版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認領(lǐng)
文檔簡介
1、目錄第一章 編制說明···································1一、 編制依據(jù)············
2、·························1二、編制目的························
3、;··············1第二章 工程概況·································1第三章 施工總
4、體部署及項目管理機構(gòu)················2第四章 施工準備工作······························4第五
5、章 施工專項方案······························4一、 燈光工程施工方案················
6、3;············5二、 腳手架工程施工技術(shù)方案······················8三、節(jié)能施工方案···········
7、3;·····················13四、現(xiàn)場施工臨時用電施工方案·····················18五、安全事故應(yīng)急救援預(yù)案··
8、3;······················25第六章 質(zhì)量、進度計劃保證措施···················30一、 管理組織措施····
9、···························30二、技術(shù)保證措施·····················
10、183;···········30三、人力、機械配備措施···························31四、成品保護措施·······
11、83;·························31五、材料質(zhì)量抽檢監(jiān)控······················
12、83;······31第七章 施工安全保證措施·························32一、安全生產(chǎn)措施··············
13、83;··················32二、安全用電措施······························
14、;···32三、安全防火措施···································33第八章 文明施工措施········&
15、#183;····················33第九章 環(huán)境保護措施···························&
16、#183;·33第一章 編制說明1 編制依據(jù)1.1 . 遠順工程設(shè)計提供的設(shè)計圖紙1.2. 建筑電氣照明裝置施工與驗收規(guī)GB 50617-20101.3 .建筑電氣工程施工質(zhì)量驗收規(guī)GB50303-20021.4 . 電氣裝置工程盤、柜及二次回路結(jié)線施工及驗收規(guī)GB50171-921.5 .建筑工程施工質(zhì)量驗收統(tǒng)一標(biāo)準GB 50300-20011.6 . 民用建筑電氣設(shè)計規(guī)JGJ 1620081.7.建筑照明設(shè)計標(biāo)準GB 50034-20081.8.我公司以往類似工程的施工經(jīng)驗 1.9 .博羅縣文體旅游局的相關(guān)要求。1.10. 其它相關(guān)現(xiàn)行的法律、法規(guī)及行業(yè)標(biāo)準2 . 編制目的目的是
17、針對博羅縣文化中心幻影燈光工程,在施工組織、施工管理、勞動力組織、材料設(shè)備供應(yīng)、施工工藝、進度計劃、質(zhì)量安全措施等方面作的總體規(guī)劃,使工程合理、有效、高質(zhì)量地完成 。第二章 工程概況博羅縣文化中心幻影燈光工程的施工地點位于新建的縣文化中心區(qū)域,該工程由影劇院、圖書館、文化館三大部分的室外燈光照明工程組成。燈具類型有金鹵筒燈、金鹵埋地?zé)?、LED筒燈、LED投光燈、LED燈具、LED條形燈具、節(jié)能壁燈等,合計共923套(不含LED條形燈具)。第三章 施工總體部署及項目管理機構(gòu)3.1 總體目標(biāo)工程總體目標(biāo)1質(zhì)量目標(biāo)合格,爭創(chuàng)優(yōu)良工程2工期目標(biāo)計劃總工期在60日歷天竣工3安全生產(chǎn)目標(biāo)安全生產(chǎn)達標(biāo)4文明
18、施工目標(biāo)創(chuàng)建文明施工工地施工中嚴格執(zhí)行建筑工程安全管理條例、建筑施工安全檢查標(biāo)準JGJ59-99以及省建設(shè)工程文明施工若干規(guī)定。3.2 施工總體部署根據(jù)設(shè)計文件的容、建設(shè)單位的工期、質(zhì)量要求、施工環(huán)境和施工條件,分析本工程的特點,制定出切實可行、科學(xué)的施工組織方案,合理安排人力物力,組織施工作業(yè)。3.3 管理模式實行項目管理法和目標(biāo)管理責(zé)任制,組成精干的項目領(lǐng)導(dǎo)班子。施工中嚴格執(zhí)行建設(shè)工程項目管理規(guī)GB/T503262001,按照工程項目的規(guī)律,組織技術(shù)、質(zhì)安、材料、設(shè)備、勞務(wù)等生產(chǎn)部門,對工程施工進行全面、全過程管理,確保工程快速、優(yōu)質(zhì)、安全地完工,為建設(shè)單位提供合格的工程產(chǎn)品。工程質(zhì)量、安
19、全體系設(shè)置如下:職務(wù)年齡發(fā)證機關(guān)證件號聯(lián)系項目經(jīng)理華茂35國家建設(shè)部省安全生產(chǎn)監(jiān)管局粵7粵建安B(2011)00009715189519技術(shù)負責(zé)人朱克波39市人事局粵中職證字第84號5189519施工員柯木欣49市住房和城鄉(xiāng)規(guī)劃建設(shè)局0023365189519質(zhì)量檢查員黎寶凡26市住房和城鄉(xiāng)規(guī)劃建設(shè)局0023385189519安全員黃建文29市建設(shè)局省安全生產(chǎn)監(jiān)管局粵建安C(2008)001228051895193.4 勞動力組織 根據(jù)施工組織設(shè)計和進度計劃要求,建立專業(yè)工種施工班組,組織施工作業(yè)人員進場,并進行施工安全技術(shù)和質(zhì)量技術(shù)交底。3.4.1 勞動力組織計劃表: 序號工種設(shè)定組數(shù)每組人
