![廣州輕工大廈空調(diào)設(shè)計-畢業(yè)設(shè)計說明書本科學(xué)位論文_第1頁](http://file4.renrendoc.com/view/fdc8dfbe71b793e6bf9648106205c105/fdc8dfbe71b793e6bf9648106205c1051.gif)
![廣州輕工大廈空調(diào)設(shè)計-畢業(yè)設(shè)計說明書本科學(xué)位論文_第2頁](http://file4.renrendoc.com/view/fdc8dfbe71b793e6bf9648106205c105/fdc8dfbe71b793e6bf9648106205c1052.gif)
![廣州輕工大廈空調(diào)設(shè)計-畢業(yè)設(shè)計說明書本科學(xué)位論文_第3頁](http://file4.renrendoc.com/view/fdc8dfbe71b793e6bf9648106205c105/fdc8dfbe71b793e6bf9648106205c1053.gif)
![廣州輕工大廈空調(diào)設(shè)計-畢業(yè)設(shè)計說明書本科學(xué)位論文_第4頁](http://file4.renrendoc.com/view/fdc8dfbe71b793e6bf9648106205c105/fdc8dfbe71b793e6bf9648106205c1054.gif)
![廣州輕工大廈空調(diào)設(shè)計-畢業(yè)設(shè)計說明書本科學(xué)位論文_第5頁](http://file4.renrendoc.com/view/fdc8dfbe71b793e6bf9648106205c105/fdc8dfbe71b793e6bf9648106205c1055.gif)
版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認(rèn)領(lǐng)
文檔簡介
摘要摘要目錄TOC\o"1-3"\h\u摘要 IAbstract II第一章緒論 11.1設(shè)計目的 11.2設(shè)計要求 11.2.1設(shè)計計算 11.2.2設(shè)計繪圖 11.2.3整理設(shè)計文件 11.3設(shè)計研究現(xiàn)狀及發(fā)展趨勢 2第二章工程資料 42.1工程概況 42.2設(shè)計氣象參數(shù) 42.2.1室外氣象參數(shù) 42.2.2室內(nèi)設(shè)計參數(shù) 42.3土建資料 5第三章空調(diào)負(fù)荷計算 63.1空調(diào)冷、濕負(fù)荷計算 63.1.1空調(diào)冷、濕負(fù)荷計算公式 63.1.2冷濕負(fù)荷計算實例 83.2濕負(fù)荷計算 153.2.1人體濕負(fù)荷的計算 163.3圍護結(jié)構(gòu)的節(jié)能設(shè)計措施和依據(jù) 16第四章方案選擇和分析 184.1常見空調(diào)方式分析比較 184.1.1方式一風(fēng)冷熱泵式中央空調(diào)方法 184.1.2方式二電制冷冷水機組方法 194.1.3方式三溴化鋰?yán)渌畽C組方法 204.2制冷方案的選用原則及其總裝機容量 20第五章空調(diào)方式的確定 225.1空氣處理設(shè)備的設(shè)置確定 225.2處理空調(diào)負(fù)荷輸送介質(zhì)分類的確定 22第六章空調(diào)布置 246.1空調(diào)布置方式 246.2各類房間空調(diào)方案的確定 246.3水系統(tǒng)的布置 246.4風(fēng)系統(tǒng)布置 26第七章末端設(shè)備的選擇 277.1空氣-水系統(tǒng)的新風(fēng)處理方案 277.2風(fēng)機盤管的選型 28第八章氣流組織計算 308.1概述 308.2常用空調(diào)氣流組織方式 308.3氣流組織方式的確定 318.4氣流組織的計算與風(fēng)口選擇 318.4.1氣流組織計算 318.4.2風(fēng)口選擇 32第九章水力計算 339.1風(fēng)系統(tǒng)水力計算 339.1.1通風(fēng)管道的設(shè)計原則 339.1.2通風(fēng)管道的選擇與制作 339.2水系統(tǒng)的水力計算 349.2.1冷凍水系統(tǒng)的選擇 349.2.2水管管徑的計算和水 359.2.3冷凍水系統(tǒng)的水力計算 36第十章設(shè)備及材料的選擇 5010.1閥門 5010.2水過濾器 5010.3軟接頭 5010.4水泵的選擇 5010.4.1冷凍水水泵的選擇 5010.4.2冷凍水補水泵選擇 5110.5冷卻水系統(tǒng)設(shè)計 5210.5.1冷卻水管道形式 5210.5.2冷卻水泵選擇 5210.6冷卻塔選擇 5310.7冷凝水系統(tǒng)的設(shè)計 54第十一章制冷機房的設(shè)計與布置 55第十二章設(shè)備保溫、消聲和減震 5712.1風(fēng)管的保溫設(shè)計 5712.2管道保溫材料 5712.3冷凍水管的保溫設(shè)計 5812.4保溫材料的選擇 5812.4.1選擇要求 5812.4.2保溫材料的選擇 5912.4.3施工過程中的注意事項 5912.5系統(tǒng)消聲 5912.5.1噪聲影響及采取的措施 5912.5.2消聲裝置的選擇 6012.5.3消聲設(shè)計步驟 6112.6系統(tǒng)減振設(shè)計 61十三章結(jié)論 63參考文獻 64致謝 65第一章緒論河南理工大學(xué)本科畢業(yè)設(shè)計(論文)第一章緒論第一章緒論1.1設(shè)計目的畢業(yè)設(shè)計是高等教育人才培養(yǎng)計劃中的重要組成部分,是教學(xué)過程中最后一個重要的教學(xué)環(huán)節(jié),是人才素質(zhì)培養(yǎng)的重要體現(xiàn)。畢業(yè)設(shè)計的目的是培養(yǎng)學(xué)生綜合運用所學(xué)基礎(chǔ)理論、專業(yè)知識及基本技能來分析和解決實際問題的能力,是進入研習(xí)單位前一次重要實戰(zhàn)演練。1.2設(shè)計要求1.2.1設(shè)計計算1)計算室內(nèi)冷、濕負(fù)荷;2)確定設(shè)計方案。包括系統(tǒng)劃分、空氣處理過程設(shè)計、冷熱源的確定、計算總冷量、總風(fēng)量;3)根據(jù)冷量和風(fēng)量確定選用空氣處理設(shè)備和制冷設(shè)備、繪出空氣處理系統(tǒng)草圖;4)全年運行工況調(diào)節(jié)分析;5)確定室內(nèi)氣流組織形式,進行氣流組織計算,風(fēng)口的選擇計算;6)進行系統(tǒng)風(fēng)道布置及管道水力計算;7)系統(tǒng)消聲減振設(shè)計;8)系統(tǒng)防排煙及保溫設(shè)計;9)對土建、水、電、動力專業(yè)的要求;10)設(shè)計總結(jié)。1.2.2設(shè)計繪圖圖紙包括設(shè)計施工說明圖,空調(diào)系統(tǒng)平面布置圖,空調(diào)系統(tǒng)圖,風(fēng)系統(tǒng)平面布置圖,風(fēng)系統(tǒng)圖。1.2.3整理設(shè)計文件1)設(shè)計說明書及計算書;2)主要設(shè)備及材料明細(xì)表;3)全部設(shè)計圖紙。1.3設(shè)計研究現(xiàn)狀及發(fā)展趨勢空氣調(diào)節(jié)系統(tǒng)是建筑能源的消耗大戶,占建筑總能耗的一半以上。而目前的暖通設(shè)計中,業(yè)主、設(shè)計人員往往在取用室內(nèi)設(shè)計參數(shù)時選用過高的標(biāo)準(zhǔn),建筑結(jié)構(gòu)能耗也很大。隨著我國的發(fā)展,人們對建筑環(huán)境的要求越來越高,建筑能耗必將有大幅度的增長。目前的一些常規(guī)的設(shè)計系統(tǒng)和負(fù)荷估算方法不能適應(yīng)現(xiàn)階段發(fā)展的需求,建筑節(jié)能技術(shù)逐漸提上了日程。