913LY/T的規(guī)定。絕熱層材料4.4.1與土壤接觸的底層為輻射供冷供暖地面時,模塊保溫板的最小熱阻應(yīng)在表4.2.3的基礎(chǔ)上增加0.5m2﹒K/W。4.4.2直接與室外空氣接觸的樓板為輻射供冷供暖地面時,設(shè)置的絕熱層熱阻不1.0m2﹒K/0.75m2﹒K/W。水系統(tǒng)材料供熱供冷管(含復合管)應(yīng)滿足設(shè)計使用壽命、施工和環(huán)保性能要求,并應(yīng)符合下列規(guī)定:材和管件》GB/T18991中的4級;供熱供冷管的工作壓力不應(yīng)大于0.6MPa;管道質(zhì)量必須符合國家現(xiàn)行相應(yīng)標準中的各項規(guī)定與要求;供熱供冷管宜使用帶阻氧層的管材。GB/T29730中的要求。溫控裝置記清晰、面板扣合自如、溫度調(diào)節(jié)部件使用正常。供水溫度控制用自動調(diào)節(jié)閥應(yīng)符合相關(guān)產(chǎn)品標準的規(guī)定。施工一般規(guī)定術(shù)資格。的設(shè)計變更文件,并經(jīng)原工程設(shè)計單位批準后方可施工。施工安裝前應(yīng)具備下列條件:施文件應(yīng)齊全并已完成技術(shù)交底;材料進場檢驗應(yīng)己合格并滿足安裝要求;施工現(xiàn)場應(yīng)具有供水或供電條件,應(yīng)有儲放材料的臨時設(shè)施;士建專業(yè)應(yīng)已完成墻面抹灰(不含面層),畢,地面應(yīng)己清理干凈,衛(wèi)生間應(yīng)做完閉水試驗并應(yīng)經(jīng)過驗收;相關(guān)電氣預埋等工程應(yīng)已完成;50應(yīng)采取升溫措施,但不得采用明火。預制溝槽保溫板模塊和供熱供冷管的運輸、存儲應(yīng)符合下列規(guī)定:應(yīng)進行遮光包裝后運輸,不得裸露散裝;運輸、裝卸和搬運時,應(yīng)小心輕放,不得拋、摔、滾、拖;40房內(nèi);應(yīng)避免因環(huán)境溫度和物理壓力受到損害,并應(yīng)遠離熱源。塊及供熱供冷管的表面。施工時不宜與其他工種交叉施工作業(yè),所有地面留洞應(yīng)在模塊鋪設(shè)施工前完成。且應(yīng)干燥、無雜物、無積灰、無損傷;墻面根部應(yīng)平直,且無積灰現(xiàn)象。集水器。施工過程中,預制溝槽保溫板模塊等供熱供冷管敷設(shè)區(qū)域,嚴禁穿鑿、穿供熱供冷管造成損傷。當供熱供冷管道固定于梁柱等鋼構(gòu)件上時,應(yīng)采用絕熱支架。施工結(jié)束后應(yīng)繪制竣工圖,應(yīng)準確標注供熱供冷管敷設(shè)位置。干式一體化地面輻射供冷供暖系統(tǒng)施工方案施工單位應(yīng)編制施工組織設(shè)計或施工方案,經(jīng)批準后方可施工。施工組織設(shè)計或施工方案應(yīng)包括下列內(nèi)容:工程概況;施工節(jié)點圖、原始工作面至面層的剖面圖的位置等;主要材料、設(shè)備的性能技術(shù)指標、規(guī)格、型號等及保管存放措施;施工工藝流程及各專業(yè)施工時間計劃;環(huán)路、系統(tǒng)試運行調(diào)試,竣工驗收等;施工進度計劃、勞動力計劃;安全、環(huán)保、節(jié)能技術(shù)措施。地面輻射供冷供暖系統(tǒng)所使用的主要材料、設(shè)備組件、配件、預制溝槽保供熱供冷管、輸配管及管件進場,應(yīng)由供冷供暖工程的施工單位對管材壁干式一體化地面供冷供暖系統(tǒng)各部件進場后由供冷供暖工程的施工單位會的有關(guān)規(guī)定。閥門、分水器和集水器組件安裝前,應(yīng)做強度和嚴密性試驗。試驗應(yīng)在每10%通管上的旁通閥門,應(yīng)逐個做強度和嚴密性試驗,合格后方可使用。1.5倍;嚴密性試驗壓力應(yīng)為工作壓力的1.150mm的閥門強度和嚴密性試驗持續(xù)時間應(yīng)為15s預制溝槽保溫板模塊鋪設(shè)應(yīng)在模塊鋪設(shè)前鋪設(shè)防潮層。塊上的供熱供冷管位置應(yīng)互相對應(yīng),緊密依靠。帶木龍骨的預制溝槽保溫板模塊鋪設(shè)時,應(yīng)在安裝木龍骨后鋪設(shè)標準模塊筑標準設(shè)計圖集《地面輻射供暖系統(tǒng)施工安裝》12K404。供熱供冷管系統(tǒng)的施工供熱供冷管敷設(shè)前應(yīng)對照施工圖紙核定供熱供冷管的選型、管徑、璧厚符合設(shè)計要求;應(yīng)檢查供熱供冷管外觀質(zhì)量和管內(nèi)部無雜質(zhì),確認后方可施工。入模塊中溝槽;供熱供冷管安裝完畢或中斷時,敞口處應(yīng)隨時封堵。供熱供冷管切割,應(yīng)采用專用工具;切口應(yīng)平整,斷口面應(yīng)垂直管軸線。其溝槽走向安裝管路。敷設(shè)在地面面層下的供熱供冷管不應(yīng)有接頭。采取絕熱措施。分水器、集水器宜在開始鋪設(shè)供熱供冷管之前進行安裝。水平安裝時,宜將分水器安裝在上,集水器安裝在下,中心距宜為200mm300mm。面層和粘接層施工面層施工應(yīng)具備下列條件:供熱供冷盤管安裝完畢,驗收合格;供熱供冷管水壓試驗合格且處于有壓狀態(tài);溫控器安裝盒穿管己布置完畢;已通過干式一體化地面輻射供冷供暖系統(tǒng)安裝工程驗收。10mm地板鋪設(shè)時,應(yīng)留不小于14mm縫填充材料宜采用高發(fā)泡聚乙烯泡沫塑料。木質(zhì)地板鋪設(shè)技術(shù)和驗收規(guī)范》WB/T1037的有關(guān)規(guī)定。面層可按下列方法施工:可發(fā)性聚乙烯(EPE)墊層應(yīng)鋪設(shè)在模塊之下,不得鋪設(shè)在模塊之上;結(jié)層將石材或面磚粘結(jié)。專業(yè)做防水。供熱供冷管穿止水墻處應(yīng)采取隔離措施。成品保護防止鋪裝面層時造成損壞。保護層可采用透氣性強的無紡布(丙綸布)、亞克力板、膠合板等材料。保護層鋪裝需平整嚴密,邊角及接縫宜用膠帶固定,不得翹起移動。強度的保護層等方法,有效防止對模塊保溫板及供熱部件造成損傷。