20、數(shù)合計人數(shù)計劃進場時間備注1電工236根據(jù)業(yè)主要求負責(zé)電氣、照明安裝工程2架子工133根據(jù)業(yè)主要求負責(zé)腳手架搭設(shè)以上工種班組人員在施工中根據(jù)施工實際情況合理調(diào)配。所有特種作業(yè)操作工均持證上崗。3.5 施工機械設(shè)備計劃表3.5.1、主要機械設(shè)備配備表序號機械設(shè)備名稱規(guī)格型號產(chǎn)地單位數(shù)量1氬弧焊電焊機臺12沖擊鉆臺33皮卡汽車輛14接地電阻測定儀GXT-80臺25鉗形電流表-600A塊26兆歐表500V塊2第四章 施工準備工作4.1 技術(shù)準備 4.1.1 組織施工技術(shù)人員學(xué)習(xí)并熟悉地掌握施工圖紙和有關(guān)的技術(shù)規(guī)及標(biāo)準要求;技術(shù)人員將工程情況、施工方案、技術(shù)措施及注意事項等向施工的各工種班組人員作詳細
21、的技術(shù)交底,嚴格按設(shè)計圖紙、施工規(guī)和施工方案施工。 4.1.2 認真審閱施工圖紙,會同、建設(shè)單位及監(jiān)理等單位進行圖紙會審,做好圖紙會審記錄,作為施工依據(jù)。 4.1.3 加強原材料檢驗,及時提供原材料試驗報告和混凝土配合比,做到先檢驗合格后才使用。第五章 施工技術(shù)方案因本工程的施工情況特殊,安裝室外燈具的時候需要在建筑物的外面搭設(shè)腳手架,所以,本節(jié)施工技術(shù)方案的容,除了常規(guī)的闡述電氣部分的施工方案外,還增加了腳手架搭設(shè)的施工技術(shù)方案容一、 室外燈光照明工程施工方案一)、設(shè)備開箱檢查1外包裝及密封良好。2開箱檢查型號、規(guī)格、數(shù)量符合設(shè)計要求,設(shè)備無損傷附件、備件齊全。3產(chǎn)品技術(shù)文件產(chǎn)品合格證、說明
22、書、出廠試驗報告齊全。4柜(盤)外觀無損傷及變形,油漆完整無損,部電器裝置及元件,絕緣瓷件齊全,無損傷、裂紋等缺陷。二)、光源及燈具的選擇:光源及燈具均應(yīng)具有較好的耐腐蝕性能及良好的電氣絕緣性能。燈具應(yīng)符合燈具通用安全要求及試驗(GB7000-86)的有關(guān)要求,燈具的光學(xué)性能應(yīng)滿足設(shè)計要求。1. LED燈具:采用鋁合金材料,進行防水處理后安裝在全鋁燈架上,連同變壓器組成一體燈具。2.地埋燈:燈具防護等級達到IP67,安裝時排氣孔要按照生產(chǎn)廠家的說明要求進行處理,接線盒應(yīng)安裝防水密封圈,光源應(yīng)盡量放在燈具的底部,燈具表面玻璃溫度應(yīng)控制在65度以下。燈具安裝前應(yīng)按照設(shè)計要求側(cè)線、定位,安裝好預(yù)埋件
23、。3. LED線條燈:燈帶安裝應(yīng)橫平豎直,進入燈帶的電源應(yīng)采用軟線保護,燈帶支架應(yīng)分布均勻,支架的顏色與燈帶應(yīng)該統(tǒng),支架應(yīng)與燈帶可靠連接。三)、線管安裝本工程的線管采用PVC-U電工難燃套管及配件,線管的安裝方式主要有三種情況:1).埋地敷設(shè);2)天花吊頂敷設(shè);3)明裝。所有的線管的安裝之前都必須經(jīng)過檢測合格以后,自檢合格并經(jīng)現(xiàn)場監(jiān)理確認合格以后才能使用。1.對于埋地敷設(shè)的線管,除了埋設(shè)深度符合施工規(guī)及設(shè)計要求之外,還應(yīng)該在線管表面鋪上100mm的細沙,再鋪上一層紅磚做保護,然后才能回填泥土覆蓋。2.對于在吊頂敷設(shè)的線管,要求嚴格按照施工規(guī)及材料供應(yīng)廠家的使用要求進行連接,以保證管連接口的施工
24、質(zhì)量,另外,應(yīng)該另外設(shè)置管線的吊裝支點,不允許利用天花吊頂頂板作為支承點,直接把管放置在吊頂面上。管線的拐彎處,需使用廠家提供的專用彈簧進行彎曲,不允許人工在不使用任何輔助機械的情況下進行直接的彎管作業(yè)。3.對于明裝的線管,除了固定間距符合施工規(guī)要求外,路徑的設(shè)置還應(yīng)該根據(jù)現(xiàn)場具體的情況做到合理,美觀。四)、管穿線1.管的導(dǎo)線嚴禁有中間接頭,如果不得不出現(xiàn)有接頭,則必須設(shè)置接線盒。2.管穿線的總截面面積不能超過管截面積的40%,另外,管穿線的根數(shù)不能超過施工圖紙電氣設(shè)計總說明中規(guī)定的根數(shù)。五)、電纜敷設(shè)電纜在安裝前必須測試絕緣電阻達到良好值時才能敷設(shè),同時在敷設(shè)時必須保證不得有損傷電纜的現(xiàn)象,
25、電纜敷設(shè)后,在有可能受壓的路段采取加保護管進行保護,將保護管的兩頭加工成喇叭形,防止傷害電纜,電纜需彎曲時低至全塑型電纜不小于電纜外徑的六倍。電纜安裝應(yīng)橫平豎直安裝牢固、美觀整齊。電纜敷設(shè)在任何場所,嚴禁重疊、交叉、擠壓等現(xiàn)象。用金屬卡碼固定電纜時,在金屬卡碼處用絕緣膠片墊托加強絕緣,避免傷害電纜,支持卡碼的力度必須受力均勻。六)、配電箱的安裝1.配電箱安裝位置應(yīng)正確,固定牢靠,部件齊全,箱體開孔采用擴孔鉆頭開孔,開孔應(yīng)合適,且切口應(yīng)整齊。2.箱外應(yīng)清潔,油漆完整,箱門開關(guān)靈活,回路編號齊全、正確,接線整齊,PE 線安裝明顯、牢固。3.配電箱全部電器及相關(guān)回路安裝完畢后,用500V 搖表對線路
26、進行絕緣測試,并做好記錄。4.配電箱的試運行(1).配電箱試運行前,檢查配電柜有無雜物,安裝是否符合質(zhì)量評定標(biāo)準。相色、銘牌號是否齊全。(2).送電空載運行24 小時,無異?,F(xiàn)象,經(jīng)甲方檢查確認后,向甲方報一份存檔。七)、接地保護、等電位連接、漏電保護1. 本工程配電系統(tǒng)采用三相五線制,接線時應(yīng)注意三相平衡。2. 所有電氣設(shè)備及電氣線路在正常情況下不帶電的金屬外殼均應(yīng)按規(guī)程接地。3. 電源引入建筑物進線處設(shè)置接地裝置,接地電阻不應(yīng)大于1歐姆,如實際接地電阻不滿足要求,必須增加接地極。4. 保證燈具配管、接線盒、燈具支架的可靠接地。5. 帶有漏電裝置的回路,要求漏電裝置動作時間小于0.1秒,動作