按照設(shè)計規(guī)范對負(fù)荷進行詳細(xì)計算,進行建筑圍護結(jié)構(gòu)的權(quán)衡計算,使之達到合理的能耗標(biāo)準(zhǔn);采用蓄冷、熱泵、熱回收、廢熱利用等節(jié)能技術(shù);使用變流量、變風(fēng)量空調(diào)系統(tǒng),進行系統(tǒng)的優(yōu)化、智能控制;開發(fā)太陽能、風(fēng)能等新能源是專業(yè)的發(fā)展方向。第二章工程資料河南理工大學(xué)本科畢業(yè)設(shè)計(論文)第二章工程資料第二章工程資料2.1工程概況廣州市廣東輕工大廈結(jié)構(gòu)形式為鋼筋混凝土框架結(jié)構(gòu)。本工程共8層,無地下層,每層內(nèi)部結(jié)構(gòu)各不相同,空氣調(diào)節(jié)倉庫機房由內(nèi)外氣壓差實現(xiàn)通風(fēng),地上部分側(cè)面圖呈階梯狀縮小。其中有兩個樓梯,為一梯兩室。設(shè)計空調(diào)的形式時要考慮到建筑的特征和功能性要求,要考慮到普辦公室,廚房,KTV,臥室和大廳走道對空氣溫濕度、潔凈度、空氣品質(zhì)的要求費。能使建筑中空調(diào)的使用方便,風(fēng)機盤管供水側(cè)設(shè)有電動調(diào)節(jié)閥能很容易的關(guān)閉、開啟空調(diào)。同時在圍護結(jié)構(gòu)中考慮到節(jié)能和自然條件的運用。2.2設(shè)計氣象參數(shù)2.2.1室外氣象參數(shù)廣州市的主要參數(shù)如下:位置:北緯113.31東經(jīng)23室外平均風(fēng)速:1.8m/s夏季空調(diào)室外干球溫度℃夏季空調(diào)室外濕球溫度℃夏季空調(diào)日平均溫度33.5027.7030.1夏季室外平均風(fēng)速(m/s)夏季空調(diào)大氣透明度等級夏季大氣壓(Pa)11.851004502.2.2室內(nèi)設(shè)計參數(shù)1、溫、濕度夏季:Tn=26±2℃,Ф=60±10%。2、新風(fēng)量風(fēng)量的選擇以房間新風(fēng)比為主要參數(shù),選取總風(fēng)量的10%為新風(fēng)量,普通房間新風(fēng)量每人在30m3/h以上,餐廳和大廳只取新風(fēng)比。2.3土建資料建筑中需求空調(diào)設(shè)計的面積:8829.94㎡,建筑物總高度:26.5m。外墻:包括240mm、300mm、360mm、370mm、500mm?,F(xiàn)以360mm墻體為例說明墻體構(gòu)造,30mm水泥砂漿抹灰加淺色噴漿+240mm磚墻+70mm瀝青膨脹珍珠巖+20mm內(nèi)粉劇加油漆,其他厚度墻體按此比例;內(nèi)隔墻:包括120mm、200mm、240mm磚墻;屋頂:防水層10mm+C15硂30mm+水泥加氣混凝土150mm+膨脹聚苯板50mm+鍋爐渣60mm+鋼筋混凝土100mm,導(dǎo)熱系數(shù)K=0.49W/㎡·K;廁所衛(wèi)生間設(shè)空調(diào),且低于同層樓面20-50㎜。第三章空調(diào)負(fù)荷計算河南理工大學(xué)本科畢業(yè)設(shè)計(論文)第三章空調(diào)負(fù)荷計算第三章空調(diào)負(fù)荷計算用諧波反應(yīng)法詳細(xì)計算的夏季空調(diào)冷負(fù)荷,其詳細(xì)計算方法、過程及計算依據(jù)如下:根據(jù)《采暖通風(fēng)與空氣調(diào)節(jié)設(shè)計規(guī)范》(GB50019-2003),對下列各項得熱量進行計算。(1)通過圍護結(jié)構(gòu)傳入的熱量;(2)透過外窗進入的太陽輻射熱量;(3)人體散熱量;(4)照明、設(shè)備等內(nèi)部熱源的散熱量。3.1空調(diào)冷、濕負(fù)荷計算3.1.1空調(diào)冷、濕負(fù)荷計算公式(1)外墻和屋頂傳熱形成的逐時冷負(fù)荷宜按式3-1計算:(3-1)——計算時間,h;——時間延遲,h;——冷負(fù)荷計算溫度的逐時值,h;——維護結(jié)構(gòu)計算面積,m2;——維護結(jié)構(gòu)傳熱系數(shù),W/m2·K。(2)外窗溫差傳熱形成的逐時冷負(fù)荷宜按式3-2計算:(3-2)——外窗或玻璃幕墻的計算面積,m2;——外窗或玻璃幕墻的傳熱系數(shù),W/m2·K;——計算時刻的負(fù)荷溫差,℃。(3)外窗日射得熱形成的逐時冷負(fù)荷宜按式3-3計算:(3-3)——外窗或玻璃幕墻的計算面積,m2;——外窗或玻璃幕墻的有效面積系數(shù);——地點修正系數(shù);——外窗或玻璃幕墻內(nèi)遮陽設(shè)施的遮陽系數(shù);——外窗或玻璃幕墻玻璃的遮擋系數(shù);——負(fù)荷強度,W/m2。(4)內(nèi)墻、和地面形成的冷負(fù)荷可概略按式3-4計算:(3-4)——夏季空氣調(diào)節(jié)室外計算日平均溫度,℃;——考慮太陽輻射熱等因素的附加空氣溫升,℃;——室內(nèi)空調(diào)計算溫度,℃。(5)燈光冷負(fù)荷當(dāng)電壓一定時,室內(nèi)照明散熱量是不隨時間變化的穩(wěn)定散熱量,但是照明散熱仍以對流及輻射兩種方式進行散熱,因此,照明散熱形式的冷負(fù)荷計算仍采用相應(yīng)的冷負(fù)荷系數(shù)。根據(jù)照明燈具的類型和安裝方式不同,其逐時冷負(fù)荷計算式分別為:對熒光燈:CL=1000NCcl(3-5)對于白熾燈:CL=1000n1n2NCcl(3-6)N—照明燈具所需功率,KW;n1—鎮(zhèn)流器消耗的功率系數(shù),當(dāng)明裝熒光燈的鎮(zhèn)流器裝在空調(diào)房間時取1.2;當(dāng)暗裝熒光燈鎮(zhèn)流器裝設(shè)在頂棚內(nèi)時取1.0;n2—燈罩隔熱系數(shù),當(dāng)熒光燈上部穿有小孔,可利用自然通風(fēng)散熱于棚內(nèi)時取0.5-0.6;而熒光燈罩無通風(fēng)孔者,則視頂棚內(nèi)通風(fēng)情況取0.6-0.8;Ccl—照明散熱冷負(fù)荷系數(shù),根據(jù)不同的空調(diào)運行時間開燈時間和開燈后的小時數(shù),查表。(6)設(shè)備和用具顯熱形成的冷負(fù)荷可按式3-7計算:Qc=QsCLQ(3-7)Qc——設(shè)備和用具顯熱形成的冷負(fù)荷,W;Qs——設(shè)備和用具實際顯熱散熱量,W;CLQ——設(shè)備和用具顯熱散熱冷負(fù)荷系數(shù),由于系統(tǒng)不連續(xù)運行,則CLQ=1.0。其中對于電動設(shè)備功率,由于工藝設(shè)備及電動機均在室內(nèi),所以可根據(jù)式3-8計算:Q=1000××××N/η(3-8)N——設(shè)備功率,W;——利用系數(shù);——同時使用系數(shù);——負(fù)荷系數(shù);η——電動機負(fù)荷系數(shù)(7)人體顯熱散熱形成的冷負(fù)荷可按式3-9計算:(3-9)——不同室溫和勞動性質(zhì)成年男子顯熱散熱量,W;——室內(nèi)全部人數(shù);——群集系數(shù);——人體負(fù)荷強度系數(shù)。(8)人體潛熱散熱形成的冷負(fù)荷可按式3-10計算:(3-10)——不同室溫和勞動性質(zhì)成年男子潛熱散熱量,W;——室內(nèi)全部人數(shù);——群集系數(shù)。(9)新風(fēng)冷負(fù)荷Qx=md×新風(fēng)量(iw-in)/3.6(3-11)md—夏季空調(diào)室外計算干球溫度下的空氣密度(kg/m3);iw—夏季室外計算參數(shù)下的焓值(kj/kg);in—室內(nèi)空氣的焓值(kj/kg)。