損壞,保證供冷供暖系統(tǒng)的安全可靠運行。驗收、調(diào)試及運維一般規(guī)定C格式。業(yè)技術(shù)資格。干式一體化地面輻射供冷供暖系統(tǒng)應(yīng)對下列內(nèi)容進行檢查和驗收:備等的質(zhì)量;工質(zhì)量;管道、分水器、集水器、閥門和溫控及計量設(shè)備等安裝質(zhì)量;隱蔽前、后水壓試驗;管路沖洗;系統(tǒng)試運行??⒐を炇諘r,應(yīng)提供下列文件:施工圖、竣工圖和設(shè)計變更文件;主要設(shè)備和管材、配件等主要材料的出廠合格證及檢驗報告;中間驗收記錄;沖洗和試壓記錄;工程質(zhì)量檢驗評定記錄;系統(tǒng)調(diào)試和試運行記錄;現(xiàn)場見證復驗材料和產(chǎn)品的檢驗報告;地面輻射供冷供暖系統(tǒng)性能檢測報告;工程使用維護說明書。質(zhì)量驗收有關(guān)人員進行中間驗收。干式一體化地面輻射供冷供暖系統(tǒng)中間驗收時,應(yīng)符合下列規(guī)定:預制溝槽保溫板模塊的厚度、材料的物理性能及鋪設(shè)應(yīng)符合設(shè)計要求;供熱供冷管、供熱電纜的材料、規(guī)格及敷設(shè)間距、彎曲半徑、固定措施等應(yīng)符合設(shè)計要求;供冷供暖地面構(gòu)造按要求設(shè)置;伸縮縫應(yīng)按設(shè)計要求敷設(shè)完畢;地面面層范圍內(nèi)供熱供冷管不應(yīng)有接頭,彎曲部分不得出現(xiàn)硬折彎現(xiàn)象;閥門啟閉靈活,關(guān)閉嚴密;面層平整,表面無明顯裂縫。伸縮縫位置出壁面位置的套管應(yīng)有固定措施。偏差滿足《輻射供暖供冷技術(shù)規(guī)程》JGJ142的要求。水壓試驗水壓試驗程序應(yīng)符合下列規(guī)定:主供、回水管道沖洗合格后,再進行室內(nèi)供暖系統(tǒng)的沖洗;水壓試驗應(yīng)以每組分水器、集水器為單位,逐回路進行;水壓試驗之前,對試壓管道和構(gòu)件應(yīng)采取安全有效的固定和保護措施;冬季進行水壓試驗時,在有凍結(jié)可能的情況下.應(yīng)采取可靠的防凍措施;試壓完成后應(yīng)及時將管內(nèi)的水吹凈、吹干。1.50.6MPa1h0.05MPa調(diào)試與檢測干式一體化地面輻射供冷供暖系統(tǒng)未經(jīng)調(diào)試,嚴禁運行使用。和供電的條件下,由施工單位在建設(shè)單位配合下進行。初始供暖時,供暖系統(tǒng)的供水溫度應(yīng)控制在設(shè)計供水溫度,并保持該溫度進行調(diào)節(jié),直至達到設(shè)計要求。初始供冷調(diào)試應(yīng)在除濕系統(tǒng)或新風系統(tǒng)調(diào)試后進行,供冷系統(tǒng)的供水溫度124h管逐路進行調(diào)節(jié),直至達到設(shè)計要求。測,并應(yīng)符合下列規(guī)定:3.1.13.1.2條的規(guī)定;室內(nèi)溫度滿足設(shè)計要求;干式一體化地面輻射供冷供暖系統(tǒng)進出口水溫度及溫差滿足設(shè)計要求。價依據(jù)。運行管理干式一體化地面輻射供冷供暖系統(tǒng)在冬季運行管理過程中,要時刻注意天統(tǒng)不被凍結(jié)。運行時預開關(guān)機等控制。干式一體化地面輻射供冷供暖系統(tǒng)應(yīng)設(shè)置聯(lián)動控制,確保系統(tǒng)高效運行。維護與保養(yǎng)干式一體化地面輻射供冷供暖系統(tǒng)首次運行前注水時應(yīng)充分排氣。系統(tǒng)每管進回水放氣通暢,供熱供冷管內(nèi)無氣堵。滿水保護。在有凍結(jié)可能的地區(qū)應(yīng)排水。洞、釘鑿、撞擊、高溫作業(yè)等工作。A
干式一體化地面輻射供冷供暖地面構(gòu)造圖示地磚、石材均熱層冷熱水管墊層樓板圖A.1-1與供暖房間相鄰的干式一體化地面輻射供冷供暖地面構(gòu)造(地磚或石材面層) 模塊保溫板墊層樓板圖A.1-2與供暖房間相鄰的干式一體化地面輻射供冷供暖地面構(gòu)造(木地板面層)地磚、石材粘結(jié)層模塊保溫板冷熱水管墊層樓板圖A.2-1與室外空氣或不供暖房間相鄰的干式一體化地面輻射供冷供暖地面構(gòu)造(地磚或石材面層)樓板圖A.2-2與室外空氣或不供暖房間相鄰的干式一體化地面輻射供冷供暖地面構(gòu)造(木地板面層)粘結(jié)層隔離層冷熱水管圖A.3-1與土壤相鄰的干式一體化地面輻射供冷供暖地面構(gòu)造(地磚或石材面層)冷熱水管防潮層圖A.3-2與土壤相鄰的干式一體化地面輻射供冷供暖地面構(gòu)造(木地板面層)B
干式一體化地面輻射供冷供暖地面單位面積傳熱量表B.1.1石材、地磚面層單位地面面積的供熱量和熱損失量(W/m2)(公稱外徑10mm)供回水平均溫(℃)供熱管間距(mm)25020015010050供熱量熱損失量供熱量熱損失量供熱量熱損失量供熱量熱損失量供熱量熱損失量301848.56.553.87.355.27.662.98.870.110.32040.45.56.452.47.458.48.62232.34.435.94.95.946.76.92424.23.326.93.627.63.831.44.435.05.1351868.79.376.210.378.210.889.012.599.214.62060.68.29.678.611.087.612.927.959.88.368.19.675.911.22444.46.049.36.750.67.09.4401888.812.098.713.4101.114.0115.216.2128.418.92080.810.989.712.291.912.7104.814.7116.717.22272.79.880.711.082.711.594.313.3105.115.52464.68.771.79.773.510.283.811.893.413.74518109.014.7121.116.4124.117.2141.419.9157.623.220101.013.6112.115.2114.915.9131.018