27、電流小于30mA。八)、電氣照明安裝質(zhì)量控制安裝完畢,絕緣電阻礙搖測合格后,進行通電試運轉(zhuǎn)。通電后應(yīng)仔細檢查和巡視,檢查燈飾的控制是否靈活、準確;開關(guān)與燈飾控制順序相對應(yīng)。發(fā)現(xiàn)問題立即斷電,迅速查找原因進行修復(fù)。使用兆歐表測量絕緣最阻時應(yīng)注意的問題:1測量時應(yīng)使兆歐表同被測物的接線正確。為防止接線因絕緣不良造成測量誤差,兆歐表接線柱與被測物之間的連接導(dǎo)線,不得用雙股絕緣或絞線。2測量時手搖發(fā)電機要保持勻速,不可過快或過慢,使指針搖擺不定。通常最適宜的速度為120轉(zhuǎn)/分鐘。3測量完畢,須待兆歐表停止轉(zhuǎn)動和被測物接地放電后,方能拆除兆歐表與被測物之間的連接導(dǎo)線。4為便于對測量結(jié)果進行分析,在測量時
28、除應(yīng)記錄好被測物的絕緣電阻外,還應(yīng)盡量記錄對測量有影響的其他因素,如當(dāng)時的環(huán)境溫度、濕度,所使用的兆歐表電壓級量程圍和被測物的有關(guān)狀況等。九)、照明器具試運行1.電氣照明器具應(yīng)以系統(tǒng)進行試電運行,系統(tǒng)的全部照明燈具均得開啟,同時投入運行,運行時間為24 小時。2.全部照明燈具通電運行開始后,要及時用鉗流表、萬用表測量系統(tǒng)的電源電壓及負荷電流,并做好記錄。試運行過程中每隔8 小時還需測量記錄一次,直到24 小時運行完為止。上述各項測量的數(shù)值要填入試運行記錄表。二、 腳手架工程施工技術(shù)方案1 腳手架的部置本工程采用48×3.5mm鋼管,雙排落地式腳手架,排架步距取1.8m,外排架步距取0
29、.9m,橫距1.05m,立桿縱距取1.2m。2 .腳手架的施工2.1、搭設(shè)作業(yè)程序底座布置豎底立桿(角邊起)第一步縱向平桿和橫向平桿按此依次向前伸搭設(shè),直至第一架交圈完成。交圈后,全面檢查構(gòu)架質(zhì)量和地基情況,嚴格確保設(shè)計要求和構(gòu)架量設(shè)置連墻桿按第一步搭設(shè)要求和作業(yè)程序搭設(shè)第二步,第三步隨搭設(shè)進程及時裝設(shè)連墻桿件,剪刀撐、卸荷結(jié)構(gòu)裝設(shè)作業(yè)層間橫桿、鋪設(shè)腳手板和裝設(shè)作業(yè)欄桿,擋腳板或圍護、封閉施工。2.2、腳手架的基底腳手架直接支撐在硬地化地面上,腳墊150cm×150cm的模板。 2.3、掃地桿的搭設(shè)掃地桿設(shè)置為橫向雙排水平桿,應(yīng)貼墊板上安裝,離地30cm左右,安裝要及時、牢固。2.4
30、、連墻桿搭設(shè)連墻桿的搭設(shè)一邊與預(yù)埋件連接,一邊與排立桿搭設(shè)。即:在現(xiàn)澆混凝土的框架梁、柱留預(yù)埋件,然后用鋼管連接。連墻桿布置一般豎向間距為步距的3倍,橫向間柜為4米。2.5、剪刀撐搭設(shè)為了增強腳手架縱向穩(wěn)定性和整體性,在腳手架豎向傳力結(jié)構(gòu)的外側(cè)應(yīng)沿高度由下而上連續(xù)設(shè)置豎向的剪刀撐,桿與地面夾角在450600圍,剪刀撐應(yīng)沿腳手架全長和全高連續(xù)布設(shè),水平最大間距7m,外排立面水平距離不足3m,可設(shè)“之”字形斜撐。做法見剪刀撐布置圖。2.6、縱向結(jié)構(gòu)2.6.1. 縱向布置采用雙排落地式腳手架,排立桿間距1.2米,外排立桿間距1.2米,外排間距1.05米;2.6.2. 立桿垂直控制為防止立桿偏斜而產(chǎn)生
31、過大的偏心力,應(yīng)嚴格控制立桿的垂直度:2.7、橫向結(jié)構(gòu)橫向承力結(jié)構(gòu)是由立桿和短橫桿組成的橫向結(jié)構(gòu),是腳手架直接承受和傳遞垂直荷載的部分,腳手架的受力主體,在使用過程中的任何情況下不得拆除貼近立桿的短橫桿;短橫桿垂直距離為1.8米(步高h),在施工中需留門洞口的地方兩邊必須加人字形斜撐桿,斜撐桿與地面夾角600。2.8、作業(yè)層上料作業(yè)層寬為1.8米,腳手架用18mm厚夾板滿鋪,腳手板鋪設(shè)應(yīng)做到嚴密、牢固,不得留超過50mm以上的間隙,嚴禁留長度大于150mm的探頭板。腳手板應(yīng)在下列部位給予固定:(1) 腳手板的兩端和拐角處;(2) 沿板長方向間隔15-20m;(3) 坡道和平臺的兩端;(4) 其
32、它可能發(fā)生滑動和翹起的部位。2.9、施工門洞處理腳手架遇道施工必須預(yù)留通行的門洞時,應(yīng)采取構(gòu)造措施:(1) 門洞上的立桿從門洞上的大橫桿件開始綁扎;(2) 門洞上的外大橫桿用根鋼管加強;(3) 腳手架外兩側(cè)在門兩邊設(shè)人字形斜撐,斜撐與地面成600夾角,斜撐應(yīng)與門洞上的立桿和大橫桿綁扎牢固;(4) 門洞上兩側(cè)立桿,用雙鋼管加強,做法見門洞加強桿立面圖。2.10、桿件和扣件2.10.1. 本工程桿件為48×3.5鋼管,鋼管長以46m為好,嚴禁使用有嚴重銹蝕、彎曲、壓扁和有裂縫的鋼管;2.10.2. 扣件使用要有出廠合格證,有脆裂、變形、滑絲的扣件禁止使用,扣件表面應(yīng)進行防銹處理,扣件活動
33、部位能靈活轉(zhuǎn)動。2.11、中心節(jié)點在中心節(jié)點處桿件連接應(yīng)盡量靠在一起,以減少偏心矩,貼合面必須嚴格整齊,搭設(shè)腳手架的扭力矩4060Nm.2.12、構(gòu)造措施(1) 立桿要注意桿件的長短搭配使用,立桿接頭必須采用對接桿和對接扣件連接,立桿的接頭與相鄰大橫桿的距離不應(yīng)小于步高的三分之一,相鄰兩立桿的接頭應(yīng)互相錯開,相鄰接頭的高度應(yīng)于大于500mm;(2) 大橫桿的長度不宜小于6m,立桿和大橫桿必須用直角扣件扣緊,不得遺漏;上下相鄰的大橫桿應(yīng)錯開布置在立桿的里側(cè)和外側(cè),以減少立桿的偏心受荷情況;同一排大橫桿的水平偏差不大于該面腳手架長度的1/300;同一水平的外木橫桿的接頭和上下相距的兩根據(jù)大橫桿的接