3.1.2冷濕負(fù)荷計算實例以下為302房間的詳細(xì)負(fù)荷計算表:3002[KTV2]小計冷負(fù)荷(W)276.526.1302.6646.6720.5881.21232.11595.61684.41526.9723.6381.8370新風(fēng)冷負(fù)荷(W)0000000000000總冷負(fù)荷(W)276.5302.6646.6691.4720.5881.21232.11595.61684.41526.9723.6381.8370濕負(fù)荷(kg/h)20.22新風(fēng)濕負(fù)荷(kg/h)0000000000000總濕負(fù)荷(kg/h)20.22冷指標(biāo)(W/m2)18.219.942.645.547.45881.1105110.9100.547.625.124.4新風(fēng)冷指標(biāo)(W/m2)0000000000000總冷指標(biāo)(W/m2)18.219.942.645.547.45881.1105110.9100.547.625.124.4總濕指標(biāo)(kg/hm2)0.010.010.010.010.010.010.010.010.010.010.010.010.01房間負(fù)荷的匯總表3-1。樓號樓層房間房間面積工程負(fù)荷最大值時刻(15點)的各項負(fù)荷值房間最大負(fù)荷總冷負(fù)荷新風(fēng)冷負(fù)荷總濕負(fù)荷新風(fēng)濕負(fù)荷總冷指標(biāo)新風(fēng)冷指標(biāo)總濕指標(biāo)新風(fēng)量m2WWkg/hkg/hW/m2W/m2kg/hm2m3/hW1號樓1層1001[辦公1]116.648809.901.63075.500.0109016.621002[辦公2]21.5645.700.2703000.010654.111003[商務(wù)中心1]30.72930.300.38030.300.010942.831004[辦公3]14.14464.700.16032.900.010471.941005[行李]14.14581.900.22041.100.020589.671006[辦公4]12.85464.700.16036.200.010471.941007[辦公5]14.31555.200.22038.800.020563.031008[辦公6]56.792913.200.87051.300.0203043.681009[商務(wù)中心2]34.241832.800.16053.50001955.721010[茶室]392.83104118.4097.54026500.250104273.41011[會議室]129.5676501.63052.200.0106764.981012[衛(wèi)生間]39.91965.400.54049.300.0101965.371013[走廊及商業(yè)]40311571.109.08028.700.02011634.481014[消防控制中心]201149.400.11057.500.0101223.222層2001[小餐廳1]29.596045.703.110204.300.1106045.72002[小餐廳2]26.56454502.80171.100.1104666.722003[小餐廳3]21.52715.702.340126.300.1102737.562004[大餐廳]198.4429916.2021.490150.800.11030477.852005[小餐廳4]19.712334.102.020118.400.102349.032006[小餐廳5]29.534905.303.110166.100.1105029.722007[小餐廳6]23.24786.600.33033.800.010806.422008[小餐廳7]34.875178.703.740148.500.1105408.982009[小餐廳8]40.92588904.360143.900.1106103.442010[小餐廳9]16.98583.700.22034.400.010601.842011[小餐廳10]16.512448.401.710148.300.102595.092012[小餐廳11]16.532330.501.71014100.102404.262013[小餐廳12]19.712334.102.020118.400.102349.032014[小餐廳13]48.886062.905.3012400.1106101.082015[廚房1]126.118377.9013.710145.700.11018377.892016[廚房2]31.033757.903.270121.100.1103781.762017[廚房3]98.9513182.8010.750133.200.11014950.282018[廚房4]27.743394.802.960122.400.1103416.232019[走廊]403.83812.702.1709.400.01038422020[消防控制中心]201814.700.11090.700.0101814.742021[大餐廳]48.77423.805.30152.400.1107808.393層3001[KTV1]15.191585.300.220104.400.0101676.463002[KTV2]15.191595.600.22010500.0101684.353003[KTV3]15.131595.600.220105.500.0101684.353004[KTV4]15.131595.600.220105.500.0101684.353005[KTV5]9.43803.700.16085.200.020803.713006[KTV6]8.63374.200.11043.400.010380.863007[KTV7]12.74464.700.16036.500.010471.943008[KTV8]24.48736.100.33030.100.010745.193009[KTV10]21.5775.500.33036.100.020789.413010[棋牌1]13.46153200.220113.800.0201618.933011[棋牌2]7.01374.200.11053.400.020380.863012[棋牌3]8.04374.200.11046.500.010380.863013[棋牌4]11.24464.700.16041.300.010471.943014[棋牌5]13.78555.200.22040.300.020563.033015[包房1]15.191595.600.22010500.0101684.353016[包房2]12.65464.700.16036.700.010471.943017[包房3]14.5555.200.22038.300.010563.033018[包房4]14.5555.200.22038.300.010563.033019[包房5]22.522827.800.110125.60003034.613020[包房6]30.311581.800.43052.200.0101804.873021[包房7]34.87192200.49055.100.0102201.453022[包房8]23.422962.701.410126.500.0603025.43023[包房9]23.591380.600.33058.500.0101587.543024[包房10]21.5758.600.27035.300.010759.853025[包房11]20.131227.300.2706100.0101416.093026[包房12]32.711222.700.43037.400.0101268.433027[包房13]24.683583.100.330145.200.0103637.923028[包房14]19.08154300.27080.900.0101620.983029[桑拿前廳]56.24736.100.33013.100.010745.193030[休息1]6.8374.200.1105500.020380.863031[更衣]88.23349.401.1903800.0103349.393032[更衣]20.9645.700.27030.900.010654.113033[桑拿]348.810407.804.89029.800.01013318.513034[衛(wèi)生間]39.91422.500.22035.700.0101422.463035[消防控制中心]23.71684.400.43071.100