.4145.921.52292.912.5103.114.0105.714.6120.516.9134.319.82484.811.594.212.896.513.4110.015.5122.618.05018129.217.5143.519.5147.120.420.423.6186.827.520121.116.4134.518.3137.919.19.922.1175.125.822113.115.3125.617.0128.717.8-0.620.6163.424.124105.014.2116.615.8119.516.6-11.019.2151.822.35518149.420.2165.922.5170.123.6193.827.3216.031.820141.319.1157.021.3160.922.3183.325.8204.330.122133.318.0148.020.1151.721.0172.924.3192.628.324125.216.9139.018.9142.519.7162.422.8181.026.6注:計算條件為:10mm0.38W/(m﹒k);0.02m2﹒K/W;1.0W/(m﹒k)1mm;0.035W/(m﹒k)25mm;)2mm;1.72W/(m﹒k)130mm。表B.1.2石材、地磚面層單位地面面積的供熱量和熱損失量(W/m2)(公稱外徑12mm)供回水平均溫(℃)供熱管間距(mm)25020015010050供熱量熱損失量供熱量熱損失量供熱量熱損失量供熱量熱損失量供熱量熱損失量301848.65.754.06.455.56.763.17.870.29.12040.54.845.05.346.25.652.66.558.57.62232.43.836.04.337.04.56.12424.32.927.031.63.935.14.5351889.411.099.413.02060.87.267.58.069.48.478.99.787.711.42252.76.258.56.960.17.368.48.476.09.9245.950.96.28.3401889.110.598.911.7101.712.3115.714.3128.716.82081.09.590.010.692.511.2105.213.0117.015.22272.98.681.09.611.7105.313.72464.87.672.08.574.09.084.110.493.612.24518109.412.9121.414.4124.915.1142.017.5157.920.620101.311.9112.413.3115.614.0131.516.2146.219.12293.211.0103.512.2106.412.9121.014.9134.517.52485.110.094.511.297.111.8110.413.6122.816.05018129.715.3143.917.0148.017.9168.320.8187.124.420121.614.3134.916.0138.716.8157.819.5175.422.922113.513.4125.914.9129.515.7147.318.2163.721.324105.412.4117.013.8120.214.6136.716.9152.019.85518149.917.6166.419.7171.120.7194.624.0216.428.220141.816.7157.418.6161.919.6184.122.7204.726.722133.715.7148.417.6152.618.5173.621.4193.025.124125.614.8139.416.5143.417.4163.020.1181.323.6注:計算條件為:12mm0.38W/(m﹒k);0.02m2﹒K/W;1.0W/(m﹒k)1mm;0.035W/(m﹒k)30mm;)2mm;1.72W/(m﹒k)130mm。表B.1.3石材、地磚面層單位地面面積的供熱量和熱損失量(W/m2)(公稱外徑16mm)供回水室內(nèi)設(shè)供熱管間距(mm)300250200150100供熱量熱損失量供熱量熱損失量供熱量熱損失量供熱量熱損失量供熱量熱損失量301844.44.55.756.16.063.67.02037.03.841.046.85.053.05.82229.63.032.83.436.43.837.44.042.44.72422.22.324.62.527.32.828.13.031.83.5351862.96.469.77.277.38.079.58.590.29.92055.55.761.56.37.579.68.82248.14.953.35.56.568.97.6244.650.058.36.4401881.48.390.29.3100.010.4102.911.0116.712.92074.07.682.08.490.99.493.610.0106.111.72266.66.873.87.681.88.584.29.095.510.5246.872.77.574.88.084.99.4451899.910.2110.711.4122.712.7126.313.5143.215.82092.59.5102.510.5113.611.8117.012.5132.614.62285.18.794.39.7104.510.8107.611.5122.013.42477.78.086.18.995.59.998.210.5111.412.35018118.412.1131.213.5145.415.1149.716.1169.718.720111.011.4123.012.7136.414.1140.415.1159.117.522103.610.6114.811.8127.313.2131.014.1148.516.42496.29.8106.611.0118.212.3121.613.0137.915.25518136.914.0151.715.6168.217.4173.118.6196.321.620129.513.3143.514.8159.116.5163.717.6185.620.522122.112.5135.313.9150.015.6154.416.6175.019.324114.711.7127.113.1140.914.6145.015.6164.418.1注:計算條件為:16mm0.38W/(m﹒k);0.02m2﹒K/W;1.0W/(m﹒k)1mm;0.035W/(m﹒k)35mm;)2mm;1.72W/(m﹒k)130mm。