34、頭均應(yīng)相互錯開,錯開距離大于500mm;(3) 小橫桿應(yīng)搭于大橫桿與立桿交叉上,分別用兩種扣件扣緊,在搭設(shè)和使用過程中不得拆除貼近立桿的小橫桿。2.13、搭設(shè)作業(yè)應(yīng)注意事項(1) 嚴禁48mm和51mm鋼管及其它相應(yīng)扣件混用;(2) 連墻桿和剪刀撐應(yīng)及時設(shè)置,不得滯后超過2步架;(3) 桿件端部伸出扣件之外的長度不得小于100mm;(4) 在頂排連墻桿件之上的架高不得多于兩步;(5) 剪刀撐的斜桿與基本構(gòu)架結(jié)構(gòu)桿件之間至少有三道連接,其中斜桿的搭接接頭部位于少有一道連接;(6) 必須有良好的放電、避雷裝置;(7) 加強施工人員及施工管理人員的安全技術(shù)培訓(xùn),實行持證上崗,以保證質(zhì)量、安全措施的要
35、求得地以切實實施;2.14、拆卸作業(yè)腳手架的拆除順序:安全網(wǎng)擋腳板護身欄腳手板小橫桿大橫桿立桿連墻桿、縱向支撐、剪刀撐。拆除腳手架應(yīng)注意以下幾點:(1) 連墻桿應(yīng)待其上部桿件拆除完畢才能拆除,嚴禁出現(xiàn)拆除了多步連墻干后再拆構(gòu)架桿件的危險作業(yè);(2) 松開扣件,水平桿件應(yīng)隨即撤下,不得松掛要架上;(3) 拆除長桿件時應(yīng)兩人同時作業(yè),以免單人作業(yè)時地閃失事故;(4) 拆下的桿配件應(yīng)吊遠至地面,不得向下拋擲:(5) 拆除腳手架時應(yīng)設(shè)專人警戒監(jiān)護,以防傷人;(6) 必須安排泥工班配合隨拆除過程及時補做外墻面和洞口工作。3.安全防護措施安全施工在施工方案中已提及,腳手架要有牢固的骨架,可靠的連接,穩(wěn)妥的
36、基底,并按正確的順序架設(shè)和拆卸;除此而外,尚需重視在使用過程中出現(xiàn)的安全防護問題:3.1. 避免高處墜落物品砸傷地面活動人群。3.2. 在腳手架邊有可能出現(xiàn)人員墜落的地方,設(shè)能承接墜落人和物地安全網(wǎng);3.3. 根據(jù)氣象預(yù)報,在臺風(fēng)到來前,應(yīng)停止腳手架的作業(yè)并進行檢查加固,臺風(fēng)過后要對腳手架全面檢查加固;3.4. 在施工期間應(yīng)派專人定期和不定期檢查腳手架的安全情況,做到無事故隱患,發(fā)現(xiàn)有隱患及時處理;3.5. 在安裝作業(yè)時應(yīng)做好安全防護,作業(yè)人員必須戴安全帽,系安全帶和工具袋等;3.6. 在首層各通道入口必須搭設(shè)雙層防護棚,并掛上安全標(biāo)志;3.7. 安全網(wǎng)要用合格的密目式安全網(wǎng);4、文明施工4.
37、1、施工現(xiàn)場安平面圖堆放材料及半成品,堆放整齊;4.2、施工現(xiàn)場要經(jīng)常保持整潔衛(wèi)生,搭設(shè)后應(yīng)當(dāng)班把余下的材料堆放整齊,雜物清理運走;4.3、安全立網(wǎng)掛設(shè)整齊、美觀;三、節(jié)能施工方案1.編制依據(jù)1.1 . 遠順工程設(shè)計提供的設(shè)計圖紙1.2. 建筑節(jié)能工程施工質(zhì)量驗收規(guī)GB50411-20071.3.建筑電氣照明裝置施工與驗收規(guī)GB 50617-20101.4 .建筑電氣工程施工質(zhì)量驗收規(guī)GB50303-20021.5 . 電氣裝置工程盤、柜及二次回路結(jié)線施工及驗收規(guī)GB50171-921.6 .建筑工程施工質(zhì)量驗收統(tǒng)一標(biāo)準GB 50300-20011.7 . 民用建筑電氣設(shè)計規(guī)JGJ 16200
38、81.8.建筑照明設(shè)計標(biāo)準GB 50034-2008 1.9 .博羅縣文體旅游局的相關(guān)要求。1.10. 其它相關(guān)現(xiàn)行的法律、法規(guī)及行業(yè)標(biāo)準。2.工程概況博羅縣文化中心幻影燈光工程的施工地點位于新建的縣文化中心區(qū)域,該工程由影劇院、圖書館、文化館三大部分的室外燈光照明工程組成。燈具類型有金鹵筒燈、金鹵埋地?zé)?、LED筒燈、LED投光燈、LED燈具、LED條形燈具、節(jié)能壁燈等,合計共923套(不含LED條形燈具)。3.節(jié)能的指導(dǎo)思想與目標(biāo)3.1節(jié)能的指導(dǎo)思想建立健全工程質(zhì)量和節(jié)能施工保證體系,使工程質(zhì)量和節(jié)能目標(biāo)自始至終處于受控制狀態(tài)中。充分發(fā)揮公司管理人員及技術(shù)上的優(yōu)勢,應(yīng)用新技術(shù)、新工藝、新設(shè)備
39、、新材料,科學(xué)管理、精心施工,高速、優(yōu)質(zhì)、低耗地完成本項工程。組建有豐富施工經(jīng)驗的項目經(jīng)理部,對該工程實行科學(xué)管理。3.2質(zhì)量與節(jié)能目標(biāo)質(zhì)量目標(biāo):確保博羅文化館燈光幻影工程質(zhì)量達到合同要求。節(jié)能目標(biāo):確保達到節(jié)能指標(biāo)合格的工程。4.工程節(jié)能設(shè)計4.1 本工程的所有燈具皆采用LED光源。4.2 供電電纜電線皆采用符合節(jié)能要求型的。5.工程節(jié)能的技術(shù)措施節(jié)能材料須有本市材料準用證、檢驗報告及出廠合格證,主要材料必須有材料交易證。材料使用前必須經(jīng)復(fù)試合格后方能使用。工程材料的邊角料,余料要盡可能利用。安全防護材料應(yīng)選用可重復(fù)利用的材料。工地廢料要分類收集。6 電纜材質(zhì)要求:電纜材料在燃燒時所產(chǎn)生的氣
40、體毒性,應(yīng)符合GA306.122001以及GA1321996材料產(chǎn)煙毒性分級的規(guī)定要求,煙氣毒性(濃度)12.4mg/l。電纜燃燒時逸出氣體的PH 值和導(dǎo)電率測試按GB/T17650.2-98規(guī)定,PH 值不小于4.3,導(dǎo)電率不大于10s/mm。電纜燃燒時的阻燃性能應(yīng)能滿足GB/T 18380-2001 規(guī)定的A 類成束電纜垂直燃燒試驗。6.我方對施工機具的節(jié)能要求選擇低能耗的施工機具。能使用手動機具的就不用電動工具。電動機具要及時維護保養(yǎng),保證正常使用狀態(tài),避免機具非正常耗能。禁止機具非正??蛰d運行。禁止使用碘鎢燈做照明。7.低壓動力照明配電系統(tǒng)施工節(jié)能7.1 電氣節(jié)能的措施采用綠色光源、高