.0201684.444層4030[客房1]29.481974.600.110670002029.174031[客房2]28.131557.800.11055.40001655.764032[客房3]28.271402.600.11049.60001487.624033[客房4]27.771414.600.11050.90001502.194034[客房5]28.081414.600.11050.40001502.194035[客房6]28.081414.600.11050.40001502.194036[客房7]29.8222400.11074.60002224.034037[客房8]34.61083.800.11031.30001294.764038[客房9]23.57101100.11042.90001229.624039[客房10]23.63798.100.11033.8000928.164040[客房11]21.05731.100.11034.700.010826.724041[客房12]29.2730.600.11025000826.494042[客房13]29.941566.800.11052.300018904043[客房14]28.081597.200.11056.90001692.184044[客房15]28.08676.300.11024.10001447.164045[客房16]28.081557.800.11055.50001655.764046[客房17]27.77676.300.11024.40001447.164047[客房18]28.271597.200.11056.50001692.184048[客房19]28.13676.300.110240001447.164049[客房20]29.481098.500.11037.30001744.414050[客房21]21.15941.400.11044.500.010941.444051[管理室2]20.46941.400.1104600.010941.444052[消毒室]8.46674.300.11079.700.010674.344053[儲藏室]18.33809.500.11044.200.010809.484054[管理室1]19.6809.500.11041.300.010809.484055[客房26]20.16809.500.11040.200.010809.484056[客房22]29.3374.200.11012.8000380.864057[客房24]28.6374.200.11013.1000380.864058[客房25]30.1374.200.11012.4000380.864059[客房27]29.3374.200.11012.8000380.864060[客房28]28.5374.200.11013.1000380.864061[客房29]28374.200.11013.4000380.864062[客房30]29.2374.200.11012.8000380.864063[客房31]28.081414.600.11050.40001502.194064[走廊]194.272200.701.18011.300.0102226.084065[消防控制中心]23.71684.400.43071.100.0201684.445層5030[客房1]29.481974.600.110670002029.175031[客房2]28.131557.800.11055.40001655.765032[客房3]28.271402.600.11049.60001487.625033[客房4]27.771414.600.11050.90001502.195034[客房5]28.081414.600.11050.40001502.195035[客房6]28.081414.600.11050.40001502.195036[客房7]29.8222400.11074.60002224.035037[客房8]34.61083.800.11031.30001294.765038[客房9]23.57101100.11042.90001229.625039[客房10]23.63798.100.11033.8000928.165040[客房11]21.05731.100.11034.700.010826.725041[客房12]29.2730.600.11025000826.495042[客房13]29.941566.800.11052.300018905043[客房14]28.081597.200.11056.90001692.185044[客房15]28.08676.300.11024.10001447.165045[客房16]28.081557.800.11055.50001655.765046[客房17]27.77676.300.11024.40001447.165047[客房18]28.271597.200.11056.50001692.185048[客房19]28.13676.300.110240001447.165049[客房20]29.481098.500.11037.30001744.415050[客房21]21.15941.400.11044.500.010941.445051[管理室2]20.46941.400.1104600.010941.445052[消毒室]8.46674.300.11079.700.010674.345053[儲藏室]18.33809.500.11044.200.010809.485054[管理室1]19.6809.500.11041.300.010809.485055[客房26]20.16809.500.11040.200.010809.485056[客房22]29.3374.200.11012.8000380.865057[客房24]28.6374.200.11013.1000380.865058[客房25]30.1374.200.11012.4000380.865059[客房27]29.3374.200.11012.8000380.865060[客房28]28.5374.200.11013.1000380.865061[客房29]28374.200.11013.4000380.865062[客房30]29.2374.200.11012.8000380.865063[客房31]28.081414.600.11050.40001502.195064[走廊]194.271897.900.7109.80001923.56層6030[客房1]29.481974.600.110670002029.176031[客房2]28.131557.800.11055.40001655.766032[客房3]28.271402.600.11049.60001487.626033[客房4]27.771414.600.11050.90001502.196034[客房5]28.081414.600.11050.40001502.196035[客房6]28.081414.600.11050.40001502.196036[客房7]29.8222400.11074.60002224.036037[客房8]34.61083.800.11031.30001294.766038[客房9]23.57101100.11042.90001229.626039[客房10]23.63798.100.11033.8000928.166040[客房11]21.05731.100.11034.700.010826.726041[客房12]29.2730.600.11025000826.496042[客房13]29.941566.800.11052.300018906043[客房14]28.081597.200.11056.90001692.186044[客房15]28.08676.300.11024.10001447.166045[客房16]28.081557.800.11055.50001655.766046[客房17]27.77676.300.11024.40001447.166047[客房18]28.271597.200.11056.50001692.186048[客房19]28.13676.300