表B.1.4石材、地磚面層單位地面面積的供熱量和熱損失量(W/m2)(公稱外徑20mm)供回水室內(nèi)設(shè)供熱管間距(mm)300250200150100供熱量熱損失量供熱量熱損失量供熱量熱損失量供熱量熱損失量供熱量熱損失量301846.64.351.44.756.75.358.05.665.26.62038.83.642.94.047.24.448.34.754.35.52231.02.83.538.73.843.44.4242.428.32.629.02.832.63.3351866.06.072.96.780.37.582.28.092.39.32058.25.364.35.970.96.68.22250.54.65.77.12442.73.947.24.352.04.853.25.259.76.0401885.47.894.38.7103.99.7106.410.3119.512.0207.994.58.896.79.4108.610.92269.96.47.987.08.597.79.82462.15.768.66.375.67.077.37.586.98.74518104.89.6115.710.7127.511.9130.512.7146.614.82097.18.9107.29.9118.111.0120.911.8135.813.72289.38.298.69.1108.610.1111.210.8124.912.62481.57.590.08.399.29.2101.59.9114.011.55018124.211.4137.212.7151.214.1154.715.1173.817.520116.510.7128.611.9141.713.2145.014.1162.916.422108.710.0120.011.1132.312.3135.413.2152.015.324100.99.2111.510.3122.811.5125.712.2141.214.25518143.613.2158.614.6174.816.3178.917.4200.920.220135.912.5150.013.8165.315.4169.216.5190.119.122128.111.7141.513.0155.914.5159.515.5179.218.024120.311.0132.912.3146.413.7149.914.6168.316.9注:計算條件為:20mm0.38W/(m﹒k);0.02m2﹒K/W;1.0W/(m﹒k)1mm;0.035W/(m﹒k)40mm;)2mm;1.72W/(m﹒k)130mm。表B.2.1木地板面層單位地面面積的供熱量和熱損失量(W/m2)(公稱外徑10mm)供回水室內(nèi)設(shè)供熱管間距(mm)25020015010050供熱量熱損失量供熱量熱損失量供熱量熱損失量供熱量熱損失量供熱量熱損失量30187.99.247.710.52030.16.032.76.633.36.836.87.739.78.72224.14.826.25.326.65.57.02418.03.619.64.020.023.85.3351851.110.355.611.256.611.662.513.167.614.82045.19.049.09.949.910.355.211.559.613.12239.17.842.58.643.38.947.810.051.711.42433.16.636.040.58.543.79.6401866.213.371.914.573.215.080.916.987.419.22013.266.613.773.515.479.517.52254.210.958.911.959.912.366.213.871.515.72448.19.652.310.553.310.958.812.363.614.0451881.216.388.317.889.918.599.320.7107.323.62016.519.299.421.82269.213.975.215.276.615.784.617.791.420.12463.212.768.713.869.914.418.3501896.319.3104.621.1106.521.9117.724.6127.227.92090.399.920.5110.323.0119.226.22284.216.991.618.493.219.1103.021.5111.324.52478.215.785.017.186.617.895.620.0103.322.75518111.322.3121.024.4123.225.3136.028.4147.132.320105.321.1114.423.1116.523.9128.726.9139.130.52299.319.9107.921.7109.922.6121.325.3131.228.82493.318.7101.420.4103.221.2114.023.8123.227.1注:計算條件為:10mm0.38W/(m﹒k);0.1m2﹒K/W;0.035W/(m﹒k)25mm;)2mm;1.72W/(m﹒k)130mm。