41、效節(jié)能型燈具合理選擇電纜截面,減少材料使用,節(jié)約能源。加強對母線壓接頭的質(zhì)量控制,避免由于壓接頭的加工質(zhì)量問題而產(chǎn)生局部接觸電阻增加而造成的發(fā)熱,以減少損耗。低壓配電系統(tǒng)選擇的電纜、電線截面不得低于設(shè)計值,進場時對其截面和每芯導(dǎo)體電阻值進行見證取樣送檢。每芯導(dǎo)體電阻值應(yīng)符合下表的規(guī)定。標(biāo)稱截面(mm2)20時導(dǎo)體最大電阻(/km)圓筒導(dǎo)體(不鍍金屬)1.512.12.57.4144.6163.08101.83161.15250.727350.524500.387700.268不同標(biāo)稱截面的電纜、電線每芯導(dǎo)體最大電阻值電纜穿管敷設(shè):管徑不小于電纜外徑的1.5倍。管的彎曲半徑為管外徑的10倍,且不
42、應(yīng)小于所穿電纜的最小彎曲半徑。電纜穿管時,若無彎頭,長度不宜超過50m;有一個彎頭時不宜超過20m;有兩個彎頭時,應(yīng)設(shè)電纜井,電纜中間接線盒應(yīng)放在電纜井,接線盒周圍應(yīng)有火災(zāi)延燃設(shè)施。電纜在室埋地、穿墻或穿樓板時,應(yīng)有穿管保護。水平明敷時距地應(yīng)不小于2.5m。垂直明敷時,高度1.8m以下部分應(yīng)有防止機械損傷的措施。7.2 照明配電干線各相負荷分配規(guī)定三相照明配電干線的各相負荷宜分配平衡,其最大相負荷不宜超過三相負荷平均值的115%,最小負荷不宜小于三相負荷平均值的85%。單相負荷應(yīng)均勻分配到三相上。當(dāng)單相負荷的總?cè)萘啃∮谟嬎銍鄬ΨQ負荷總?cè)萘康?5%時,全部按三相對稱負荷計算;當(dāng)超過15%時,
43、應(yīng)將單相負荷換算為等效三相負荷,再與三相負荷相加。供電電壓允許偏差:三相供電電壓允許偏差為標(biāo)稱系統(tǒng)電壓的±7%;單相220V為+7%、-10%。公共電網(wǎng)諧波電壓限值:380V的電網(wǎng)標(biāo)稱電壓,電壓總諧波畸變率(THDu)為5%,奇次(125次)諧波含有率為4%,偶次(224次)諧波含有率為2%。諧波電流不應(yīng)超過下表中規(guī)定的允許值。標(biāo)準電壓(kV)基準短路容量(MVA)諧波次數(shù)及諧波電流允許值(A)23456789101112137862396226441921162813240.3810諧波次數(shù)及諧波電流允許值(A)14151617181920212223242511129.7188.
44、6167.88.97.1146.512諧波電流允許值表三相電壓不平衡度允許值為2%,短時不得超過4%。四、現(xiàn)場施工臨時用電施工方案 一、編制依據(jù)1.低壓配電設(shè)計規(guī)GB50054-952.建筑工程施工現(xiàn)場供電安全規(guī)GB50194-933.通用用電設(shè)備配電設(shè)計規(guī)GB50055-934.供配電系統(tǒng)設(shè)計規(guī)GB50052-955施工現(xiàn)場臨時用電安全技術(shù)規(guī)JGJ46-2005 二、施工條件1、工程概況博羅縣文化中心幻影燈光工程的施工地點位于新建的縣文化中心區(qū)域,該工程由影劇院、圖書館、文化館三大部分的室外燈光照明工程組成。燈具類型有金鹵筒燈、金鹵埋地?zé)?、LED筒燈、LED投光燈、LED燈具、LED條形燈具
45、、節(jié)能壁燈等,合計共923套(不含LED條形燈具) 2、施工現(xiàn)場用電量統(tǒng)計表:序號機具名稱型號安裝功率(kW)數(shù)量1氬弧焊電焊機 GW402122沖擊鉆日立0.7510.75三、設(shè)計容和步驟1、現(xiàn)場勘探及初步設(shè)計:(1)現(xiàn)場采用380V低壓供電,設(shè)一配電總箱,有計量設(shè)備,采用TN-S系統(tǒng)供電。(2)根據(jù)施工現(xiàn)場用電設(shè)備布置情況,采用導(dǎo)線穿鋼管埋地敷設(shè),布置位置及線路走向參見臨時配電系統(tǒng)圖及現(xiàn)場平面圖,采用三級配電,兩級防護。(3)按照JGJ46-2005規(guī)定制定施工組織設(shè)計,接地電阻R4。2、確定用電負荷: (1)、氬弧焊電焊機 Kx = 0.30 Cos = 0.70 tg = 1.02 P
46、js = 0.30×2.00 = 0.60 kW (2)、沖擊鉆 Kx = 0.30 Cos = 0.70 tg = 1.02 Pjs = 0.30×2.25 = 0.675kW (3)總的計算負荷計算,總箱同期系數(shù)取 Kx = 0.90 總的有功功率 Pjs = Kx×Pjs = 0.90×(0.6+0.675) =1.1475kw 總的無功功率(取值為有功功率的1.05倍) Qjs = 1.05×Pjs x = 1.2049kVA 總的視在功率 Sjs = (Pjs2+Qjs2)1/2 = (1.14752+1.20482)1/2 =1.6
47、638kVA 總的計算電流計算 Ijs = Sjs/(1.732×Ue) = 1.6638/(1.732×0.38) = 2.531A,3、選擇變壓器: 根據(jù)本工程的實際情況及計算結(jié)果,不用選擇變壓器,直接利用業(yè)主指定的配電箱作為一級配電箱,二級、三級配電箱由施工單位負責(zé)配備。4、選擇總箱的進線截面及進線開關(guān):(1)選擇導(dǎo)線截面:上面已經(jīng)計算出總計算電流Ijs = 2.531A,結(jié)合查表,最后選擇的電纜規(guī)格為YJL-3×2.5+2×1.5,其安全載流量為28A,能夠滿足使用要求。(2)選擇二級配電箱開關(guān):DZ20-20/3 ,其脫扣器整定電流值為Ir =