.110240001447.166049[客房20]29.481098.500.11037.30001744.416050[客房21]21.15941.400.11044.500.010941.446051[管理室2]20.46941.400.1104600.010941.446052[消毒室]8.46674.300.11079.700.010674.346053[儲藏室]18.33809.500.11044.200.010809.486054[管理室1]19.6809.500.11041.300.010809.486055[客房26]20.16809.500.11040.200.010809.486056[客房22]29.3374.200.11012.8000380.866057[客房24]28.6374.200.11013.1000380.866058[客房25]30.1374.200.11012.4000380.866059[客房27]29.3374.200.11012.8000380.866060[客房28]28.5374.200.11013.1000380.866061[客房29]28374.200.11013.4000380.866062[客房30]29.2374.200.11012.8000380.866063[客房31]28.081414.600.11050.40001502.196064[走廊]194.271897.900.7109.80001923.57層7037[客房1]29.481974.600.110670002029.177038[客房2]28.131557.800.11055.40001655.767039[客房3]28.271402.600.11049.60001487.627040[客房4]27.771414.600.11050.90001502.197041[客房5]28.081414.600.11050.40001502.197042[客房6]28.081414.600.11050.40001502.197043[客房7]29.8222400.11074.60002224.037044[客房8]34.61083.800.11031.30001294.767045[客房9]23.57101100.11042.90001229.627046[客房10]23.63798.100.11033.8000928.167047[客房11]21.05731.100.11034.700.010826.727048[客房12]29.2730.600.11025000826.497049[客房13]29.941566.800.11052.300018907050[客房14]28.081597.200.11056.90001692.187051[客房15]28.08676.300.11024.10001447.167052[客房16]28.081557.800.11055.50001655.767053[客房17]27.77676.300.11024.40001447.167054[客房18]28.271597.200.11056.50001692.187055[客房19]28.13676.300.110240001447.167056[客房20]29.481098.500.11037.30001744.417057[客房21]21.15941.400.11044.500.010941.447058[管理室2]20.46941.400.1104600.010941.447059[消毒室]8.46674.300.11079.700.010674.347060[儲藏室]18.33809.500.11044.200.010809.487061[管理室1]19.6809.500.11041.300.010809.487062[客房26]20.16809.500.11040.200.010809.487063[客房31]28.081414.600.11050.40001502.197064[走廊]194.271897.900.7109.80001923.58層8037[客房1]29.482172.900.11073.70002269.328038[客房2]28.13174700.11062.10001884.918039[客房3]28.271592.800.11056.30001717.918040[客房4]27.771601.400.11057.70001728.418041[客房5]28.081603.500.11057.10001730.938042[客房6]28.081603.500.11057.10001730.938043[客房7]29.82424.500.11081.40002424.478044[客房8]34.61316.600.11038.10001421.788045[客房9]23.571169.500.11049.60001316.158046[客房10]23.6395700.11040.50001018.748047[客房11]21.05872.700.11041.500.010914.768048[客房12]29.292700.11031.7000956.588049[客房13]29.941768.200.11059.10001971.068050[客房14]28.081786.100.11063.60001920.928051[客房15]28.08865.200.11030.80001468.098052[客房16]28.081746.700.11062.20001884.58053[客房17]27.77863.100.11031.10001467.868054[客房18]28.271787.400.11063.20001922.478055[客房19]28.13865.500.11030.80001468.128056[客房20]29.481296.800.110440001766.378057[客房21]21.151083.700.11051.200.0101083.78058[管理室2]20.461079.100.11052.700.0101079.068059[消毒室]8.46731.200.11086.400.010731.248060[儲藏室]18.33932.800.11050.900.010932.778061[管理室1]19.6941.300.1104800.010941.328062[客房24]20.16945.100.11046.900.010945.088063[客房22]21.569500032.3000695.058064[走廊]194.273204.600.71016.50003506.071號樓小計8761.1506669.30242.13057.800.030506669.3工程合計8761.1506669.30242.13057.800.030506669.3表3-1建筑其它房間負(fù)荷匯總表3.2濕負(fù)荷計算空調(diào)房間的濕負(fù)荷和冷負(fù)荷一樣,對空調(diào)系統(tǒng)的規(guī)模有著決定性的影響。濕負(fù)荷包括人體濕負(fù)荷、化學(xué)反應(yīng)的濕負(fù)荷以及水槽、設(shè)備、食品的濕負(fù)荷和新風(fēng)濕負(fù)荷四部分濕負(fù)荷,而客房的濕負(fù)荷主要是人體散濕所形成的濕負(fù)荷和新風(fēng)濕負(fù)荷,下面以201診斷室為例來論述:3.2.1人體濕負(fù)荷的計算人體濕負(fù)荷計算公式:=××n′(3-8)單位散濕量,取184g/(h·人);人數(shù),取2;n′群集系數(shù),取0.93;則辦公室的人體濕負(fù)荷為=2×0.93×184=171.12g/h=0.0475g/s。3.3圍護結(jié)構(gòu)的節(jié)能設(shè)計措施和依據(jù)(1)墻體保溫的形式目前,外墻的保溫形式主要有:外墻內(nèi)保溫、夾心(層)保溫及外墻外保溫。外墻內(nèi)保溫是將絕熱材料復(fù)合在承重墻(外墻)內(nèi)側(cè),夾心(層)保溫是將絕熱材料設(shè)置在=外墻中間,外墻外保溫是將絕熱材料復(fù)合在承重墻(外墻)外側(cè),各種形式的墻體保溫都有其特點和長處,但與外墻內(nèi)保溫、夾心(層)保溫相比,外墻外保溫有相對的優(yōu)勢。