表B.2.2木地板面層單位地面面積的供熱量和熱損失量(W/m2)(公稱外徑12mm)供回水平均溫(℃)供熱管間距(mm)25020015010050供熱量熱損失量供熱量熱損失量供熱量熱損失量供熱量熱損失量供熱量熱損失量301836.16.439.36.92030.15.332.75.833.46.036.86.839.87.724.626.74.829.55.431.86.2243.520.13.64.6351851.29.055.69.856.810.262.611.567.613.22045.27.949.18.750.19.055.310.259.711.62239.26.942.57.543.47.847.98.851.710.02433.15.836.06.436.86.640.57.543.88.5401866.311.672.012.773.513.381.114.987.517.02060.210.665.411.666.812.073.713.679.615.52254.29.558.910.460.110.866.312.271.613.92448.28.552.49.353.59.659.010.863.712.4451881.314.388.315.690.216.399.518.3107.420.92075.313.281.814.583.599.419.32269.312.275.313.376.813.984.815.691.517.82463.311.168.712.270.212.677.414.283.516.2501896.416.9104.718.5106.919.3117.921.7127.324.82090.415.998.217.4100.218.1110.620.3119.323.22284.314.891.616.293.616.9103.219.0111.421.72478.313.885.115.086.915.795.817.6103.420.15518111.419.6121.121.4123.622.3136.325.1147.228.620105.418.5114.520.3116.921.1129.023.7139.227.12299.417.5108.019.1110.319.9121.622.4131.325.52493.416.4101.417.9103.618.7114.221.0123.324.0注:計算條件為:12mm0.38W/(m﹒k);0.1m2﹒K/W;0.035W/(m﹒k)30mm;)2mm;1.72W/(m﹒k)130mm。表B.2.3木地板面層單位地面面積的供熱量和熱損失量(W/m2)(公稱外徑16mm)供回水平均溫(℃)供熱管間距(mm)300250200150100供熱量熱損失量供熱量熱損失量供熱量熱損失量供熱量熱損失量供熱量熱損失量30185.66.444.57.32028.04.330.44.733.037.16.12222.43.424.33.74.329.74.92416.82.618.22.835187.956.18.710.32042.06.445.67.049.57.79.12236.45.56.643.97.048.27.92430.84.75.637.15.940.86.7401861.59.467.010.372.611.274.211.881.613.42055.98.560.99.366.010.267.510.774.212.12250.37.754.88.459.49.260.79.766.810.92444.76.848.77.58.659.49.7451875.511.582.212.689.113.891.114.5100.216.42069.910.776.111.782.512.884.313.492.715.22264.39.870.010.775.911.777.612.385.314.02458.79.063.99.869.310.770.911.377.912.8501889.513.697.414.9105.616.3108.017.2118.719.42083.912.891.314.099.015.3101.216.1111.318.22278.311.914.394.515.0103.917.02472.785.813.387.714.096.515.85518103.515.8112.617.3122.118.9124.819.9137.322.52097.914.9106.516.3115.517.9118.118.8129.821.32292.314.1100.415.4108.916.8111.317.7122.420.02486.713.294.314.5102.315.8104.616.6115.018.8注:計算條件為:16mm0.38W/(m﹒k);0.1m2﹒K/W;0.035W/(m﹒k)35mm;)2mm;1.72W/(m﹒k)130mm。表B.2.4木地板面層單位地面面積的供熱量和熱損失量(W/m2)(公稱外徑20mm)供回水平均溫(℃)供熱管間距(mm)300250200150100供熱量熱損失量供熱量熱損失量供熱量熱損失量供熱量熱損失量供熱量熱損失量301834.94.75.741.56.045.36.82029.14.031.54.334.04.734.65.037.85.623.527.23.827.74.030.24.52417.42.418.92.620.42.820.73.022.73.4351849.46.753.67.357.88.058.88.564.29.62043.65.947.36.551.056.68.425.66.549.17.32432.04.334.74.75.541.56.2401864.08.769.39.574.810.476.110.983.112.42058.27.963.08.668.09.469.29.975.511.327.861.28.562.38.968.010.12446.56.350.46.954.47.555.38.060.49.0451878.510.785.111.691.812.793.413.4101.915.22072.79.978.810.885.011.886.512.494.414.1229.978.210.879.611.486.812.92461.08.39.972.610.479.311.8501893.012.6100.813.8108.815.1110.715.9120.818.02087.211.994.512.9102.014.1103.814.9113.316.92281.495.213.296.913.9105.715.82475.610.381.911.288.412.289.912.998.214.65518107.614.6116.616.0125.817.4128.018.4139.720.820101.813.8110.315.1119.016.5121.117.4132.119.72296.013.0104.014.2112.215.5114.216.4124.618.62490.112.397.713.4105.414.6107.215.4117.017.4注:計算條件為:20mm0.38W/(m﹒k);0.1m2﹒K/W;0.035W/(m﹒k)40mm;)2mm;1.72W/(m﹒k)130mm。