




版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
KnowledgetrainingofCodeforDesignofLNGReceivingTerminalEngineering(GB51156-2015)MastercorestandardstoensuredesignqualityNormativebackgroundandhistory01Scopeofapplicationandterminology02Stationsiteselectionandgenerallayoutdesign03Detailedexplanationofprocesssystem04EquipmentandPipingConfiguration05Automaticcontrolandinstrumentation06Utilitiesandauxiliaryfacilities07AppendicesandSupplements0801NormativebackgroundandhistoryOverviewofthespecificationdevelopmentprocess01Standard-settingbackgroundTheCodeforDesignofLNGReceivingTerminalEngineering(GB51156-2015)isformulatedtounifyandstandardizethedesignstandardsofdomesticLNGreceivingterminals,improvethedesignqualityandsafetylevel,andpromotethehealthydevelopmentoftheindustry.CompilationgroupinvestigationandresearchIntheprocessofformulatingthestandard,thecompilationteamconductedin-depthinvestigationandresearch,summarizedthepracticalexperienceofLNGreceivingstationconstructioninChina,andreferredtotheinternationaladvancedtechnologyandstandards.StandardsreleaseandimplementationThestandardwasapprovedandissuedbytheMinistryofHousing,UrbanandRuralConstructiononNovember12,2015,andhasbeenformallyimplementedsinceJune1,2016.Mandatoryprovisionssuchas4.1.33and5.9.3mustbestrictlyenforced.0203Releaseandapprovalstatus020301ReleasestatusTheCodeforDesignofLNGReceivingTerminalEngineering(GB51156-2015)wasapprovedandissuedbytheMinistryofHousingandUrban-RuralDevelopmentofthePeople'sRepublicofChinaonNovember12,2015,withthestandardnumberofGB51156-2015.ThestandardhasbeenformallyimplementedsinceJune1,2016.ImplementationdateTheCodeforDesignofLNGTerminalEngineeringhasbeenimplementedsinceJune1,2016.Thisdatemarkstheentryintoforceofthenewnationalstandard,whichrequiresthedesign,constructionandoperationofallrelatedengineeringprojectstocomplywiththenewcoderequirements.MandatoryprovisionsTheDesignSpecificationforLNGTerminalEngineeringcontainsanumberofmandatoryclausessuchasClauses4.1.33,5.9.3,12.1.10,12.1.12and12.1.14.Theseprovisionsmustbestrictlyenforcedtoensurethesafe,reliableandefficientoperationoftheLNGterminal.RelevantstandardnumberanddateofissueStandardreleasebackgroundTheCodeforDesignofLNGTerminalEngineering(GB51156-2015)isformulatedbytheMinistryofHousingandUrban-RuralDevelopmentofthePeople'sRepublicofChinatostandardizethedesignofLNGterminalengineeringandensurethesafety,reliabilityandeconomyoftheproject.StandardreleasedateThespecificationwasissuedonNovember12,2015andformallyimplementedonJune1,2016,andiscurrentlyineffect.ThebackgroundofthestandardwastomeettheneedsofthegrowthofdomesticLNGdemandandtechnologicaldevelopmentatthattime.ImplementationofstandardsSincetheimplementationofthestandard,ithasbeenappliedinmanyLNGreceivingterminalprojects,whichhassignificantlyimprovedthequalityandsafetyofengineeringdesign.ThesuccessfulpracticeoftheseprojectshasprovedthepracticabilityandeffectivenessofGB51156-2015.02ScopeofapplicationandterminologyStandardizeapplicablescenariosApplicationofcitygasAsanimportantsourceofcitygassupply,LNGterminalissuitableforlargecitiesandindustrialareas.Throughefficientreceivingandstoragesystems,thestablesupplyofurbangasisensuredtomeettheenergyneedsofresidentialandindustrialusers.SupportingpowergenerationprojectsLNGterminalsarecombinedwiththermalpowerplantsornuclearpowerplantstoprovidecleanfuelforpowergenerationprojects.Throughstandardizeddesign,thecontinuityandstabilityofgassupplyareensured,theefficiencyofpowergenerationisimproved,andtheenvironmentalpollutionisreduced.TransportationfuelapplicationsLiquefiednaturalgasreceivingstationscanprovidecleanenergyforships,busesandothervehicles.Throughefficientconversionequipment,liquefiednaturalgascanbeconvertedintopowerfuel,reducingdependenceontraditionalfuelsandreducingcarbonemissionsinthefieldoftransportation.DistributedenergysystemSmall-scaleLNGreceivingstationsaresuitablefordistributedenergysystemstoprovideenergyservicesforresidentialcommunities,commercialcomplexes,etc.Throughmodulardesignandintelligentmanagementsystem,theefficientuseofenergyandenvironmentallyfriendlyenergysupplyarerealized.AnalysisoftechnicaltermsAnalysisofbasictermsIntheCodeforDesignofLNGReceivingTerminalEngineering,thebasictermsinclude"LNGreceivingterminal","storagetank","pipeline",etc.Thesetermsarewelldefinedandarethebasisforunderstandingtheentirespecification,ensuringthatengineerscanaccuratelyapplythesetermstodesignandconstruction.TerminologyofprocesssystemTheprocesssystemtermsinthespecification,suchas"storage","transportation","separation"and"recompression",describethewholeprocessofLNGfromreceivingtostorage.Thesetermsareusedtoguidethedesign,operation,andmaintenanceofprocesssystemstoensureefficientprocessingofLNG.TerminologyrelatingtoequipmentEquipmenttermscoveredbythespecificationinclude"tanks,""pumps,""valves,"and"controlsystems.".Thesetermsdescribeindetailthetype,functionandapplicationoftheequipment,provideastandardbasisforequipmentselectionandmaintenance,andensurethereasonableuseoftheequipmentintheproject.SafetyandEnvironmentalTerminologySafetyandenvironmentalprotectionrelatedtermssuchas"fireprotection","explosionprotection"and"environmentalprotection"emphasizethesafetyandenvironmentalprotectionrequirementsinthedesignprocessofLNGterminal.Thesetermsprovideengineerswithclearsafetyandenvironmentalprotectionstandardstoensurethatengineeringconstructionmeetstherequirementsoflawsandregulations.RelateddefinitionsandexplanationsLNGDefinitionLiquefiednaturalgas(LNG)isaliquidfuelobtainedbycooling,compressing,vaporizingandcondensingnaturalgasatatemperatureof-260°F(-162°C)orloweratatmosphericpressure.Itsmainadvantageisthatitiseasytostoreandtransport,andissuitableforlong-distancetransportationandthedevelopmentandutilizationofunconventionalnaturalgasresources.TerminaldefinitionLNGreceivingterminalisafacilitydedicatedtoreceiving,storingandregasifyingLNG,includingreceivingwharf,storagetankarea,regasificationfacilitiesandrelatedprocessequipment.Themainfunctionoftheterminalistounload,storeandregasifyLNGtransportedoverlongdistancestomeettheneedsofendusers.DesigncriteriadefinitionTheCodeforDesignofLNGReceivingTerminalEngineering(GB51156-2015)isaChinesenationalstandard,whichspecifiesthetechnicalrequirementsandmanagementspecificationsforthedesignandconstructionofLNGreceivingterminalstoensurethesafety,economyandenvironmentalprotectionoftheproject.ExplanationofrelevanttermsTherelevanttermsinthespecificationinclude"LNGterminal","storagetank","regasification","pressurevessel",etc.Thesetermshavespecificmeaningsindesign,construction,andoperationandneedtobeusedstrictlyasdefinedintheCode.03StationsiteselectionandgenerallayoutdesignSiteselectionprincipleCompatibilityofintelligenttransportationsystemWiththedevelopmentofintelligenttransportationtechnology,thecompatibilityofintelligenttransportationsystemshouldnotbeconsideredinthelocationofreceivingstation.Realizereal-timemonitoringandmanagementofthetransportationprocess,improvesafetyandoperationalefficiency,andoptimizetheoveralloperationmode.EnvironmentalandSocialImpactAssessmentIntheprocessofsiteselection,detailedenvironmentalandsocialimpactassessmentshouldbecarriedouttoensurethattheprojectwillnothaveanegativeimpactonthelocalecologicalenvironmentandresidents'lives.Throughrationallayoutandenvironmentalprotectionmeasures,sustainabledevelopmentandsocialresponsibilitycanbeachieved.0102030405ConvenienttransportationTheLNGreceivingterminalshallbelocatedinanareawithconvenienttransportationtofacilitatethetransportationandreceivingofLNG.Priorityisgiventoproximitytomajorports,railorhighwaynetworkstoreducelogisticscostsandensureadequateandstablesupplyofrawmaterials.ResourcesupplyandmarketdemandThesiteselectionshalltakefullaccountofthesupplyofLNGresourcesinthesurroundingareastoensuresufficientandstablerawmaterials.Atthesametime,themarketdemandintheareawherethereceivingstationislocatedisanalyzedindepth,includingthedemandinthefieldsofindustry,residentsandelectricity,soastoensuretheeconomicbenefitsoftheoperationofthereceivingstation.NationalEnergyStrategyandRegionalPlanningBasedonthenationalenergystrategyandregionaldevelopmentplan,thefuturemarketdemandtrendispredictedtoprovideforward-lookingguidanceforthesiteselectionofthereceivingstation.EnsurethattheTerminalcomplieswiththenationalenergypolicyandregionaldevelopmentplantoenhancetheeconomicandsocialbenefitsoftheProject.GenerallayoutrequirementsSiteselectionrequirementsAccordingtoCodeforDesignofLNGReceivingTerminalEngineering(GB51156-2015),geologicalconditions,meteorologicalenvironment,transportation,surroundingfacilitiesandotherfactorsshallbetakenintoconsiderationinsiteselection.Adetailedsurveyandassessmentisrequiredtoensurethesafetyandreliabilityofthesite.GenerallayoutprincipleFunctionalareassuchasprocessarea,storageareaandauxiliaryfacilityareashallbereasonablyarrangedinthegenerallayout.Thelayoutshallmeettherequirementsoftheprocessflow,ensuresafeandefficientoperation,andmeettherelevantprovisionsofenvironmentalprotectionandfiresafetyspacing.VerticaldesignrequirementsTheverticaldesignshallconsidertheterrainelevationdifferenceandsiteutilizationefficiencytoensurethereasonableheightofeachprocessequipmentandbuilding.Thedesignshallfacilitatethelayingandmaintenanceofpipes,takingintoaccountdrainageandfloodcontrolmeasures.RoadandTransportationDesignTheroaddesignshallmeetthetransportationneedsofrawmaterialsandfinishedproducts,includingaccessroads,emergencyevacuationroutesandfirelanes.Thedesignshallcomplywithrelevantnationalstandardstoensuresmoothtrafficandemergencyresponsecapability.VerticalDesignandRoadDesignVerticaldesignrequirementsAccordingtoCodeforDesignofLNGReceivingTerminalEngineering(GB51156-2015),theverticaldesignofLNGreceivingterminalshallconsiderequipmentlayout,operationsafetyandmaintenanceconvenience.Reasonablefloorheightshallbesettoensurethatthereisenoughspacebetweenequipmentroomsandmeettherequirementsofrelevantstandardsandspecifications.VerticalTransportationSystemDesignIntheverticaldesign,theverticaltransportationdemandofmaterialsandpersonnelshallbefullyconsidered.Itincludessettingupnecessaryelevators,stairs,conveyorbeltsandotherfacilitiestoensurethatmaterialsandpersonnelcanenterandexitalllevelsefficientlyandsafely.Atthesametime,thedesignofemergencyevacuationpassageshouldbeconsideredtoensurethesafetyofpersonnel.SpecificationsforroaddesignTheroaddesignshallcomplywiththerelevantprovisionsoftheCodeforDesignofLNGTerminalEngineeringtoensurethesafetyandefficiencyoftransportation.Roadcarryingcapacity,vehiclespeedandemergencyevacuationpathshouldbeconsideredinthedesigntomeettheneedsofrapidresponseandevacuationinemergencysituations.RoadlayoutandplanningTheroadlayoutandplanningshallbedesignedinaccordancewiththeoveralllayoutoftheTerminaltoensureunimpededaccessforthetransportationofmaterialsandequipment.Itisnecessarytoreasonablysetuptrunkroads,branchroadsandemergencyparkingareastoimprovetransportationefficiencyandreducetrafficaccidents.Atthesametime,enoughexpansionspaceshouldbereservedtomeetfutureexpansionneeds.04DetailedexplanationofprocesssystemUnloadingandreceivingprocessAnalysisofShipUnloadingTechnologyTheunloadingprocessisanimportantpartoftheLNGterminal,whichinvolvesthesafetransferofgasfromtheLNGshiptothestoragetank.Theprocessincludesrapidshrinkage,pressurecontrol,andleakdetectiontoensureefficientandsafedischargeoperations.UnloadingequipmentandtechnologyUnloadingequipmentmainlyincludesunloadingpump,rapidcoldshrinkandpressurecontrolsystem.Thesedevicesworktogethertoachieveefficientunloadingoperationandensuresealingandsafetyinlowtemperatureenvironmenttopreventleakageorexplosionaccidents.SafetymeasuresduringshipunloadingDuringtheunloadingprocess,thesafetyoperationproceduresmustbestrictlyfollowed,includingthecontrolofpre-coolingspeed,themonitoringofunloadingtemperatureandthemanagementofpressurefluctuation.Rapidcoldshrinkagecausesincreasedstressinthematerial,soslowcoolingisrequiredtoreducetheriskofleakage.StorageandmanagementaftershipunloadingAfterunloading,LNGwillbestoredincryogenicstoragetanks.ThisprocessalsoincludesthetreatmentandrecompressionofBOGtoensurethattheremaininggasiseffectivelytreatedtoavoidenvironmentalpollutionandpotentialsafetyhazards.01020304StorageandregasificationprocessLNGstorageLNGistransportedfromtheplaceofproductiontothereceivingstationbycryogenictankcarorship,andthentransportedtothecryogenicstoragetankforstoragebyunloadingsuperchargerorpump.ThisprocessensuresthestabilityandsafetyofLNGduringtransportationandstorage.LNGregasificationprocessTheLNGregasificationprocessmainlyincludestransportingthestoredLNGfromthecryogenicstoragetanktothegasificationstation,andconvertingitintogaseousnaturalgas(NG)throughpressurizationandheating.ThisstepistorealizetheenduseofLNG,suchascitygassupplyorpowergeneration.SafetyandefficiencymeasuresDuringthewholeprocessofstorageandregasification,theLNGterminaladoptsadvancedsafetyfacilities,suchasfireprevention,leakagemonitoringandcontrolsystem,toensurethesafetyandefficiencyofoperation.ThesemeasuresensurethesafetyandstabilityofLNGinstorageandtransportation.PressurecontrolandtemperaturemanagementPressureControlSystemOverviewThepressurecontrolsysteminLNGreceivingterminalsiscrucialtoensurethesafeandefficientoperationofthefacility.Thesystemmonitorsandregulatesthepressurewithinthetankstopreventoverpressurizationorunderpressurization,whichcanleadtoaccidentsordamagetotheequipment.PressureControlTechniquesTherearevarioustechniquesusedinLNGreceivingterminalsforpressurecontrol,includingmanualadjustmentbyoperators,automaticsystemsthatregulatethecompressorload,Thesetechniquesensurethepressureremainsstableandcontrolledatalltimesduringoperations.TemperatureManagementSystemThetemperaturemanagementsysteminLNGreceivingterminalsisdesignedtomaintaintheoptimalstoragetemperatureforLNG.Thesystemincludesmeasuressuchasinsulation,BOG(BoilingOffGas)recovery,Andheatexchangerstokeepthetemperaturewithinasaferange,whichreducestheriskofequipmentfailureorsafetyincident.TemperatureMonitoringEquipmentTemperaturemonitoringequipmentplaysavitalroleinmaintainingtheproperstorageconditionsforLNG.Theequipmentcontinuouslymonitorsthetemperatureandalertstheoperatorincaseofanydeviationsfromthesetrange.Thisensuresthesafetyandefficiencyofthestorageprocess.05EquipmentandPipingConfigurationIntroductiontomainequipmentLNGunloadingarmLNGunloadingarmisoneofthecoreequipmentofLNGterminal,whichisusedtounloadLNGfromLNGcarriertotheterminal.LNGistransportedintothestoragetankthroughtheliquidphaseunloadingarmandtheunloadingpipelinewiththehelpoftheunloadingpumpontheshiptoensureefficientandsafeunloadingoperation.LNGstoragetankisthekeyequipmentforstoringliquefiednaturalgas,whichisdividedintoabovegroundstoragetank,undergroundstoragetankandsemi-undergroundstoragetank.LargestoragetankswithnormalpressureandlowtemperaturecaneffectivelystorealargeamountofLNGandensurethestabilityofgassupply.Accordingtothesettingmode,theycanbedividedintoinnertankandoutertank.Theinnertankismadeofausteniticstainlesssteel,andtheoutertankisusuallyofprestressedconcretestructure.LNGstoragetankTheBOGcompressorisusedtoprocesstheexcessiveboil-offgasgeneratedbyexternalenergyinputandLNGenteringthestoragetanktomaintaintheconstantpressureinthestoragetank.Theequipmentimprovestheenergyutilizationrateandreducestheenvironmentalpollutionwhileensuringthesafety.BOGcompressorThecontrolsystemoftheLNGTerminalincludesDCS(DistributedControlSystem),ESD(EmergencyShutdownSystem),F&G(FireandGasDetectionSystem)andSCADA(SupervisoryControlandDataAcquisitionSystem).Thesesystemshavebothlocaloperationalcontrolsandremotemonitoringsystems,ensuringthatprocesscomplexityismanagedefficiently.LNGcontrolsystemLNGreceivingterminalcontrolsystemisresponsiblefortheoperationandmanagementofthewholeterminal,coveringmanylinksfromunloading,storagetoregasification.Throughadvancedcontroltechnologyandreal-timemonitoring,thesystemachievesefficientenergymanagementandoperationprocessoptimization,andimprovestheoveralloperationalefficiency.LNGreceivingterminalcontrolsystemEquipmentlayoutprincipleCompactandcoordinatedarrangementofequipmentTheequipmentlayoutoftheLNGTerminalshallfollowtheprinciplesofcompactnessandcoordinationtoensurethatthefunctionalareasarecloselyalignedandcoordinatedwitheachothertoimprovelanduseandoperationalefficiency.Theprocessunitareaandstoragetankareashallbereasonablyseparated,andtheoveralllayoutshallbekeptbeautifulandpractical.SafetydistancerequirementsToensuresafety,theLNGtankfarmshouldbelocatedawayfromresidentialareasandpublicwelfarefacilities,andontheupwindsideofthewinddirectionwiththelowestfrequencythroughouttheyear,soastoreducethepossibleimpactonthesurroundingenvironment.Atthesametime,emergencyevacuationpassagesandfirepassagesshouldbesetuptoensurethesafetyofpersonnel.EnvironmentalprotectionandfireprotectionmeasuresThedesigncodeemphasizestheimportanceofenvironmentalprotectionandfireprotectionmeasures,andrequiresthatthepossiblenitrogensuffocationenvironmentandfirehazardsshouldbefullyconsideredinthedesign.Forexample,theclosedplantshouldbeequippedwithlowoxygenconcentrationdetectionalarm,andsufficientfireaccessandemergencyevacuationfacilitiesshouldbesetup.FunctionalareasareclearlydividedThegenerallayoutoftheLNGTerminalshallbedividedbyfunction,includingprocessunitarea,storagetankarea,flarearea,tankerloadingarea,administrativeofficeandlivingservicearea,etc.Eachareashallbeproperlyarrangedaccordingtoitsspecificfunctionandcoordinatedwithadjacentareas.PipingInstallationandMaintenancePipinginstallationprocessAccordingtotheGB51156-2015specification,thepipelineinstallationofLNGterminalneedstostrictlyfollowthedesigndrawingsandtechnicalrequirements.Frommaterialselectiontotheweldingprocess,everystepisrequiredtoensureleak-freeandhigh-strengthdurability,guaranteeingsafeandefficientcompletionoftheinstallationtask.PipetypeandmaterialThetypesofpipesandtheirmaterialrequirementsfordifferentapplicationsaredefinedinthespecification.Mainpipelinesincludeinputpipeline,outputpipeline,processpipeline,etc.Allpipelinematerialsmustmeettherequirementsoflowtemperatureperformance,corrosionresistanceandhighstrengthtoadapttothecharacteristicsofLNGandextremeworkingenvironment.PipelineinspectionandmaintenanceInordertopreventleakageandotheraccidents,GB51156-2015stipulatesaregularpipelineinspectionsystem.Testingincludespressuretesting,leakdetection,andcorrosionassessment.Maintenanceincludescleaning,coatingprotectionandrepairtoensurelong-termstableoperationofthepipelinesystem.AutomaticcontrolsystemThespecificationemphasizestheimportanceofintroducinganautomatedcontrolsystemforreal-timemonitoringandoptimizationofthepipelinetransportationprocess.Throughtheintelligentsystem,itcanimprovethesafetyofoperation,stabilityofoperationandreducelaborcosts,whileensuringtheaccuracyandreliabilityofdataandachievingefficientmanagement.06AutomaticcontrolandinstrumentationCompositionofautomaticcontrolsystemControlsystemcorecomponentTheautomaticcontrolsystemofLNGterminalmainlyincludesdistributedcontrolsystem(DCS),engineerstation,operatorstationandcontroller.ThesecomponentstransmitdatathroughopticalcablestomonitorandcontroltheLNGreceivingprocess,storageprocess,gasificationprocessandexportprocess.NetworkarchitectureandcommunicationmodeTheautomaticcontrolsystemadoptsMeshnetworktechnologyandusesopticalcableasthemaintransmissionmediumtobuildastarnetworkarchitecture.Thisstructureensuresthatthedisconnectionofthenodepositionwillnotaffectothernodes,andimprovesthereliabilityandstabilityofthesystem.AutomaticmonitoringfunctionThecontrolsystemcanmonitorthepressure,liquidlevel,temperature,flowandotherparametersintheproductionprocessinrealtime,anddynamicallydisplaytheproductionprocessandequipmentoperationstatus.Atthesametime,thesystemhasthefunctionsofabnormalworkingconditionalarmandprintingrecordstoensurethesafestorageofimportantparameters.BOGcontrolandrecoveryprocessAccordingtotheBOGcontrolandrecoveryprocessofLNGreceivingstation,thecomposition,workingconditionandoperationprocessofthecontrolsystemareintroducedindetail.ThiswillhelpoptimizetheBOGcontrolandrecoveryprocessandimprovetheoveralloperationalefficiencyoftheTerminal.InstrumentselectionandinstallationSelectionofmeasuringequipmentAccordingtotheCodeforDesignofLNGReceivingTerminalEngineering,themeasurementequipmentshallmeettheaccuracyandreliabilityrequirementstoensuretheaccuracyandreal-timeofthedata.Commonmeasurementdevicesincludepressuregauges,temperaturesensors,andflowmetersformonitoringgasandliquidflowinprocesssystems.1SpecificationforinstallationofinstrumentsWheninstallingthemeasuringequipment,therelevantnationalstandardsanddesignspecificationsshallbefollowedtoensurethattheverticalityandlevelnessoftheequipmentmeettherequirements.Atthesametime,theequipmentshouldbeinstalledinalocationthatiseasytomaintainandoverhaul,soastoreducedowntimeandmaintenancecosts.2SafetyInstrumentedSystem(SIS)ConfigurationSafetyinstrumentedsystemisakeycomponentofLNGterminal,whichisusedtomonitorandcontrolkeyprocessparameterstoensurethesafeandstableoperationofthesystem.SISusuallyincludesemergencyshutdown,safetyinterlockandalarmfunctionstopreventpotentialaccidents.3AutomaticcontrolsystemAutomaticcontrolsystemincludesDCS(distributedcontrolsystem)andSCAda(supervisorycontrolanddataacquisitionsystem),whichisusedtorealizecentralizedmonitoringandmanagementofthewholeprocesssystemoftheterminal.Automatedsystemscanimproveoperationalefficiencyandreducelaborcosts.4SafetymonitoringandalarmsystemSecuritymonitoringsystemThesafetymonitoringsystemofLNGterminalincludesdistributedcontrolsystem(DCS),programmablelogiccontroller(PLC)andvideomonitoringsystem(CCTV).Thesesystemsareusedtocontroltheoperationofproductionequipmentandensurethesafetyandstabilityoftheproductionprocess.FirealarmandfirefightingsystemFirealarmandfirefightingsystemisanimportantsafetyfacilityinLNGreceivingterminal.Thesystemdetectsfiresignalsthroughsensors,triggersalarmsandstartsfirefightingequipmentintime,effectivelypreventsfireaccidentsandensuresthesafetyofpersonnelandfacilities.PersonnelmanagementandpositioningsystemInordertoimprovetheefficiencyofsafetymanagement,LNGreceivingterminalsareoftenequippedwithpersonnelmanagementandpositioningsystems.Thesystemcanmonitorthelocationofemployeesinrealtime,ensurerapidresponseinemergencies,andassistoperationandmaintenancepersonnelinefficientdataanalysisanddecision-making.EnvironmentalMonitoringandEarlyWarningTheenvironmentalmonitoringandearlywarningsystemisusedtomonitortheenvironmentalconditionsaroundtheLNGreceivingstationinrealtime,includingtemperature,humidity,gasconcentrationandotherparameters.Whenanabnormalityisdetected,thesystemwillissueanearlywarningandlinkuprelevantprotectivemeasurestoensureenvironmentalsafety.07UtilitiesandauxiliaryfacilitiesPowersupplyandtelecommunicationfacilities01DesignrequirementsforpowersupplysystemTheCodeforDesignofLiquefiedNaturalGasReceivingTerminalEngineeringputsforwardstrictdesignrequirementsforpowersupplysystem.Itisnecessarytoensurethereliabilityandsafetyofpowersupply,includingtheconfigurationofstandbypowersupply,theselectionandlayoutofelectricalequipment,etc.,soastoensurethestableoperationofthereceivingstation.StandardforconfigurationofcommunicationfacilitiesAccordingtothespecification,communicationfacilitiesarethenecessaryinfrastructureofthereceivingstation,whichneedtomeetthe
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- Module 3 Unit 1 robots will do everything (教學(xué)設(shè)計(jì))-2024-2025學(xué)年外研版(三起)英語四年級(jí)下冊(cè)
- 圓的初步認(rèn)識(shí)(教學(xué)設(shè)計(jì))-2024-2025學(xué)年四年級(jí)上冊(cè)數(shù)學(xué)滬教版
- 19“設(shè)計(jì)研學(xué)旅行方案”(教學(xué)設(shè)計(jì))2024-2025學(xué)年初中物理項(xiàng)目化課程案例
- Unit 1 Family-Lesson 1 Knowing my family教學(xué)設(shè)計(jì) 2024-2025學(xué)年北師大版英語七年級(jí)上冊(cè)
- 第三單元《走進(jìn)農(nóng)耕鄉(xiāng)韻-實(shí)施總結(jié)階段》(教學(xué)設(shè)計(jì))-2024-2025學(xué)年五年級(jí)上冊(cè)綜合實(shí)踐活動(dòng)浙教版
- 古詩詞誦讀《游園·皂羅袍》教學(xué)設(shè)計(jì) 2023-2024學(xué)年統(tǒng)編版高中語文必修下冊(cè)
- 記錄我的一天(教學(xué)設(shè)計(jì))-2024-2025學(xué)年一年級(jí)上冊(cè)數(shù)學(xué)北師大版
- 武術(shù)防身術(shù) 教學(xué)設(shè)計(jì)-2023-2024學(xué)年高一上學(xué)期體育與健康人教版必修第一冊(cè)
- Unit 6 Reading教學(xué)設(shè)計(jì)2024-2025學(xué)年滬教牛津版英語八年級(jí)上冊(cè)
- 下壓式交接棒 教學(xué)設(shè)計(jì)-2023-2024學(xué)年高一上學(xué)期體育與健康人教版必修第一冊(cè)
- 色彩發(fā)展的歷史課件
- 學(xué)生成長(zhǎng)導(dǎo)師制工作手冊(cè)
- (2023年最新版)醫(yī)師執(zhí)業(yè)、變更執(zhí)業(yè)、多機(jī)構(gòu)備案申請(qǐng)審核表
- 醫(yī)療器械臨床試驗(yàn)質(zhì)量管理規(guī)范培訓(xùn)課件
- 氣流粉碎機(jī)課件
- SJG 74-2020 深圳市安裝工程消耗量定額-高清現(xiàn)行
- GB∕T 41097-2021 非公路用旅游觀光車輛使用管理
- 鐵路乘車證管理辦法
- 軟件項(xiàng)目立項(xiàng)開發(fā)工作流程圖
- 叉車設(shè)備點(diǎn)檢表
- 三方聯(lián)測(cè)測(cè)量記錄表
評(píng)論
0/150
提交評(píng)論