主要表現(xiàn)在以下幾方面:①外保溫可以盡量避免產(chǎn)生熱橋。采用內(nèi)保溫時,主體墻越薄,保溫層越厚時,熱橋的問題就越趨于嚴(yán)重。而采用夾心(層)保溫時容易產(chǎn)生熱橋。②在進行外保溫后,室溫較為穩(wěn)定,可提高舒適感。③采用外保溫后,可減緩墻體溫度的波動,減少熱應(yīng)力,使主體墻體產(chǎn)生裂縫、變形、破壞的危險減輕,使用壽命延長。④采用內(nèi)保溫的墻體上難以吊掛物件,還會減少使用面積。外保溫則可避免這些問題發(fā)生。此外,外墻外保溫形式可以使建筑相對美觀。當(dāng)然,目前外保溫技術(shù)并不是十分完善的,它還存在許多需要研究的技術(shù)問題,它的使用壽命和安全性有待進一步的研究和提高。(2)外墻外保溫體系的基本要求:①保溫可靠:是指保溫層應(yīng)提供足夠大的傳熱阻,設(shè)計和施工中盡量減少熱橋的影響,使復(fù)合外墻的平均傳熱系數(shù)符合國家節(jié)能標(biāo)準(zhǔn)的要求。保溫效能是外墻外保溫質(zhì)量的一個關(guān)鍵性的指標(biāo)。為此,應(yīng)按相關(guān)的節(jié)能設(shè)計標(biāo)準(zhǔn)進行設(shè)計,采取適當(dāng)?shù)慕ㄖ?gòu)造措施,避免某些局部熱橋的產(chǎn)生。②聯(lián)結(jié)安全:是指外保溫系統(tǒng)與基層墻體必須有足夠高的聯(lián)結(jié)強度,絕不允許在長期使用中出現(xiàn)剝落、脫離現(xiàn)象。與基層牢固結(jié)合,是保證外保溫層穩(wěn)定性的基本環(huán)節(jié)。其粘結(jié)劑必須是耐水的,機械錨固件應(yīng)不致被腐蝕。③表面防裂:外保溫系統(tǒng)的外飾面和防護層使用環(huán)境較惡劣,外保溫墻體應(yīng)能耐受當(dāng)?shù)刈顕?yán)酷的氣候及其變化。應(yīng)采取措施,避免墻體產(chǎn)生裂縫。外墻外保溫體系應(yīng)能耐受一般搬運物品及人體的碰撞。④使用耐久:外墻外保溫構(gòu)造的平均壽命,在正常使用與維修的條件下,應(yīng)達到25年以上,這就要求:外墻外保溫體系的各種組成材料,應(yīng)該具有化學(xué)的與物理的穩(wěn)定性。所有的材料所具有的性能,應(yīng)做到在結(jié)構(gòu)的壽命期內(nèi)。所用的材料相互間應(yīng)該是彼此相容的。第四章方案選擇和分析河南理工大學(xué)本科畢業(yè)設(shè)計(論文)第四章方案選擇和分析第四章方案選擇和分析4.1常見空調(diào)方式分析比較中央空調(diào)系統(tǒng)從冷卻介質(zhì)上可劃分為:水系統(tǒng)中央空調(diào)和風(fēng)冷熱泵型中央空調(diào);若從動力來源又可分為:吸收式制冷和電制冷兩類?,F(xiàn)今市場廣泛使用的三個空調(diào)方式:方式一:風(fēng)冷熱泵式中央空調(diào)系統(tǒng)方式二:電制冷冷水機組方式三:溴化鋰?yán)渌畽C組或直燃機具體情況分析如下:4.1.1方式一風(fēng)冷熱泵式中央空調(diào)方法主要分為水系統(tǒng)和直接蒸發(fā)式兩種系統(tǒng)形式。其中風(fēng)冷熱泵式中央空調(diào)水系統(tǒng),夏季使用時主機制出冷水后通過末端風(fēng)機盤管及新風(fēng)機組送到房間內(nèi);冬季則利用熱泵原理制熱水。無水的為氟利昂直接蒸發(fā)式,它是由一臺室外機帶許多個室內(nèi)機的一種形式,夏季用來制冷,冬季用來采暖。如果系統(tǒng)的容量通過變頻方式調(diào)節(jié),即為變冷媒流量系統(tǒng)(VRF)。VRF系統(tǒng)只用“電”這一種能源,不用建機房、不需鍋爐、水泵、冷卻塔等任何附屬設(shè)備,也不需專人管理,室外機放于房頂或地面。優(yōu)點:1、不需建機房,不用專人管理,使用非常方便;2、一機兩用,生產(chǎn)技術(shù)水平較高,壽命較長;3、整個空調(diào)系統(tǒng)較簡單,沒有冷卻水系統(tǒng),設(shè)備種類很少,不需要其它企業(yè)生產(chǎn)的附屬設(shè)備,因此故障因素較少,維修更換簡單,設(shè)備的后期投資很低。同時,機組可集中放在屋頂或平臺上,勿需建機房、油罐和鍋爐房;4、控制先進方便??扇孔钥亍H秉c:當(dāng)室外空氣濕度大于70%,溫度在3~5℃范圍內(nèi)時,設(shè)備結(jié)霜問題嚴(yán)重。室外氣溫較低特別是0℃以下時,制熱效果較差,應(yīng)設(shè)置相應(yīng)的輔助熱源。4.1.2方式二電制冷冷水機組方法電制冷冷水機為冷源,配以末端風(fēng)機盤管和新風(fēng)機組,需水處理設(shè)備、水泵、冷卻塔等附屬設(shè)備,要建機房和配備專門操作管理人員。此外,還需配備鍋爐和鍋爐房,以用于提供熱源。就目前市場的情況,分為離心式、螺桿式和活塞式?;钊嚼渌畽C組具有悠久的生產(chǎn)歷史,技術(shù)十分成熟,制造簡單、價格便宜,缺點是單機容量比較小,制冷效率比較低,工作部件較多,維修工作量比較大,不滿足本設(shè)計大負(fù)荷的要求,故不予考慮。離心式冷水機組單機制冷量大,維護費用低,而且能經(jīng)濟方便地調(diào)節(jié)制冷量,但當(dāng)制冷負(fù)荷很小時,將會產(chǎn)生“喘振”現(xiàn)象?!按瘛睍龃髾C組運行時的震動和噪聲,嚴(yán)重時有可能損壞機器。螺桿式冷水機組壓縮機結(jié)構(gòu)簡單、緊湊,維修工作量小,運行平穩(wěn)安全可靠,操作方便,可以再較高的壓縮比工況下運行。對于濕壓縮不敏感,可以實現(xiàn)10%—100%范圍內(nèi)無級能量調(diào)節(jié)。由于廣州地區(qū)的濕度較大,可以借以參考此種機型。它是以電為動力源,以氟里昂為制冷劑,以水為載體。其制冷原理是液態(tài)氟里昂可以吸收冷凍水中熱量,變成氣態(tài),氣態(tài)制冷劑(即氟里昂)在通過壓縮機時壓縮變成液態(tài),過多的熱量在通過冷凝器時被其中的冷卻水帶走,釋放到大氣中去。它是通過機械運轉(zhuǎn)來達到制冷效果的,而溴化鋰機組是通過物理變化反應(yīng)達到目的的。優(yōu)點:1、電制冷技術(shù)已有較長的歷史,技術(shù)成熟度較高,與溴化鋰技術(shù)相比,機械運轉(zhuǎn)簡捷明快,機組壽命較長(但末端系統(tǒng)的風(fēng)機盤管壽命一般為5-8年);2、對水質(zhì)的要求比溴化鋰機組低;3、能效比較高;4、目前市場中的故障反應(yīng)較少。缺點:1、主機只能制冷,要配備鍋爐和建鍋爐房供暖。環(huán)保部門要求很高。但是因為廣州地區(qū)不要求供熱,所以優(yōu)先采用此種制冷方式;2、用電容量大;3、整個空調(diào)系統(tǒng)與溴化鋰機組一樣,需要較多的其它設(shè)備(種類同溴化鋰),運行管理較復(fù)雜,故障因素較多;4、主機噪聲較大(一般為80分貝)。4.1.3方式三溴化鋰?yán)渌畽C組方法由溴化鋰機組配以風(fēng)機盤管末端和新風(fēng),同時還需水處理設(shè)備、水泵、冷卻塔等附屬設(shè)備,并要建機房和配備專門的操作管理人員。溴化鋰機以水為制冷劑,以溴化鋰為吸收劑,其制冷原理是在真空環(huán)境下,水可以在溫度很低時蒸發(fā);而溴化鋰是一種吸水性極強的物質(zhì),可以將水蒸氣吸收;變稀的溴化鋰溶液被燃燒加熱使水分離出來,再次進行蒸發(fā),而濃溶液又再次進行吸收。蒸發(fā)的結(jié)果使空調(diào)水變冷了,蒸發(fā)出來的熱量被冷卻水釋放到大氣中去。優(yōu)點:1、節(jié)省電力及配電設(shè)施費用。不含CFCs,環(huán)保效果好;2、直燃機一機二用,既可制冷也可供熱;3、由于以熱交換做動力,震動和機械磨損較少,所以噪聲較低(一般70分貝左右)。