表B.3.1石材、地磚面層單位地面面積的供冷量和熱損失量(W/m2)(公稱外徑10mm)供回水平均溫(℃)供熱管間距(mm)25020015010050供冷量熱損失量供冷量熱損失量供冷量熱損失量供冷量熱損失量供冷量熱損失量172423.04.325.24.725.74.928.75.631.36.42629.65.56.38.22836.26.839.67.440.47.745.08.849.210.019243.418.43.520.54.022.34.62623.04.325.24.725.74.928.75.631.36.42829.65.56.38.221249.91.810.82.011.013.42.7263.418.43.520.54.022.34.62823.04.325.24.725.74.928.75.631.36.4230.9269.91.810.82.011.013.42.7283.418.43.520.54.022.34.6注:計算條件為:10mm0.38W/(m﹒k);0.02m2﹒K/W;1.0W/(m﹒k)1mm;0.035W/(m﹒k)25mm;)2mm;1.72W/(m﹒k)130mm。表B.3.2石材、地磚面層單位地面面積的供冷量和熱損失量(W/m2)(公稱外徑12mm)供回水平均溫(℃)供熱管間距(mm)25020015010050供冷量熱損失量供冷量熱損失量供冷量熱損失量供冷量熱損失量供冷量熱損失量172423.23.74.328.84.931.35.62629.84.832.55.333.35.537.06.340.37.22836.45.939.76.540.76.745.27.749.28.9192416.52.718.12.93.522.44.02623.23.74.328.84.931.35.62829.84.832.55.333.35.537.06.340.37.221249.91.610.81.811.11.82.42616.52.718.12.93.522.44.02823.23.74.328.84.931.35.6230.8269.91.610.81.811.11.82.42816.52.718.12.93.522.44.0注:計算條件為:12mm0.38W/(m﹒k);0.02m2﹒K/W;1.0W/(m﹒k)1mm;0.035W/(m﹒k)30mm;)2mm;1.72W/(m﹒k)130mm。表B.3.3石材、地磚面層單位地面面積的供冷量和熱損失量(W/m2)(公稱外徑16mm)供回水室內(nèi)設(shè)供熱管間距(mm)300250200150100供冷量熱損失量供冷量熱損失量供冷量熱損失量供冷量熱損失量供冷量熱損失量172421.43.023.43.325.53.626.23.829.04.42627.63.84.633.74.937.35.62833.74.75.741.16.045.66.819242.318.22.618.72.720.73.12621.43.023.43.325.53.626.23.829.04.42827.63.84.633.74.937.35.621249.21.310.01.410.91.511.21.612.41.9262.318.22.618.72.720.73.12821.43.023.43.325.53.626.23.829.04.4230.6269.21.310.01.410.91.511.21.612.41.9282.318.22.618.72.720.73.1注:計算條件為:16mm0.38W/(m﹒k);0.02m2﹒K/W;1.0W/(m﹒k)1mm;0.035W/(m﹒k)35mm;)2mm;1.72W/(m﹒k)130mm。表B.3.4石材、地磚面層單位地面面積的供冷量和熱損失量(W/m2)(公稱外徑20mm)供回水平均溫(℃)供熱管間距(mm)300250200150100供冷量熱損失量供冷量熱損失量供冷量熱損失量供冷量熱損失量供冷量熱損失量172422.42.824.33.026.43.326.93.529.64.02628.83.631.33.933.94.334.64.538.05.22835.24.438.34.85.646.56.3192416.02.02.419.22.521.12.92622.42.824.33.026.43.326.93.529.64.02828.83.631.33.933.94.334.64.538.05.2211.311.31.411.51.512.71.72616.02.02.419.22.521.12.92822.42.824.33.026.43.326.93.529.64.0230.621.311.31.411.51.512.71.72816.02.02.419.22.521.12.9注:計算條件為:20mm0.38W/(m﹒k);0.02m2﹒K/W;1.0W/(m﹒k)1mm;0.035W/(m﹒k)40mm;)2mm;1.72W/(m﹒k)130mm。