




版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報或認(rèn)領(lǐng)
文檔簡介
1、HP SureStore E XP Disk Array,Overview,XP ARRAY,Disks 15GB to 182GB,CACHE,XP Architecture,XP Disk Emulation,Recommended for drives 20 Gb,Suggested for 36Gb drive,XP Characteristics,XP 256(A5700A) Number of slots : 256 Number of disks : 240 Numbers of spares : 8+8 Type of disks : 15/36/47/72GB Cache s
2、ize :1/16GB Shared memory : 128 to 512MB Numbers of ports : 4/32 Type of ports : SCSI/FC/ESCON Internal I/O :480-270MB/s Numbers of Ldev : 1024 Numbers of LUN : 2048,XP 48(A5920A) 48 48 4 18/47/72/180GB 1/16GB 256/1.2GB 4/24 FC/ESCON 1.6GB/s 4096 8192,XP 512(A5950A) 576 512 8+8 18/47/72/180GB 1/32GB
3、 256MB/1.5GB 4/32 FC/ESCON 3.2 GB/s 4096 8192,XP Caracteristics,XP 128(A7906A) Number of slots : 128 Number of disks : 128 Numbers of spares : 4+4 Type of disks : 36/72GB Cache size :2/32GB Shared memory : 512MB to 3GB Numbers of ports : 4/24 Type of ports : ESCON/FC1/2 Internal I/O :5 GB/s Numbers
4、of Ldev : 8192 Numbers of LUN : 12288,XP 1024(A7876A) 1024 1024 8+8 36/72GB 2/64GB 512MB to 3GB 4/32 ESCON/FC 1/2 10 GB/s 8192 16384,XP256 Configurations,Basic Unit has 1 Controller (DKC) and 1 Disk Unit (DKU),Full Unit has 1 Controller (DKC) and 4 Disk Units (DKU),XP512 Configurations,Basic Unit ha
5、s 1 Controller (DKC) and 2 Disk Unit (DKU),Full Unit has 1 Controller (DKC) and 6 Disk Units (DKU),XP48 Configurations,Basic Unit has controller (DKC) and Disk units (DKU) in 1 unit,XP128 Configurations,Basic Unit has controller (DKC) and Disk units (DKU) in 1 unit,XP1024 Configurations,Basic Unit h
6、as 1 Controller (DKC) and 1 Disk Unit (DKU) A Full Unit has 1 Controller (DKC) and 4 Disk Units (DKU),Disk Array Controller (DKC) and Disk Unit (DKU),XP Configurations multi-rack,DKC,DKU,DKU,DKU,DKU,R1 R2,L2 L1,Frame name,XP Front (XP1024),DKU,SVP,Front logic gate,Batteries controlers,Breakers,Canis
7、ter (HDU),Disk (HDD),Breakers,DKC,Control panel,XP Front cage cards,Slot Identifier,Cluster 1 (CL1),Cluster 2 (CL2),A,B,C,D,A,B,C,D,ie- 4 Port FC CHIP pairs,E,F,G,H,J,K,L,M,N,Q,P,R,N,Q,P,R,J,K,L,M,E,F,G,H,N P Q R S T U V W X Y Z,XP Rear Logic Gate,M L K J H G F E D C B A,Slot Identifier,Cache Switch
8、,Access Control Processors (Internal FC Channel Adapters) L, K, J, H,Cache Switch,Access Control Processors (Internal FC Channel Adapters) E, D, C, B,F/G= Cache,Note - Slot “I” is not used (too easily confused with numeric one),Cluster 2 (CL2),Cluster 1 (CL1),XP Rear Logic Gate,R1,L1,L2,R2,ACP Pairs
9、 separated between two power boundaries,DKC Rear,Domain 3,Domain 4,Domain 2,Domain 1,XP ACP domains,2 SCSI Buses,2 Power Supplies,XP HDU,XP256,XP512/48,XP1024/128,2 Power Supplies,12 HDDs “Hard Disks”,2 FC_AL,4,00,04,02,06,08,0A,0C,0E,01,03,05,07,09,0F,0D,0B,JMP,JMP,F,S,W,1,0,F,S,W,1,1,F,S,W,2,1,F,S
10、,W,2,0,10,14,12,16,18,1A,1C,1E,11,13,15,17,19,1F,1D,1B,JMP,JMP,2 Power Supplies,32 HDDs “Hard Disks”,2 FC_AL,Dynamic duplexed write cache used for data transfer All writes duplexed Separate power boundaries Non-volatile cache protected 48 hours with batteries Duplexed shared memory used for ACP cont
11、rol and command,Duplexed writes,Duplexed Write Cache,16 GB Max for XP256 & XP48 32 GB Max for XP512 & XP128 64 GB max for XP1024,Memory,Read data,Write Data Copy A,Write Data Copy B,70% Maximum Duplex Write limit (optimal),50% Default Duplex Write limit (default),30% Minimum Duplex Write limit (opti
12、onal),Cache A,Cache B,HP XP Cache Dynamic Write Line,Cache Memory,Power Boundary,Shared Memory (mirrored),Ldev Map,Ldev Map,Cache Map,Cache Map,Cache Management: Fast Write,Directory,Data,1. CHIP initiates a search on the cache directory 2. Data is transferred from the host to the cache and duplexed