缺點:1、工藝要求控制監(jiān)測內(nèi)容多,例如:真空情況、溶液濃度、結(jié)晶、結(jié)垢、水質(zhì)等,即對設(shè)備制造質(zhì)量和使用管理要求十分嚴(yán)格,否則一旦出現(xiàn)腐蝕、結(jié)晶、結(jié)垢等情況,將引起冷量衰減和大幅度縮短設(shè)備壽命;2、冷量衰減現(xiàn)象比較嚴(yán)重,而且因素較多,例如:噴嘴或滴淋孔堵塞、水垢、灰垢、真空不良等都會造成衰減;3、整個空調(diào)系統(tǒng)中主機以外的其它設(shè)備較多,如風(fēng)機盤管(壽命一般為8年)、新風(fēng)機組、冷卻塔、水泵、水處理設(shè)備等,運行管理較復(fù)雜,容易在室內(nèi)造成水的跑、冒、滴、漏現(xiàn)象。而且附屬設(shè)備的生產(chǎn)企業(yè)各不相同,技術(shù)水平不一,維修不便;4、運行費用高,直燃機號稱“油老虎”,是所有中央空調(diào)中運行費用最高的,而蒸汽機由于環(huán)保要求,鍋爐增容是一個難題。4.2制冷方案的選用原則及其總裝機容量本建筑為廣東輕工大廈要求舒適性空氣調(diào)節(jié),各樓層套件負(fù)荷有部分差別,差別不是很大,針對第一層水利失衡需要加閥門調(diào)節(jié)。負(fù)荷計算采用逐時計算法,且在計算中所有房間新風(fēng)負(fù)荷均包括在內(nèi),按照總冷負(fù)荷509.4KW選取機組設(shè)備。選擇2臺制冷機組,避免選3臺時占地操作不便,避免1臺時出現(xiàn)故障系統(tǒng)癱瘓。這樣當(dāng)冷負(fù)荷減少時,可以部分機組停止運行,便于制冷量的調(diào)節(jié)。在需要全部運轉(zhuǎn)時,如果其中一臺發(fā)生故障,停機檢修,仍有一臺或兩臺繼續(xù)運行,室內(nèi)空氣參數(shù)不致波動太大。本設(shè)計中,擬選用兩臺冷水機組,因機組工作環(huán)境好符合穩(wěn)定且工作負(fù)荷接近額定負(fù)載,不設(shè)備用機組,制冷機組總?cè)萘靠砂词?-1計算。(4-1)——制冷機組總?cè)萘?,kW;——建筑物的同時使用系數(shù),與建筑物使用性質(zhì)、功能、規(guī)范、等級及經(jīng)營管理等多種因素有關(guān),一般在0.6~1.0范圍內(nèi),取0.9;——冷損失系數(shù),可取1.05~1.15,取1.1;——事故備用量修正系數(shù),當(dāng)只有2~3臺冷水機組時,需考慮在高峰負(fù)荷期間有一臺機組因故障停機時,還可維持75%左右的負(fù)荷,對于本工程只選用一臺制冷機組,故可不考慮此系數(shù);——考慮設(shè)備傳熱及出力效率降低的系數(shù),取1.1;——制冷系統(tǒng)設(shè)計負(fù)荷,232KW。對于各類制冷機組的比較如下表。表4-1水冷式冷水機組選型范圍單機名義工況制冷量(KW)冷水機組機型≤116往復(fù)式、渦旋式116~700往復(fù)式螺桿式700~1054螺桿式1054~1758螺桿式離心式≥1758離心式制冷機組總?cè)萘繛?09.4KW,從表中參考選國產(chǎn)螺桿式冷水機組MQN-80AD機型。第五章空調(diào)方式的確定河南理工大學(xué)本科畢業(yè)設(shè)計(論文)第五章空調(diào)方式的確定第五章空調(diào)方式的確定5.1空氣處理設(shè)備的設(shè)置確定表5-1集中式系統(tǒng)與半集中式系統(tǒng)的特點比較集中式系統(tǒng)特點半集中式系統(tǒng)特點1、房間面積大或多層、多濕而熱濕負(fù)荷情況類似
2、新風(fēng)量變化大
3、室內(nèi)溫度、濕度、潔凈度、噪聲、振動等的要求
4、全年多工況節(jié)能1、面積大,但風(fēng)管不易布置
2、多層多室,層高較低。熱濕負(fù)荷不一致或參數(shù)要求不同
3、室內(nèi)溫濕度要求t≥±1℃,φ≥±10%
4、要求各室內(nèi)空氣不要串通
5、要求調(diào)節(jié)風(fēng)量5.2處理空調(diào)負(fù)荷輸送介質(zhì)分類的確定表5-2全空氣系統(tǒng)與空氣-水系統(tǒng)方案比較表比較項目全空氣系統(tǒng)空氣-水系統(tǒng)設(shè)備布置與機房空調(diào)與制冷設(shè)備可以集中布置在機房機房面積較大層高較高有時可以布置在屋頂或安設(shè)在車間柱間平臺上只需要新風(fēng)空調(diào)機房、機房面積小風(fēng)機盤管可以設(shè)在空調(diào)機房內(nèi)分散布置、敷設(shè)各種管線較麻煩風(fēng)管系統(tǒng)1.空調(diào)送回風(fēng)管系統(tǒng)復(fù)雜、布置困難2.支風(fēng)管和風(fēng)口較多時不易均衡調(diào)節(jié)風(fēng)量放室內(nèi)時不接送、回風(fēng)管當(dāng)和新風(fēng)系統(tǒng)聯(lián)合使用時,新風(fēng)管較小節(jié)能與經(jīng)濟性1、可以根據(jù)室外氣象參數(shù)的變化和室內(nèi)負(fù)荷變化實現(xiàn)全年多工況節(jié)能運行調(diào)節(jié),充分利用室外新風(fēng)減少與避免冷熱抵消,減少冷凍機運行時間2、對熱濕負(fù)荷變化不一致或室內(nèi)參數(shù)不同的多房間不經(jīng)濟靈活性大、節(jié)能效果好,可根據(jù)各室負(fù)荷情況自我調(diào)節(jié)盤管冬夏兼用,內(nèi)避容易結(jié)垢,降低傳熱效率無法實現(xiàn)全年多工況節(jié)能運行使用壽命使用壽命長使用壽命較長安裝設(shè)備與風(fēng)管的安裝工作量大周期長安裝投產(chǎn)較快,介于集中式空調(diào)系統(tǒng)與單元式空調(diào)器之間維護運行空調(diào)與制冷設(shè)備集中安設(shè)在機房便于管理和維護布置分散維護管理不方便,水系統(tǒng)布置復(fù)雜、易漏水溫濕度控制可以嚴(yán)格地控制室內(nèi)溫度和室內(nèi)相對濕度對室內(nèi)溫度要求嚴(yán)格時難于滿足空氣過濾與凈化可以采用初效、中效和高效過濾器,滿足室內(nèi)空氣清潔度的不同要求,采用噴水室時水與空氣直接接觸易受污染,須常換水過濾性能差,室內(nèi)清潔度要求較高時難于滿足消聲與隔振可以有效地采取消防和隔振措施必須采用低噪聲風(fēng)機才能保證室內(nèi)要求風(fēng)管互相串通空調(diào)房間之間有風(fēng)管連通,使各房間互相污染,當(dāng)發(fā)生火災(zāi)時會通過風(fēng)管迅速蔓延各空調(diào)房間之間不會互相污染考慮到建筑的用途是住宅,綜上所述,住宅選擇半集中式系統(tǒng)。第六章空調(diào)布置河南理工大學(xué)本科畢業(yè)設(shè)計(論文)第六章空調(diào)布置第六章空調(diào)布置6.1空調(diào)布置方式空氣調(diào)節(jié)系統(tǒng)的作用是建立和保持建筑物內(nèi)的人工環(huán)境,目的是為了室內(nèi)人員的舒適和健康或為了生產(chǎn)過程的順利進行,提高生產(chǎn)效率??照{(diào)過程中必須采用的基本措施是加熱、加濕、冷卻或去濕。它由冷熱源、空氣處理設(shè)備、風(fēng)機、管道等組成,包括一些必要的輔助設(shè)備??照{(diào)方案一旦確定就要進行選型計算。6.2各類房間空調(diào)方案的確定在本設(shè)計中,建筑為餐飲娛樂一體的商務(wù)場所,要有良好的控制和調(diào)節(jié)。住宅是不同年齡、不同職業(yè)和不同生活要求的人生活和休息的地方。不同住宅的生活方式不同,對房間舒適度的要求不同,對空調(diào)設(shè)備運行的時間要求也不同。即不同住戶有自主控制調(diào)節(jié)的要求,不同房間也有隨意控制調(diào)節(jié)的要求。因此,住宅空調(diào)系統(tǒng)必須具有有效的控制手段和靈活的調(diào)節(jié)性能??照{(diào)負(fù)荷構(gòu)成不同于一般空調(diào)建筑,具有波動性大、同時使有系數(shù)低的特點,造成室內(nèi)空調(diào)設(shè)備裝機容量大而主機裝機容量小??