1、實驗數據記錄與處理1、實驗原始數據記錄表、次序項 目123456789水蒸氣壓強MPa0.020.020.020.020.020.020.020.020.02空氣進口溫度t1°C32.730.328.024.622.121.420.82121.6空氣出口溫度t2°C74.172.971.970.770.470.771.972.674空氣進口處蒸汽溫度T1°C103.2103.2103.2103.2103.2103.2103.2103.2103.2空氣出口處蒸汽溫度T2°C102.3102.3102.3102.3102.3102.3102.3102.310

2、2.3空氣流量V(m3/h)23.022.021.018.515.012.6108.57空氣進口處密、3度卩(kg/m )1.15511.16441.17341.18691.19701.19981.20231.20151.1982空氣質量流量ms (kg/s)0.00740.00710.00680.00610.00500.00420.00340.00280.0023空氣流速U(m/s)31.791830.409629.027325.571720.733817.416413.822511.74929.6758計算公式:空氣進口處密度:10 5t124.5 10 3t11.2916空氣質量流量:m

3、s V空氣流速:U4Vd22、給熱系數K的計算空氣定性溫度t平均°C53.4051.6049.9547.6546.2546.0546.3546.8047.90定性溫度下的空氣密度kg/m31.07981.08601.09181.09991.10481.10571.10451.10291.0989冷、熱流體間的對數平均溫差 tm °C46.443548.179249.701451.857753.014553.071752.456451.885850.5873總給熱系數Kw/(m2 O151.704125.962120.948108.55990.97278.10065.1335

4、6.48248.132空氣定性溫度:t平均 -(t12t2) ( t60)空氣比熱:Cp 1005J/(kg°C)定性溫度下的空氣密度:= 10-5t平平均4.5 10 3t平均1.2916冷、熱流體間的對數平均溫差:tm(Ti t2) (T2 ti)T1 t2lnT2t1傳熱面積:Ad2l3.14 0.016 120.0502m對流傳熱系數:rnisC p(t2t1)A tm計算公式:3、近似法求給熱系數hh=K=103.1096w/(m2 -C)4、h理論值的計算對流給熱系數h w/(m2 °C)151.704125.962120.948108.55990.97278.

5、10065.13356.48248.132空氣黏度卩(10-5 Pas)1.87821.86651.85531.83871.82641.82301.82001.82101.8249空氣導熱系數入 W/(m K)0.02700.02680.02660.02630.02620.02610.02610.02610.0261雷諾數Re29243283092732924474200681689913421113659332普蘭特數Pr0.69970.69990.70030.70110.70170.70180.70200.70190.7017努賽爾數Nu78.063376.166572.684065.90

6、1355.644447.872339.997034.663029.4673努賽爾數理論值Nu'74.643472.654670.659164.717255.232848.143840.041035.102229.9122理論h'W/(m 2 ©125.767121.722117.577106.60590.30078.54365.20557.19748.859h各點的相對誤差%-4.72-3.48-2.86-1.82-0.740.560.111.251.481.95461.93811.92331.88061.80701.71461.66351.60131.53094.4

7、6604.45194.43664.38884.30254.22794.12784.05633.96計算公式:空氣粘度:(2 10 6ti2 5 10 3ti 1.7169) 10 5空氣導熱系數:2 1O-8t2 8 10 5t1 0.0244雷諾數:Redu普蘭特數:PrCp努賽爾數:Nu hd對于流體在圓形只管內做湍流時的對流傳熱系數若符合以下條件:Re1.0104 : 1.2 105,Pr 0.7:120,管長與管內徑之 丄60 , d貝U Nu O.O23Re0'8 Prn本實驗中,-d10.01662.560,而Re, Pr也基本在這個范圍內,n=0.4。所以可以用上述公式計

8、算Nu的理論值:Nu' 0.023Re08 Prn理論給熱系數:相對誤差:hNuh 'd100% h實驗結果與分析1、冷流體給熱系數的實驗計算值與理論值(Nu/Pr 0.40.023 Re0.8 )列表比較,計算各點誤差,并分析討論次序 項目、123456789努賽爾數Nu78.063376.166572.684065.901355.644447.872339.997034.663029.4673努賽爾數理論值Nu'74.643472.654670.659164.717255.232848.143840.041035.102229.9122對流給熱系數h151.7041

9、25.962120.948108.55990.97278.10065.13356.48248.132w/(m 2 ©理論h'W/(m2 ©125.767121.722117.577106.60590.30078.54365.20557.19748.859h各點的相對誤差%-4.72-3.48-2.86-1.82-0.740.560.111.251.48誤差分析: 由于是接著上一組做實驗,沒有等待儀器冷卻,導致實驗數據存在誤差,前幾組數據溫度過高。 迪圖斯-貝爾特公式(Nu O.O23Re0.8 Prn )的條件Re 1.0 104 1.2 105而實驗數據有一個沒有在此范圍之內。所以用此公式算出的Nu'和2存在誤差。 實驗過程中,流量存在波動時,沒有取平局值,導致實驗誤差過大2、冷流體給熱系數的準數式:Nu/Pr04 ARem,以In Nu/Pr0.4為縱坐標,In Re為橫坐標,將實驗數據的結果標繪在圖上,由實驗數據作圖擬合曲線方程,確定式中常數A 及 m;并與教材中的經驗式Nu/pJ40.023 Re0.8比較。冷流體給熱系數的準數式: Nu/Pr0.4 YRem由圖表得擬合曲線方程: y=0.8478x-

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
  • 4. 未經權益所有人同意不得將文件中的內容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
  • 6. 下載文件中如有侵權或不適當內容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論