48、 20A。 (3)選擇三級箱中漏電保護器:DZ20L-15/2 ,漏電動作電流不大于30mA,漏電動作時間小于0.1S。四、安全用電技術(shù)措施 安全用電技術(shù)措施包括兩個方向的容:一是安全用電在技術(shù)上所采取的措施;二是為了保證安全用電和供電的可靠性在組織上所采取的各種措施,它包括各種制度的建立、組織管理等一系列容。安全用電措施應(yīng)包括下列容: 1、安全用電技術(shù)措施 (1)、保護接地 按規(guī)定保護接地電阻不大于4。 (2)、保護接零 本工程采用TN-S系統(tǒng)。 TN-S供電系統(tǒng)。它是把工作零線N和專用保護線PE在供電電源處嚴格分開的供電系統(tǒng),也稱三相五線制。它的優(yōu)點是專用保護線上無電流,此線專門承接故障電
49、流,確保其保護裝置動作。應(yīng)該特別指出,PE線不許斷線。在供電末端應(yīng)將PE線做重復(fù)接地。 施工時應(yīng)注意:除了總箱處外,其它各處均不得把N線和PE線連接,PE線上不得安裝開關(guān)和熔斷器,也不得把兼做PE線且PE線不得通過工作電流。PE線也不得進入漏電保護器且必須由電源進線零線重復(fù)接地處或總漏電保護器電源側(cè)零線處引出,因為線路末端的漏電保護器動作,會使前級漏電保護器動作。 (3)、設(shè)置漏電保護器 施工現(xiàn)場的總配電箱至開關(guān)箱應(yīng)至少設(shè)置兩級漏電保護器,而且兩級漏電保護器的額定漏電動作電流和額定漏電動作時間應(yīng)作合理配合,使之具有分級保護的功能。 (4)、安全電壓 安全電壓指不戴任何防護設(shè)備,接觸時對人體各部
50、位不造成任何損害的電壓。我國國家標(biāo)準GB3805-83安全電壓中規(guī)定,安全電壓值的等級有42、36、24、12、6V五種。同時還規(guī)定:當(dāng)電氣設(shè)備采用了超過24V時,必須采取防直接接觸帶電體的保護措施。 對下列特殊場所應(yīng)使用安全電壓照明器。 1)隧道、人防工程、有高溫、導(dǎo)電灰塵或燈具離地面高度低于2.5m等場所的照明,電源電壓應(yīng)不大于36V。 2)在潮濕和易觸及帶電體場所的照明電源電壓不得大于24V。 (5)、電氣設(shè)備的設(shè)置應(yīng)符合下列要求 1)配電系統(tǒng)應(yīng)設(shè)置配電柜或總配電箱、分配電箱、開關(guān)箱,實行三級配電。配電系統(tǒng)應(yīng)采用三相負荷平衡。220V或380V單相用電設(shè)備接入220/380V三相四線系統(tǒng)
51、;當(dāng)單相照明線路電流大于30A時,應(yīng)采用220/380V三相四線制供電。 2)動力配電箱與照明配電箱宜分別設(shè)置,如合置在同一配電箱,動力和照明線路應(yīng)分路設(shè)置,照明線路接線宜接在動力開關(guān)的上側(cè)。 3)總配電箱應(yīng)設(shè)置在靠近電源區(qū)域,分配電箱應(yīng)設(shè)置在用電設(shè)備或負荷相對集中的區(qū)域,分配電箱與開關(guān)箱的距離不得超過30m,開關(guān)箱與其控制的固定式用電設(shè)備的水平距離不應(yīng)超過3m。 4)每臺用電設(shè)備必須有各自專用的開關(guān)箱,禁止用同一個開關(guān)箱直接控制二臺及二臺以上用電設(shè)備(含插座)。 (6)、電工及用電人員必須符合以下要求: 1)電工必須經(jīng)過按國家現(xiàn)行標(biāo)準考核合格后,持證上崗工作;其他用電人員必須通過相關(guān)安全教育
52、培訓(xùn)和技術(shù)交底,考核合格后方可上崗工作。 暫時停用設(shè)備的開關(guān)箱必須分斷電源隔離開關(guān),并應(yīng)關(guān)門上鎖;移動電氣設(shè)備時,必須經(jīng)電工切斷電源并做妥善處理后進行。(7)、電氣設(shè)備的使用與維護 1)配電箱、開關(guān)箱應(yīng)有名稱、用途、分路標(biāo)記及系統(tǒng)接線圖。 2)配電箱、開關(guān)箱箱門應(yīng)配鎖,并應(yīng)由專業(yè)負責(zé)。 3)配電箱、開關(guān)箱應(yīng)每月進行一次檢查和維修。檢查、維修人員必須是專業(yè)電工。檢查、維修時必須按規(guī)定穿、戴絕緣鞋、手套,必須使用電工絕緣工具,并應(yīng)做檢查、維修工作記錄。 (8)、施工現(xiàn)場的電纜線路 1)電纜中必須包含全部工作芯線和作用保護零線或保護線的芯線。需要三相四線制配電的電纜線路必須采用五芯電纜。五芯電纜必須
53、包括含淡藍、綠/黃二種顏色絕緣芯線。淡藍色芯線必須用作N線;綠/黃雙色芯線必須用作PE線,嚴禁混用。 2)電纜線路應(yīng)采用埋地或架空敷設(shè),嚴禁沿地面明設(shè),并應(yīng)避免機械損傷和介質(zhì)腐蝕。埋地電纜路徑應(yīng)設(shè)方位標(biāo)志。 3)電纜類型應(yīng)更具敷設(shè)方式、環(huán)境條件等選擇。埋地敷設(shè)應(yīng)采用鎧裝電纜;當(dāng)選用無鎧裝電纜時,應(yīng)能放水、防腐。架空敷設(shè)應(yīng)采用無鎧裝電纜。 2、安全用電組織措施 建立臨時用電施工組織設(shè)計和安全用電技術(shù)措施的編制、審批制度,并建立相應(yīng)的技術(shù)檔案。 五、安全用電防火措施 1、施工現(xiàn)場發(fā)生火災(zāi)的主要原因 (1)、電氣線路過負荷引起火災(zāi); (2)、線路短路引起火災(zāi);(3)、接觸電阻過大引起火災(zāi);(4)、電
54、熱設(shè)備、照燈具使用不當(dāng)引起火災(zāi) (5)、電弧、電火花引起火災(zāi)。 2、預(yù)防電氣火災(zāi)的措施 針對電氣火災(zāi)發(fā)生的原因,施工組織設(shè)計中要制定出有效的預(yù)防措施。 (1)、施工組織設(shè)計時要根據(jù)電氣設(shè)備的用電量正確選擇導(dǎo)線截面,從理論上杜絕線路過負荷使用,保護裝置要認真選擇,當(dāng)線路上出現(xiàn)長期過負荷時,能在規(guī)定時間動作保護線路。 (2)、導(dǎo)線架空敷設(shè)時其安全間距必須滿足規(guī)要求,當(dāng)配電線路采用熔斷器作短路保護時,熔體額定電流一定要小于電纜或穿管絕緣導(dǎo)線允許載流量的2.5倍,或明敷絕緣導(dǎo)線允許載流量的1.5倍。經(jīng)常教育用電人員正確執(zhí)行安全操作規(guī)程,避免作業(yè)不當(dāng)造成火災(zāi)。 (3)、電氣操作人員要認真執(zhí)行規(guī),正確連接