照{(diào)設(shè)備必須具備較好的部分負(fù)荷性能。住宅空調(diào)投資和運行費要盡可能少,住宅空調(diào)系統(tǒng)要求可靠性高且維修方便。也就決定選螺桿式制冷機組,為風(fēng)機盤管加新風(fēng)系統(tǒng)的設(shè)計方案。以下對風(fēng)機盤管做一下介紹。夏季,空調(diào)冷源供給7℃的冷水,12℃的回水。新風(fēng)供給方式采用獨立的新風(fēng)系統(tǒng),每層每戶有自己獨立的新風(fēng)干管,新風(fēng)機組布置在每層的新風(fēng)機房內(nèi),這樣可以保證空調(diào)房間內(nèi)濕度與新風(fēng)量的要求。設(shè)計中選用的風(fēng)機盤管全部帶有后回風(fēng)口。風(fēng)機盤管的水系統(tǒng)采用兩管制,每層都有獨立的供、回水水平干管,立管位于靠近墻角的位置布置,為節(jié)省管道,水系統(tǒng)布置為異程式,并在水系統(tǒng)的最高點和回水出口處設(shè)手動排氣閥,用于排除風(fēng)機盤管內(nèi)的空氣。風(fēng)機盤管的凝結(jié)水排至就近的衛(wèi)生間內(nèi),凝結(jié)水支管坡向排水方向保持0.003的安裝坡度。風(fēng)機盤管與新風(fēng)管道并排布置在房間走道的上方吊頂內(nèi),新風(fēng)口緊貼風(fēng)機盤管。新風(fēng)與風(fēng)機盤管風(fēng)口相互獨立,通過條縫型百葉送風(fēng)口將空氣送入室內(nèi)。6.3水系統(tǒng)的布置表6-1水系統(tǒng)比較表類型閉式開式特征管路系統(tǒng)不與大氣相接管路系統(tǒng)與大氣相通僅在系統(tǒng)最高點設(shè)置膨脹空調(diào)系統(tǒng)風(fēng)機盤管和有水冷式冷器的系統(tǒng)有噴水室的系統(tǒng)優(yōu)點1.管道與設(shè)備不易腐蝕與蓄熱水池連接比較簡單,冷水箱有一定蓄冷能力,可以減少開啟冷凍機的時間,增加能量調(diào)節(jié)能力,且冷水溫度波動可以小一些2.不需克服靜水壓力,水泵壓力,功率均低3.系統(tǒng)簡單缺點蓄冷能力小,低負(fù)荷時冷凍機也需要經(jīng)常開動;膨脹水箱的補水有時需要加加壓水泵冷水與大氣接觸;易腐蝕管道;水泵要克服靜水壓力,耗電大,采用自流回水時回水管徑大因而投資較高些表6-2定變水量優(yōu)缺點比較表類型定流量變流量特征系統(tǒng)中的水量保持定值,負(fù)荷變化時改變供回水溫度來匹配供回水溫度保持定值,負(fù)荷變化時改變系統(tǒng)中的水量來匹配優(yōu)點系統(tǒng)簡單,操作方便。不需復(fù)雜的自控系統(tǒng)輸送能耗隨流量的減少而減低,配管設(shè)計可考慮同時使用系數(shù),管徑相應(yīng)減小缺點配管設(shè)計不能考慮同時使用系數(shù),輸送能耗始終處于最大值系統(tǒng)復(fù)雜。必須配自控系統(tǒng)表6-3同程和異程系統(tǒng)比較表類型同程異程特征供回水干管水流方向相同,經(jīng)過每一環(huán)路的管路長度相等供回水干管水流方向相反,經(jīng)過每一環(huán)路的管路長度不等優(yōu)點水量分配、調(diào)節(jié)方便。便于水力平衡。不需回程管,管道長度較短,管路簡單,投資較低。缺點需回程管,管道長度較長,投資較高。水量分配、調(diào)節(jié)難。不便于水力平衡。其中兩管制系統(tǒng)的優(yōu)點兩管制水系統(tǒng)是采用同一套供回水管路。夏季供冷水。由運行人員依據(jù)多數(shù)房間的需要決定,實行供熱與供冷的轉(zhuǎn)換。兩管系統(tǒng)具有管理方便,一次性投資較小等優(yōu)點。本設(shè)計對空調(diào)精度要求不是很高,故采用兩管制。而三管制是共用一根回水管,因此冷熱有混合損失,運行效率不高,而且系統(tǒng)水力工況復(fù)雜,難于運行。四管制初投資較高且多占空間。本設(shè)計采用兩管制、閉式、水平異程、一次泵、定流量系統(tǒng)。本建筑是普通建筑,采用雙管系統(tǒng)。6.4風(fēng)系統(tǒng)布置新風(fēng)系統(tǒng)的布置按照建筑要求和結(jié)構(gòu)特點,本著方便建議的原則。將室外新鮮空氣過濾后送入新風(fēng)機,新風(fēng)與冷凍水通過換熱器交換能量,同時因室內(nèi)正壓在向室外排出室內(nèi)污濁空氣,由新風(fēng)凈化室內(nèi)空氣。第七章末端設(shè)備的選擇河南理工大學(xué)本科畢業(yè)設(shè)計(論文)第七章末端設(shè)備的選擇第七章末端設(shè)備的選擇末端設(shè)備均按設(shè)備風(fēng)量來選擇,并用校核房間所需要的風(fēng)量。風(fēng)機盤管按夏季負(fù)荷進行選型。設(shè)計中可按名義制冷工況選取即可。冷凍水進口溫度7℃進出口溫差5℃風(fēng)機盤管全熱制冷量Qt≥(1+β1+β2)Qc。式中:β1:考慮積灰對風(fēng)機盤管傳熱影響的附加率,冬、夏兩用盤管取20%;β2:考慮風(fēng)機盤管間歇使用的附加率15%~20%。7.1空氣-水系統(tǒng)的新風(fēng)處理方案采用臥式暗裝風(fēng)機盤管,無靜壓型的標(biāo)準(zhǔn)風(fēng)機盤管,按風(fēng)機盤管中檔風(fēng)量下制冷量進行選型,但必須在風(fēng)管、送風(fēng)口、回風(fēng)口及風(fēng)口過濾器的總阻力小于無靜壓風(fēng)管的30pa的前提下。對于新風(fēng)處理的方式,在有條件的時候,盡量設(shè)置獨立新風(fēng),即通常所說的“風(fēng)機盤管加新風(fēng)系統(tǒng)”。此時應(yīng)注意,新風(fēng)處理狀態(tài)不同則室內(nèi)空氣狀態(tài)變化過程不同,新風(fēng)盤管機組和新風(fēng)機組在負(fù)荷的分配上也不同。在本設(shè)計中,用的是新風(fēng)處理到室內(nèi)等焓值,送入風(fēng)機盤管中,對這種處理過程做以下介紹??諝馓幚磉^程如圖所示,其特
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 中圖版(北京)八年級地理上冊2.2《主要的氣候類型》聽課評課記錄
- 人教版七年級地理上冊:1.1《地球和地球儀》聽課評課記錄3
- 2025年高性能鐵氧體一次料合作協(xié)議書
- 星球版地理八年級上冊《第一節(jié) 合理利用土地資源》聽課評課記錄3
- 人教版歷史八年級下冊第13課《香港和澳門的回歸》聽課評課記錄
- 魯教版地理七年級下冊9.1《自然特征與農(nóng)業(yè)》聽課評課記錄1
- 五年級數(shù)學(xué)下冊聽評課記錄《第4單元 3分?jǐn)?shù)的基本性質(zhì)》人教版
- 粵人版地理八年級上冊《第三節(jié) 水資源》聽課評課記錄1
- 湘教版數(shù)學(xué)七年級下冊1.3《二元一次方程組的應(yīng)用》聽評課記錄1
- 蘇科版九年級數(shù)學(xué)聽評課記錄:第80講期中期末串講
- 小學(xué)五年級英語20篇英文閱讀理解(答案附在最后)
- 學(xué)校安全隱患排查治理工作臺賬
- GB/T 8151.13-2012鋅精礦化學(xué)分析方法第13部分:鍺量的測定氫化物發(fā)生-原子熒光光譜法和苯芴酮分光光度法
- 2023年遼寧鐵道職業(yè)技術(shù)學(xué)院高職單招(英語)試題庫含答案解析
- GB/T 23800-2009有機熱載體熱穩(wěn)定性測定法
- T-SFSF 000012-2021 食品生產(chǎn)企業(yè)有害生物風(fēng)險管理指南
- 2023年上海市閔行區(qū)精神衛(wèi)生中心醫(yī)護人員招聘筆試題庫及答案解析
- 水庫工程施工組織設(shè)計
- 氣流粉碎機課件
- 梁若瑜著-十二宮六七二象書增注版
- SJG 74-2020 深圳市安裝工程消耗量定額-高清現(xiàn)行
評論
0/150
提交評論