表B.4.1木地板面層單位地面面積的供冷量和熱損失量(W/m2)(公稱外徑10mm)供回水平均溫(℃)供熱管間距(mm)25020015010050供冷量熱損失量供冷量熱損失量供冷量熱損失量供冷量熱損失量供冷量熱損失量172418.04.622.94.65.727.86.12623.25.929.45.925.36.627.77.335.87.9287.231.043.79.6192412.93.316.43.314.13.74.42618.04.622.94.65.727.86.12823.25.929.45.925.36.627.77.335.87.921247.72.09.82.02.411.92.62612.93.316.43.314.13.74.42818.04.622.94.65.727.86.1230.9267.72.09.82.02.411.92.62812.93.316.43.314.13.74.4注:計算條件為:10mm0.38W/(m﹒k);0.1m2﹒K/W;0.035W/(m﹒k)25mm;)2mm;1.72W/(m﹒k)130mm。表B.4.2木地板面層單位地面面積的供冷量和熱損失量(W/m2)(公稱外徑12mm)供回水平均溫(℃)供熱管間距(mm)25020015010050供冷量熱損失量供冷量熱損失量供冷量熱損失量供冷量熱損失量供冷量熱損失量172418.14.019.44.319.84.521.65.023.05.7265.625.55.827.76.429.67.32828.46.330.56.87.936.28.9192412.92.916.54.12618.14.019.44.319.84.521.65.023.05.7285.625.55.827.76.429.67.3212.42612.92.916.54.12818.14.019.44.319.84.521.65.023.05.7230.822.42812.92.916.54.1注:計算條件為:12mm0.38W/(m﹒k);0.1m2﹒K/W;0.035W/(m﹒k)30mm;)2mm;1.72W/(m﹒k)130mm。表B.4.3木地板面層單位地面面積的供冷量和熱損失量(W/m2)(公稱外徑16mm)供回水室內(nèi)設(shè)供熱管間距(mm)300250200150100供冷量熱損失量供冷量熱損失量供冷量熱損失量供冷量熱損失量供冷量熱損失量17243.519.63.820.04.021.74.5264.525.24.95.7285.530.86.031.46.334.17.0192412.12.313.02.514.02.714.32.815.53.2263.519.63.820.04.021.74.5284.525.24.95.7211.92612.12.313.02.514.02.714.32.815.53.2283.519.63.820.04.021.74.5230.621.92812.12.313.02.514.02.714.32.815.53.2注:計算條件為:16mm0.38W/(m﹒k);0.1m2﹒K/W;0.035W/(m﹒k)35mm;)2mm;1.72W/(m﹒k)130mm。表B.4.4木地板面層單位地面面積的供冷量和熱損失量(W/m2)(公稱外徑20mm)供回水平均溫(℃)供熱管間距(mm)300250200150100供冷量熱損失量供冷量熱損失量供冷量熱損失量供冷量熱損失量供冷量熱損失量172417.53.03.520.43.722.04.12622.53.84.526.34.728.35.32827.54.75.532.15.834.66.519242.314.42.514.62.615.72.92617.53.03.520.43.722.04.12822.53.84.526.34.728.35.3211.8262.314.42.514.62.615.72.92817.53.03.520.43.722.04.1230.621.8282.314.42.514.62.615.72.9注:計算條件為:20mm0.38W/(m﹒k);0.1m2﹒K/W;0.035W/(m﹒k)40mm;)2mm;1.72W/(m﹒k)130mm。
工程質(zhì)量驗收表表C干式一體化地面輻射供冷供暖系統(tǒng)安裝工程質(zhì)量驗收表工程名稱分部(子分部)工程名稱驗收單位施工單位項目經(jīng)理分包單位分包項目經(jīng)理專業(yè)工長(施工員)施工班組長施工執(zhí)行標準名稱及編號《干式一體化地面輻射供冷供暖系統(tǒng)技術(shù)規(guī)程》CECS2021項目序號內(nèi)容檢驗依據(jù)施工單位評定檢查記錄監(jiān)理(建設(shè))單位驗收記錄主控項目1外徑及壁厚設(shè)計要求4.5.12模塊保溫板、均熱層厚度設(shè)計要求4.2.32供熱供冷管水壓試驗6.3一般項目1分集水器安裝3.5.8-.6、5.4.7、2防潮層、隔離層鋪設(shè)3.2.1、3.2.2、5.3.1、5.5.53絕熱層鋪設(shè)4.4.1、4.4.24預制模塊鋪設(shè)5.3.1~5.3.35模塊接縫4.2.4、5.3.26伸縮縫設(shè)置5.5.2施工單位檢查評定結(jié)果項目專業(yè)質(zhì)量檢查員年月日監(jiān)理(建設(shè))單位驗收結(jié)論監(jiān)理工程師:(建設(shè)單位項目專業(yè)技術(shù)負責人)年月日本標準用詞說明為便于在執(zhí)行本標準條文時區(qū)別對待,對要求嚴格程度不同的用詞說明如下:正面詞采用“應(yīng)”;反面詞采用“不應(yīng)”或“不得”;正面詞采用“宜”,反面詞采用“不宜”;“可”。應(yīng)按……執(zhí)行或應(yīng)符合……規(guī)定”。引用標準名錄1《裝配式建筑評價標準》GB/T511292《民用建筑供暖通風及空氣調(diào)節(jié)設(shè)計規(guī)范》GB507363《輻射供暖供冷技術(shù)規(guī)程》JGJ1424《輻射供冷及供暖裝置熱性能測試方法》JGT4035《冷熱水用分集水器》GB/T297306《冷熱水系統(tǒng)用熱塑性塑料管材和管件》GB/T189917《供熱計量技術(shù)規(guī)程》JGJ1738《地面輻射供暖供冷系統(tǒng)施工安裝》12K4049《木質(zhì)地板鋪裝、驗收和使用規(guī)范》GB/T2023810《地暖用實木地板技術(shù)要求》GB/T35913干式一體化地面輻射供冷供暖技術(shù)規(guī)程條文說明目次1總則 462術(shù)語 473設(shè)計 503.1般定 50間負與負算 52面熱的算 53系設(shè)計 53控熱量 534材料 55般定 55塊溫與熱料 56飾層粘層料 56熱材料 575施工 58般定 58式體化地輻統(tǒng)施方案 58塊溫鋪設(shè) 58熱冷系的工 58層工 59品護 596驗、試運維 59試檢測 59行理 59護保養(yǎng) 59總則本條說明了制定本標準的目的和意義。本規(guī)程中的干式一體化地面輻射供冷供暖系統(tǒng)為采用管線分離方式設(shè)計及干式工法施工的地面輻射供冷供暖系統(tǒng)形式。本條規(guī)定了本規(guī)程的適用范圍。適用于一般的民用與工業(yè)建筑。同其他標準規(guī)范銜接。術(shù)語為了滿足《裝配式建筑評價標準》GB/T51129射供冷供暖系統(tǒng)應(yīng)采用管線分離方式進行設(shè)計及干式工法進行施工。板上鋪設(shè)有與供熱供冷管外徑尺寸相同溝槽的高導熱材料制成的均熱層。200W/m﹒K。管線分離是建筑結(jié)構(gòu)體中不埋設(shè)設(shè)備及管線,將設(shè)備與管線與建筑結(jié)構(gòu)體((不含橫穿管線分離沿墻邊預留布管,消除了管道交叉隱患。干作業(yè)指在現(xiàn)場不使用攪拌砂漿或其它帶水作業(yè)的工作項目。一般采用界面劑或瓷磚粘貼劑作為粘結(jié)劑。2.0.8由于干式一體化地面輻射供冷供暖系統(tǒng)采用干式工法施工,在裝飾面層下若分滲入且滿足地面平整度要求時,可取消墊層。2.0.11求與土壤接觸的底層應(yīng)提高模板保溫板的厚度,從而減少房間散熱損失。本條文參考了國家標準《民用建筑室內(nèi)熱濕環(huán)境評價標準》GBT50785-2012和《室內(nèi)熱環(huán)境條件》GB/T5701-2008。PMV(P.Fanger)教授提出的表征人體熱舒適的評價指標,代表了同一環(huán)境中大多數(shù)(3(2(1性0、稍暖(1、暖(2、熱(3平均值,計算如下式所示。
t ta+tr(1)op 2式中ta是房間中心0.6m(坐姿)或1.1m(站姿)處的室內(nèi)空氣溫度,tr是房間中心0.6m或1.1m處平均輻射溫度。按照國內(nèi)外室內(nèi)熱環(huán)境標準規(guī)定,平均輻射溫度可以通過測試黑球溫度、空氣溫度及空氣速度進行計算得到,相關(guān)測試方法可以參考國家標準《民用建筑室內(nèi)熱濕環(huán)境評價標準》GBT50785-2012和《室內(nèi)熱環(huán)境條件》GB/T5701-2008。此外,參考ASHRAE手冊,平均輻射溫度也可以通過測試房間表面溫度(包k括地面及其它表面)進行計算得到,具體如下式所示。kAjtjr tj1 (2)r Ajj1式中tj是某個表面溫度,Aj是某個表面面積。本條文參考了國家標準《室內(nèi)熱環(huán)境條件》GB/T5701-2008得到。63.2%準選擇總變化幅度的95%所消耗的時間是因為此時狀態(tài)十分接近最終的穩(wěn)定狀95%間可以更合理地評價不同類型地面輻射供冷供暖系統(tǒng)的熱響應(yīng)特性。99.3%95.0%
98.2%86.5%VcVc0τ 1τ 2τ 3τ 4τ 5τTime圖1不同變化幅度所消耗的時間設(shè)計一般規(guī)定回水溫度推薦不低于3060℃。由于地面輻射供冷系統(tǒng)不具備除濕能力,需要增加一套除濕系統(tǒng)(如風機盤管系統(tǒng)避免供冷管表面結(jié)露要求供水溫度高于空氣露點溫度1℃~2℃水溫度可以避免家具下低溫表面的結(jié)露。20.5定地面輻射供冷表面平均溫度下限值:人員短期停留為19℃,人員長期停留為21℃。在進行輻射末端的動態(tài)換熱特性評估時,需要確定采用哪
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
- 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025-2030年中國調(diào)節(jié)閥市場規(guī)模調(diào)研及前景發(fā)展趨勢分析報告
- 2025-2030年中國藍寶石襯底行業(yè)發(fā)展現(xiàn)狀調(diào)查規(guī)劃分析報告
- 2025-2030年中國節(jié)能電器行業(yè)競爭狀況及投資發(fā)展前景分析報告
- 2025-2030年中國聚丁烯管行業(yè)發(fā)展趨勢及投資策略研究報告
- 2025-2030年中國網(wǎng)站優(yōu)化行業(yè)發(fā)展動態(tài)及投資前景分析報告新版
- 2025-2030年中國納濾及反滲透復合膜行業(yè)市場未來發(fā)展趨勢及前景調(diào)研分析報告
- 2025-2030年中國磁阻同步電動機行業(yè)發(fā)展現(xiàn)狀及投資策略預測研究報告
- 2025-2030年中國堿性電池行業(yè)運行動態(tài)及投資發(fā)展前景預測報告
- 2025-2030年中國直焊縫鋼管行業(yè)發(fā)展狀況及投資前景規(guī)劃研究報告
- 2025-2030年中國疏浚工程行業(yè)市場競爭格局展望及投資策略分析報告
- 2025年河南鶴壁市政務(wù)服務(wù)和大數(shù)據(jù)管理局招聘12345市長熱線人員10人高頻重點提升(共500題)附帶答案詳解
- 建設(shè)項目安全設(shè)施施工監(jiān)理情況報告
- 春節(jié)期間安全施工措施
- 2025年大唐集團招聘筆試參考題庫含答案解析
- 建筑工地春節(jié)期間安全保障措施
- 2025山東水發(fā)集團限公司招聘管理單位筆試遴選500模擬題附帶答案詳解
- 2024-2030年中國建筑玻璃行業(yè)市場深度調(diào)研及競爭格局與投資價值預測研究報告
- 泌尿:膀胱腫瘤病人的護理查房王雪-課件
- 企業(yè)短期中期長期規(guī)劃
- 中華民族共同體概論講稿專家版《中華民族共同體概論》大講堂之第一講:中華民族共同體基礎(chǔ)理論
- 《商務(wù)溝通-策略、方法與案例》課件 第一章 商務(wù)溝通概論
評論
0/150
提交評論