55、導(dǎo)線,接線柱要壓牢、壓實。各種開關(guān)觸頭要壓接牢固。銅鋁連接時要有過渡端子,多股導(dǎo)線要用端子或涮錫后再與設(shè)備安裝,以防加大電阻引起火災(zāi)。 (4)、使用焊機時要執(zhí)行用火證制度,并有人監(jiān)護,施焊周圍不能存在易燃物體,并備齊防火設(shè)備。電焊機要放在通風(fēng)良好的地方。 (5)、施工現(xiàn)場的高大設(shè)備和有可能產(chǎn)生靜電的電氣設(shè)備要做好防雷接地和防靜電接地,以免雷電及靜電火花引起火災(zāi)。 (6)、配電箱、開關(guān)箱嚴禁存放雜物及易燃物體,并派專人負責(zé)定期清掃。 (7)、施工現(xiàn)場應(yīng)建立防火檢查制度,強化電氣防火領(lǐng)導(dǎo)體制,建立電氣防火隊伍。 (8)、施工現(xiàn)場一旦發(fā)生電氣火災(zāi)時,撲滅電氣火災(zāi)應(yīng)注意以下事項: 迅速切斷電源,以免事
56、態(tài)擴大。切斷電源時應(yīng)戴絕緣手套,使用有絕緣柄的工具。當(dāng)火場離開關(guān)較遠需剪斷電線時,火線和零線應(yīng)分開錯位剪斷,以免在鉗口處造成短路,并防止電源線掉在地上造成短路使人員觸電。 (9)、當(dāng)電源線因其它原因不能及時切斷時,一方面派人去供電端拉閘,另一方面滅火時,人體的各部位與帶電體應(yīng)保持一定充分距離,必須穿戴絕緣用品。 (10)、撲滅電氣火災(zāi)時要用絕緣性能好的滅火劑如干粉滅火機,二氧化碳滅火器,1211滅火器或干燥砂子。嚴禁使用導(dǎo)電滅火劑進行撲救。五、施工現(xiàn)場安全事故應(yīng)急預(yù)案一)、物體打擊事故應(yīng)急預(yù)案1、應(yīng)急準備1.1、組織機構(gòu)及職責(zé): A、項目部物體打擊事故應(yīng)急領(lǐng)導(dǎo)小組
57、60; 組長:項目經(jīng)理 組員:施工員、安全員、各班組長、技術(shù)員、質(zhì)檢員、值勤人員 B、物體打擊事故應(yīng)急處置領(lǐng)導(dǎo)小組負責(zé)對項目突發(fā)物體打擊事故的應(yīng)急處理。1.2、培訓(xùn)和演練 A、項目部安全員負責(zé)主持、組織全機關(guān)每年進行一次按物體打擊事故“應(yīng)急響應(yīng)”的要求進行模擬演練。各組員按其職責(zé)分工,協(xié)調(diào)配合完成演練。演練結(jié)束后由組長組織對“應(yīng)急響應(yīng)”的有效性進行評價,必要時對“應(yīng)急響應(yīng)”的要求進行調(diào)整或更新。演練、評價和更新的記錄應(yīng)予以保持。 B、施工管理
58、部負責(zé)對相關(guān)人員每年進行一次培訓(xùn)。1.3、應(yīng)急物資的準備、維護、保養(yǎng) A、應(yīng)急物資的準備:簡易單架、跌打損傷藥品、包扎紗布。 B、各種應(yīng)急物資要配備齊全并加強日常管理。2、應(yīng)急響應(yīng) 2.1、防物體打擊事故發(fā)生,項目部成立義務(wù)小組,由項目經(jīng)理擔(dān)任組長,施工員及安全員,各班組長為組員,主要負責(zé)緊急事故發(fā)生時有條不紊的進行搶救或處理,其他人員協(xié)助施工員做相關(guān)輔助工作。 2.2、發(fā)生物體打擊事故后,由項目經(jīng)理負責(zé)現(xiàn)場總指揮,發(fā)現(xiàn)事故發(fā)生人員首先高聲呼喊,通知現(xiàn)場安全員,由安全員打事故搶救,“120”,向上級有關(guān)部門或醫(yī)院打搶救,同時
59、通知生產(chǎn)負責(zé)人組織緊急應(yīng)變小組進行可行的應(yīng)急搶救,如現(xiàn)場包扎、止血等措施。防止受傷人員流血過多造成死亡事故發(fā)生。預(yù)先成立的應(yīng)急小組人員分工,各負其責(zé),重傷人員由水、電工協(xié)助送外搶救工作,值勤門衛(wèi)在大門口迎接來救護的車輛,有程序的處理事故、事件,最大限度的減少人員和財產(chǎn)損失。如事故嚴重,應(yīng)立即報告公司工程總部,并請求啟動公司級應(yīng)急救援預(yù)案。 二)、機械傷害事故應(yīng)急預(yù)案1、應(yīng)急準備1.1、組織機構(gòu)及職責(zé) A、項目部機械傷害事故應(yīng)急領(lǐng)導(dǎo)小組 組長:項目經(jīng)理 組員:施工員、安全員、各班組長、技術(shù)員、質(zhì)檢員、值勤
60、人員 B、機械傷害事故應(yīng)急處置領(lǐng)導(dǎo)小組負責(zé)對項目突發(fā)機械傷害事故的應(yīng)急處理。1.2、培訓(xùn)和演練 A、項目部安全員負責(zé)主持、組織全機關(guān)每年進行一次按機械傷害事故“應(yīng)急響應(yīng)”的要求進行模擬演練。各組員按其職責(zé)分工,協(xié)調(diào)配合完成演練,演練結(jié)束后由組長組織對“應(yīng)急響應(yīng)”的有效性進行評價,必要時對“應(yīng)急響應(yīng)”的要求進行調(diào)整或更新。演練、評價和更新的記錄應(yīng)予以保持 B、項目管理部負責(zé)對相關(guān)人員每年進行一次培訓(xùn)。1.3、應(yīng)急物資的準備、維護、保養(yǎng) A、應(yīng)急物資的準備:簡易單架、跌打損傷藥品、包扎紗布。 B、各種應(yīng)急物資要配備齊全并加強日常管理。2、應(yīng)急響應(yīng)
61、60; 2.1、防機械傷害事故發(fā)生,項目部成立義務(wù)小組,由項目經(jīng)理擔(dān)任組長,施工員及安全員,各班組長為組員,主要負責(zé)緊急事故發(fā)生時有條有理的進行搶救或處理,其他人員做協(xié)助工作。 2.2、發(fā)生機械傷害事故后,由項目經(jīng)理負責(zé)現(xiàn)場總指揮,發(fā)現(xiàn)事故發(fā)生人員首先高聲呼喊,通知現(xiàn)場安全員,由安全員打事故搶救“120”,向上級有關(guān)部門或醫(yī)院打搶救,同時通知生產(chǎn)負責(zé)人組織緊急應(yīng)變小組進行可行的應(yīng)急搶救,如現(xiàn)場包扎、止血等措施。防止受傷人員流血過多造成死亡事故發(fā)生。預(yù)先成立的應(yīng)急小組人員分工,各負其責(zé),重傷人員由水、電工協(xié)助送外搶救