13、 3. Host is notified of I/O completion 4. Directory in cache is modified to reflect the most recently used data 5. Data is de-staged to the disk in background,DKAs,Hardware and Architecture,XP256 Installation,HP XP256 Storage Architecture,Control Bus,Control Bus,Service Processor (SVP),Data Bus,Data
14、 Bus,Hot Line,Cache - A,Cache - B,Intel i960,LCP,FM,Intel i960,LCP,FM,Intel i960,LCP,FM,Intel i960,LCP,FM,Shared memory B,Shared memory A,SCSI CTL,i960,FM,SCSI CTL,DRR,SCSI CTL,i960,FM,SCSI CTL,DRR,Intel i960,LCP,FM,Intel i960,LCP,FM,Intel i960,LCP,FM,Intel i960,LCP,FM,LAN,CHIPs,ACPs,Cache Memory SI
15、MM Location XP256,Cache SIMMs are 128 Mb each, installed in sets of 4 SIMMs on each Cache Board. The second Cache board must be duplicated. The numbers indicate the installation order. Upgrades are 8 SIMMs per order For a total of both boards of 1Gb. SIMM puller is required to remove the SIMM,Shared
16、 Memory Location XP256,Shared Memory Located on Basic cache boards (F & G) SIMM size is 64 Mb (HP installations) Max is 512 Mb (4 SIMMs each board) Installed as sets of 2 (128Mb 1 on ea bd.) SIMM puller is required to remove the SIMM,15, 36.9, 47.1, 72 GB Disk Drives,High reliability design Dual spi
17、ndle bearings Anti-shock mounted disk Microprocessor controlled Downloadable micro-code Dual ported, SCSI-2 2.5 and 3.5 inch form factor Third generation MR heads,HP XP256 Mainframe Disk Technology,Be careful when removing the cover during maintenance, to ensure the HDD interlock jumper is not dislo
18、dged resulting in HDD failure. 72Gb HDD shown, notice jumper is different.,R1,L2,L1,R2,0,1,2,3,4,5,6,7,0,1,2,3,4,5,6,7,Array Group (for example slot 3 in canisters 0, 1, 2, & 3 in DKU-R2 are part of the same RAID 5 array group),0,1,2,3,7,6,5,4,HDD Location Think of the letter “C” when trying to iden
19、tify a HDDs location,HP XP256 Hardware Schematic,Draw a CU 80% model.,HDUs In Frame R1 or Frame L1,HDUs In Frame R2 or Frame L2,Slot never used due to SCSI only supporting 15 drives plus controller.,Note - The numbers which are shown are logical identifiers for the disk drives not SCSI addresses. Fo
20、r proper orientation, think of the letter “C” (represented by the dashed arrow).,HP XP256- Canister Identification,DKC,L1,L2,R1,R2,HP XP256 HDU Numbering in a B4,B4 in Frame R1 and R2,Drive Slot numbers (top row) vs Disk set installation order (bottom row),DKA and SCSI Buss per HDU (Canister),Array
21、Group- Example,Array Group 5-6,DKU Front,DKU Back,Array Group 2-4,2-4,DKU Front,DKU Back,2-4,2-4,2-4,R1 (DKU-1),DKC,R2 (DKU-2),L2 (DKU-4),L1 (DKU-3),Cable DKC-F310I-24C,Ary Group 51,Ary Group 50,Ary Group 45,Ary Group 46,Ary Group 47,Ary Group 48,Ary Group 49,7th B4,Ary Group 53,Ary Group 54,Ary Gro
22、up 55,Ary Group 56,Ary Group 57,8th B4,Ary Group 52,Ary Group 58,HP XP256 Array Groups,Domain,D1,D2,D3,P,D1,D2,P,D3,RAID-5 3D + 1P Array Groups *,* Shows logical, not physical view,B4 - Array Group 1-1 1-2 1-n,RAID-5 Array Groups,D1,M2,M4,D3,RAID-1 Two 1D + 1M Array Groups*,* RAID1 copy is within the same DKA pair,B4 - Array Group 1-1 1-2,RAID-1 XP256 Arra
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025年中國紫砂鍋行業(yè)市場運(yùn)行現(xiàn)狀及投資戰(zhàn)略研究報告
- 初中高鐵乘務(wù)員培訓(xùn)課件
- 兒童畫水獺課件
- 2025年東方學(xué)校招聘小學(xué)初中學(xué)科教師筆試考試試題【答案】
- 人民幣課件教學(xué)課件
- 培訓(xùn)課件開發(fā)合同
- 2026版《全品高考》選考復(fù)習(xí)方案生物05 增分微課2 平拋運(yùn)動與圓周運(yùn)動的綜合問題含答案
- 戶型介紹培訓(xùn)課件
- 廣東政治數(shù)學(xué)試卷
- 培訓(xùn)課件模板種植培訓(xùn)
- 神經(jīng)網(wǎng)絡(luò)技術(shù)在船舶輻射噪聲預(yù)報中的應(yīng)用與研究
- 中職生:高職單招數(shù)學(xué)各章節(jié)專項(xiàng)練習(xí)試卷及答案
- 高職單招英語詞匯表
- 汽車涂裝工藝知識大全
- 2025年中國心梗鑒定儀市場運(yùn)行態(tài)勢及行業(yè)發(fā)展前景預(yù)測報告
- 蘇州2025年江蘇蘇州市教育局直屬學(xué)校招聘教師57人筆試歷年典型考點(diǎn)(頻考版試卷)附帶答案詳解版
- 2025屆高三英語一輪復(fù)習(xí)人教版(2019)選擇性必修第一冊單詞默寫紙
- 第二單元 主題活動一《我是聰明的消費(fèi)者》(說課稿)-2023-2024學(xué)年四年級下冊綜合實(shí)踐活動內(nèi)蒙古版
- 2024年物聯(lián)網(wǎng)平臺開發(fā)與運(yùn)營服務(wù)合同3篇
- 建設(shè)單位安全質(zhì)量管理制度
- 《教育系統(tǒng)重大事故隱患判定指南》知識培訓(xùn)
評論
0/150
提交評論