62、工作,值勤門衛(wèi)在大門口迎接來救護的車輛,有程序的處理事故、事件最大限度的減少人員和財產(chǎn)損失。如事故嚴重,應(yīng)立即報告公司工程總部,并請求啟動公司級應(yīng)急救援預(yù)案。 三)、觸電事故應(yīng)急預(yù)案1、應(yīng)急準備1.1、組織機構(gòu)及職責(zé) A、項目部觸電事故應(yīng)急領(lǐng)導(dǎo)小組 組長:項目經(jīng)理 組員:施工員、安全員、各專業(yè)工長、技術(shù)員、質(zhì)檢員、值勤人員 B、觸電事故應(yīng)急處置領(lǐng)導(dǎo)小組負責(zé)對項目突發(fā)觸電事故的應(yīng)急處理。1.2、培訓(xùn)和演練 A、項目部安全員負責(zé)主持、組織全機關(guān)每年進
63、行一次按觸電事故“應(yīng)急響應(yīng)”的要求進行模擬演練。各組員按其職責(zé)分工,協(xié)調(diào)配合完成演練。演練結(jié)束后由組長組織對“應(yīng)急響應(yīng)”的有效性進行評價,必要時對“應(yīng)急響應(yīng)”的要求進行調(diào)整或更新。演練、評價和更新的記錄應(yīng)予以保持。 B、項目管理部負責(zé)對相關(guān)人員每年進行一次培訓(xùn)。1.3、應(yīng)急物資的準備、維護、保養(yǎng) A、應(yīng)急物資的準備:簡易單架。 B、應(yīng)急物資要配備齊全并加強日常管理。2、應(yīng)急響應(yīng) 2.1、脫離電源對癥搶救 當(dāng)發(fā)生人身觸電事故時,首先使觸電者脫離電源。迅速急救,關(guān)鍵是“快
64、” 2.2、對于低壓觸電事故,可采用下列方法使觸電者脫離電源 A、如果觸電地點附近有電源開關(guān)或插銷,可立即拉開電源開關(guān)或拔下電源插頭,以切斷電源。 B、可用有絕緣手柄的電工鉗、干燥木柄的斧頭、干燥木把的鐵鍬等切斷電源線。也可采用干燥木板等絕緣物插入觸電者身下,以隔離電源。 C、當(dāng)電線搭在觸電者身上或被壓在身下時,也可用干燥的衣服、手套、繩索、木板、木棒等絕緣物為工具,拉開提高或挑開電線,使觸電者脫離電源。切不可直接去拉觸電者。2.3、對于高壓觸電事故,可采用
65、下列方法使觸電者脫離電源 A、立即通知有關(guān)部門停電。 B、帶上絕緣手套,穿上絕緣鞋,用相應(yīng)電壓等級的絕緣工具按順序拉開開關(guān)。 C、用高壓絕緣桿挑開觸電者身上的電線。 2.4、觸電者如果在高空作業(yè)時觸電,斷開電源時,要防止觸電者摔下來造成二次傷害 A、如果觸電者傷勢不重,神志清醒,但有些心慌,四肢麻木,全身無力或者觸電者曾一度昏迷,但已清醒過來,應(yīng)使觸電者安靜休息,不要走動,并對其嚴密觀察。 B、如故觸電者傷勢較重,已失去知覺,但心臟跳動和呼吸還存在,應(yīng)將
66、觸電者抬至空氣暢通處,解開衣服,讓觸電者平直仰臥,并用軟衣服墊在身下,使其頭部比肩稍低,以免妨礙呼吸,如天氣寒冷要注意保溫,并迅速送往醫(yī)院。如果發(fā)現(xiàn)觸電者呼吸困難,發(fā)生痙攣,應(yīng)立即準備對心臟停止跳動或者呼吸停止后的搶救。 C、如果觸電者傷勢較重,呼吸停止或心臟跳動停止或二者都已停止,應(yīng)立即進行口對口人工呼吸法及胸外心臟擠壓法進行搶救,并送往醫(yī)院。在送往醫(yī)院的途中,不應(yīng)停止搶救,許多觸電者就是在送往醫(yī)院途中死亡的。 D、人觸電后會出現(xiàn)神經(jīng)麻痹、呼吸中斷、心臟停止跳動、呈現(xiàn)昏迷不醒狀態(tài),通常都是假死,萬萬不可當(dāng)作“死人”草率從事。 E、對于觸電者,特別高空墜落的觸電者,要特別注意搬運問題,很多觸電者,除電傷外還有摔傷,搬運不當(dāng),如折斷的肋骨扎入心臟等,可造成死亡。 四)、高空墜落事故應(yīng)急預(yù)案1、應(yīng)急準備1.1、組織機構(gòu)及職責(zé) A、項目部高處墜落事故應(yīng)急領(lǐng)導(dǎo)小組 組長:項目經(jīng)理 組員:施工員、安全員、各班組長、技術(shù)員、質(zhì)檢員、值勤人員 B、高處墜落事故應(yīng)急處置領(lǐng)導(dǎo)小組負責(zé)對項目突發(fā)高處墜落事故的應(yīng)急處理。1.2、培訓(xùn)和演練 A、項目部安全員負責(zé)主
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 土地流轉(zhuǎn)流轉(zhuǎn)資金收益分配協(xié)議
- 家具行業(yè)設(shè)計中的價值戰(zhàn)略與經(jīng)濟效益分析研究試題及答案
- 樂理考試的音樂作品鑒賞試題及答案
- 安全工程師道德與責(zé)任考題試題及答案
- 國際貿(mào)易協(xié)議理解試題及答案
- 大學(xué)物理解題技巧總結(jié)試題及答案
- 樂理考試固本強基的試題及答案
- 商法學(xué)考試試題及答案
- 熱學(xué)現(xiàn)象與實驗研究試題及答案
- 保險考試題及答案解析
- 浙江省麗水市發(fā)展共同體2024-2025學(xué)年高一下學(xué)期期中聯(lián)考政治試題(含答案)
- GB/T 45460-2025鋼絲繩在無軸向載荷條件下鋼絲繩徑向剛度的測定
- 第四課第二課時《誰唱歌》課件 一年級音樂下冊 湘藝版
- DB31T 1564-2025企業(yè)實驗室危險化學(xué)品安全管理規(guī)范
- 2025版校園食堂日管控、周排查、月調(diào)度記錄表
- (二模)咸陽市2025年高三高考模擬檢測(二)化學(xué)試卷(含答案)
- 《城鄉(xiāng)規(guī)劃管理與法規(guī)系列講座課件-建設(shè)項目規(guī)劃與審批》
- 第17課《短文兩篇》之《愛蓮說》知識點梳理及練習(xí)-2022-2023學(xué)年七年級語文下冊古詩文專題期中期末復(fù)習(xí)(部編版)(教師版)
- 零碳物流園區(qū)建設(shè)與運營模式研究
- 《高速公路改擴建工程預(yù)算定額》
- 職場心態(tài)-培訓(xùn)課件
評論
0/150
提交評論